In this video I return to a customers house where she had a dirty outside coil, leaking evaporator coil, and faulty flue pipe! #hvacguy #hvaclife #hvac #airconditioner #heatpump #hvactrainingvideos #furnace #hvactroubleshooting #hvactechnician #hvacinstall ‪@ruud‬
Merch Store : hvac-guy-2.creator-spring.com
HVAC LIFE FB Group: / 521086622906115
Here are links to the tools I use, It costs nothing extra for you to buy from this list, and it supports the channel:

Appion Charging Tee: amzn.to/46mRLVg
Milwaukee 12V Impact: amzn.to/440YLFP
Ampeak 2000 Watt Pure Sine Wave Inverter: amzn.to/3NCmINT
Yellow Jacket Tubing Expander: amzn.to/3EvEQnF
Yellow Jacket 60278 Flaring Tool: amzn.to/3FPjlyY
Veto Pro Pac Tech MCT Blackout: Amzn.to/3iCieJK
DeWalt work table: amzn.to/3fKChoB
Inficon D-tek Stratus: amzn.to/3zNg7IO
3 Amp Lil’ Popper: amzn.to/3D5lt3e
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Blutooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Fluke 975 Air Meter: amzn.to/3GwD9oM
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

10 июл 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 63   
@Tigerhawk1981
@Tigerhawk1981 Год назад
"you tried to be thorough" dude you're the most thorough HVAC guy out there, epic job
@HVACGUY
@HVACGUY Год назад
Thanks
@Bob.W.
@Bob.W. Год назад
Screws flying, stuff coming apart, stuff dropping, now that's more like how I do things, lol. Thanks.
@kennyjustman933
@kennyjustman933 Год назад
I was taught to sand "before" you cut
@fabioferrari2995
@fabioferrari2995 11 месяцев назад
Perché?
@scottmaz4063
@scottmaz4063 Год назад
Job well done Curtis
@thwompalot5000
@thwompalot5000 Год назад
I felt every second of getting that panel on 😅😂
@kens.3729
@kens.3729 Год назад
A Lot of things were Fixed and you know the Customers are Blessed they have such an Overqualified HVAC Technician handles their HVAC Issues Super Efficiently. 👍🙏
@MikeB9771
@MikeB9771 Год назад
As always, you knocked it out of the park. On a side note, my HVAC GUY sticker showed up Gonna stick it somewhere prominently in the van, love your channel Curtis.
@HVACGUY
@HVACGUY Год назад
Thanks man
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Top notch pro work. Thanks for recording entire repair
@HVACGUY
@HVACGUY Год назад
Any time!
@OnusBones
@OnusBones Год назад
That was a lot of work. Nice fixes. Shopping list: 1) zip ties; 2) Nitrogen
@natersalad889
@natersalad889 Год назад
Add a new unbroken inspection mirror to the list
@Alamog54
@Alamog54 Год назад
Man I’m hooked on these vids!!
@stevencossaboon3237
@stevencossaboon3237 Год назад
Great job Curtis.
@joshuaseaton4526
@joshuaseaton4526 Год назад
Hey Curtis. The STAMCA are the cased and the STAVUA are the uncased. Keller Air here stocks both of them.
@baldoh.6897
@baldoh.6897 Год назад
Nice job like always!.... outstanding.
@scottowen3162
@scottowen3162 Год назад
!!1😀😀😀 YAY YAY YAY YAY!! LONG VIDEO ABOUT TIME!! I LIKE LOUNGER VIDEOS.😃😃😃😃🤩🤩🤩🤩😃😃
@davidtaylor7174
@davidtaylor7174 Год назад
Nice job on the brazing. I would've bet money on some of those pine needles burning.
@GeorgeSoftlySr
@GeorgeSoftlySr Год назад
Great work once again!
@zachball9351
@zachball9351 Год назад
Brave soul brazing around all those pine needles. I have the 3x2 crimper and find that it seems to be more productive having the 3 on the inside.
@AlexNH56
@AlexNH56 Год назад
Thank you for this video Curtis had a blast watching this one before the all star game!
@HVACGUY
@HVACGUY Год назад
Glad you enjoyed it!
@89tin
@89tin Год назад
12:34 should have done a collaboration with SB Pressure Washing
@tphvac87
@tphvac87 Год назад
Why all the locking caps is huffing refrigerant big in your area? 🤣 Nice work Curtis Only a few towns and jurisdictions require us to add those where I live in the northeast
@HVACGUY
@HVACGUY Год назад
It’s just one of the codes our inspectors like to enforce
@tphvac87
@tphvac87 Год назад
@@HVACGUYWhat is that thing in the aux drain line for the evaporator drain pan never seen one before? 🤷‍♂️
@HVACGUY
@HVACGUY Год назад
@@tphvac87 electric water sensor
@Keith_Mikell
@Keith_Mikell Год назад
@@tphvac87 I run 2 primaries on my bosch. I dont have a switch but thats soon to come. these newer units put out so much water.
@Keith_Mikell
@Keith_Mikell Год назад
Nice clean watch band. Love it. I need to get some stickers. I was the charity video Mikey pipes did in april in PA.
@robalexander7348
@robalexander7348 Год назад
Well done Curtis, with that big repair it should now run like it's new 👍 Au
@hinspect
@hinspect Год назад
Great Video!😊
@HVACGUY
@HVACGUY Год назад
Thanks! 😊
@natersalad889
@natersalad889 Год назад
PLEASE replace that inspection mirror..... that's been broke for so long....
@Goodfella0982
@Goodfella0982 11 месяцев назад
it's just a mirror, it still works. This man is wayyy too busy to fix something that's not really broke.
@robertwojtowicz933
@robertwojtowicz933 Год назад
Some of the manufactures of coils I deal with will void the warranty if you remove the coil out of the case
@GoPappy419
@GoPappy419 4 месяца назад
Yeah, And those Manufactures have no confidence in their equipment so they put this type of clause in their warranties so they don’t have to pay for anything.
@jamierushing
@jamierushing Год назад
Hi bro from west Alabama
2 месяца назад
Hey you need a small tray for all those screws and nuts.
@Hvac-dude
@Hvac-dude Год назад
Our is 3 feet to
@Balticblue93
@Balticblue93 Год назад
That is definitely cutting it close at 36" on that meter to contactor.
@Austin23191
@Austin23191 Год назад
Curtis have you been installing many of the new Bluetooth equipment by rheem? We just had a new furnace giving the econet thermostat an error code for flame present with gas valve off. Heat hasn't been running needless to say so time for a new board and it hasn't been 2 weeks with this unit
@HVACGUY
@HVACGUY Год назад
Not yet!
@Austin23191
@Austin23191 Год назад
​​@@HVACGUYnd a word of warning. The 3 stage units from 14-16 seer are fairly loud when they go to 100% capacity. At 100, they use a contactor and capacitor. From 40-70%, they use an inverter. The 18 seer units are full inverter
@danwittels5542
@danwittels5542 Год назад
What happened to your work table? Good job!
@acrservicesmathewr7565
@acrservicesmathewr7565 Год назад
Do you need a special tool for the locking caps or is it just a shradder tip
@HVACGUY
@HVACGUY Год назад
Those particular ones need a special tool.
@Balticblue93
@Balticblue93 Год назад
@@HVACGUY Which tool and caps do you use (Black and yellow handle)? I am not sure it is in your tools list on your video summary.
@michaellow5448
@michaellow5448 4 месяца назад
Nice job. I’m in Ontario and our code won’t allow act unit right beside the gas meter
@ThePappas33
@ThePappas33 Год назад
You fussin with those screws time to retire that socket and grab a new one...
@axeforever1112
@axeforever1112 Год назад
does any1 else hate this service rachet wrench so bad?
@kennyjustman933
@kennyjustman933 Год назад
best if you use a cordless ratchet wrench, makes this a beeze
@harrydickson4575
@harrydickson4575 Год назад
👍👍👍
@davidskaggs9914
@davidskaggs9914 9 месяцев назад
Do you ever use stay bright 8 or quick connections instead of brazing?
@joshuaseaton4526
@joshuaseaton4526 Год назад
Oh, and take that side drain pan out next time.
@tombeilman5579
@tombeilman5579 Год назад
You give up on the pro press
@HVACGUY
@HVACGUY Год назад
No, I use both.
@thefreshride1510
@thefreshride1510 Год назад
May you turn the cc please?
@tedhicks5431
@tedhicks5431 6 месяцев назад
My micron fairly new nt working well didnt I see you clean it with alcohol
@ICONBADGTA
@ICONBADGTA Год назад
The Rheem-Ruud product is soooo very "SUPERIOR" to their counterparts in sooooo many ways! 1. Fully Painted cases 2. Simplistic designs 3. Smaller Airhandlers 4. Super easy workability and access! LIST GOES ON AND ON AND ON! I'll (NEVER) turn back to other brands unless forced to!
@user-su5ft8lc9q
@user-su5ft8lc9q 8 месяцев назад
Why the locking caps on the refrigerant lines, are you guy got freon sniffers of the human kind.?
@scottmaz4063
@scottmaz4063 Год назад
Job well done Curtis
Далее
Ручка из шланга, лайфхак
00:11
Просмотров 14 тыс.
No AC.  Capacitor replacement and coil cleaning
14:44
Просмотров 2,5 тыс.
Class - What Superheat Signifies
17:07
Просмотров 229 тыс.
HVAC Scam failed again on 2nd opinion call
18:59
Просмотров 108 тыс.
Reviving an Older Rheem Gas Pack! #hvacguy #hvaclife
47:18
Working On An Antique Going Out On Thermal
39:10
Просмотров 15 тыс.
Economizer Trickery - Air Conditioning Troubleshooting
13:09
Ручка из шланга, лайфхак
00:11
Просмотров 14 тыс.