I walk through how I fixed an illegal S trap setup with an inline vent, also called an AAV (air admittance valve), for drainage in a laundry room with a sink.

Наука

Опубликовано:

 

15 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@noelburke6224
@noelburke6224 10 месяцев назад
This is the wrong way to install a vent the vent should terminate 13 inches above the flood level of the sink.This information is from a master plumber
@jacksplumbingvideos7147
@jacksplumbingvideos7147 5 месяцев назад
Those vent valves dont need to be above the flood level at least in my area, most manufacturers just say a minimum of 5 inches above the tee.
@legolwa
@legolwa 3 месяца назад
@@jacksplumbingvideos7147 my code says 4" above the tee.
@modarm
@modarm 10 месяцев назад
Not a lot of space above the vent to unscrew if you ever needed to replace the unit from what I could see in the video.
@2011Maynard
@2011Maynard 3 месяца назад
Don’t take the distance-above the Tee as being gospel. Check your local codes to ensure that distance above is above-flood or above-tee. You will fail inspection and could have problems filing insurance damage claims for overflow flooding if not done properly.
@MrTinks01
@MrTinks01 10 месяцев назад
When was the original installed??.. if before no S traps allowed -it is legal. No code ever says to go back and update any system installed under a prior code or no code. You only have to meet the current code on anything installed at that time.
@2011Maynard
@2011Maynard 3 месяца назад
Not always true… if just replacing the trap, maybe. If remodeling - must meet code!!!
@SloverOfTeuth
@SloverOfTeuth 10 месяцев назад
Very helpful thanks. If one instead used an open external vent pipe, what's the minimum height it needs to run to please?
@VincentStevenson
@VincentStevenson 10 месяцев назад
If the vent pipe doesn’t have an AAV on the end of it then you’re supposed to have it vent above the roof so any sewer gases are not going into your home.
@paulmiller6277
@paulmiller6277 10 месяцев назад
It can every where else in the world America must have different water to rest of us
@jeromewelch7409
@jeromewelch7409 10 месяцев назад
Wait a minute? You're advocating this is a fix? Looks like you're doing a pretty extensive rehab. You have the walls open seems you're in the basement as the pipe terminates to concrete so you have access to this vent, but failed to connect to it through any and all means. You're leaving the ferco tee which appears to be inside of wall. where is this 4 inches that you mentioned coming from at least 4 inches? you need to be 12 inches above the rim of the flood zone? Which in your case is top of your washing machine trap arm which absolutely needs to be 2 inch in size you will not like the results of leaving that vent in that location where you're clearly draining the washing machine above the point of vent… your washing machine is going to discharging! Out of your vent!!!!….. DoDYI
@ragtop63
@ragtop63 10 месяцев назад
When you say "illegal", do you mean illegal in CA?
@legolwa
@legolwa 3 месяца назад
An s-trap is no longer legal in the USA
@bradjenkins932
@bradjenkins932 3 месяца назад
It's not illegal.... The vent must be 6" above sink!!
Далее
КАК Я ЭТО СДЕЛАЛА?
00:13
Просмотров 412 тыс.
🎙ПЕСНИ ВЖИВУЮ от КВАШЕНОЙ🌇
3:16:26
GOOD P TRAPS, BAD P TRAPS, AND FUNKY P TRAPS!!
8:43
Просмотров 135 тыс.
Air Admittance Valves
9:27
Просмотров 235 тыс.
The #1 DWV Plumbing Mistake (and how to prevent it).
3:07
Island sink venting
7:04
Просмотров 95 тыс.
How to Install a Drain with an Air Admittance Valve
8:36
How Do P-Traps Work? 5 Drain Issues to Watch Out For
6:58
Who Needs a Plumber When You Can Do THIS!
4:58
Просмотров 122 тыс.
КРУТОЙ ТЕЛЕФОН
0:16
Просмотров 6 млн