Gas Furnace SPARK IGNITION Operation and Testing! 

AC Service Tech LLC
Подписаться 503 тыс.
Просмотров 90 тыс.
50% 1

In this HVAC Training Video, I Show the Components, Wiring, and Operation of a Direct Spark Ignition System! I Discuss Power Inputs, Flame Proving, Ignition, and How it all Works! I Show the Common Problems and Troubleshooting of this Setup! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
UEI DL489 Multimeter: amzn.to/47Fod5n
Alligator Jumpers- amzn.to/2PxqJXn
Magnet Jumpers- amzn.to/2PyKPQZ
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• Gas Furnace Training C...
• HOT SURFACE IGNITOR Tr...
• NO HEAT? Top 10 Proble...
• Explaining "Gas Furnac...
• 7 Gas Furnace Installa...
• 5 Gas Furnace Parts Th...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #directspark #ignition #flameproving #flame #powerinput #spark #ignitionsystem #troubleshooting
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Опубликовано:

 

27 дек 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 108   
@zahedaminullah6934
@zahedaminullah6934 Год назад
Great videos as always. Well explained and I love the way you laid out all your components. This helps all of us a lot. Keep up the good work as always!
@coldfinger459sub0
@coldfinger459sub0 Год назад
I wish training videos like this were available when I was a kid since my dad forced me to learn at the age of 12 and we had to order books through snail mail or request our local library to order them which would take 5 to 8 weeks for delivery. Back before the Internet was invented..
@1984juant
@1984juant Год назад
Greetings👋. Do this mean anybody can service their own furnaces? I dont like that prospect.
@THExBIGxBADxWOLF93
@THExBIGxBADxWOLF93 5 месяцев назад
Better that way because you really learn compared to this I’ll learn and forget just because it was too simple
@coldfinger459sub0
@coldfinger459sub0 5 месяцев назад
@@THExBIGxBADxWOLF93 it good for the simple ones who get over whelmed seen too many things that are spread out . Some students learn better when everything is like on one page in front of them . Have to teach different types of students learning abilities differently. Some students can learn just by reading words without ever seen an actual furnace . Other students literally have to put their hands on the pieces take them off and put them back together before they learn . It all depends on the type of student you are teaching .
@BeardGawd88
@BeardGawd88 Год назад
I always double check power. Great stuff, my company doesn’t teach this stuff, glad i can learn on here!
@grashoprsmith
@grashoprsmith Год назад
Isn't that sad
@5822huron
@5822huron Год назад
There comes a point where you as a tech must educate yourself. Don't wait or expect any company to get you there.. Trust me! They wont
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity Год назад
Most don’t because of high turnover, takes away profits and they’ll just be teaching their future competition.
@HANDYMANDAN51
@HANDYMANDAN51 Год назад
Awsome , every heating service should view this,thanks.
@zproxiimiity7733
@zproxiimiity7733 Год назад
I love the way you teach! Your wording is on point. Hands on is the cherry on top!
@jimmylanders2175
@jimmylanders2175 Год назад
Great video Craig and very thorough.
@jimbarron8688
@jimbarron8688 9 месяцев назад
No need to look any further for a video covering direct spark ignition furnaces. This is the holy grail. Very thoughtful and thorough presentation.
@mathman0101
@mathman0101 Год назад
Craig you are going to need a furnace book to complete the set of books you already have and your videos then act as a great complement. Always well explained and laid out.
@acservicetechchannel
@acservicetechchannel Год назад
Thank you so much!!! That last book took two years!
@mathman0101
@mathman0101 Год назад
@@acservicetechchannel anything good always takes time and effort to plan and then write.
@stevencossaboon3237
@stevencossaboon3237 Год назад
Great video Craig. Thank you.
@christopherborner1139
@christopherborner1139 Год назад
Craig, once again a great explanation! Thank you so much. You explain things so precise and simple. Love the video.
@jed837
@jed837 Год назад
Craig, you have wonderful videos for those coming up into the HVAC/R trade. Well explained . I’ve been in the trade over 30 years, and I’ve gotta say this is good stuff. Keep up the good work and happy new year!!!
@acservicetechchannel
@acservicetechchannel Год назад
Thanks so much Johnny!!!
@mouseley
@mouseley Год назад
Great video, very well organized and laid out. Great lab setup.
@deanmartin1966
@deanmartin1966 Год назад
Once again, excellent explanation. Thanks for sharing.
@rammyfernando
@rammyfernando Год назад
very beautifully explained
@juanital.2608
@juanital.2608 9 месяцев назад
You are This Old House crew worthy. Great job, great speaking voice. You'd be great on their show. This is exactly how they explain things & why i love it. You've got another new follower in me. Great job, keep it up! 👏👏👏
@gideonlord-adem
@gideonlord-adem Год назад
Great experience with good explanations
@RZeee..
@RZeee.. Год назад
Great illustration. Thank you!
@Yeti808
@Yeti808 9 месяцев назад
Amazing job explaining the operation of a spark ignition. Thank you boss man!
@noahoyeah
@noahoyeah Год назад
Wow! Very good video!
@davidwilliams729
@davidwilliams729 8 месяцев назад
Love this guy! Thank you for making this video
@repairitdontwreckit4257
@repairitdontwreckit4257 Год назад
Another excellent video. Thanks
@estebancastro6297
@estebancastro6297 Год назад
Gracias!! Well explained
@panchobarajas3008
@panchobarajas3008 Год назад
Good video thanks Craig
@joshuaadkins9998
@joshuaadkins9998 6 месяцев назад
Excellent tutorial. Great video! Thank you
@jaysingh-ho7eb
@jaysingh-ho7eb Год назад
Great video! Thanks
@westsidehvac1097
@westsidehvac1097 Год назад
beautiful video
@technician9722
@technician9722 Год назад
Great video.
@JA-vy1gp
@JA-vy1gp Год назад
Great video !! Thank you
@victor.mnoriega3586
@victor.mnoriega3586 10 месяцев назад
I really love your classes, Thank you.
@acservicetechchannel
@acservicetechchannel 10 месяцев назад
You're very welcome! Thank you for enjoying our content!
@Onatena
@Onatena Год назад
Great video Thanks a lot 🙏
@indiantraveller194
@indiantraveller194 Год назад
Great job sir 😘🙏
@ivanl8613
@ivanl8613 Год назад
exelent videos !!!
@manuelcastillo8472
@manuelcastillo8472 Год назад
Thanks nice and clear
@coolramone
@coolramone Год назад
Thanks Craig! This will help me fix my gas furnace that won’t stay lit for more than a few seconds. It’s probably the flame rod not sensing flame and either needs cleaning or replacing, but now I know how to test the flame rod, thanks to you. URDB (you are dee best!) :)
@xxycom8963
@xxycom8963 Год назад
Clean the flame sensor
@5822huron
@5822huron Год назад
Rarely will you replace a fs
@bill98778
@bill98778 Год назад
Great video!!! I wish if you would have a video about domino’s pizza chain oven, thank you Craig and happy new year 2023🎉
@waltherherrera67
@waltherherrera67 8 месяцев назад
Excelente muy bien Gracias
@sonle-fz1xb
@sonle-fz1xb Год назад
Thank you so much
@germanrivas9925
@germanrivas9925 Год назад
Thanks!
@acservicetechchannel
@acservicetechchannel Год назад
Thanjks so much German!
@d.c2123
@d.c2123 Год назад
BRAVOOOO!
@user-mo7hu1yb8l
@user-mo7hu1yb8l Год назад
Thanks
@davidnecky8524
@davidnecky8524 Год назад
Excellent video as always!
@paulthibodeau1269
@paulthibodeau1269 8 месяцев назад
Great video! I have a Rheem direct spark ignition unit. The unit would short cycle where the burner would light and burn for about 4 seconds then shut off. After a few attempts, it wouldn't do anything for about an hour. I couldn't call anyone because of my work schedule and it being a holiday week also. I took a shot and ordered a new dual electrode spark ignitor from Amazon, which showed up in only 2 days. After I installed it, my heater works perfectly. Was this just a coincidence or does the spark ignitor have something to do with the flame rectification process? (it was labeled ignitor/flame sensor) Thank you.
@aifrisyad7491
@aifrisyad7491 Год назад
great video…suggest more video about intermittrnt gas valve with ignition control…thanks anyway
@YTsux24-7
@YTsux24-7 Год назад
Frankenfurnace by AC Service tech! Awaiting UL approval...
@marcosaguilera1760
@marcosaguilera1760 3 месяца назад
Good morning, excellent explanation and I like your videos, you know a lot, I have a question about my furnice, when it calls to turn on the sparks it clicks for 30 or 40 seconds and it turns on and works well, what could be the reason, thank you
@rj.parker
@rj.parker Год назад
The only clarification I would offer is flame sensing microamps (ua) is present on the sense wire as well as the ground wire. You need both to complete the circuit.
@chrisdeanndavison3626
@chrisdeanndavison3626 Год назад
True, and I believe Craig covered this starting at about 8:00 through 10:00.
@aidanpeluso8350
@aidanpeluso8350 Год назад
Can you make a video explaining common/neutral wires. What they are, why they are there and what they do?
@takleung7130
@takleung7130 Год назад
24V into the ignition module but 120V out to the sense wire. Is there a step-up transformer in the module? Am I missing something?
@pointblankmatt6580
@pointblankmatt6580 Год назад
i mean it also provides 10000 volts for the ignitor. was curious about this as well. has to be something internal in the ignition control
@MrSnomanjankens
@MrSnomanjankens Год назад
I had a headache yesterday with a direct spark ignition furnace, except it had a pilot ignition assembly with a single flame rod. The ground wire was hanging on by a thread & was enough to not not give it proper ground. Also the pressure switch was constantly opening and closing since the inducer is on its was out only pulling .67” of WC on a .70” WC switch. The arching from the spark ignition due to the opening/closing of the pressure switch I think may have caused the pilot assembly ground to fail? 🤷
@martini4620
@martini4620 Год назад
A couple months ago we installed a 95% Ruud furnace.It is now rusting very bad , the inside of the inducer collected some orangish rust. Even drain coming out is orange/rusty. Has correct gas pressure. Has both exhaust and intake going outside. RUUD Model # R95TC0701317MSA
@Yeti808
@Yeti808 Год назад
Proper duct sizing?
@Kh2456
@Kh2456 Год назад
Having issues with my raypak pool heater. I have identified it down to a flame rectification issue as the pilot lights well and doesn’t activate the main gas valve for burners. Today I attempted to test the negative for micro amps (disconnected from gas valve) I connected it in series and couldn’t get a micro amp reading. When unplugging I got electrocuted by touching one probe of the multimeter when the positive was plugged into the negative. Why would the negative be carrying an electrical charge from the motherboard? Thanks
@jesparza602
@jesparza602 Год назад
I've been looking for a video like this! As always, your explanations are clear and succinct. Thank you! Do you by chance have a book where you detail this?
@VictorGarcia-ri6uw
@VictorGarcia-ri6uw Год назад
Where can I buy the spark igniter wire?
@odishoodisho4904
@odishoodisho4904 8 месяцев назад
If the module go bad and need to be replaced should we have to look the same one or there is an universal will work with all models ? And it needs to do some changes or just we can put it direct without any changes thanks in advance
@edwardgarza5104
@edwardgarza5104 Год назад
Is there a step up transformer inside that board to be able to send 120 vac to the flame sensor?
@caru3257
@caru3257 Год назад
120v is present at the board and it doesn’t require a step-up transformer.
@mohammedalobaidi9981
@mohammedalobaidi9981 7 месяцев назад
👏👏👏
@RC-Heli835
@RC-Heli835 5 месяцев назад
My old 1986 System does not seem to have a flame rod. It just has the old school honywell intermittent igniter and sparker and the fan limit switch.
@Sightthrough
@Sightthrough Год назад
I'm curious about the voltage on the flame rod, when we test flame rods in the field we always measure the signal from the rod in Microamps DC, I didn't realize there was also A/C voltage on the flame rod, so the signal from the flame rod to the board is measured in microamps, DC, but the rod also has a potentially high A/C voltage on it? Could you share more about this?
@chrisdeanndavison3626
@chrisdeanndavison3626 Год назад
It is flame rectification. I know I'm not explaining this by the book, but basically, the AC voltage present on the flame rod is rectified by the flame to DC. It is just a phenomenon that happens when AC voltage is in a flame. The flame conducts a very small amount of DC current to ground, this is the uA DC that we measure. This is why the ground on a furnace is just as important as the hot and neutral. Also, rusty burners can inhibit the current flow. 14:30 Craig explains this pretty well.
@Sightthrough
@Sightthrough Год назад
@@chrisdeanndavison3626 Thanks! My fault for posting the question before finishing the video.
@coolramone
@coolramone Год назад
So there are ac micro amps AND dc micro amps running through the flame rod, and which one is being measured by the pc board, ac or dc?
@jynnandtonnyx
@jynnandtonnyx Год назад
@@coolramone the way I understand it is : there is AC power (different than voltage) available to the flame rod. When the circuit is closed by the flame, the AC power is rectified by the flame to a small DC circuit which can be measured in micro amps. The flame is the switch.
@rj.parker
@rj.parker Год назад
@@coolramone dc microamps
@eloy09
@eloy09 Год назад
I was troubleshooting a lochinvar water heater. Same principle though, what happening is it will prepurge and trial for ignition again and again. What should be the problem? No flashes
@Morbidhouse
@Morbidhouse 6 месяцев назад
I'm getting a voltage drop in the MC terminal, when the wire is connected to the gas valve it is only reading 15vac however when it is disconnected from the gas valve it reads 26vac. The pilot is sparking and lighting and blower is turning on however this drop in voltage seems to be preventing the burners from coming on. Would it be the gas valve or the ignition control module at fault?
@Purifiedinfire
@Purifiedinfire 6 месяцев назад
My furnace has a control board for everything. The inducer fan goes, the spark ignitor clicks, the gas valve opens in short few second spurts a few times but it won't light. While doing this the furnace clunks or clicks like a gas valve or relay. The best I can gather it's a rusty buner tube not getting ma back to ground or a bad ground and it cutting the gas quickly then retrying a few times before giving up for a few minutes. The part I don't understand is why the clunking or clicking. The furnace doesn't do this all the time just sometimes.
@light0000
@light0000 8 месяцев назад
Is it possible the flame sensor is bad and wouldnt let my HSI igniter to glow?
@imbobbymuddah
@imbobbymuddah 2 месяца назад
What about a faulty module? How can you troubleshoot for that
@user-jp5py6ry7t
@user-jp5py6ry7t День назад
When the AC voltage is sent down for the sparking across the the probes(or probe and burner ) to the ground to make the circuit , the flame sensing probe is also sending ac down to the flame to convert to DC for same ground to prove? Is the flame rectification proven after the sparking stops , like a window of time ? As it would be AC from the spark and DC from the flame proving or am I getting confused ? Or is it possible to sense both at the same time from the same ground ? Anyone’s insight is helpful tia
@user-jp5py6ry7t
@user-jp5py6ry7t 10 часов назад
8:17
@mplscarsales6652
@mplscarsales6652 Год назад
Hi my furnace always had at least 1 click I hear before start up and fan kicking on but lately I been hearing 2-3 clicks/Spark before the blower motor kicks on is that normal ? Same clicks I hear in your video at 8:16 but yours clicks/sparks much more .
@mrgibsoncat
@mrgibsoncat Год назад
hit it with soft sand paper
@windturbineclimber5412
@windturbineclimber5412 Год назад
How does it get up to 10000 volts?
@christiansnyder1746
@christiansnyder1746 Год назад
Craig I have a stupid question If there is only 24 V going to the ignition module, how does it produce high voltage?
@acservicetechchannel
@acservicetechchannel Год назад
There is a low voltage to high voltage transformer under the hood of the icm.
@dennisnoone7427
@dennisnoone7427 Год назад
why does a new ds845 dont have a terminal for fame sense anymore? the one you have still have one, but if i google for a new one it doesnt
@mr.spliffaddikts9548
@mr.spliffaddikts9548 Год назад
I have a question ?? Is there a device tool that a Hvac tech can u to plug on fan motor’s n control board to get a diagnosis besides a (multi meter ) to test all components
@mr.spliffaddikts9548
@mr.spliffaddikts9548 Год назад
It’s there any please link it to the comment section please n thank
@chrisdeanndavison3626
@chrisdeanndavison3626 Год назад
@@mr.spliffaddikts9548 The short answer is no, not really. Most furnaces for the last 30 years do have some sort of onboard diagnostics. When there is a problem, we count blinking lights on the control board and then find the key to what the blinking lights mean to narrow our search for the problem. However, some upper-end units do have more sophisticated means of diagnosing the issue. I service WaterFurnace geothermal units and use an Aid-Tool analyzer on the 3 Series and 5 Series units. Apparently, the 7 Series units can be diagnosed through an internet connection, but I have no direct experience with them. The analyzer can provide a lot of information about how the unit is operating and what issues it might have had or is currently having. Much better than blinking lights.
@zogonet
@zogonet Год назад
hello, can you provide Polisz subtitles on your channel
@EC20121
@EC20121 Год назад
Flame roll out switch, cannot find a replacement for mine, keeps tripping can you help me find a replacement for it? Thank you
@jimbarron8688
@jimbarron8688 9 месяцев назад
A flame rollout that is constantly tripping is usually a sign of a cracked heat exchanger and is very bad news. These switches are generally very reliable so you'd be fortunate if a replacement solved your issue. A CO detector near the burners when it's running might show high CO as would a washy flame pattern that rolls out when the main blower powers on.
@rodgraff1782
@rodgraff1782 Год назад
Are there manufactures who are still using DSI. I thought everyone had switched over to HSI quite a while ago.
@acservicetechchannel
@acservicetechchannel Год назад
Almost all manufacturers use it for outdoor package units, thanks!
@PBS-nm1uu
@PBS-nm1uu 5 месяцев назад
bad camera angle but good video
@EC20121
@EC20121 Год назад
Or why would it keep tripping?
@OneLeggedTarantula
@OneLeggedTarantula 8 месяцев назад
I didn't know they made these, but was just thinking what a waste of power the old glow ingiters waste.
@CecilMerrell
@CecilMerrell Год назад
Here is a great video that goes into detail about the flame rectification physics and how flames can act as a diode that basically makes a half wave rectifier -> ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-FjrzbqFDnAw.html
@CecilMerrell
@CecilMerrell Год назад
Additionally, looking into Townsend Discharge is an interesting physics rabbit hole.
@ausseamore8386
@ausseamore8386 8 месяцев назад
Далее
Камень, ножницы, нейронка
00:33
Просмотров 1,3 млн
Я читаю переписки сына
00:18
Просмотров 651 тыс.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 22 тыс.
HVAC Advanced: Triple Evacuation
6:54
Просмотров 10 тыс.
Mastering Gas Heat in 10 Minutes
32:32
Просмотров 20 тыс.
Honeywell Intermittent Pilot Training
14:15
Просмотров 84 тыс.
Gas Furnace Burner Training!
11:57
Просмотров 18 тыс.
Камень, ножницы, нейронка
00:33
Просмотров 1,3 млн