Тёмный

GST 200 | GST FIRE ALARM PANEL | GST FIRE PANEL |GST 200 FIRE ALARM TUTORIAL | 

FACP SOLUTIONS
Подписаться 350
Просмотров 3,6 тыс.
50% 1

#naffco #nfpa #fire #firealarm #fireandsafety #qatarfactory #firealarmpanel #firepanel #elite #elitefire #aramco #sibca #sosinternation #firealarmcompany #gst #gstfirealarm #gst200 #gstpanel #gst
gst fire alarm disable device
gst fire alarm enable device
gst fire alarm disable sounder
gst fire alarm view device
gst fire alarm view disable
gst fire alarm unknown device enable
gst fire alarm cause & effects

Наука

Опубликовано:

 

12 июн 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 25   
@PrabhakarSinghFunnyVlog
@PrabhakarSinghFunnyVlog 10 месяцев назад
Bahut badiya bhai
@dhananajayparsad8512
@dhananajayparsad8512 19 дней назад
Spinal ka pura fold check karna ho screen per Aata ho to kaise hoga
@susantkumarbeura5027
@susantkumarbeura5027 7 месяцев назад
Can we change the panel timing
@vijaypalsingh6254
@vijaypalsingh6254 Год назад
sir led ko zone ke according glow karna due to softwear plz
@FACPSOLUTIONS
@FACPSOLUTIONS Год назад
Do you know basic programming then I can teach you
@vijaypalsingh6254
@vijaypalsingh6254 10 месяцев назад
sir i know basic knowledge of programing
@vijaypalsingh6254
@vijaypalsingh6254 10 месяцев назад
sir you will teach iwill very kind ful to u thank i
@FACPSOLUTIONS
@FACPSOLUTIONS 10 месяцев назад
@@vijaypalsingh6254 send your email id
@vishnuvg6548
@vishnuvg6548 5 месяцев назад
Hi Sir,am facing one issue on delay,any zone fire PAVA modules to be active in 60sec,but these modules activates in 30sec
@FACPSOLUTIONS
@FACPSOLUTIONS 5 месяцев назад
Change program put delay time 6 than it activate on 60 sec
@vishnuvg6548
@vishnuvg6548 5 месяцев назад
@@FACPSOLUTIONS already given as 6,still activates in 30sec,when change to 0 activates in 0sec,but giving delay 6 or more than 6 activates on 30secs
@FACPSOLUTIONS
@FACPSOLUTIONS 5 месяцев назад
What about delay led it's on or not it should be on and do not test by MCP test by any other detectors
@vishnuvg6548
@vishnuvg6548 5 месяцев назад
@@FACPSOLUTIONS led is on tested with detectors also same issue
@FACPSOLUTIONS
@FACPSOLUTIONS 5 месяцев назад
Send your email I'd and I will share you meeting link
@JeromeOmbao
@JeromeOmbao Месяц назад
Sir how to delete modules
@FACPSOLUTIONS
@FACPSOLUTIONS 20 дней назад
Remove from loop and initialise the system
@nawazalam9146
@nawazalam9146 5 месяцев назад
Gst smoke detector me address kaise dalte hai
@FACPSOLUTIONS
@FACPSOLUTIONS 5 месяцев назад
Hand tool programmer se
@nawazalam9146
@nawazalam9146 4 месяца назад
Other ko aur option ho to sir bataye Hand tool programmer nahi hai
@rahulpatil5718
@rahulpatil5718 10 месяцев назад
How to delete detector?
@FACPSOLUTIONS
@FACPSOLUTIONS 10 месяцев назад
Bypass that detector and initialize the system
@user-gf9kb1gc1h
@user-gf9kb1gc1h 11 месяцев назад
Good morning, I want to buy a hand program, programming dongle, and software for the GST brand
@FACPSOLUTIONS
@FACPSOLUTIONS 11 месяцев назад
Good morning where are you from
@FACPSOLUTIONS
@FACPSOLUTIONS 11 месяцев назад
Software you can download from gst website it's free but for CRT card and hand programming tool you should contact with your current country supplier
@FACPSOLUTIONS
@FACPSOLUTIONS 11 месяцев назад
gst.com.cn/en/Software.asp
Далее
SIEMENS | SIEMENS CERBERUS | SIEMENS FIRE PANEL |
8:01
How to do programming of GST200 fire panel ?
10:55
Просмотров 29 тыс.
Moorings - Fire Alarm Training
24:45
Просмотров 41 тыс.
How to connect GST200 Panel with Repeater Panel?
10:03
Fire Alarm System GST-200
11:07
Просмотров 7 тыс.
SIMPLEX FIRE PANEL | SIMPLEX 4100ES | SIMPLEX PANEL
12:07
Собери ПК и Получи 10,000₽
1:00
Просмотров 2,4 млн