This video will help you to do complete GST 200 fire panel programming & commissioning with complete details like
1. Connection of programming cable
2. Autolearn process
3. configuration through software
4. Naming of devices
5. logics configurations
6. upload & download of data
7. Backup of all data.
Kindly subscribe to this channel for more videos & latest updates.

Хобби

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 59   
@sadanandkshatriya44
@sadanandkshatriya44 Год назад
This is a very helpful & only video on youtube that explains step by step guide for commissioning. I struggled a lot 2 years back to do this. Keep this work going brother, wonderful video. Thanks a lot 🙂🙂
@mohammedbasith8395
@mohammedbasith8395 2 года назад
Thanks for creating wonderful video... Your explanation is very clear... Keep it up and All the best 👍💯
@ibrahimsha1992
@ibrahimsha1992 6 месяцев назад
Great Work. Well Explained....
@vijaypalsingh6254
@vijaypalsingh6254 Год назад
its amzing video and salute
@shyamsharma8659
@shyamsharma8659 Год назад
wonderful video
@nileshpanchal5666
@nileshpanchal5666 Год назад
Nice explanation..
@mkb_videos
@mkb_videos Год назад
Great
@ananthvenkat2999
@ananthvenkat2999 Год назад
Thank you sir....
@mohammedbasith8395
@mohammedbasith8395 2 года назад
If u r free...Can you make one video for gst ifp-8 mimic panel programming.
@SatishKumar-dt4uw
@SatishKumar-dt4uw Год назад
Sir agar aap is video ko Hindi me bhi voice over kar de to bahut help or behtar hoga samajhne ke liye 🙏
@khue109
@khue109 Месяц назад
Hello, do we need to program the address for detector before programming on the panel? Thank you
@sanjugautam3635
@sanjugautam3635 4 месяца назад
Sir please solve my issue. When I auto learn the panel. Both the loop and the device are visible But only Loop One is visible in the laptop's software. How do I assign loop 2 in this condition? Please reply me what is the problem.
@SelvaKumar-vd1lx
@SelvaKumar-vd1lx 2 года назад
Hello sir, i need your help to connect 5 control panel. After networking all panels the equation are not functioning. Need your advice
@user-ee1ki5df6o
@user-ee1ki5df6o Год назад
Does the replacement need to be programmed and is the programming manual through the board or through the computer ?? Please answer me.
@mahalomgirhussin1208
@mahalomgirhussin1208 Год назад
Thank you so much. How to USB driver setup
@vishnuvg6548
@vishnuvg6548 6 месяцев назад
Hi Sir,am facing one issue,given delay is 60sec,any zone fire Pava Modules need to activate in 60sec,but those modules activates in 30sec,could u plz help on this
@bijumonbiju6225
@bijumonbiju6225 Год назад
Hello sir I have a doute how to create a equation of adjustion zone activation et zone 1 I have smoke and sounder and zone 2 I have one input moduled and a out put moduled. I need to activate when zone 2 activate zone 1 sounder should activate. Please help me
@olimohamed1578
@olimohamed1578 2 года назад
Hi How to auto reset the fire alarm when our panel received the fire alarm signal and if the mall panel is reset our panel also need to reset automatically..how to do it ...
@lalitsharma1018
@lalitsharma1018 11 месяцев назад
We are facing problem to connect laptop USB port to GST 200N system port. Showing yellow error in device manager. what to do?.
@RahulSingh-gq3up
@RahulSingh-gq3up 4 месяца назад
"There is no port" Proble showing in software when we click on COM set kindly give any sugestion
@janiceguadalupe8058
@janiceguadalupe8058 5 месяцев назад
Hi sir. System fault must be reset mannually. That is thee problem of my oanel. What shiuld i do
@facpinfo8640
@facpinfo8640 2 года назад
Can we write the location without pc?
@chennakesavarao3997
@chennakesavarao3997 11 месяцев назад
I have connected PA system in panel.When fire happens pa system not working.
@adamskibondo
@adamskibondo Год назад
Hello boss, I have a GST Jb-gb-gst1500h
@shahid8639
@shahid8639 3 месяца назад
Can anyone tell me how to tackle with ground fault in GST200
@subhamsingh1696
@subhamsingh1696 Год назад
When I restore back I will backup restore successfully software will be restarted after reopen software restore data not showing what is the reason behind that pls help
@safetytechchannel5694
@safetytechchannel5694 Год назад
Program card is available?
@sanjugautam3635
@sanjugautam3635 4 месяца назад
Hi sir
@vijaypalsingh6254
@vijaypalsingh6254 11 месяцев назад
sir zone wise led glow karna plz make on video
@ronaldsamarista4876
@ronaldsamarista4876 Год назад
Hi sir im from philipppines can iask where to buy that communicator card/download card?
@saravanamoorthy6892
@saravanamoorthy6892 11 месяцев назад
In Philippines dono... But it is available in chennai - tamilnadu- india, against order
@yogeshdabhi363
@yogeshdabhi363 6 месяцев назад
Can anyone tell me from where can I buy GST programming tool ?
@activetechnicalservicesats5184
How to set Address in Devices like 1,2 ,3 etc?
@starelectroline3960
@starelectroline3960 Год назад
Dear Sir please splean GST 200 ADDRESSBLE PANEL COMISSNING AND PROGRAMING Hindi language VIDEO
@electricalengineerb.b6010
@electricalengineerb.b6010 Год назад
Sir software kese download hoga
@gourabdhara6884
@gourabdhara6884 2 года назад
Sir plz tell me how to disable sounders?? Whenever I'm trying to disable all sounders it is showing on the screen "Please wait". After that disable LED not glowing.
@gourabdhara6884
@gourabdhara6884 2 года назад
I'm speaking of GST-Ifp8 panel disable sounder option
@Lowvoltage
@Lowvoltage 2 года назад
Press Button 8 (enable/disable) - give password as 11111111 - enter - press 1 for disable device - press 3 for all loop sounders - it will ask the panel address - give the 3 digit panel address - enter. We will get a display as "success" in the panel and disabled and sounder flt/Dis led will glow permanently.
@gourabdhara6884
@gourabdhara6884 2 года назад
Sir I tried by this only. But it is not happening. I can't share you image here. Kindly give me your mail Id Then I can show you how exactly it is happening
@safdarhusain5233
@safdarhusain5233 2 года назад
Due to water leakage on 2nd floor, display of GST 200 panel at ground floor is empty, showing nothing any text on display but only light, no 24v power on loop out /loop in point even loop wire disconnected. What will be reason and how to troubleshoot it
@Lowvoltage
@Lowvoltage 2 года назад
If we confirmed as water entered into the board, first we need to check which part of the board is damaged and then it need to replace. If it is not visible, first we need to check the pins in the power supply board's output voltage and then the pins where these power supply terminals are connected. Mostly, when there is any issue on the main board (the PCB board on the back side of the front door), this display won't come.
@JharGyanDarpan
@JharGyanDarpan Год назад
PART CODE MB-221N. Will hv to replace...Or repair if possible..So maney panel hv same problem, nd I spoke it
@viveksharma9088
@viveksharma9088 2 года назад
how can I use dalay time in this
@Lowvoltage
@Lowvoltage 2 года назад
When we create the equation, in the effect Device, we have the option to set the Delay Time in seconds.
@umarmohammad4166
@umarmohammad4166 2 года назад
respected sir I'm you subscriber please help me I'm leaving Mumbai I want to purchase this card rs232 .how much
@sagalakalatamizhan4837
@sagalakalatamizhan4837 Год назад
Autocheck port successful but uploading device error comes can help me
@yanoosayaa8741
@yanoosayaa8741 24 дня назад
I also have this problem
@boxervignesh
@boxervignesh Год назад
How to reset the panel password
@srinivasasubramaniyan8117
@srinivasasubramaniyan8117 2 года назад
Sir how to set equation for main gate sounder as common where other area sounders should work as zone wise sounder
@Lowvoltage
@Lowvoltage 2 года назад
First, we need to assign this sounder as a seperate zone. Then, along with zone wise equation, we need to create one more equation as (in condition device) "any zone, any device activate - (in effective device) this perticular sounder zone with device type as sounder.
@mikemakokha8931
@mikemakokha8931 2 года назад
Hi am trying but it's not uploading but it's downloading please help
@sagalakalatamizhan4837
@sagalakalatamizhan4837 Год назад
Same problem I am facing can u help
@prajwalshinde5098
@prajwalshinde5098 4 месяца назад
Same problem I face can you help please
@cloud30yt
@cloud30yt Год назад
what will happen if it becomes upload error
@yanoosayaa8741
@yanoosayaa8741 24 дня назад
I also have this problem
@prajapatkamleshact8939
@prajapatkamleshact8939 3 месяца назад
Sir apke contact number mil sakte h kya
@mohammedbasith8395
@mohammedbasith8395 2 года назад
If u r free...Can you make one video for gst ifp-8 mimic panel programming.
@shyamsharma8659
@shyamsharma8659 Год назад
Hello sir, i need your help to connect 5 control panel. After networking all panels the equation are not functioning. Need your advice
Далее
How to connect GST200 Panel with Repeater Panel?
10:03
ELA NÃO ESPERAVA POR ISSO 🥶 ATTITUDE #shorts
00:20
Наташа Кампуш. 3096 дней в плену.
00:58
5 Story Building - Backbone of the SLC
7:09
Просмотров 39 тыс.
How To Program A Device In On The Notifier NFS2-3030
6:41
Why The Windows Phone Failed
24:08
Просмотров 233 тыс.
How the Best Hackers Learn Their Craft
42:46
Просмотров 2,5 млн
How to do programming of GST200 fire panel ?
10:55
Просмотров 30 тыс.
How do Smoke Detectors Work
6:49
Просмотров 294 тыс.
ТОРТ ИЗ АРБУЗА С ГУСЯМИ🤪🍉
1:00
Пёс - Парашютист 😍
0:42
Просмотров 3 млн