Тёмный

Heat Geek Mini Store: Is It a Good Fit For Your Home? 

Urban Plumbers
Подписаться 40 тыс.
Просмотров 34 тыс.
50% 1

#heatgeek #ministore #renewables
In this video, we are running a long-term test of the Heat Geek Mini Store XS with a Vaillant Arotherm Plus 5kW heat pump.
Is the Heat Geek Mini Store a viable solution for your home and can it replace a full size hot water cylidner? Watch the video to find out.

Опубликовано:

 

12 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 131   
@gibbodive140
@gibbodive140 25 дней назад
Hi Szymon. A good well balanced presentation. Someone questioned your objectivity in the comments which I felt was unfair. I like to see balanced review that points out the possible drawbacks as well as the positive points and you absolutely nailed this. E.g You questioned performance in the winter which was one of my immediate thoughts. The SCOP was compared with the large cylinder and "managing expectations" was mentioned. It might be nice to have some figures on the various scenarios you demonstrated at some time in the future in both the summer and winter conditions. Finally, I learnt from this as well (new to heat pumps). It all well and good doing the theoretical courses but the practical applications you demonstrate are invaluable. Thank you
@970357ers
@970357ers 25 дней назад
A test showing how two of these could be combined for a larger volume/more economical performance would be good. I have two ‘blind’ corners in my kitchen that they could go in.
@normanboyes4983
@normanboyes4983 24 дня назад
Well done Syzmon - excellent practical analysis and demonstration. I think your caveats will be completely overlooked/ignored by the critics. In sum this is a practical alternative for those who absolutely do not have the room for a conventional unvented cylinder of a capacity suitable for the dwelling. If one has the room for a conventional cylinder then deciding to fit one of these means you are accepting all the performance and efficiency compromises that come with it.
@killercarpcatcher
@killercarpcatcher 25 дней назад
Great video, as always. Nice to see another option become available. Just like every other technology, as time goes by, more options appear, and costs go down.
@mentality-monster
@mentality-monster 25 дней назад
Thank you for the video. Looking forward to the winter tests.
@missingtale
@missingtale 22 дня назад
Great ballanced video, im suprised by the number of comments that have missed the fact this is the smallest in a range and larger devices that exist and should be used for larger properties. Sounds like it would be fine in a tiny flat with only a shower but if you want a bath you are going to be compromised, try to fit one of the bigger versions. What is the best strategy with these, fit the largest you can?
@alltechinbox
@alltechinbox 25 дней назад
An ideal partner with a thermostatic shower & waste water heat recovery? A further bonus is no legionnaires cycle needed as the water is direct
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
yes, heat recovery is a good shout for the mini store
@tlangdon12
@tlangdon12 25 дней назад
It's certainly an ideal unit for a small flat that already has an electric shower and only needs hot water for washing hands and dishes.
@DavidWillis-s4c
@DavidWillis-s4c 25 дней назад
Try it with a waste water heat recovery unit may get some extra duration of hot water flow
@AdrianColes
@AdrianColes 24 дня назад
Any recommenadations for low flow shower heads and where to get those flow restrictors?
@darylfortney8081
@darylfortney8081 25 дней назад
love those steampunk polished brass pipes... this setup is practically a work of art. please come do the plumbing in my condo
@michaelridley2864
@michaelridley2864 24 дня назад
Great test with a really clear explanation of the pros and çons, thank you
@derekclark7545
@derekclark7545 24 дня назад
If there were 10,000 people like you and the other Heat Geek assured installers, we would be well on our way to reaching the UK's target for ASHP installations. Three years back I installed open vented, indirect, 600x300 high recovery cylinder on a 12KW Glowworm energy boiler, they only had three hot water taps and an electric shower, the boilers on 24/7 for hot water on a Glowworm weathercomp system, the three of them in the house cannot get it to run out of hot water or run below 45 degs. Once people have had a high recovery cylinder fitted they love it, it always has hot water like a combi boiler if hot water priority controls are fitted its very fuel efficient, what more could you want.
@jakeii9
@jakeii9 23 дня назад
Why don't Heat Geek folks ever mention heat batteries from the likes of Sunamp? Solves the same problems that the Mini store is trying to, but can store way more heat in the same/less space.
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
Requires even higher flow so is even less efficient than ministore XS.
@jakeii9
@jakeii9 22 дня назад
@@UrbanPlumbers I see! Maybe they could be collaborated with to have wider bore pipework in their loops to lower flow rates!
@UrbanPlumbers
@UrbanPlumbers 21 день назад
@jakeii9 it’s about flow temperature not flow rate
@deanjesper1951
@deanjesper1951 24 дня назад
What's the performance like between the Mini Store XS and the Mini Store TALL? The tall having a capacity of 110L, would it be more efficient?
@noebory
@noebory 25 дней назад
What about the temperature of the space heating in winter? Does it drop a lot when you puncture heat for the mini tank for long bath? Can people feel it in the house? Or is the inertia of the building act as the buffer?
@FrankReif
@FrankReif 23 дня назад
Honestly, I think we need to rethink how we design shower enclosures. If they were enclosed with minimal air changes, the amount of heat you lose to the rest of the bathroom would be significant. Also, integrated hydronic heating panels would help. Low flow isn't an issue if you're warm.
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
Low flow isn’t an issue with correct shower head . Most people use way too much water for no reason.
@FrankReif
@FrankReif 22 дня назад
@@UrbanPlumbers I really just want to become Finnish. They all have their own sauna. 3million saunas, 5.5million people.
@jakop0815
@jakop0815 25 дней назад
When ever possible use a full size cylinder, much more efficient. If ready no space at all maybe consider a minstore, but also think about direct electric water heater ( after the ministore?)
@heatpump8566
@heatpump8566 20 дней назад
This needs revisiting in January tbh.
@UrbanPlumbers
@UrbanPlumbers 19 дней назад
I will be!
@NewarkCylindersMarketing
@NewarkCylindersMarketing 23 дня назад
Further details about the Heat Geek Mini Store can be found on our website.
@alimack5489
@alimack5489 20 дней назад
In the situations like a flat wouldn’t it be more viable and simple to stick with an electric shower? Possibly a small under sink water heater for washing up / basins. That removes the need for any stored hot water and prevents the cycling of the heat pump on its CH. you can always upsize the shower for a better flow rate. Unless im being thick as usual. Also I didn’t expect you to have one of those shower heads 😂
@davecavaghan7889
@davecavaghan7889 25 дней назад
How many outlets can it run at the same time?
@brianwood5220
@brianwood5220 25 дней назад
Thanks Szymon.
@jfinnie78
@jfinnie78 24 дня назад
Bit concerned this could result in people being put off heat pumps even more. It seems just about good enough for a reasonable length shower at an economy that is somewhat worse than gas - as you can't choose when to recharge. I really struggle to see these as replacements for combis in all but small flats without a bath tub.
@UrbanPlumbers
@UrbanPlumbers 24 дня назад
There is a bigger version of this store that allows full flow and a bath as well - it still fits under the worktop
@jfinnie78
@jfinnie78 24 дня назад
@@UrbanPlumbers Do many flats have room in their micro kitchens to lose an under worktop cupboard? I'm not so sure.
@rkob1
@rkob1 25 дней назад
Another good video, can also see uses for this with a gas boiler in areas difficult to get discharge pipework to outside.
@ram64man
@ram64man 25 дней назад
hmmm maybe a good idea for a single person or under sink tank with main elsewhere to get around flow rate s not affecting the main shower etc, , but for a family a definite miss, further more just 5litres per min even 10 is quite slow given existing gas and 140litre can flow typically 20 literes with a 22 min recharge on 25kwh its going to be tough sale, convincing customers who may be migrating, i would still stick with a higher capacity cylinder with 50mm with a heat pump
@markellse
@markellse 25 дней назад
A small storage tank is the wrong solution for pairing with a heat pump, but fine with something like a gas boiler with an output 12 kW. The boiler can recover at the rate of 4 litres/minute but the lower power of a heat pump, perhaps less than 7kW in winter, means that recovery is down to about 2.3 litres/minute - insufficient for peak hot water usage times unless you are a one-person or frugal-two household. With 3 beds, design for 4 people, assuming that 200 litres is needed in half an hour (4 showers or 1 bath and 2 showers). Multiply your recovery power, 7kW in this heat pump case, by 10 to give the recovery in half an hour. That's 70 litres for this heat pump. So the storage needed = 200 litres - recovery = 200 litres - 70 litres in this case = 130 litres. If you've got a 12 kW gas boiler, recovery is 120 litres in half an hour so storage required = 200 - 120 = 80 litres. (Priority Domestic Hot Water is, of course, needed.) If' you've got a 30 kW combi, that will provide 300 litres in half an hour, you need no storage. But, as the article says, shower design is important. Drench showers, the current fashion, can use 15 litres/minute and demand wastefully large hot water systems. Aim for 6 litres/minute. the current recommendation for government buildings. Your teenage children will indeed spend 10 minutes in them, consuming 60 litres each.
@JerzyJuszczynski
@JerzyJuszczynski 25 дней назад
Thanks for your time spend on testing the Ministore. During the tests did you come up with any correlations between DHW flow, store high limit temperature and the size of the vessel to use as kind of formula? Do Heat Geek guys have any, as Newark guys do not. I have spoken to Adam B. from Newark and not only ordering now any Thermalstore cylinder/buffer it will not be ready before mid November but also they have no data or a solution how to calculate the variables to make a right choice. Let's say if you had double the size of the vessel(or triple) how that would perform? I like the idea but I don't want to order now to be able to start testing the cylinder in mid November to find out if my choice was the right one, to fit it for the customer after all. Finally if the customer have a space for DHW cylinder would you still fit one (Supercylinder) or have gone for Thermalstore to eliminate the G3 regs and Water regs in terms of Legionella Great work Simon😊
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
I would fit unvented if there is space
@JerzyJuszczynski
@JerzyJuszczynski 24 дня назад
Thank you very much.
@Angel_VR18
@Angel_VR18 20 дней назад
Great video Szymon, I seen on your sensocomfort you had legionella cycle off, do you think it’s pointless to have this activated in domestic property’s with a correctly sized cylinder.
@UrbanPlumbers
@UrbanPlumbers 19 дней назад
defintiely not needed with heat stores!
@matthewgreentree425
@matthewgreentree425 25 дней назад
Surely, the best option would be to do away with the cylinder and install a full size ‘thermal store’ where you have the space. You could then heat the store to a higher temperature and install a blending valve on outlet. You would need to ensure high insulation factor on thermal store to maintain as high a temperature in thermal store as possible. As it is not unvented, no G3 qualification required
@EdthePlumber
@EdthePlumber 24 дня назад
Think you missed the point of this product, it’s to fit in spaces where you can’t fit a full cylinder, they also sell larger ones too
@SmartLifeEnthusiast
@SmartLifeEnthusiast 25 дней назад
6:55 Does that showerhead really does what their commericals promise re. the beads cleaning the water? And does the housing get dirty/cloudy?
@richarddicktaylor219
@richarddicktaylor219 25 дней назад
I have really enjoyed watching your videos especially those about heat pumps and systems like the mini store. However, we have two properties; a 1930s listed flat in central London where we can't install a heat pump and a small 1br cottage in the country where there is only electricity (an electric shower & 3 radiators) but I'm not sure the cost of a heat pump and tiny cylinder makes much financial sense. There must be hundreds of thousands of flats and small houses like ours, but every video about this tech never addresses the challenges of listed properties or rural ones where there is not even any signal for a smart meter.
@stephenhall1774
@stephenhall1774 24 дня назад
But this is the smallest one in the range (60L). For a typical semi, I'm more interested in how the larger ones (110L) perform compared to the Heat Geek/other cylinders which start at 150L. A cylinder about 1m tall is better than one about 1.5m tall if it can fill a bath and give a decent shower.
@chrispruden3570
@chrispruden3570 23 дня назад
If you have a medium sized house and need capacity for regular baths and consecutive showers would two mini stores in two separate locations be a viable solution if there's no room for a full size cylinder?
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
Get a regular size mini store - it’s double the size of XS
@noebory
@noebory 25 дней назад
I did not understand why you have less pressure than a classic DHW boiler? You should have the pressure of the domestic water network (between 4 and 10 Bar in Switzerland). Is it because of the pressure drop of the large heat exchanger inside the cylinder? Or is the pressure vessel tank with the larger boiler works as a sub-network increasing the observed pressure?
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
You can have as much pressure as you want. It’s just the flow rate needs to be limited otherwise you run out of hot water quickly
@nickannalloyd4393
@nickannalloyd4393 22 дня назад
Thank you for the video. I am curious about what you think about the Ministore FAT which is seems to ideal for going under a cupboard, and whether that will do what is needed for us. Deciding tonight whether to go for the ministore or a Mitsubishi which my installer is pushing. The FAT has nearly double the volume of the model you were suggesting does that resolve some of your concerns?
@UrbanPlumbers
@UrbanPlumbers 22 дня назад
is it a mitsi cylinder or heat pump? I do not rate Mitisi at all, not my cup of tea.
@nickannalloyd4393
@nickannalloyd4393 18 дней назад
@@UrbanPlumbers We are being recommended both as a combined solution. There seems to be a lot of negative about Mites on the forums.
@UrbanPlumbers
@UrbanPlumbers 17 дней назад
@@nickannalloyd4393mitsi to heat pump is what worcester Bosch is to boilers. Cant say any more really
@aerenewables
@aerenewables 23 дня назад
great video. is that app available for other heat geeks to use ??
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
Last time I asked Adam he said it would be once it is finished.
@deanofakesie8153
@deanofakesie8153 23 дня назад
genuine question , why not just install an electric shower and instantaneous water heater for the sinks, or would that use more energy
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
You can - it would require 7-9kw power which is a lot and also would be 2-2.5x more expensive to run
@darrankelly4963
@darrankelly4963 24 дня назад
As a refrigeration tech I'd advide highly against "setting your anti-cyle to zero". Thats a fast track to compressor failure.
@UrbanPlumbers
@UrbanPlumbers 24 дня назад
That’s only 5-10 cycles a day of 10min. Not ideal but a lot of air con or heat pumps cycle more than that.
@jfinnie78
@jfinnie78 23 дня назад
It's not that simple though, is it? I think there are reasons you don't really want the compressor to be starting when it may already be hot from having just been run (eg bad timing means the heating just cut off). You really want the compressor to shut down and cool down / pressure to equalize before it restarts to minimize wear on it and have efficient starts. That's my understanding, anyway.
@richardbeard4146
@richardbeard4146 22 дня назад
How much better performance would you expect if fitted with a 12kW Arotherm plus?
@UrbanPlumbers
@UrbanPlumbers 22 дня назад
yes of course.
@jfinnie78
@jfinnie78 18 дней назад
How much sense does it make? If the heat pump required is 12kW, that implies a pretty huge place. Seems really unlikely you need a 12kW heat pump for space heating yet a mini store is acceptable for hot water, even with the higher output of the heat pump.
@UrbanPlumbers
@UrbanPlumbers 18 дней назад
@jfinnie78 well, i chose to live alone in my 12 bed mansion - i don’t really like other people outside of YT
@RiouInsuiko
@RiouInsuiko 25 дней назад
Looks like you need to get in touch with the Coolgeeks as well! Looked like you were sweating your balls off there up in the office!
@leestaps
@leestaps 22 дня назад
So if you move to the next size up should be fine ?
@UrbanPlumbers
@UrbanPlumbers 22 дня назад
yesh 110l will be pretty good.
@luisenthal
@luisenthal 25 дней назад
So every time you use hot water the heatpump needs to turn on? Doesn't sound too good for the pump...
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
5-10 times a day for us on average. Not every time you use hot water, just when the store temp drops by 3-4c which will take few minutes
@JohnR31415
@JohnR31415 25 дней назад
Any plans for a cylinder with a condenser inside, to be used with otherwise A2A systems?
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
I think that they are already available?
@Belrmar
@Belrmar 25 дней назад
They are, and work pretty well​@@UrbanPlumbers
@radfoo
@radfoo 25 дней назад
Thank you for the video. I liked the idea of the mini store, i thought it could work for me as have a 3 bed house with varying demend for hot water (currently on a combi). 40% of the time its just me but the other 60% of the time have 2 children here using lots of hot water. I'm thinking the 130l version might be better for me, but of course the reheat time would be longer, so maybe then i'd be losing the main benefit of the store? Is the scenario for the bigger stores they they would be paired with bigger heat pumps? Ive done heat loss calcs and its close between getting a 5 or 7kw vailant so maybe a 5/7kw would just take too long on the 130l one?
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
3 bed house surely has space for a full size cylinder? This is designed for flats. Get a full cylinder if you can.
@radfoo
@radfoo 25 дней назад
@@UrbanPlumbers Thank you for the reply. Yes, I can fit a cylinder in but was attracted to the re-heat time and the change in demand (due to the varying occupancy of the home). If were to get a full cylinder would have to spec for the maximum occupancy and would end up wasting energy heating more than I needed when they weren't here. I guess this isn't the use case the store was designed for but thought it could work. Perhaps I am mistaken? When would you use the 130l mini store?
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
@@radfoo go for a full-size cylinder. When use is lower charge the cylinder to 42C as it will be all you need. Standing loses at that temperature are so small you can ignore them. Mini Store is really not a patch on a full cylinder in any size. It is a solution, when you don't have the space.
@waqasahmed939
@waqasahmed939 25 дней назад
​​​@@UrbanPlumbersAnd terraced houses I imagine. My parents have a mid terraced house Realistically the way they could therefore go fully electric is to get AC (for air to air) assuming they get planning permission , and to use these mini store heat stores. Kinda cool for niche applications It'd be cool to see what the COP is in winter. It'd be nice if they could get to a COP of say 3.5+ though purely because then it'd be cost efficient too to go fully electric.
@radfoo
@radfoo 25 дней назад
Thanks, I am sure you are correct. Just have to remember to switch it each time. Would still be nice to understand how/why/when you would use the 130l version and if there are any advantages or if it is even practical in the scenario I suggested. I'm perfectly happy with the idea of a heat pump, convinced it would work in my home (done the heat loss etc) but going from a combi from a hot water perspective is a bit of a fear and hoped/thought this might work with the quick re-heat times. It is miserable when you run out of hot water.
@audigex
@audigex 24 дня назад
For me this is too far into "managing expectations" - although I can see the utility of it for eg pre-heating water going into the cylinder at night or something to that effect. It might not run a whole bath, but it can be supplementary heat
@pf888
@pf888 25 дней назад
Can a Mini Store work with a gas system boiler if so what are the advantages?
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
Would work very well with a gas boiler. Ultra quick recovery and great flow rates
@GavinGrantUK
@GavinGrantUK 24 дня назад
I'm considering a heat pump later down the line. Would this work well with a combi? (obviously a bit unnecessary!) I suppose I could lower the flow temperature and rate range the DHW power output down to emulate the future heat pump?
@ericritchie6783
@ericritchie6783 25 дней назад
My showers do not use 3kws a day you. 2kw electric shower would be adequate, mine has a 0, 4 and 9 kW setting and the temperature dial is actually a "flow" dial... Because lower flow is higher temperature for a given power... I actually have to constantly switch between 4 and 0 to get the temperature at the modest flow I want, so a 2kwh shower would be better. I only need as little as 5lts, can be more if wanted but not needed. I can't believe you just assume people need 3kwh a day to shower. I only use around 1.5kwh a day averaged out for everything. I even converted a chest freezer into a chest fridge which is way more efficient for basic refrigeration needs just because it opens at the top not the side.
@andrewkelly1485
@andrewkelly1485 23 дня назад
Hey Symon. So its not about the design or install If it doesn't pass the wife test then it's too much a risk 😆
@jonjohnson2844
@jonjohnson2844 25 дней назад
I hope you're being objective seeing as Heat Geek is your mate!
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
I was not expecting it to perform at all to be honest. I thought it was just a PR stunt. It works fine, but I would still go for the full cylinder for the reasons explained in the video.
@jonjohnson2844
@jonjohnson2844 25 дней назад
@@UrbanPlumbers I suppose for washing up it's fine, but we all wash every day (I hope) and yeah it obviously doesn't have the capacity for a bath or a family having a shower
@UrbanPlumbers
@UrbanPlumbers 25 дней назад
@@jonjohnson2844 showers only and up to 10-15min max with limited flow with 5-7 min breaks between the showers will work fine
@jonjo6886
@jonjo6886 25 дней назад
You are so lovely.
@nickflynn666
@nickflynn666 25 дней назад
Unexpectedly negative review given the awesome potential of this thing. If you want a higher flow rate for a shower couldn't you just make the immersion do more of the work? It also seems this would work well with a waste heat recovery unit on the shower to enable a higher flow rate. Like you say its not as efficient as a full size cylinder but this is the first option I've seen that would make me want a heat pump in a flat. Combi boilers rule in flats as space saving really matters. I'm always amazed by people who haven't ripped out their old cylinders / system boilers.
@tlangdon12
@tlangdon12 25 дней назад
The issue for flats will come when gas combi boilers are no longer available. As you are aware, flats can be very short of space. This ministore seems ideal to fit into a dead space in a kitchen of a flat - I have a flat with such a dead space that is right under the existing combi boiler.
@StephenLewis-m5s
@StephenLewis-m5s 25 дней назад
Everything I see on heat pumps suggests you need to be a technical geek always adjusting things to use them. I want to replace my storage heaters with modern high heat retention heaters. The company contracted under the HUG scheme are suggesting a heat pump. I'm dubious because its all so complicated!
@BenIsInSweden
@BenIsInSweden 25 дней назад
For most it's set and forget, this is more about putting the smallest store through its paces to see its capabilities. For replacing electric store heaters, you're almost always better off getting an Air-to-Air system (Toshiba Haori is very popular in the UK). As retrofitting an entire wet system for an air-to-water heat pump will be pretty costly. You won't get the grant for an air-to-air system, but won't have to pay VAT and they're generally cheaper anyway.
@pumpkinhead456
@pumpkinhead456 25 дней назад
You're watching a video by an installer mainly for installers. I've not changed the settings on mine for a year and it's perfect!
@StephenLewis-m5s
@StephenLewis-m5s 25 дней назад
@@BenIsInSweden thanks, but if they do install a wet system then there’s no cost to me as I qualify under the HUG scheme due to low income, no gas and EPC of D. I haven’t seen the details yet of what they’re proposing. I asked for an update as the survey was back in May. They told me it has to be signed off still, but are looking at heat pump, solar and extra loft insulation.
@BenIsInSweden
@BenIsInSweden 25 дней назад
@@StephenLewis-m5s oh, that's interesting, I wasn't aware of the HUG grant, and that it would include a whole wet system retrofit. That's probably your best option then.
@Apexplumber
@Apexplumber 23 дня назад
Not convinced. If it had an ideal badge on it we’d all be laughing our heads off at it.
@UrbanPlumbers
@UrbanPlumbers 23 дня назад
Well, ideal heat pump looks pretty decent, so they may have the last laughs - again!
@Biggest-dh1vr
@Biggest-dh1vr 21 день назад
The specs are public, so presumably they could badge this up.
@matthewgreentree425
@matthewgreentree425 25 дней назад
This is nothing new, Gledhill have been doing this for years
@UrbanPlumbers
@UrbanPlumbers 24 дня назад
Not with this size coil and connections
@davidanthony6575
@davidanthony6575 19 дней назад
Sounds awful to be honest , 5 litre per minute in a shower is lit getting peed on.
@UrbanPlumbers
@UrbanPlumbers 19 дней назад
It’s fine with correct shower head. Probably something we should be doing anyway.
@robin5215
@robin5215 25 дней назад
seems like a lot of kit installed to get rid of a gas boiler.... strange?
@tlangdon12
@tlangdon12 25 дней назад
A air-source heat pump unit outside and a small tank inside isn't a lot of kit!
@MrButuz
@MrButuz 25 дней назад
Let me guess the fancy pink cylinder its another thousands pounds on top of all the other thousands you've spent, just to still not do as good a job as a 10 year old combi boiler?
@twelvebears1971
@twelvebears1971 25 дней назад
If you want to make snide, uninformed comments about something you haven’t bothered to learn about, perhaps you should stick to posting on X
@ponchod2924
@ponchod2924 25 дней назад
You keep your combi and spend lots of money on gas
@Mark-ob9bk
@Mark-ob9bk 25 дней назад
He has a point. It will take you 10 plus years to get your money back. Thats even if its installed corretly!
@thesquirrelhorde
@thesquirrelhorde 25 дней назад
@@Mark-ob9bkhow long does it take to get your money back on a new gas combi boiler?
@Mark-ob9bk
@Mark-ob9bk 25 дней назад
@thesquirrelhorde Alot quicker than an ASHP.
@ashleydines144
@ashleydines144 24 дня назад
Ballshit baffles brains. Heatpumps working over 35 deg become way less efficient. Install cost is high. Electricity is more expensive than gas. Electricity to run is from the supplier which is from a gas or coal generator. What's the point? Electricity run over power cables drops massively and is inefficient. Hydrogen in the form of a cell is way way more efficient. Please push that technology as a smart guy and inovator. I have faith in you. Green Hydrogen is cheap in hot countries but that will hand power to them. Please push technology not politics for humanity
@UrbanPlumbers
@UrbanPlumbers 24 дня назад
Sorry mate - but you have zero clue what you are talking about. Hydrogen would be Around 8 times less efficient than heat pumps. It’s a luxury gas that is very difficult and inefficient to produce.
@ashleydines144
@ashleydines144 24 дня назад
It's not difficult to produce. I used to work on a plant that produced it. It is produced in very sunny countries as the use of pv panels makes it very cheep. It can then be stored as a cell to avoid wasted gas escape. What country are you based? I'm from the UK and we use 40 percent fossil fuels for our power supply, 8 percent of our energy is lost when being sent to us. How is hydrogen 8 times less efficient?
@chujciwnery
@chujciwnery 24 дня назад
14:14 You meant to say "half the efficiency and double the running costs", right?
Далее
Micro-bore Pipework & Heat Pumps: How To Make It Work.
11:04
Heat Pump Retrofit in a 1980s House: What's Involved?
17:17
How Developers Are Ruining The Heat Pump Market
20:28
Просмотров 111 тыс.
How We Generate The Most Efficient Hot Water On EARTH
12:49
This Insulation Secret Will BLOW YOUR MIND
16:56
Просмотров 160 тыс.
500% Efficient Heat Pumps - Are They Real?
16:34
Просмотров 55 тыс.
Design Heating System Pipework Like a Pro
15:12
Просмотров 21 тыс.
How This New Heat Pump is Genius
18:03
Просмотров 873 тыс.