In this video, you will learn how to change the 500 lux default value in the room and how to add more calculation surfaces in one room. Please also help me find a way how to install the Dialux evo 6.1 in my windows 10. Thank you!
I would like to suggest this for now, to try and fix your installation problem (Directly from google) You might want to access the folder to do these: To check the permission of the file or folder, follow these steps: Right-click the file or folder, and then click Properties. Click the Security tab. Under Group or User names, click your name to see the permissions you have. If not, then enable it. Also make sure the file you downloaded is not corrupted.
Hi Nelca , learning lot from your videos. Could you please explain how to prepare documentation and add false color rendering and layout plan with dimensional detail of luminaires so that report should similar with DIALux 4.13.Thanks
It's rely nice video collection I enjoy it ,will you help me, I have a room 5m* 6m I need to find nos of lights required and space between them as well as the watt (W),the hight of room around 3 mtr lights used LED type
Hi Nelca, very much greatfull to you. During lockdown you were my friend in learning of DIALux evo & still i am in lockdown with you.😍 I am facing a problem. Can I remove the positive signed value (+200 +340) which are showing after simulation. I just want to get the average lux value which are shown without positive sign(200 300). Can you please help me???
Hola Nelca Felicitaciones por todo tu trabajo , los tutoriales que haces de Dialux EVO 6 son de mucha utilidad para mis trabajos de proyectos. Necesito que me orientes con respecto a copiar varias plantas partiendo desde la planta baja , lo he realizado , copiando todos los elementos pero cuando estoy tratando de modificar algunas superficies de la segunda planta , asi como eliminar puertas y ventanas , no me deja el programa y me lo cierra, he echo varios intento, pero han sido fallidoscerrandose el programa y atrazandome el trabajo, además he optado por otras variantes como duplicar los Dialux tratando de independizar las plantas para reportarlas independiente, y no me permite eliminar puertas, ventanas y recortes de la planta baja, cuando lo intento se me cierra el programa de nuevo , por favor puedes ayudarme en ello, te lo agradecería inmensamente ya que lo que he aprendido hasta este momento de Dialux ha sido gracias a tus tutoriales pero sobre este tema no has hecho incapié , si es verdad que he visto un tutorial en lo que explicas como duplicsr plantas pero solo copiastes la planta como base y no con todos los elementos , ni modificando espacios , además he revisado la posicion de cada elementos utilizado tanto luminarias , como muebles etc. por si se me ha pasado algo o he puesto elementos donde no se debe, pero nada todo está bien , así que sólo falta esperar por tu buen ojo y la experiencia. Muchas gracias por todo y ánimo para que continúes ayudando como lo haces con tu canal de youtube. Un saludo caluroso Mabel
Hi Nelca, I have difficulties how to insert high bay light fixtures on objects like pillars and walls.Therefore,how to get the 700 lux by use type of light watts.This is for outdoor and building planning.Could you guide me.Thanks.
Hi Nelca... just a quick query... Where do you input the ceilng, wall and floor reflectances in Dialux Evo? Is there any default value in the software for each room type in the pull down menus of types of space or room? If so, can this be edited?
yes. there is default value. i think the default is 80, 50, and 20. Go to materials tab, select change reflectance of room surfaces, from there u can edit the room reflectances. let me know if u cant find it.
Hello. Thanks for the video. I'm still wondering how to set a Target Value for a Calculation Surface. I know how to set Target Values for Spaces, but not for separately drawn Calculation Surfaces
Hi Nelca, I think you should press left click on the mouse - then --> Run As Adminstaritor, or it might be also the Antivirus preventing you from running the software. Let me know if it worked !
How reliable are the calculations with DIALux? From what I recall, the default work plane is situated 0.8m, right? Will you have an impact on the result if you put the work plane on the floor? What instances have you encountered that a work plane for calculations was ever situated flat on the floor? Thanks in advance.
Yes, the default is 0.8 in Dialux evo. Yes, there is impact on the result because the farther the calc plane in the luminaire the lesser the output. It will be 0.0m cal plane or floor level if the area or room is in (for example) corridor, lobby, general areas, storage rooms, electrical room, mechanical room, etc. anything that doesn't have tables that task working plane is considered. I hope it helps.
I've tested it and feels like the difference is quite insignificant, don't you think? About 1-10 lux difference (considering it's not an emergency lighting)
Yeah, not that much. But that 1-10 lux is a big deal for a very sophisticated consultant or architect. Esp if they want to achieve a very specific lux level.
Thanks for that, I have one more question... Could you explain what the significance of the scaling when importing .dwg files is? I'm skeptical whether the results for calculation are different if you use a different scale... is it merely a superficial tool just to enable the user to properly view the drawing in full view when needed? Thanks in advance, again.
It is very important to check the scale of your cad file before start creating the building or rooms, because u may easily noticed that the height of your room is not correct in proportion to the area of your room. If that happens, the calculation results will also be wrong. You will understand it more once u forgot to check ur scale. hehehe! don't blame me!
Dear Nelca, when i always find the calculation surface result on my furniture object, there's nothing can see the surface result. But if i find on wall or floor, the result can see. How should i do for this problem? Help me please :'(