In this video, I have charged r600a Refrigerant/ Gas in a refrigerator, and I have fixed the leak in this fridge as well, which will be very helpful for you to braze the pipe when you charge the r600a system.
******************************************************************************
Products You Might Be Interested in buying and sharing with your friends. Thanks!
Multimeters
NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
Thermal Camera
UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
Soldering Wires
10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
0.8mm/1.0mm 50g Lead-Free Solder➡️ s.click.aliexpress.com/e/_DDn...
0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexpress.com/e/_Deu...
Vacuum Pump
18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
Mani Fold Gauge
Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexpress.com/e/_DeB...
Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexpress.com/e/_DBi...
Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexpress.com/e/_Dkg...
Soldering stations
RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexpress.com/e/_DFz...
GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
******************************************************************************
Subscribe to The Channel 👉 bit.ly/3vNT7s3
Social Links
Facebook 👉 / forevertech3
Instagram 👉 / forever_tech1
Twitter 👉 / forevertech3
Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for 'Fair Use'
for purposes such as criticism, comment, news reporting, teaching, scholarship, and research,
Fair use is a permitted by copyright statute that might otherwise be infringing,
Non-profit, educational or personal use tips the balance in favor of fair use
#refrigerator #refrigerant #freon #gas #fix #leak #brazing #r600a

Опубликовано:

 

30 окт 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 71   
@joels7605
@joels7605 6 месяцев назад
Excellent tip about the oil. I'm not an HVAC guy and wouldn't have known to look for that. Thanks.
@redlion9199
@redlion9199 Месяц назад
I have been in the industry for 59 years, and would never use flammable refrigerant... It's insane!!!!
@kief4diamonds
@kief4diamonds Год назад
we leave the valves on all the units we fix. when we come back in 15 years. we can check it easy.
@theanimaster
@theanimaster 11 месяцев назад
I’ve seen this too - but they don’t put any valves on ours - they put nuts (like what you see here). A valve would be better - kind of like the quick release ones used in airbrushes - so that there’s no loss of refrigerant. Yet the people that did mine still screw the nut on and off as though nothing will get lost. SMDH.
@Tsssyoudontevenknow
@Tsssyoudontevenknow 3 месяца назад
Backyard technicians 😂
@Tsssyoudontevenknow
@Tsssyoudontevenknow 3 месяца назад
“We leave the valves on” 😂😂
@hvacexplained9341
@hvacexplained9341 2 месяца назад
The joke is on you. The Appliance will never last more than five years in normal operation. It’s by design from the engineers. 😑😑😑😑
@andreasmoll_0924
@andreasmoll_0924 Год назад
The valve remains on the compressor and is not soldered off. The pipes are laid neatly and pipes that are too long are cut off. The capillary tube is laid to the side and the tube is straightened
@cannon8170
@cannon8170 8 месяцев назад
Can you leave service valves on legally ? I’d be worried brazing ends, relying on a crimp to stop me blowing up haha. Only take a tiny leak to ignite. Thanks for video
@mahatalentndlovu2784
@mahatalentndlovu2784 2 месяца назад
I met a similar case lukewarm yours, leaking rusty pipe. I did the procedure like you did and the compressor failed. What could I have done wrong?
@wariswariss2303
@wariswariss2303 4 месяца назад
Terimakasih imponyah bos dalam dari Indon👍👍👍👍👍👍👍🙏🙏🙏🙏🙏
@anthonygabriel2252
@anthonygabriel2252 Год назад
Where can I purchase the instrument panel which was used to plug in the refrigerator?
@nelson_tutorial
@nelson_tutorial Год назад
Thanks a lot sir....
@kostas8969
@kostas8969 Год назад
Great Video. One question. Why did you remove the valve in the end? Isn't it ok to leave it there for a future service if needed?
@eEnzo0
@eEnzo0 Год назад
It would make his work redundant because anyone with a bit of knowledge, a spare fridge compressor used as a vacuum pump, a charging hose with ends ISO 1/4" thread and a can of R600 could do a short refill for a fraction of the price.
@hassanyusuf7280
@hassanyusuf7280 5 месяцев назад
Thank you
@berylmenon8790
@berylmenon8790 Год назад
Well explained, thx.
@forevertechenglish
@forevertechenglish Год назад
Glad it was helpful!
@tbone6354
@tbone6354 4 месяца назад
A very helpful tip is to 50ml of purified water to the compressor before regassing. This helps lubricate the oil
@judefernandez5533
@judefernandez5533 10 месяцев назад
Thanks
@tronixfix
@tronixfix 7 месяцев назад
Had a Samsung double door fridge a few days a go with leak inside the condenser. Unfortunatly not fixable.
@Shah2
@Shah2 4 месяца назад
Hi is it possible to just use a piercing valve instead of cutting and brazing?
@smb4052
@smb4052 Год назад
Good
@1marcelfilms
@1marcelfilms Год назад
What scale do you use? Any scale i have turns off automatically after a minute
@peterstock3429
@peterstock3429 Год назад
how about the dryer? removal and replacement of the dryer is important ! also nitrogen does not absorb moisture. Drawing a vacuum is important to remove the moisture as the liquid will evaporate, subsequent flushing with nitrogen is advicable.. Is this fridge even worth the effort?
@forevertechenglish
@forevertechenglish Год назад
I did the vaccum but couldn't film that. The dryer was fine, So No need of replacement, The goal of any nitrogen flushing system is to cleanse pipes and other parts that contain contaminants. And yes the effort was worth it. This refrigerator is still working fine. As it was fixed about 2 years ago.
@omi0777
@omi0777 Год назад
solid video!!!
@forevertechenglish
@forevertechenglish Год назад
Thanks
@BISON99
@BISON99 Год назад
Thanks very useful 😊
@riolakshan1841
@riolakshan1841 Год назад
Thanks alot sir
@forevertechenglish
@forevertechenglish Год назад
Most welcome
@chrisnene452
@chrisnene452 4 месяца назад
❤❤❤❤nice
@rafamirtech8920
@rafamirtech8920 Год назад
I'm always afraid, when I want to weld. traumatized . A few years ago until it exploded during welding. Can you provide a safe tutorial for welding with Refriger R600.
@forevertechenglish
@forevertechenglish Год назад
Oh dear that's sad to hear, You should always use two or even three punching tool and check the leakage with foam before welding on r600a. As I told these are the safety measure one should take, To check the leak with a soapy foam. I always check the leak before welding on r600a. To be safe from such incident.
@1marcelfilms
@1marcelfilms Год назад
nitrogen flow
@shashankv789
@shashankv789 2 месяца назад
How much is the charge of all doing this?
@AFTABAHMED41
@AFTABAHMED41 3 месяца назад
Hi, pl let me know how can oil charge in same compressor with marked section line or other side ? how much ml oil ?
@forevertechenglish
@forevertechenglish 3 месяца назад
Check the compressors specification from google. The oil value will be mentioned there.
@lwangajohn3257
@lwangajohn3257 Год назад
I didn't see you vacuum the system or change the drier since you expected water or moisture to have entered the system
@forevertechenglish
@forevertechenglish Год назад
I did it off the camera didn't show on the camera because I forgot to record that part in the video.
@ragupathiv5375
@ragupathiv5375 Год назад
How much CFM vacuum pump need for small appliances
@harshalrahman994
@harshalrahman994 Год назад
👍
@lloydpeniyasi4699
@lloydpeniyasi4699 Год назад
Thanks a lot but I beg to differ where you said there is a possibility of water in the system since there was a leak on the pipe in the drip tray. This may not be possible since the leak was on the high side the discharge side.
@wawerukamau1260
@wawerukamau1260 Год назад
The master is right. When you run a refrigerator with a leak on high side,it creates a vacuum in the system. After switching off the refrigerator ,water from the tray is drawn inside the system to fill that vacuum. That water and moisture must be evacuated using a vacuum pump before charging the system first.
@lloydpeniyasi4699
@lloydpeniyasi4699 Год назад
@@wawerukamau1260 have you ever performed a self vacuuming process before? If you understand that process you will understand this.
@wawerukamau1260
@wawerukamau1260 Год назад
@@lloydpeniyasi4699 I'm a qualified refrigeration and air-conditioning engineer ,I know what I'm talking about. Self vacuuming is done at the end of the condenser next to the filter drier.Some attach a capillary tubing for that process . Just put that capillary to a bottle of water while vacuuming ,switch off the compressor and you shall see the capillary sucking that water. Just as the same action when taking your favourite drink of Coca-cola using a straw.
@lloydpeniyasi4699
@lloydpeniyasi4699 Год назад
@@wawerukamau1260 it's ok boss we all learn everyday... thanks for that
@mtz5582
@mtz5582 Год назад
He ment moisture guvna. ..Please allow him
@kareemhameed4042
@kareemhameed4042 Год назад
Is passing Nitrogen same as Vacuuming ?
@wawerukamau1260
@wawerukamau1260 Год назад
Nitrogen is used as high pressure leakage detector as well as flushing the system. While vacuuming is used for evacuation of moisture and air in the system
@FrigoristeSteve
@FrigoristeSteve Год назад
Keep #frigoristesteve
@user-vd9bh1wj3b
@user-vd9bh1wj3b Год назад
Можно было оставить клапан шредера! И все в порядке!!
@forevertechenglish
@forevertechenglish Год назад
Я не оставил клапан Шредера, потому что хотел, чтобы это выглядело так, как будто никто не работал над холодильником.
@AliKing-hm9cd
@AliKing-hm9cd 11 месяцев назад
A Look
@RomelloArcan-ig4gk
@RomelloArcan-ig4gk 11 месяцев назад
Before charge#600freon ricreur flo that its ok
@nenadarsenovic4492
@nenadarsenovic4492 Год назад
Filter-dryer change!!?
@forevertechenglish
@forevertechenglish Год назад
The filter was fine, that's why I didn't Changed it
@LikeColorBlue
@LikeColorBlue 8 месяцев назад
if you use R600A, then you don't have to vacuum the cooling system, right?
@forevertechenglish
@forevertechenglish 8 месяцев назад
no we need to vacuum the system
@AFTABAHMED41
@AFTABAHMED41 7 месяцев назад
hi, is R600a refrigerant is damage the evaporator coil ?
@wasimedoo7994
@wasimedoo7994 Год назад
Compressor is giving me 3 to 460 psig and i am putting 0 to 3 psig of r600 Freon waiting for at least 20 to 30 minutes start the fridge condenser get warm start to give cool air work an freeze but stop ofter a week or two what is going on help me please
@sudeshkumar772
@sudeshkumar772 9 месяцев назад
Nitt global
@graceaustero4548
@graceaustero4548 Год назад
ííííííiíí it's k
@sasori25
@sasori25 6 месяцев назад
thats samsung have a weak ass pipe and selling price is high and poor customer service after sales
@frankmata1812
@frankmata1812 Год назад
To much work.
@wasimedoo7994
@wasimedoo7994 Год назад
I asked this question once I am doing step by step how you doing it and my work only last for three weeks the fridge work and stop freeze how come help me please
@forevertechenglish
@forevertechenglish Год назад
Please Elobrate did you replaced the compressor.
@toolateformenow2408
@toolateformenow2408 Месяц назад
Method one for charging should not be followed. NEVER start your compressor in a vacuum! Always weigh in the charge
Далее
How to add refrigerant to a refrigerator
10:02
Просмотров 21 тыс.
Remplacement Gaz R600a sans soudure
7:26
Просмотров 4,1 млн
How to Charge Refrigerant (Gas) in an AC unit?
3:00
Просмотров 143 тыс.
Fridge gas charging R600a ( Hindi & Urdu )
6:58
Просмотров 157 тыс.