Тёмный

How to Check CT turns ratio test | Ratio Test |CT Maintenance in Tamil 

Engineering in Tamil
Подписаться 6 тыс.
Просмотров 11 тыс.
50% 1

#Currenttransformer #turnsratiotest #EngineeringinTamil
In this video showd How to check CT turns ratio test,
For More Electrical videos in Practical Explanation-தமிழில்
Engineering in Tamil
/ @engineering-in-tamil
Electrical Accident in Back feeding supply
• Electric shock | Back ...
Live checking for Transformer turns ratio test
• Transformer turns rati...
How to arrest Transformer HV Bushing oil leak
• Transformer HV Bushing...
How to arrest Transformer LV Bushing oil leak
• Transformer Maintenanc...
What is meant by Transformer turns ratio Basic concept
• Basic concept of Trans...
What is meant by Current Transformer
• What is mean by Curren...
Current Transformer Polarity
• How to Connect Current...
How Check CT Resistance using multimeter
• How to check CT Resist...

Опубликовано:

 

15 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@__Mr_2001_
@__Mr_2001_ Год назад
Sir IR an WR an ratio , loading transfer vachi konjam test pannunga
@balasubramanian599
@balasubramanian599 Год назад
Super sir. Excellent explanation.
@muthuloveall1
@muthuloveall1 3 года назад
Thank you sir very useful 👍
@Engineering-in-tamil
@Engineering-in-tamil 3 года назад
Sir thank you Transformers video vum paruga sir Yellame practical ah yeduthathu Ennum electrical study materials venum na mail I'd or WhatsApp contact kuduga sir I ll send
@santhoshkumar8562
@santhoshkumar8562 Год назад
Need connection video sir
@tamilselvan8784
@tamilselvan8784 3 года назад
Thank you sir
@Engineering-in-tamil
@Engineering-in-tamil 3 года назад
Thank you sir Please keep support
@homeworkouttamilan6701
@homeworkouttamilan6701 3 года назад
Sir, what are the types of errors in ct and errors acceptance value evlo nu konjam sollunga
@Engineering-in-tamil
@Engineering-in-tamil 3 года назад
Bro Eppo Measuring ct na athulaiye kuduthu eruppaga yevala limit varikkum error erukkalam nu Athavathu 0.2 nu accuracy erutha entha ct measure pandra current la maximum 0.2 % error varalam Athukku mela error vantha entha ct accuracy illanu artham Athumattum illama Ct ah design padi manufacturing pannalum Antha ct ah practicalla field la use pannum pothu ratio Vila deviation varum entha deviation 0.25% kulla erukkanum Ethula phase displacement num oru factor Msg la fulla explain panna mudiyala just entha number Ku oru msg plan nu Naan voice msg la soldren 9787433094
@Engineering-in-tamil
@Engineering-in-tamil 3 года назад
IEC Standard- IEC61869-2
@arunprasanth8429
@arunprasanth8429 3 года назад
CT ratio calculation pathi konjam solunga bro
@Engineering-in-tamil
@Engineering-in-tamil 3 года назад
Thank you for your valuable comments Ct ratio calculation Simple thaan brother Onnum illa Basic ah 5:1 nu mind la vachikoga Athavathu primary la 5 amps pochina secondary la 1 amps varanum So reverse la winding tuns pannanum Primary single conductor secondary la 5 turns ratio 1000/1 nu sonna same concept la primary single turn secondary la 1000 turns 9787433094 WhatsApp erutha msg pannuga Ct oda winding tuns data anupuren easy purium
@michelvidallo7288
@michelvidallo7288 3 месяца назад
I can't understand you
Далее
Current Transformers (CT)
14:31
Просмотров 489 тыс.
Anyone can repair PCB now!!
13:29
Просмотров 732 тыс.
Dyn11 vector group explained in Tamil
9:32
Просмотров 33 тыс.
IR and PI Testing of Transformer in Tamil
10:05
Просмотров 24 тыс.