In this video, I install a new ceiling fan in a room with no existing ceiling fixture. I cut a new hole in the ceiling, install a new ceiling fan box, install a new wall switch, and run new wire; with access from the attic. This is a complete guide, from start to finish, with all of the details!I Lets go!
RACO Ceiling Fan Brace and Box Kit:
amzn.to/45ubReR
www.lowes.com/...
EATON Combination Switch:
www.lowes.com/...
Romex 14/3 Wire with Ground:
www.lowes.com/...
-----------------------------------
How-to and Reviews provides product review videos and how-to videos for a variety of unique and common products and applications. Save some money and do it yourself, and be informed about products.
If you find the content interesting, Subscribe so you don't miss future videos. A new video is posted at least once a week.
Subscribe to How-to and Reviews: / @howtoandreviewsofficial
-----------------------------------
#raco #ceilingfan #fanbox #DIY
-----------------------------------
How-to and Reviews

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 177   
@garbagemann9167
@garbagemann9167 Год назад
This has got to be one of the best video’s ever made on You Tube….It’s amazing you even added the wiring diagram…thanks for taking the time to make it! Great job
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Thanks for the feedback! Glad it helped!
@framos3
@framos3 3 года назад
you are not an electrician but your work is more neat and better than some electricians I know, good job man.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks, I appreciate it!
@marc6919
@marc6919 Год назад
You just want him to do an install for you. Lol. He does good work though I'm joking
@framos3
@framos3 Год назад
@@marc6919 lol wouldn't be a bad idea, I do my own side jobs so he would be of a great help :)
@kyleisek2258
@kyleisek2258 2 года назад
This is one of the best how to videos I have seen. Super clean and easy to follow! Thank you so much
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Thanks, I appreciate it! Glad it helped!
@gregervin4843
@gregervin4843 9 месяцев назад
What did you do with the wires that were originally being run to the outlet?
@kneel513
@kneel513 5 месяцев назад
I want to know this as well!
@fitnesslibrarian9013
@fitnesslibrarian9013 4 часа назад
You can splice the wires coming from the breaker (line) and your wire to the outlet (load) together. So you bypass the switch. Then use a third pigtail to power your switch and then your new wire to the fan and light.
@johnnicastro5931
@johnnicastro5931 5 месяцев назад
I am looking to do this at my place and I am wondering if after you take the outlet off of the switch will the outlet still work or will you have to mess with the wires at the outlet in order to still get power there?
@Nationalist101
@Nationalist101 3 года назад
Wow dude this is terrific. Easy to follow. Way to go. I appreciate your efforts
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks, I appreciate it!
@p00d78
@p00d78 10 месяцев назад
Some instruction on the switch wiring would be helpful Nicely done
@ernestleo6284
@ernestleo6284 Год назад
Great video with a lot of excellent advise. When I installed the ceiling fan in my home I installed wireless receivers with transmitters to turn the fan and lights off separately. The receiver controlling the light includes dimming which I found necessary because of the brightness of the new led light bulbs.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
I have seen those. They are pretty nice!
@kanf-qu8mo
@kanf-qu8mo 11 месяцев назад
Where did you get them from?
@edwardmckee7626
@edwardmckee7626 Год назад
Great video. Informative, easy to follow, no fluff. Thinking of adding a fan to our home office, will definitely come back to this as a reference.
@donwon2035
@donwon2035 Год назад
Best no nonsense install ever. Thanks!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Glad it helped! I appreciate it!
@josemendoza252
@josemendoza252 2 года назад
Great video! I have a similar situation but I am trying to figure out what to do about the wall outlet.
@charlessclafani9786
@charlessclafani9786 2 года назад
Recently installed new fan without existing wire. Light switch had no power line coming in, so I had a light in attic on 15 amp circuit that I decided to pull from. Used 14/2 Romeo 3 wire. Connected black to black (power), white to white(negative), and grounds together then back onto the attic light pull switch. Light turned back on after connections, and I ran my power line to light switch where I needed power. Ran a Romex 14/2 from fan to light outlet, then connected new power line to fan line - black to black, white to white, and ground to ground. Only wanted one switch so used wingtips at end of the connections, and made one line for each- black, white, ground which I connected to a new switch for use for powering on fan in that light switch. I turned back on breakers, and fan was on. However if I flick the switch it’s wired to it trips the breaker. Is it the wiring of the new switch, attic light circuit overloading? Any thoughts? Thank you!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
I will take a look, just so you have an idea of what may be wrong, but the answer is to hire an electrician. There is a wiring issue. When you turn on the fan switch, it overloads. You have a hot grounded. I tried, but couldn’t quite follow how you wired it. There were too many conflicting terms used, and I wasn’t sure what locations were being described. (Fan line, light switch, light outlet, attic light, attic light pull switch) I will outline the required wiring below for your own visualization and conception so you may understand where the problem lies, but my only advice/recommendation is for you to hire hire an electrician. You are unsure and guessing with electrical wiring is deadly. Hire an electrician. There are only 3 devices and 2 wire runs involved. Devices: 1. Existing power source (sounds like a pull chain light in the attic) 2. New fan switch 3. New fan Wire runs: 1. (first) 14/2 from existing power source to new fan switch. 2. (second) 14/2 from new fan switch to new fan Procedure: Connect (first) 14/2 to existing power source. Black (hot) to black, white (neutral) to white, and ground (bare copper) to ground. Run the (first) 14/2 wire to the new fan switch box. Connect white to the switch. Leave black and ground loose (not connected). Connect new (second) 14/2 into the new fan switch box. Connect white to the switch. Connect black wire to the loose black wire. Connect ground to the loose ground, then connect the spliced grounds to the switch. Run the (second) 14/2 from the new fan switch box into the fan box. From there, follow the wiring directions that came with the fan. But, it will be hot to hot, neutral to neutral, and ground to ground. I hope that helps for understanding purposes. Hire an electrician.
@joeheiser131
@joeheiser131 12 дней назад
Definitely appreciate your down to earth demeanor and straightforward process. Great job making this videao and sharing your knowledge!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 11 дней назад
Glad it was helpful!
@bthj81
@bthj81 3 месяца назад
Hello - thank you for the informative video. In your diagram it looks like the hot from your box or existing wiring is going to both black screws. Does this mean either/or? Or splice for both? Thanks.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 месяца назад
It’s going to both. This is a double switch. Both switches need the hot wired to them. A double switch should have a jumper between them by default. In that case you only need to connect to one of them, either one. Otherwise, if they are not factory jumperd, wire it to either one, then jumper it from that one to the other one.
@kowserparvez3355
@kowserparvez3355 3 года назад
You made it look so easy lol. Very good video and informative. Thank you sir.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Follow the video exactly and it will only take 12 minutes, just like in the video! Just kidding. It can definitely be done in a day. Having all of the required tools and supplies ready ready to go will save a lot of time and set you up for the fastest and smoothest install. I would estimate that that it took me about 4 hours (it took a little longer, but filming projects adds a lot more time). Glad you found it helpful!
@davionmillstoop6170
@davionmillstoop6170 2 года назад
You did and amazing job and I can tell as a Certified electrician
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Thanks, I appreciate it! Thanks for watching
@EdsterL
@EdsterL Год назад
I have the same situation in my room, but I have an outlet below that I plug in a lamp controlled by the light switch. How do I switch that so that I can use the light switch to control the new fan? Then use the outlet to plug anything else besides a lamp?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
That’s exactly what I did. Now the switch controls the ceiling fan, and the outlet always has power like a normal outlet.
@BOSS_805
@BOSS_805 Год назад
Simple , direct, accurate information, great video ✅ thanks 👍
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
I appreciate it! Thanks for watching!
@nelsonvazquez201
@nelsonvazquez201 2 года назад
I Picked the right video to watch! So simply laid out and explained . Thanks
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Awesome, glad to hear that! I appreciate it! Thanks!
@reddman1723
@reddman1723 11 месяцев назад
Hi. Commendable Job, detail/comments very plentiful, intuitive and informative. I have done this type of install for needed ceiling fans and lights adding these where there was none, both fans with lights and lights to dark rooms, hall closets etc. Being and growing up having show and tell and later buying how to books, this video was a welcome treat with generous comments, thanks a bunch, it's a keeper. Think my 6" crown Molding might be of use also to hide some of the cosmetic install damage. Be nice like in some homes newly built the planning took in thoughtfulness of pre-wiring in ceiling boxes for future fans etc. What a good idea even if one has to pay extra for each, as long as it is not ridiculous! Thanks again for your efforts
@Majki70
@Majki70 2 месяца назад
what can i do if i don't have access to attic? I have existing hole from pot light but no joists near by...i am also looking to install ceiling fan.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Месяц назад
There is also this style of ceiling box for when there isn’t attic access. It is installed through the hole in the ceiling. amzn.to/3WZNjJv
@doubledvideo
@doubledvideo Год назад
Thanks! We just bought a house with no light fixture or ceiling fan in the master bedroom... I'll be following your tips
@phamman300
@phamman300 8 месяцев назад
Did you install a ground wire from the attic? Or did you use the ground wire from the ceiling fan mount to ground your ceiling fan?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 8 месяцев назад
There’s a ground wire with the conductor wires.
@Bodybydubs
@Bodybydubs 4 месяца назад
I installed one but didnt go into the attic to seal the box. Now I have sulatiin falling I guess I have to go into the attic. 😵‍💫
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 4 месяца назад
That should take care of it!
@elizabethmartin3054
@elizabethmartin3054 Год назад
Amazing!! Perfect illustration!!! Thanks a bunch , for this ever so helpful video 😃👍🏼!!
@johnsadventures6783
@johnsadventures6783 4 месяца назад
I just go with a remote
@jorgeluiscorrea992
@jorgeluiscorrea992 2 года назад
I’m in the same situation as you. How would you deal with the outlet to always have power on? My outlet has the 2 whites and ground going to it as well as 1 red. The two blacks hots wires are twisted together. Would I just remove the red and attach the blacks to the outlet?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Hmmm… there is definitely a way to accomplish it. I would suspect that you are correct and the red went to the switch box and now does nothing, and the black just needs to be connected where the red currently is. I would definitely use a multimeter to verify and sort it out. If that is not working out, another thing to consider is leaving the outlet as is and splicing the existing outlet power wire (red?) In the switch (but is now disconnected and does nothing) splice it into constant power in the switch box. This will be like the switch is always on and the outlet will always have power.
@keithharrington8715
@keithharrington8715 2 года назад
As an electrical guy, your description leaves me with several questions. I would expect your recepticle to be split (a little tab is broken off to on the hot side to allow the recepticles to function as 2 seperate pieces). So the blacks should be constant hot, one in, one to the next double recepticle. The whites should be neutrals, one in, and one to the next recepticle. Grounds.....same....this recepticle and the next. The red, I expect to switch the top or bottom recepticle on or off depending on where connected. Your description sounds like someone replaced a recepticle and made both recepticle switch. Becareful and maybe check with someone local. There may be some thing unexpected there.
@adamthompson8432
@adamthompson8432 Год назад
This dude should have 500,000 subscribers!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Thanks, I appreciate it! Just glad to be helping people out. I’ll keep hammering away at it and we’ll see what the future holds.
@KingHarry1
@KingHarry1 Год назад
So you abandoned the old switched receptacle?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
That is correct. But I could have kept it and add another switch for the fan. I personally didn’t want that switch anymore. It switched power to a wall outlet for a lamp. No need for that functionality. I rewired the outlet so it is not switched and always has power.
@jackmarascio6665
@jackmarascio6665 2 месяца назад
usr a remodel electrical box for your switches
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 месяца назад
Absolutely! Thanks!
@michealshingler9697
@michealshingler9697 Год назад
If anyone is doing this you should drill from the bottom
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
I drilled from the bottom so: 1) insulation would not fall all over through the hole 2) so I would not drill through any electrical wire that may be laying up there
@augustuspurple
@augustuspurple Год назад
I want to do this in my basement, so i wont have the attic to walk around. Wondering how i would mount a brace and feed the cable through. Any thoughts?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
There is a ceiling box for this purpose; to install in a finished ceiling with no attic access from above. amzn.to/3Q7v01w For running the wire, you will need to cut access holes through the drywall at intervals to be able to route it, then patch the holes.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Also, you can use a ceiling fan that has a remote control to turn it on and off. Then you only need to run power to it. You don’t have to wire a switch in the wall.
@TheDBJExperience
@TheDBJExperience Год назад
Why didn’t you just use an old work box ?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
I agree. The store was sold out and I wanted to push forward. Old work is the way.
@arielalvayero5393
@arielalvayero5393 6 месяцев назад
I would like to know what type of cable to get that done ???
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 6 месяцев назад
Typically 14 gauge in a home.
@kennethamend8557
@kennethamend8557 2 года назад
When it came to the electrical, the information was no doubt thorough...this is something I have to physically do..in order for it to sink in.
@benjaminwilliams3568
@benjaminwilliams3568 Год назад
ONE THING YOU MISSED: Good video, however before installing the wall switch into the recepticle box. 1. Always test your switches to insure the fan and lights work. 2. Always wrap electrical tape around the switch to cover The Side Screws. This prevents future possible arching. Other than that very Good Video. See Example Here: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-mY45ZDdiPn4.html
@LAZRBEEM
@LAZRBEEM Год назад
Isn't tape around the screws only needed on a metal box?
@neilborkowicz
@neilborkowicz Год назад
Sorry, but your installation of the plastic box is NOT CORRECT, and is against the NEC. The plastic tabs are not supposed to be "knocked out". They are meant to be a clamp. On non-metallic single gang boxes 2 1/2 x 4, the cable does not need to be clamped if it is secured within 8 inches of the outside of the box (NEC 314.17(C) Exception). However, as you were not able to put a staple in behind the closed wall - those tabs should be utilized as a clamp as they were intended.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Thanks!
@davidcarroll4939
@davidcarroll4939 2 года назад
What happened to the outlet that the switch used to power? This is a great video on how to install but I still have the old outlet box on the other wall the switch controls.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
I wired the outlet so it always has power and no longer switched. In my specific case, the top outlet was switched and the bottom outlet always had power (the connecting tab between them was removed to make them independent). I just installed a new outlet leaving the connecting tab in place.
@davidcarroll4939
@davidcarroll4939 2 года назад
@@HowtoandReviewsOfficial So the switch no longer went to the outlet? Did it have power to turn on the fan or light?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
@@davidcarroll4939 That’s correct, the switch no longer went to the outlet. Constant power came into the switch box, connected to the switch, and the switch used to send power to the outlet. I ran a new set of wires to the ceiling fan, so now the power still comes into the switch box, connected to the new double switch, which sends power to the fan and fan light. The wires that used to bring switched power from the switch to the outlet are not connected and do nothing (they are still in the wall from the switch box to the outlet box, but are not connected to the switch or the out).
@aLaCartePizza
@aLaCartePizza Год назад
How would you wire a ceiling light with a fan? 🤔
@jcybok
@jcybok Год назад
Very good video man... Is that a universal ceiling fan box? How do you know how each ceiling fan mount will fit each box?...
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Yes, it is a Universal ceiling box. The mounting is an industry standard, and any ceiling fan will fit.
@jamiehutchinson2501
@jamiehutchinson2501 Год назад
So good, thank you!! I’m procrastinating because I’m mom, and I don’t want to go into the icky attic space. 🤢 how do I know the width of my drywall?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Lol. You can handle it! Drywall is typically 1/2” thick. You need to drill the hole regardless, so you can drill the 4” diameter hole and measure the thickness of it.
@ausrawsurf
@ausrawsurf 4 месяца назад
Excellent video, Intersting fan choice.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 4 месяца назад
Glad you enjoyed it!
@ME-yi1hx
@ME-yi1hx 2 года назад
GREAT video. Exactly what I needed to see.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Great! Glad it helped!
@jftube3333
@jftube3333 2 месяца назад
You are blessed to have such great skill & professionalism. Outstanding video.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 месяца назад
Glad it was helpful!
@tomspallone1868
@tomspallone1868 Год назад
The switch cover screws are not at the 12 and 6 position! Drives me MAD! Otherwise, great job! 😉
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
I definitely fixed that.
@BruceT-rg8bp
@BruceT-rg8bp Год назад
The Raco gang steel electrical box does not look like it is strong enough to support the ceiling fan, no? how many lbs can this box support? thanks
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
The ceiling box in the video supports 70 pounds.
@safisafari2223
@safisafari2223 2 года назад
My dream project is coming closer to reality , but I got a problem, no wall switch at all to use it for the fan☹! If I had one right now , I would turn off the rotating fan from the wall , because the chain form the fan switch broke on me a couple weeks ago!☻😱
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
You can fish a new wire down inside the wall. You can do it!
@andrewkampmann7170
@andrewkampmann7170 3 года назад
Why not just use and old work box instead of all that unnecessary extra work? Otherwise great information.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks. I appreciate it. The old work box is only supported by the drywall, and I believe is rated for 50 lbs. I think my fan required 70 lbs, but not sure. Either way, I definitely did not want to support my ceiling fan by the drywall. I would personally not install a ceiling fan at all without supporting it from the joists. Also, a ceiling fan results in a dynamic load (it is not just a static weight) which will cause failures in the future. There is another product available for installing a box without access from above. I would recommend this over an old work box. amzn.to/36lFToH I would use an old work box for a light fixture that doesn’t weigh much, but definitely not a ceiling fan.
@andrewkampmann7170
@andrewkampmann7170 3 года назад
@@HowtoandReviewsOfficial not for the fan, for your light switch. The plastic tabs turn out to secure to the drywall. Instead of having to pull the nails out of a new construction box breaking the loops off and running screws through it. It just seems like a lot of unnecessary effort.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
@@andrewkampmann7170 OK, got it! That makes more sense. Pretty much the same scenario. It was honestly pretty easy. I had to break out the old box regardless. Cutting the tabs and towing in a couple screws took less than a minute. The box was cheaper, and I just preferred to utilize the stud since it was there, as opposed to only clamping onto the drywall. But, great point! An old work switchbox is a great suggestion!
@JohnBGood-kq3ul
@JohnBGood-kq3ul Год назад
@@HowtoandReviewsOfficial Although you did a very neat and thorough job and explained things very well, by code you can't use the receptacle box that you used for the following reasons: You used a "New Work" box. 1)These boxes are designed to be mounted using the nails provided with the attached brackets. By screwing directly into the side of the box, you're doing a modification that's not approved. 2) Those knockouts are meant to be removed, as you did, because in new work the romex is secured within 12 inches of the box. Obviously, you can't secure the romex behind the sheetrock in old work. An "Old Work" box is designed just for that: Old work in an existing wall. It has tabs to secure it to the wall, or some actually have screws through the sides, but they are designed to be that way. Old work boxes also have different tabs for the wire to come through. They are not meant to come out, but provide stress relief to the wire. As I've said, the job you did was very well done, and I'm only bringing this to your attention not to criticize you but because seeing how you like doing things right, You'd want to be aware of this.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
@@JohnBGood-kq3ul Thanks. Constructive feedback is always welcome and I definitely do want to be aware of this. Thanks for the taking the time to share this. I appreciate it!
@tc32628
@tc32628 Год назад
Would you happen to know how to do the same install in a 2-story condo? 2d story is different tenant.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
If you are on the first story and don’t have access from above… This box is specifically made to install through a blind hole with no access from above. However, you will still like need to cut access holes to run the wire, then repair the holes afterwards. amzn.to/3yRpIhl
@andrewmerrell8148
@andrewmerrell8148 Год назад
I was worried for your safety since you had PT pants on with no PT belt.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Lol. I was active duty a little over 20 years ago when they had just switched from sweats to these black pants and gray jacket. They didn’t have the belt then. I think the jacket was a little reflective, but probably not enough. The belt must have came later.
@pantachapin986
@pantachapin986 Год назад
Great video man, thank you
@kevin_ramirez2529
@kevin_ramirez2529 Год назад
Great video, one question I wanna ask is if the outlet that was connected to the switch still works
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
Yes, now it has power all the time like a normal outlet.
@joby30
@joby30 3 года назад
Nice job! Great job on the video and installation.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks, I appreciate it!
@robertokuri7108
@robertokuri7108 3 года назад
the line out to something else in the wall switch did you just leave it or did you connect it somehow?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
I connected it. It was spliced directly to the line in power, before the switch, so it always has power. So, in the switch box: 3 neutral/white wires in the wire nut; (1) line in from the breaker, (2) line out to the fan, (3) line out to something else. 3 hot wires in a wire nut; (1) line in from the breaker, (2) line out to something else, (3) a short jumper to the switch. (Or, you could connect both the line in and the line out to the switch if the switch has previsions to accept 2 wires at the input) 4 ground wires crimped or in a wire nut; (1) line in from the breaker, (2) line out to the fan, (3) line out to something else, (4) short jumper to the switch. I hope that makes sense.
@robertokuri7108
@robertokuri7108 3 года назад
@@HowtoandReviewsOfficial oh I see, I just got a bit lost in that part in the video but it makes sense now, thanks for the reply man and great videos!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
@@robertokuri7108 I probably should have added one more diagram with the extra line out spliced in to clear it up. Thanks, I appreciate it!
@shavygrossett2556
@shavygrossett2556 Год назад
blessing🙌🙏 🙌
@ericjohnson4499
@ericjohnson4499 9 месяцев назад
That box went from $9 to $24. They owe you big time.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 9 месяцев назад
Oh, wow!
@wesalnawabi9396
@wesalnawabi9396 8 месяцев назад
Thanks very helpful I subscribed u r channel
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 8 месяцев назад
Glad it was helpful! I hope you find some of the other videos helpful or entertaining!
@yeldarb3058
@yeldarb3058 Год назад
Awesome video. Thx!
@obediahanderson788
@obediahanderson788 2 года назад
What if you don’t have a ground wire if it is a 1960 house?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
The only responsible and safe advice I can give is to consult a qualified electrician and install a grounded circuit box and run grounded wiring.
@waqargul3321
@waqargul3321 Год назад
WELL DONE mate keep it up
@theusconstitution1776
@theusconstitution1776 2 года назад
GOOD JOB! Ps Cut the coat hanger on a 45° angle at both ends make it as long as it can be straight! popping it in your drill and you can find spots floors and IF you don’t drill it in the right spot it’s small enough in most cases to rub your finger over it and nobody will ever see it if a handful in your toolbox or handy as hell * The black wire that formally went to your switched outlet could’ve been connected to your hot wire at the switch so that you didn’t have to open the box up and put a jumper on that outlet?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Nice! Thanks for sharing!
@TimS.
@TimS. 2 года назад
Thanks for the video! Nice old army boots you had for going into the attic ;)
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Happy it helped! I served active duty army in the early 2000s. I still have several pairs of boots and still use them regularly!
@imperialthreat
@imperialthreat 4 месяца назад
This is a really good video. Thank you!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 4 месяца назад
Glad it was helpful!
@VRtechman
@VRtechman 3 года назад
I thought 3 wire plus ground was yellow!?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
The color is associated with the wire gauge, not related to 2 wire vs 3 wire. 14 gauge is white 12 gauge is yellow 10 gauge is orange I used 14 gauge
@tgray8593
@tgray8593 Год назад
great job
@chezhiyanramalingam4338
@chezhiyanramalingam4338 3 месяца назад
Very nice and informative.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 месяца назад
Glad it was helpful!
@cheribeldin3588
@cheribeldin3588 Год назад
Excellent video and explanation. Loved the flex at the end!😊
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial Год назад
💪
@ThesexyMrX
@ThesexyMrX 2 года назад
After less than a minute in, you tell us u have attic access to the ceiling I knew what u were gonna do and no need to watch. You most likely helped others.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Sorry I couldn’t help you out with this one. Good luck!
@traviswalker007
@traviswalker007 2 года назад
how would you wire it if you wanted to use a 3 way switch top to control fan and bottom to switched outlet?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Not the right application for a 3 way switch. 3 way switches allow you to control a device from two different locations. There would be two 3 way switches connected to the device, with both switches in different locations, so you could control the device from two different sides of the room for example.
@claudiofornaroMusic
@claudiofornaroMusic 6 месяцев назад
Good job, very good videoing too. 👏👏👏
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 6 месяцев назад
Thank you very much!
@Max-mn8so
@Max-mn8so 2 года назад
thanks
@sutherlandrb32
@sutherlandrb32 2 года назад
Can you tell me what type of wire you used?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
No problem. Romex 14/3 with ground: www.lowes.com/pd/Southwire-Romex-SIMpull-25-ft-14-3-Non-Metallic-Wire-By-the-Roll/1000156173
@ramprasadb8687
@ramprasadb8687 3 года назад
This is best video, I have seen so far for my bedroom to install ceiling fan. Thanks for your video
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
I appreciate it, glad you found it helpful!
@jackterra4352
@jackterra4352 2 года назад
Very good instructional & informative video. I have a question. What size Romex cable did you run from switch to ceiling fan. I have a bedroom much like yours. Thanks for sharing. 👍
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Glad it was helpful! I used 14/3 (plus ground).
@jackterra4352
@jackterra4352 2 года назад
@@HowtoandReviewsOfficial Thanks for sharing..!
@kaneikaika
@kaneikaika 2 года назад
Your video is the most useful one that I've viewed. 👍👍👍
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
I appreciate the comment! Thanks for watching!
@Erweenie
@Erweenie 3 года назад
👍🏽
@fancythisgirl3
@fancythisgirl3 2 года назад
Is the outlet still functional or did you disable it?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
The outlet is still functional. It is now always hot.
@ssbsnb1200
@ssbsnb1200 3 года назад
Did you connect the spliced grounds using a wire nut?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
You can use a wire nut, that’s no problem. You can also twist them or crimp them because the connection doesn’t need to be insulated.
@adrenaline112
@adrenaline112 3 года назад
The green screw that comes with the ceiling brace and box kit, did you use it? Is it necessary?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Metal boxes should be connected to the ground circuit. To be safe, jumper from the wire nut with the other ground wires in the box to the green screw inside of the box.
@adrenaline112
@adrenaline112 3 года назад
@@HowtoandReviewsOfficial that makes sense, thanks.
@M3thodbombz
@M3thodbombz 2 года назад
Electrician approved 👍
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Thanks, I appreciate it!
@shaineelvaghani7702
@shaineelvaghani7702 2 года назад
Excellent video! Are you able to control the fan speed with this switch? If not, do we need a different switch type and how can we wire it?
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
The fan speed is not controlled from the switch. There is a chain on the fan that you have to pull to change the speed between low medium and high. know there are fans available that come with a remote control so you can change the speed from the remote instead of pulling the chains. A possible thought that I have is to use a dimmer switch, and always leave the chain on the high position. Then you can change the speed from low to high with the dimmer switch. I do not know if it is a valid solution, but may be something to look into.
@GarrettRAllen
@GarrettRAllen 2 года назад
@@HowtoandReviewsOfficial it is possible to install a dimmer switch to control the fan. Additionally, you can use the pull chain to set the fan to high to control the speed with the dimmer and the chain can be removed from the fan for a cleaner look.
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
@@GarrettRAllen Perfect, thanks!
@angelocruz780
@angelocruz780 3 года назад
Awesome video my man! Great tutorial 👌
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Glad you found it helpful!
@christopheradams1564
@christopheradams1564 3 года назад
Outstanding video. Thanks!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks, I appreciate it! Glad you found it helpful!
@miguelcolon8929
@miguelcolon8929 2 года назад
New to your channel… keep up the good work
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Thanks, I appreciate it. I have the next 5 videos planned and started. And a long list of additional future videos. I’ll keep them coming.
@miguelcolon8929
@miguelcolon8929 2 года назад
What Gauge wiring you are using
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
@@miguelcolon8929 14 gauge
@sgoulet3333
@sgoulet3333 3 года назад
Great video! Thank you
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 3 года назад
Thanks, I appreciate it. Glad you found it helpful!
@jimbola77
@jimbola77 2 года назад
nice job man!!!!!!!
@HowtoandReviewsOfficial
@HowtoandReviewsOfficial 2 года назад
Thanks, I appreciate it!
Далее
ХОККЕЙНАЯ КЛЮШКА ИЗ БУДУЩЕГО?
00:29
КВН 2024 Встреча выпускников
2:00:41
How To Install A Fan Box
4:11
Просмотров 663 тыс.
Best Hardware to Hang a Ceiling Fan
12:29
Просмотров 71 тыс.
How To Add An Outlet To A Finished Wall
10:51
Просмотров 10 млн
How to Install a Ceiling Fan - DREO Ceiling Fan
11:38
How NOT to Wire Light Switches in 2024 (New Rules)
15:21
RACO Retro-Brace® Ceiling Brace & Box Kit
5:20
Просмотров 227 тыс.
ХОККЕЙНАЯ КЛЮШКА ИЗ БУДУЩЕГО?
00:29