Good evening po sir ang ganda nman po ng bagong aircon n yan sir salamat po s tutorial kng paano mag install ng aircon unit god bless po at ingat po kayo
Yeah my thoughts also. I guess he didn't want others to really know the process. If the unit is new there's already freon inside the condenser unit enough for a 10ft of copper lines. So no need to add a freon but if your condenser is far and your line is stretched then that's the time you need to add a freon. As i remember i think 20g per meter of line. But always check for the manufacturer's manual because others may have different amount.
Things I would add or change in the installation: 1) Install the electrical connection with terminal connectors...This is safer and provide better connection. 2) Dapat separate yung insulation sa discharge copper tube and suction copper tube. The suction line is cold while discharge is hot. 3) Yung electrical wire dapat nakabalot ng conduit or better use royal cable 4) Use a bigger water dischage line that 1/2 hose will clog up in few years. 4) I will still use an aircon outlet and not cut the plug to connect the line directly to the breaker Hindi ipinakita yung pressure test and vacuum test if it is done at all.
Hi Sir this weekend kakabitan ako same unit and HP much better po ba na to use an outlet than cut the plug to connect the line directly to the breaker?
kung yung free na tubing may pre charged freon na madali nalng yang ikabit drecho na. pero may mga aircon na walng free na tubing or kung may free naka open ang tube . dapat kasi sealed walang hanging sa loob yan tubing pag pinasingaw mo na ang freon galing sa makina. bawal mag mix ang hangin sa freon
bakit pinagsama sa iisang foam ang suction at discharge line? magkaiba ang temperature nyan.. magkakaroon yan ng epekto sa performance mg AC.. biro mo magkadikit ang warm pipe at malamig na pipe..
boss, sabi ng installer ko dito, need tlaga 10ft haba ng copper tube kasi yon ang minimum requirement, masisira dw unit ko if below 10ft lng... tama ba siya?? 4ft lng sukat namin,, kaso need 10ft tlaga kaya nag adjsut nlng sa outdoor para maganda tingnan yong 10ft copper.
Yeah my thoughts also. I guess he didn't want others to really know the process. If the unit is new there's already freon inside the condenser unit enough for a 10ft of copper lines. So no need to add a freon but if your condenser is far and your line is stretched then that's the time you need to add a freon. As i remember i think 20g per meter of line. But always check for the manufacturer's manual because others may have different amount.
Hello po,.tanung lang po sana ako..maganda po TCL split AC na brand?khit local brand po..my balak.po kac ako kukuha ng AC. Slamat sa mka sagot. Godbless
sana all installer tulad nung aware sa pag dugtong ng copper wire pra walng leak c frean at no hassle. need po pla ng separate na circuit breaker pra sa AC sir? ksama na po ba yn sa mag iinstall kpg all in?
Two pipe in one rubber insulation? Indoor flaring sa labas... pag service dyan... sakit ulo..😢 di na pwede i pulldown... excess pipe gilid di sa likod ng outdoor..
Ilang amperahe po ung kinuhaan nyu ng power supply para sa ac na split type na yan? Kasi po ung sa amin, same brand split type din na 1.5, 2 units kinabit sa 2nd floor ng bahay. Ang total amperes sa 2nd floor para sa mga outlet ay 20A dun po nila kinuha sa mkaibang outlet sa 2nd floor ung power para sa AC, Tama po ba un, pwede pa po ba akong magsaksak ng iba pa sa outlet na un gaya ng tv or computer? Salamat po sa magiging tugon.
Hindi lang ako kumporme n naglagay ng breaker Jan sa tabi ng indoor may nabibili namang Aircon outlet para Jan at hindi dapat putulin ung cordon hindi naman maglolus yan, ang breaker dapat andon sa panelboard tsaka napakataas ng breaker pangit pa tingnan.
Boss question,, pina relocate ko ynug TCL ko same model sa video,, before nila baklasin yung motor sa labas,, may narinig ako nag leak na gas,, sabi nila hangin lng yun. after 24 hours nung naikabit, Nag try nako buksan,, hindi na lumalamig even after 1hour turbo 16 temperature,, normal lang ba to,, hindi po kaya freon yung inubos nilang hangin? salamat po sa sagot
hello po sir. nag order ako ng ganyan sa TCL lazada. kaso wala pa un freon . nalaman nalang nung diniliver. ngayon di na sumasagot si TCl. . ano gagawin namin sa aircon
Good day ma'am, huwag niyo I received order ma'am para ma request refund, pero Kung Fu mo na kayang ibalik dahil scam iyong naorder niyo pwede lng Naman pag lagyan Ng Freon iyan, pagawa mo na lng sa technician...ingat sa pag order
TAC-09CSA/KEI KEl Series nverter Split Wall-mounted •Variable Speed (Inverter) Cooling Only •5D DC Inverter •Titan Gold Technology 5-in-1 Health Filters •Fast-cooling •Quiet Operation EER - 10.9 TAC-09CSA/MEI T-Pro Series SMART AIR, SOFT CARE • Gentle Cool Wind • CleanXpress •Smart Airflow •IOT Inverter . Top Open Filter •30s Rapid Cooling •Smaller Closing Gap EER - 11.52 Halos pareho lang yung KEI at T-pro series konti lang diperensya niya sa EER sir..
@@angelmardelapena yung pong gentle breeze exclusive po sa T-pro series (/MEI) wherein yung buga ng cold air is pataas at pabagsak instead of yung direkta na normally maramdaman mo sa normal airconditioner, medyo harsh din kasi yung direkta yung tama ng lamig sa katawan na galing sa aircon, yung gentle breeze option ay namamaintain nya yung constant cooling without yung harshness ng buga ng aircon, mas maginhawa sa pakiramdam yung gentle breeze option po.
You need to review your building electrical plan if aircon is included in the minute planning of the electrical building plan. If not then we have a problem but only if there's an inspection but if not then i guess its ok. But you should review still because if the total load is exceeded especially you install large hp aircons then problems will really do occur in the future like overloading.
Ang copper tube kasama Siya sa installation which is iba ang presyo. Aside sa presyo Ng split type iba pa rin ang bayaran mo sa installation na aabot sa 6-8k depende sa laki Ng aircon
Sir kung derecho sa cb panel same aircon model anong wire gauge and CB ang dapat gamitin? Gauge 12-20amps po ba or Gauge 10-30amps? Under renovation po kami at gusto namin sana na kasama na may exlusive slot sa CB panel ung aircon para wala ng CB na katabi unv indoor unit.
@@joyfuentes6570 kabayan sana makatulong, kakatapos ko lang magpasurvey sa tcl accredited installers. Wire Gauge 10 with 20amp breakers if may budget pero pwede din daw na gauge 12 with 20 amp breakers. Mas makapal ang wiring mas matagal magiinit at wiring making it a safer option. Depende lang tlga daw sa budget.
Inverters does not need big diameter wires. Because inverters does not need to draw large of current when compressor starts to run. And its RLA only limits to about 3amps to 6amps depends how much hp your aircon are. Royal cord would be best but since on a budget thhn wires are also suitable. If you have a 1hp unit that has an RLA of 3 to 5 amps the thhn #14 is enough. Because it has a 25amps optimal ampacity at 90°C.. Happy to help
Sir magandang araw, ask ko lang po. Bumili kasi kami 1hp na split type ang problema wala kami naka abang na breaker, pwede ba na ang mag iinstall ng split type aircon sila na din mag gawa ng breaker para sa split type? Maraming salamat.