HOW TO MAKE THE ULTIMATE EXTENSION CORD! 

Stud Pack
Подписаться 617 тыс.
Просмотров 757 тыс.
50% 1

Klein-Kurve Heavy Duty Wire Strippers #K12055
From mcmaster.com
hospital grade receptacle #7462K31
receptacle with 2 type USB C chargers #6130T11
USB A charger #1420N1
build your own cover plates #8032K12 and K14
cord grip #69915K57
wagos #8904T12 and T14
green indicator light #7380K42
aluminum Bell boxes #7219K25
plastic 2-gang junction boxes #7954K21 and K24
inline GFCI #7228K17

Хобби

Опубликовано:

 

1 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 1,9 тыс.   
@LarryCoates1948
@LarryCoates1948 2 года назад
My one suggestion as an electrical engineer would be to place 20 amp outlet at the end where the line cord enters the first box and put the indicator lamp and hospital outlet at the far end. That would serve two purpose... it would keep the heavier current from passing through extra wiring and connections. Second having the indicator at the far end would indicate that power is actually getting to the farthest end of the unit!
@fourtwanky
@fourtwanky 2 года назад
except they used those wago bus bars to distribute the electrons, so each outlet was effectively the same distance from the main wire.
@amkelle2
@amkelle2 2 года назад
Can you explain the purpose of a 20A outlet when that GFCI plug is only rated for 15A?
@LarryCoates1948
@LarryCoates1948 2 года назад
@@amkelle2 - As stated in the video the 15A gfci can handle some overload although that is not ideal. You could usd a 20 Amp, inline gfci unit instead, but that might require you have access to a 20 Amp receptacle as the source power.
@amkelle2
@amkelle2 2 года назад
@@LarryCoates1948 To be fair, yes, I did not intently watch the whole video, I skipped through a lot of it to get the jist. But still, wouldn’t a 20A pull on a 15A outlet be unsafe? Or even pointless if the breaker is 15A
@LarryCoates1948
@LarryCoates1948 2 года назад
@@amkelle2 - it could be a problem but most likely not for a short term use. Long term yes ti would be a problem but would trip the breaker if it heated up for too long!
@Riless42
@Riless42 2 года назад
Most new breakers have 2 trip methods. One is magnetic which works primarily during a fault. The second is a bimetal coil, similar to an old fashion thermostat, this is the one that handles general overloads. Depending on the manufacturer, age, and use of the breaker it can take time for the coil to heat up and trip. Certain manufacturer like Zinsco and Federal Pacific wont trip and you get the smokey house effect. We hope there isn’t one in the house you’re at. It is perfectly normal to hit a higher amperage on a breaker for a short period of time before the coil snaps. I have seen a 20 amp breaker hit 25 amps and hold for 10 minutes. Ultimately heat is what trips the breaker in an overload and it takes time for the heat to build up and trip the breaker. If you had a thermometer on you at the time of the video, you most likely could have identified the breaker you were using by the amount of heat it would have been producing. How ever I don’t suggest replicating the scenario to try it. Overloading a circuit is never a good thing. The more heat a breaker takes on the easer it trips the next time. Great video! I got out of remodeling to became an electrician. I mis the remodel world. I watch your videos and you guys always have some new concept or product that I have never seen. There are a lot of new products that has come out in the last several years. I really liked the cabinet leveling kit. I switched to air bags just before I got out of the business, but this little gizmos you guys used knocked the socks off the airbags. I can’t wait to see the next video.
@TopCat2021
@TopCat2021 2 года назад
Excellent response to the question about the trip time, also the trip time is delayed for the inrush current of high inductive loads.
@moreause
@moreause 2 года назад
@@TopCat2021 I have seen 90 amp on a 15 amp breaker for a second or so to close a F***ing big coil was just a testing rig , normally this was powered by a dc charger and battery but was still surpise it was holding
@themadmallard
@themadmallard 2 года назад
I was about to say, arent breakers, supressors, etc all supposed to be sacrificial components? I'd definitely consider replacement in multiple scenarios...
@t0cableguy
@t0cableguy 2 года назад
Your answer is spot on. There are also trip curves available for almost every breaker except for those horrid Zinsco and Federal Pacific panels. Its pretty interesting to see how long a breaker will hold with a particular breaker. There are also different breaker trip curves, A-F that will determine the In-Rush available. In-Rush is what allows motors and capacitors to charge without tripping breakers constantly.
@tslim250
@tslim250 2 года назад
Zinsco and federal pacific are pretty much known in the inspection world as a no go and always labelled as a must replace. Interesting to see a sparky call it out in the wild.
@TwilightxKnight13
@TwilightxKnight13 2 года назад
Pro Tip: When you are twisting stranded wire, twist in the opposite direction. You may notice that when you cinch the ground screw it tends to splay the wire. The reverse twist is in the same direction as the cinching of the screw so it actually squeezes the wire in the same direction as the twist making a "better" connection.
@ottoroth9377
@ottoroth9377 Год назад
Ya know Bob....I would even go further and solider the twists..no freedom wire exposed....easier to insert. Stud man....gotta love that old wire...they made em well 40 to 50 years ago. Also, congrats no blood!
@codewonderland-gaming
@codewonderland-gaming Год назад
I would go even further here honestly. Over time, a soldered stranded wire end will warp due to heat and pressure when places in a screw terminal. Instead, crimp and solder the wire end in a ring terminal and put the screw through that
@codewonderland-gaming
@codewonderland-gaming Год назад
Without that extra step, the "contact resistance" will continue to increase over time and can cause a fire
@willschultz5452
@willschultz5452 Год назад
I'll give it a try!🙂
@randybobandy9828
@randybobandy9828 Год назад
@@codewonderland-gaming Just crimp it, no solder
@SuperTubeLurker
@SuperTubeLurker Год назад
Been doing industrial maintenance like ~6-7 years now and grew up in a home where we did everything DIY. Had literally zero knowledge that there was a stranded and solid side to strippers. Learn something new every single day, as long as you allow yourself to admit when you don't know.
@SlapperGlutesTwice
@SlapperGlutesTwice Год назад
Idk if I would advertise not being aware of super basic details like that. It says more about you as a worker in your trade than it does about the quality of this video 😂😂
@SuperTubeLurker
@SuperTubeLurker Год назад
@@SlapperGlutesTwice I'm not going to pretend. If you can't admit you don't know something you don't keep yourself open to learning. In any trade, if you keep your eyes and ears open, you learn something new every single day.
@nickiecass8808
@nickiecass8808 10 месяцев назад
Me too, I just learned it today! I love these videos Thanks !
@HA05GER
@HA05GER 8 месяцев назад
Depends on the strippers you use. I prefer the self adjusting jaw strippers or.just do it by feel. Most electricians I've ever come across strip by feel.
@BluesTravels487
@BluesTravels487 6 месяцев назад
I work in industrial electronics at a wire manufacturer, just to inform, the copper size is likely smaller than actual gauge size regardless of solid/strand. do you think they are just giving copper away?
@JeremySpidle
@JeremySpidle 2 года назад
Pro Tip: When tightening a cord into into a strain relief, press the cord inwards towards the connections on the device to de-strain them while you're tightening it down. This provides some slack inside the device and prevents strain-loading the connections during assembly. And... great video, thanks!
@lostreb
@lostreb 2 года назад
Great Comment!!! (While Stud Pack may have done that by instinct and because of experience, and didn't mention it. That's great information for those of us that don't have that experience to fall back on!!! Thank you.)
@jokinboken
@jokinboken 2 года назад
That sounds like something learned from experience! An "Ask me how I know" bit of knowledge. Thanks!
@parkershaw8529
@parkershaw8529 2 года назад
Also, cut the hot wire a little shorter than the other two wires, so, if the strain relief does fail, hot wire is the first to get disconnected.
@swordedaffair
@swordedaffair 7 месяцев назад
The ground wire should be longer than the other two. If stress on the cable causes wires to pull out or break, the hot or neutral will fail first - not the ground.
@DobermansRock
@DobermansRock 2 года назад
This was hands down one of the best instructional videos I have ever seen dealing with electricity. Knocked it right out of the park. It is also cool you are a father son team. Lots of guys wish they had that growing up.
@terrydouglas2777
@terrydouglas2777 Год назад
Plus you are still using your dad's electrical cords and they will be passed down to your son then his son in the future. The best part you are father and son, passing knowledge is what I truly love to do an teach my family how to fix and build things. I said family because I have an still teach my boys and girls how to do stuff. Teaching them is fun for me and they teach me new things as well. Making memories is what life is about isn't it. An you making videos of you both together is awesome. Better than the old time photo album our parents loved to bring out several times a year to look at.
@hstruzyt
@hstruzyt 2 года назад
I would mount the last grey outlet turned 180 degrees. You see at 23:30 how a right angle plug blocks the second outlet. Reverse the outlet, and you can use a right angle plug in the lower, or outer spot, and leave the other outlet available if needed. Great video!
@RambozoClown
@RambozoClown 2 года назад
Your typical circuit breaker has two trip modes, a magnetic and a thermal. The magnetic will trip instantly for high currents like a dead short, while the thermal portion can handle brief overloads to allow motors and other high inrush devices to start. The datasheet for the breaker will have the curves, but typically most will handle 200% for about 10 seconds, 150% for 100 seconds.
@jamesa8851
@jamesa8851 5 месяцев назад
Or its a challenger breaker lol.
@T_Jonesy
@T_Jonesy 2 года назад
This thing is incredible! Also love that when viewers suggest improvements, you guys listen instead of getting offended. Leads to an amazing solution like this. Great video as always. Love your channel.
@DiffEQ
@DiffEQ 2 года назад
Replete with expensive and completely unnecessary things. See my full comment for details. $15 for an indicator light? 12AWG stranded wire for a ground when even the current carrying conductors only need to be 14AWG solid? This channel was much better when it was just a son helping and documenting his dad doing remodeling work. It's now to contrived and monetized. I have nothing against people making money for their hard work... but I do have a problem with contrived content and "shocking" thumbnails used to manipulate. It ruined the channel for me. Do you think everything they linked to the overpriced McMaster site isn't getting them something at OUR expense? Please.
@sabarjp
@sabarjp 2 года назад
@@DiffEQ They didn't link anything to McMaster-Carr, they are just part numbers to look up yourself. That uncharitable comment of yours says everything about your heart's intentions. Try to be more kind.
@nicholasburr4825
@nicholasburr4825 2 года назад
@@DiffEQ just because your name is Richard, doesn’t mean you have to be a Dick.
@StudPack
@StudPack 2 года назад
@Richard M Interesting you mention the price Richard. We had thousands and thousands of people pick apart a simple extension cord and tell us how we should've done it. But when we spend the $300 to build it how they want, it's "too expensive". It's still a son helping and documenting and of course it's contrived, like everything we do! Thumbnails are used to get people interested, and none of our thumbnails lie or mislead. If you have a problem with attention grabbing Thumbnails, maybe RU-vid isn't for you bud. We put part numbers up for McMaster and we receive no kickback and we rarely post Amazon links even though we get hundreds of people telling us we need to do so. We don't like to respond to comments bred from negativity, but everything you said is blatantly wrong, and you should know that. - Jordan 😎
@TheDarthJesus
@TheDarthJesus 2 года назад
@@StudPack To be fair, quite a significant amount of your electrical "guides/suggestions" don't follow electrical code, and are unsafe/hacks that professionals are constantly having to fix. This went from a cool father/son channel to something cringe-worthy when your explanations/excuses for doing things illegally/wrong become video topics. Stick to what you're good at?
@tl1925
@tl1925 2 года назад
Of course you knew you were going to get comments on your ultimate extension cord. Before you paint with the flex drill 2 holes in the top of the board 16" on center. When you're at a job site with open bays, you can fasten it right up to the wall and the holes will be premade in your wood to mount on the stud's. Even without it's a fantastic device!
@elvagabundo4607
@elvagabundo4607 2 года назад
That is a fantastic addition T L. I bet we will see that in the next episode
@RichardBronosky
@RichardBronosky 2 года назад
25:55 My Dad was a Navy man in Vietnam. He learned this fact there and explained to me no less than 100 times. Which in hind sight was good because it took me about 20 to really grasp. When the impeller is able to move fluid linearly in flow, it constantly encounters new, axially stationary, fluid and then has to introduce torque. When the flow stops, the impeller puts torque onto the fluid, which remains linearly stationary, and the system becomes a flywheel. And we all know a flywheel take a lot of energy to get up to speed, but very little to keep at speed. I was probably 4 years old the first time I heard this and 8 before I could finish his story for him. Thanks for the memories, Stud Pack. ☮❤🌈🧘🏽🕉☸☯
@____________________________.x
@____________________________.x 4 месяца назад
Good explanation 👍
@dubmob151
@dubmob151 Месяц назад
A blower with squirrel cage fan also increases in speed when it's blocked on the airflow. The load test with the saws would have seen a very large increase in current draw of they were actually cutting wood rather than just free spinning; it's not very representative of their power draw just by turning them on.
@JeffcoInc
@JeffcoInc 21 час назад
My dad, also a Navy Man in Vietnam, went on to civic life as an electrical engineer, though his tradecraft was as Master Electrician. Mom was a public school teacher. A proud union family we were! When I was a kid I was "asked" to crawl around under houses (spiders, snakes, rats, even bats!) and in attics (either bitter cold or abominably hot...plus vermin and insects of every kind. Wasp bites were especially fun while rolling around in fiberglass in July heat.) But he made working hard fun. I got to swear like an actual sailor, trade barbs, take a ribbing and had lots of laughs. So cool to see Stud Pack guys as father/son team. That is rare! Like your pops, I paid a passive ear to his 'splainin as a kid. And though he's passed now, I can still recall hundreds of rhyming schemes, anecdotes and shorthand! I literally apply those mnemonic devices in physics, math, chemistry and weekend handyman projects now, As an adult who's also an engineer (of a different flavor), I'll always fall back on Dad's sage advice in tricky situations. @StudPack you guys do fantastic work! Love the channel!
@brandonleesanders
@brandonleesanders 2 года назад
Love how this guy took the “know-it-all” suggestions and added ALL of them to the project. GENIUS!
@ianworden5196
@ianworden5196 2 года назад
The super extension cord video was the first video of Stud Pack that I watched. Since then, I have watched every video of yours. I’m hooked. Great content, loads of fun and Paul’s personality has really come thru since your first video. Love the father son interaction and that Jordan is so respectful. I have a few tools of my fathers and grandfathers and really cherish them like you do with your fathers extension cord. Got to give Jordan a shot out. I assume this was his idea and the filming has been terrific. I’m not in the trades so Paul’s ability to clearly explain the work and tricks of the trade is excellent. He has a real gift. Having grown up in northern Florida, the heat and humidity is gruesome. So I know the conditions you are working in. The only video that was hard for me to watch was when you were installing pipe under the patio for a toilet. Paul looked whipped by the heat but he prevailed. I looked and felt the same way when working road construction in the summer in Fla. Thanks for such a fun and interesting channel. Keep it going.
@jperin001
@jperin001 2 года назад
Same here!
@bobjones9727
@bobjones9727 2 года назад
The first video I watched was the first extension cord build. I have watched every video since. All very well done and edited. I consider myself a jack of all trades and a master of none and have learned many things watching this channel.
@austincummins7712
@austincummins7712 2 года назад
Yep, same here. Glad I found your channel!
@carltonfaller3986
@carltonfaller3986 2 года назад
Me too!! I made something similar to the first ext cord project years ago and watched to see if maybe I could improve it. Then I got hooked on the whole Stud Pack attitude. And I was like, "that guy sounds like people I know." I live in Texas now but I've got family all over SE LA including BR. You guys are awesome and I really appreciate it that you keep a positive happy attitude. Keep up the good work. God bless.
@cdag24
@cdag24 2 года назад
Same!
@piercethesky281
@piercethesky281 2 года назад
Breaker didn't trip instantly because its being overloaded and not short-circuited. It'll take a few seconds to a minute to trip at only 8 amps of overload current and that's normal. Higher current overloads will trip it faster.
@JeremyPeters
@JeremyPeters 2 года назад
Just something to add to explain it a little better, there’s a strip of metal or a spring inside the breaker. 8A of overload will heat that metal up, making it softer. Over time that metal will deflect or bend, thereby causing the breaker to trip.
@northernlightsrenovations1710
@northernlightsrenovations1710 2 года назад
@@JeremyPeters Jeremy is correct. The breaker is thermally activated so if you allowed the 28 amps to continue for a period of time (rather than just a few seconds) it would indeed trip.
@Hachiro
@Hachiro 2 года назад
@@JeremyPeters Just like how turn signals used to work in cars, before they went electronic. The current from the incandescent turn signal bulbs would heat up the bi-metallic strip inside of the signal relay, making it deflect, cool down, and reconnect itself automatically for each flash. It's what causes the clicking sound you hear when you use your blinkers. Though, modern cars use LEDs, and electronic flashers. So the clicking sound you hear now-a-days is faked.
@trekie30122
@trekie30122 2 года назад
@@northernlightsrenovations1710 Most breakers trip and are able to be reset. Does the metal return to the original shape allowing it to be reset? Does a short just heat the metal to a deformation instantly then? last question, another RU-vid channel explained how an automatic analog rice cooker works using thermal deformation and a magnet like the old dial thermostats, does a breaker work the same way? Thanks for the response and explanation.
@notusedexer
@notusedexer 2 года назад
@@trekie30122 good questions. I hope someone answers.
@mikezimmermann89
@mikezimmermann89 2 года назад
EXCELLENT VIDEO! My dad was an electrician for 47 years and he taught me to be conservative and cautious in order to keep things safe. It was GREAT to see you carefully use many of the tricks that he taught me as well as many of the tips I’ve developed over the years thanks to his careful training. Cable stripping, strain relief, proper use of tools and adapters… you hit them all. Hats off as well to your commenters, who taught me all sorts of useful and interesting things that even 30+ years of well-informed DIY work had left me wondering about. I’ve subscribed to your channel, and I’m planning a “binge watch” to prep for some upcoming projects!
@ronaldross3978
@ronaldross3978 2 года назад
I am a Navy Veteran Electrician. Since I got out in 1980 I have been in electrical engineering field for my entire life. Before my Navy experience I attended two years in a VOTECH school for Industrial and residential wiring. I did get my journeyman electrician License. I do not use the Wegos on anything that draws current. Signal wires and Low Voltage lighting maybe. If you look inside you will see that they have a very small wire contact area. They will get hot under load. Use the screws on the outlet. they clamp with a good connection, current rated. Do not use the contactor discount outlets, they are made with cheap plastic that breaks too easy. The outlets should all be 20 amp rated and not mix and match. You went with the gimmick USB outlet. If you want USB charging, buy a USB charging strip. Your ground connection was a trick fix that should never be used. You should of used a solid conductor for this green screw connection then wire nut the other wires together in the back of the box. All box covers should be the gray type designed for these boxes. They are outdoor rated with spring covers over each outlet.
@ncooty
@ncooty 2 года назад
This video and the comments below reflect one of the things I like most about this channel. Paul is 85%+ for an amazing number of trades, and he presents in a way that is accessible to DIYers without condescending to pros. That means he attracts a very wide range of people, AND he's humble enough to showcase suggestions or corrections. I could hardly be more impressed with Paul. And obviously, thanks to Jordan for making the channel possible and for making the connections/ asking the questions for those of us who aren't as widely competent as Paul is. :) You two are a great team that has built a forum for a very helpful community. *Thank you.*
@DiffEQ
@DiffEQ 2 года назад
I used to be impressed. That's why I started watching years ago. Now, it just more contrived and scripted nonsense and it's lost that organic feel of a son helping his talented father. Just take a look at the thumbnail progression... more of the "shocking" and "???" thumbnails that are only used to manipulate and please the algorithms. They lost my subscription!
@steve_main
@steve_main 2 года назад
@@DiffEQ Then move on.. sorry I have seen a few of your comments on here on other peoples comments. If you don't enjoy the channel anymore than don't make those that like it have to listen to your negative narrative.. just unsubscribe and move on, Paul and his son don't owe you anything
@DiffEQ
@DiffEQ 2 года назад
@@steve_main What's your point? I already said I have moved on; As have many others. Doesn't mean I can't make the reasons known. Do you live in that world where all comments have to be praise and support? Do you? And you are wrong about people who are soliciting subscribers for profit when you say they don't owe those subscribers anything. This is not an altruist venture, sir. Get a grip. You chose to respond with negativity but others are forbidden to do so without your concurrence? SMH
@____________________________.x
@____________________________.x 4 месяца назад
People who show their mistakes on camera are good people. It’s how everyone learns faster
@ib9rt
@ib9rt 2 года назад
When you said NEMA 6-20 receptacle you meant to say NEMA 5-20 receptacle. The 5-20 is for 120 V 20 A, whereas the 6-20 is for 240 V 20 A. The plugs are different and are not interchangeable, so you can't accidentally plug a 120 V appliance into a 240 V outlet.
@jaydouglas1090
@jaydouglas1090 2 года назад
Thank you, at least someone else besides me saw this.
@x35gaming
@x35gaming 2 года назад
**magic smoke escapes**
@ghammer9773
@ghammer9773 2 года назад
I came to the comments for this. The plug he popped up on screen was a 6-15 too.
@skellious
@skellious 2 года назад
@@williamriven I was wondering that.
@25Nightops
@25Nightops 2 года назад
@@williamriven Nema 5-15 plug can go into a 5-20 receptacle. Allowing this extension cord to work in a 5-15 or 5-20 receptacle. The 5-20 receptacle is switched, but has no indicator. This probably would have been a good place for a switch with a pilot light (illuminated when on). Is the deal up to code, since it lets you plug a 20A device into a 15A circuit? Probably not, but you can make a hell of a useful extension setup based off this idea.
@Tritium21
@Tritium21 2 года назад
If you look in the datasheets for most circuit breakers, they have the over-current to hold time graph, which is a curve. at a low amount over the rated current it will take quite a while (up to an hour) for the breaker to trip - 15.5 amps in a 15 amp circuit for example. As the draw goes up, the hold time drops. A 60 amp draw would almost instantaneously trip a 15 amp breaker. Mechanically why this happens has been covered in many comments. Why this is a good thing... hasn't. Breakers can be designed to trip instantaneously for any peak over the rated current, but this provides no extra protection, and very well might cause problems with high draw devices like motors, that can draw great amounts of current at startup, but level off very quickly (inrush current). A few seconds above the rated current isn't going to heat the wires in the walls significantly, and since the breaker is only there to protect those wires (....and nothing else), there's no value in making it trip any faster.
@sivadfa
@sivadfa 2 года назад
Yeah, being able to hold a surge current for even a short amount of time is important. We don't want a circuit to break every time an Air Conditioner brings its outdoor unit online as an example.
@hsnester
@hsnester 2 года назад
electroBOOM on youtube had a video where he put 100 amps through a 20 amp breaker and nothing. he got the data sheet and it said something like it can take anywhere from 60 secs to 5 seconds to trip based on the amps running though it.
@sivadfa
@sivadfa 2 года назад
@@StellarSurge GCDIs are made to protect humans. Breakers and fuses are made to protect equipment and prevent structural fires. The main specification for a fuse or breaker is that the circuit breaks before the cable causes a fire, or hopefully break something.
@sivadfa
@sivadfa 2 года назад
In most countries gcdis and breakers tend to be one and the same. In USA this is not the case often only having ground fault protection to select few rooms.
@sivadfa
@sivadfa 2 года назад
@@StellarSurge two different names around the same thing. It depends on which country you live in which is standard
@Terkinstein
@Terkinstein Год назад
I used to drive a truck delivering stud packs to job sites. I really love y'all's channel. My late stepdad who I loved very much was a General contractor like you. He taught me so many cool things that I still think about today. When I watch you and hear your voice explaining stuff, maybe it's the kind tone you have, it just makes me feel like my stepdad is watching with me.
@aerotraveler
@aerotraveler 2 года назад
Ha ha…you are giving code enforcement and fire marshals across the world heartburn for sure with this project. Love it. I guessed right on the USB outlets, but you left out my second device. I was expecting a load sensing circuit to power up your shop vac whenever you started your saw. Maybe video three. Final comment is solid wire inside would be fine. Nothing should be moving inside these boxes. The stranded wire just made it harder to wire up like on that ground screw. Thanks for the entertainment.
@dubmob151
@dubmob151 2 года назад
I'd add a power monitor to the rig that can display the voltage, current, and power factor. They're available for a very low price and will let you see at a glance if you're approaching the limits. Basically a small panel display with a current sensor that you run the feed wire through. It'll add a Kill-A-Watt function to make it more ultimate. 😉
@raphaelnemetsky
@raphaelnemetsky 2 года назад
I see one improvement I would make. I would have the cord wrap BELOW the outlet boxes. That way I could use the boxes with unwrapping just a few feet of wire. The way it is now, you have the wire blocking the boxes. BTW, this is my first time watching your videos and I liked / subscribed.
@jamesalles139
@jamesalles139 2 года назад
for a variety of reasons, it is better to not have current carrying conductors coiled up. (heat build-up, magnetic coupling & noise)
@TwilightxKnight13
@TwilightxKnight13 2 года назад
@@jamesalles139 While certainly true, it is not really a factor in this application because the things being plugged in are generally motor-driven devices which already create a lot of line "noise," fluctuating magnetic fields, etc. If your application is so sensitive to these minor data points, you would engineer it to a much tighter standard. They already "over" engineered using the hospital-grade receptacle.
@jamesalles139
@jamesalles139 2 года назад
@@TwilightxKnight13 un-wrapping the cord is not 'over-engineering', it is simply a good habit for high-current loads.
@rfitzgerald2004
@rfitzgerald2004 2 года назад
The vacuum part surprised me, I hadn't really thought about it before but I assumed when it was clogged that it would be pulling harder to overcome the clog therefor drawing more current, turns out I was wrong. Every day I learn something new!
@davidk8893
@davidk8893 2 года назад
Yep, the vacuum draws less power due to the partial vacuum it creates behind the impeller. The motor has less drag since there's no more air to move and it starts spinning faster (hence the louder noise). One thing to keep in mind though is that since the vacuum is not moving any air through the filter it's also not moving any air through the motor. This means that the motor won't get cooled anymore and it may overheat.
@peterfus926
@peterfus926 Год назад
Same going to change my way how i look at that not to much stress then
@igotsomespace
@igotsomespace Год назад
Exactly my thinking and logic too prior to this video
@johnburgess2084
@johnburgess2084 Год назад
The blades in a fan are like airplane wings -- when you have a proper angle of attack, the wing produces lift to support the plane's weight, which also produces drag (load). As a plane slows, the angle of attack between the wing and the air increases until the air no longer flows smoothly over the wing; when that happens (a "stall"), both lift and drag are decreased. So, like the airplane wing, the blower blades stall, not moving air, and not loading the motor as much because, as others have said, little energy is being used to do work. That floored me for the longest time, too, until I became a pilot and thought of the lift / drag in that context.
@thomasjameson5761
@thomasjameson5761 Год назад
I also thought this!
@getyourbone
@getyourbone 2 года назад
The most amazing part of this is that you decided to film it to show those that haven’t been doing the same for years how to do it…one doesn’t realize that everyone else doesn’t already know this…👍👍👍🙏🏻🙏🏻🙏🏻
@EMTevjorgensen
@EMTevjorgensen 2 года назад
Jordan, I've got to say great camera work. You do a fantastic job filing your Dad as he's doing the work. I think you could pitch a show to the Home Channel on TV, you guys are way better than some of the other Home Improvement DIYers channels out there.
@tarbell111
@tarbell111 2 года назад
I second that. You have good attitude. Chipper. Ppl love to watch your videos. I would watch u on satellite for sure.
@Sembazuru
@Sembazuru 2 года назад
Probably comes from long experience of holding a flashlight. Similar activity: Point and keep steady on the work, predict what the next activity is so you can point to where the attention should be. I must say that I got plenty of that training as a wee young kid, myself.
@wcvp
@wcvp 2 года назад
The breaker didn't trip because it's not supposed to. Generally, home breakers will allow you to pull between 100% and 125% of the rated current indefinitely. The more over the rated current you are, the faster it will trip, so you can draw about 200% to 300% of the rated current for about 10 seconds. A dead short is far less than a second. I would link a breaker trip curve example, but youtube sometimes flags comments with links as spam. If you look one up, you'll see there are 2 lines, and the area between them is the "might trip, might not trip" zone (and is commonly shaded), so when you're sizing breakers for larger equipment, you need to make sure that your load will always stay to the left side of the left curve, including during startup, otherwise you'll hate yourself or other people will hate you. This might seem terrible, but it's actually a very good thing. When you turn on an inductive load (like an air compressor or saw), you get an insanely high current spike on startup, and the breaker tripping would make it completely useless. Yes, this is completely safe, copper has a lot of thermal mass so it takes a while to actually get hot and be a danger. Also I'm an electrical engineer, not an electrician :P
@dontworryaboutit3281
@dontworryaboutit3281 2 года назад
Wrong
@wcvp
@wcvp 2 года назад
@@dontworryaboutit3281 care to explain? I generally work on electronics so I haven’t done much with this since college
@dubmob151
@dubmob151 2 года назад
@@wcvp I wouldn't worry about it. Just a random troll 🙃
@chrisspellman5952
@chrisspellman5952 Год назад
When I was a kid, I remember my Dad and Grandpa trying to teach me stuff like this all the time. But I was to young to understand and appreciate it. Just ranomdly today RU-vid decided to share your videos with me and it's been great.
@Kristinapedia
@Kristinapedia Год назад
All that stuff is filed away in your brain somewhere. Watching these videos will bring it back.
@raptor__.
@raptor__. 7 месяцев назад
I don't know shit about electrical wiring but sitting here a 3:43 am writing this with a good ol' cup o' joe is always the mood
@partytempo
@partytempo 2 года назад
I love that y'all keep things as "live" as possible. Can't remove insulation on the first try? Tamper resistant receptacle being difficult? - Leave it in :)
@knutsenp1
@knutsenp1 2 года назад
Darn you, I just made your SUPER extension cord now you show me an ULTIMATE extension cord. I can't keep up with your great ideas. I'm retired and no longer take on the scale of projects you so easily tackle, so I guess I'll live with my SUPER extension cord. It was a fun project. You both produce great videos that are so great to watch. Keep up the great work. Stay safe.
@BlackDogBlues4961
@BlackDogBlues4961 2 года назад
In Ham Radio we often add meters to our panels to monitor voltage and amps on our rigs. This is especially helpful on mobile setups where you might be operating from a battery. Having a small LED display about the size if your green light would be handy to make sure you don't overload the circuit.
@Satsujiki
@Satsujiki Год назад
This is great!
@henderson1914
@henderson1914 Год назад
Any ideas where to source or find one of the led displays?
@josephlieberman3027
@josephlieberman3027 Год назад
"Jameco" Electronics company
@waxingmoonjfs
@waxingmoonjfs 7 месяцев назад
​@@henderson1914 I picked up a 5 pack of mini DC volt meters off Amazon for less than $10, I have seen the AC versions for about the same price.
@jimthesoundman8641
@jimthesoundman8641 6 месяцев назад
@@henderson1914 I get mine from Temu, AliExpress, Banggood or Ebay, whichever is cheapest. Make sure you verify their readings, sometimes the cheap ones will be inaccurate by 10% or so, but as long as you know, you can compensate. They have voltage ones, and ones which will display voltage and current both. Even ones which will display voltage, current and frequency if you are running off a generator.
@terryford4821
@terryford4821 Год назад
These Stud Pack how-to videos are quite possibly the BEST of their kind on You Tube.!!! They are at once instructional, understandable, complete and detailed without being pedantic or arcane, humorous and fun to watch, and the camera work is outstanding!!!!!! Count me as a Number One FAN!!!👍👍👌👌😁 😄
@johnroumeliotis5917
@johnroumeliotis5917 2 года назад
Hi Stud Pack , I am a electrician in Quebec Canada , I love your videos keep it up. The reason it didn't trip right away, is it wasn't a short circuit , try it again but wait longer so the breaker heats up and goes on overload , it should trip . But there are lots of old panels like commander and FPE panels that are notorious for not tripping on overload conditions. Electrical panels do need to be tested after 20-25 years .
@cheeseburgerbeefcake
@cheeseburgerbeefcake 2 года назад
As a bit of trivia for you - the current recommendation in the UK at the moment is every 10yrs, but we do have the madness of ring final circuits!
@mattholladay1331
@mattholladay1331 Год назад
i agree with this statement
@VictorLopez-vc6cf
@VictorLopez-vc6cf 2 месяца назад
Nice was also going to say this I am a Sparky in Texas
@kilopo3030
@kilopo3030 2 года назад
Hey man thank you. I binge watched this channel the past 2 weeks on my free time. I love this. My dad past away oh cancer 6 years ago. He was a handy man and showed me these tricks. But I’m learning so much more.
@PumpkinDog33
@PumpkinDog33 2 года назад
Sorry for your loss. Paul is a great father figure and his interaction with his son shows a really good dynamic where he's passing on wisdom without being arrogant or elitist. Especially when his son (or the internet) has ideas different from what years of experience has taught him.
@104silvae
@104silvae 2 года назад
Im sure your dad is proud of you. God bless you.
@____________________________.x
@____________________________.x 4 месяца назад
Yes, wago connectors, nice to see them being used. Actually my favourite takeaway was the mounting board with cable wrapping ears and a carrying handle, that’s a neat idea
@cjsmith1760
@cjsmith1760 2 года назад
As a retired electrician I complement you on the extension cord. However I must throw a word of caution about the paddle connections. For this application it probably wouldn't be a problem but having years experience in the oilfield electrial equipment and vibrations having a tight twist on the stranded wire under the paddle connectors will become a loose connection. The natural twist of the wire is good. The tight twist over time will relax.
@donfrost9457
@donfrost9457 2 года назад
I was thinking the same. We always tinned the conductor with a little solder to strengthen the mechanical connection.
@mleboeuf8764
@mleboeuf8764 2 года назад
It explain why we needed to re-screw connections of breaker box and terminals after a day or 2, to be sure the wire werent loose. Solid wires needed little tighting, but stranded wire where the always loose. So, we twisted too much ! Thanks !
@raygunsforronnie847
@raygunsforronnie847 2 года назад
@@donfrost9457 Solder will cold-flow under compression. I was taught to use copper ferrules.
@JasonfromMinnesota
@JasonfromMinnesota 2 года назад
I never twist strand wire much
@N719SM
@N719SM Год назад
Also a retired wireman. Whenever I would find stranded wires under a screw in this manner, the thought that would come to mind is that the guy who wired it was just plain lazy.
@pitsnipe5559
@pitsnipe5559 2 года назад
That has got to be the most awesome extension cord of all time. Reminds me of the ones we built when I was in trade school in sixties. We had the auto shop weld up some stands. We then attached two eight inch square boxes and wired in two duplex receptacles in each with thirty feet of 12/3 stranded cable. Great job site cords but know where near yours. Of course it was 1966.
@buddhabbuddhism8420
@buddhabbuddhism8420 9 месяцев назад
My dad passed away in March, of this year. He had the same type of extension cords you have, heavy duty black, and even one with the double outlet on the end (no GCFI tho). Seeing this, I'm now going to re-purpose his cords, for the ultimate extension cord, and memory. Made my day sirs. Ty. -George
@jmc5341
@jmc5341 2 года назад
You guys are awesome taking time out of your days to make videos for all of us. Much appreciated!
@MustardMade
@MustardMade 2 года назад
Man 27 minutes flys by with you guys! Excellent project
@jay9308
@jay9308 2 года назад
Technically, your 28 amp load would have never overheated or damaged the wiring. #12 wire is designed to carry 30 amps without heating beyond 90 degrees Celsius. Most wire insulation won't melt until beyond 105 degrees Celsius. Look up the NEC wire ampacity table. We are limited to using #12 romex at 60 degrees Celsius (20 amps) because it's best not to push the limits of the cable when risking fires. Many inexperienced DIYers tend to push the limits of electrical wiring. The #12 triplex wire you used inside the boxes is indeed rated for 25 amps, as it is only limited to 75 degrees Celsius.
@asbestosfiber
@asbestosfiber 2 года назад
You also have to realize that that wire may be in place for 50 years or more and the insulation may degrade. Also the abuse it may be subject too, so yeah you want a lot of room before you would hit the limits.
@hawk5602
@hawk5602 2 года назад
The #14 Awg that's probably feeding this outdoor receptacle rated for 15A but has a 20A at 75 degrees Celsius and 25A at 90 degrees Celsius carrying capacity on a 15A breaker disagrees. :P
@jay9308
@jay9308 2 года назад
@@hawk5602 I'm not encouraging anyone to draw 28 amps on a 15 amp circuit, just pointing out that the device they made up would survive a 28 amp load for a significant period of time.
@conniesisco6468
@conniesisco6468 Год назад
Absolutely FANTASTIC camera work! Super close shots of every thoroughly explained step. What a GREAT team.
@technicaltrucking8704
@technicaltrucking8704 2 года назад
i love seeing how dad has become the star of the show, I remember that first video i watched of the bed frame build and he was just a shy guy in the back.
@clintprice2123
@clintprice2123 2 года назад
Not only was this a great video it also showed items that many of us most likely never knew existed. The receptacle with the USB option not only saves counter space it eliminates the necessity for the little “brick” transformers which are just clutter once you’re done charging an item. The plug end gfi was another bonus.
@glennda5id
@glennda5id 2 года назад
This is a good point and as someone who does their own electrical it is not a big deal for me to install the USB charging receptacles in my house. The issue I have, is that the USB charging standards keep evolving. i.e., they used to be 5w, then 10w, now some phones are upwards of 100w charging capabilities. Also the underlying protocol used (ex one of the newest is PD3.0 with PPS) keeps changing for optimal fast charging. So in the end, I prefer to swap bricks than to keep swapping receptacles. That being said, I think its a great addition to this extension cord where you want less clutter.
@clintprice2123
@clintprice2123 2 года назад
@@glennda5id my son is a six year Tesla employee and he says fast charging harms a battery and slower is better. Using those cars as an example charging at home is far better than repeatedly using the supercharger stations. I have new/newer apple products and they came with larger wattage bricks but opt for the slower one as there is no need to rapid charge them. It’s personal choice.
@ritste1654
@ritste1654 2 года назад
My recommendation is to use a 10 Guage extension cord. If you are going to buy one, especially a 100', get the bigger wire. The bigger wire does not heat up as fast as a 12 or 14. Don't even think about a 16 ga cord for this. I could see you running a table saw and a vacuum together and both drawing about 9 amps, so a the 10 ga will handle the draw for a longer time. Also when I wired my dad's wood shop, I made sure to run a separate circuit for lighting. If the breaker trips, the last thing you want is a saw running in the dark. I would run the lights by themselves on a separate extension cord on a separate breaker if at all possible for safety. If you want to make 2 50 footers, buy 1 100' cord and cut it in half, it is cheaper. Of course if you go to an electrical supply, they may have it on a roll and you can buy it by the foot, you are going to cut the ends off anyways. I love this idea, the handle and mounting was a great idea, the hole to hang it on.
@lawrencesclerandi4564
@lawrencesclerandi4564 Год назад
I love the Father and Son quality time! Thanks for letting us share.
@jasonturner1045
@jasonturner1045 2 года назад
love this idea. I am always looking for outlets when working around the house. Especially outside. I will definitely be copying this in some form or another. nice work guys.
@chrisnash2154
@chrisnash2154 2 года назад
I built version one a couple of months ago and I love it. I will probably build a simpler version of this super ext cord, but I’m not a fan of that huge yellow GFI box. Love the built-in mount/cord wrap and love that it’s rubberized. The point is you guys pointed out that the bus bars we build are far better than the ones sold in the big box stores. They are also customized to our needs.
@stevebowser7248
@stevebowser7248 2 года назад
Great content as always! You always do a great job of the full explanation. Great point on the shop vac, its the principle of conservation of energy. The USB plug devices are the new best thing to add at strategic locations in a house. If one does ANY work on their home, this channel is must watch, hands down.
@vsetkoumiera7683
@vsetkoumiera7683 Год назад
I made up a cord and box exactly like yours minus the USB plugs ( it was before everyone needed a USB plug to survive the day) I made mine using 12G SO cord, 100 feet long and it’s laid out in sun light, rain, snow, ice and anything Mother Nature can throw at it and it’s still working great, with hardly no voltage drop too
@notSusNugget
@notSusNugget Год назад
Love the synergy of the team. And i among others appreciate the knowledge being shared. It is very interesting as someone with 0 background experience to see you being able to customize it to your needs and properly implementing the safety breaks.
@videolabguy
@videolabguy 2 года назад
Awesome as ever! Shouldn't the highest current receptacle be the first one on the daisy chain? The lightest load (the USB chargers) at the the far end. That way, the high current load doesn't have to go through a half dozen interconnects. It makes sense to put the high load socket and the pilot light in the first box so the high current is first on the line and the lamp let's us know power is coming in at the source. Though improbable, one of the connections in the middle of the boxes might fail. You still know the cord is hot. Keep up the great work, boys. If your video pops up in my recommendations, I get a piping hot cup of Joe, sit back and enjoy the show!
@JSH1
@JSH1 2 года назад
It makes no difference the order of receptacles, just because one device is able to pull 20 amps, doesn’t mean the rest of the devices are getting “high current”. Kitchens are required by code to be fed with 12 gage wire and 20amp breaker. It makes no difference if you are running several high amp appliances on a certain plug and then have your phone plugged into a different outlet…your phone isn’t going to fry with high current just because you other appliances are pulling 20amps. You also probably don’t even know the order the receptacles were wired anyway because it’s not an issue.
@xXCursedWorgenXx
@xXCursedWorgenXx 2 года назад
@@JSH1 it's like when you use the receptacle installed on your oven to power other stuff.
@trekie30122
@trekie30122 2 года назад
@@JSH1 We watched him wire it so we know its one box to the next meaning the switch and 20 amp outlet are at the end of the chain. I think you missed the point of his question because it had nothing todo with the wire being able to handle the current, your explanation may be valid but didn't answer the question. wires in the wall or box are unlikely to fail, especially when there is never stress on the wire, that's why code has them clamped to the box and within a certain distance of the box to a stud. His point was a physical connection is always going to be weaker than a solid wire. logic would say that the highest power should have the fewest possible disruptions to the current which leads to his question. Science or testing may show that the logic is incorrect, or does not have a significant difference to how it is wired.
@JSH1
@JSH1 2 года назад
@@trekie30122 I’m simply saying that it doesn’t matter on the order of 20 amp vs 15 amp plugs…note that 15amp duplex’s are rated for 20amps. There is no stress from box to box the way it’s installed. If he was connecting box to box with SO cord and not secured to a backer board then that would be a valid statement that the wires would be more stressed than a typical install.
@remodz6385
@remodz6385 2 года назад
@@JSH1 absolutely it does matter. If you have the 20amp receptical at the end and plug a device in that is pulling 20amps, then that middle 15amp receptacle has been overloaded as the power has to pass through that one first.
@jeffreyhudson3690
@jeffreyhudson3690 Год назад
Love your videos! ALWAYS learn something from you guys! Thanks for all the hard work you put into making them.
@RichardBronosky
@RichardBronosky 2 года назад
26:16 Okay, last Dad comment (on this video :-) for you. When you wrap a cord in a loop as you are doing, you are introducing a twist. The conductors inside are twisted, and the strands of each conductor are also twisted. This compounding effect is what causes old cords to the get the "umbilical cord" damage. However, with the quality of cord you are using here, that is never going to become apparent (as evidenced by the age of this 3 generation cord). Even so there is still a good reason to use my Dad's Navy wrap method. The Navy wrap is to make a figure eight on the side opposite the handle. This has 1 immediate benefit of not obstructing the outlets. But also each pair of wraps is a 1/2 twist minus a 1/2 reverse twist. Here's an exercise: If you extend the cord only 1 foot because that is all you need at first but then later decide to take out the rest of the cord to move your tool farther away, you can do so without unplugging anything. The cord will be straight. No twists. Try that exercise both ways. It's mind blowing.
@djamelhamdia134
@djamelhamdia134 2 года назад
The first extension cord video is the first video I've ever watched of Stud Pack, then I was really hooked to these guys, subscribed immediately and never disappointed!
@eshicks9514
@eshicks9514 2 года назад
Small suggestion that I’ve seen on British plugs. They leave a bit of slack on the neutral and a little more on the ground so that, if something pulls the cord out of the plug, they detatch in a specific order - live 1st & ground last.
@mrmotofy
@mrmotofy 2 года назад
Not a bad theory
@GeneralBBBlackSheep
@GeneralBBBlackSheep Год назад
Very smart 🤓
@aarontooth
@aarontooth 8 месяцев назад
Good idea.. almost makes up for centuries of the British empire terrorizing most of the globe with rape and pillage. We wouldn't want the king's fancy little fingers getting the zap zap.
@LaurenKingAllen
@LaurenKingAllen 6 месяцев назад
This is a fantastic project. Real men improve shit and prove they are secure in their self worth by listening to feedback instead of getting defensive. Love it!
@willschultz5452
@willschultz5452 2 года назад
Jeff love the power station with the plywood backing! If made similar ones but I love this one the best!! Love your attention to detail on everything you do!! Thanks👍
@Sway787
@Sway787 Год назад
Loved this build! I think I'll make a smaller one but I'll use the outdoor boxes with the lids attached.
@ronlovell5374
@ronlovell5374 2 года назад
Love this! I was gonna buy an expensive power strip bar with led lights and USB built-in for my shop, but now I'm inspired to build a custom one and add an auxiliary twist-lock whip and breaker for my generator. Thanks Stud Pack!
@desireeespinosa3954
@desireeespinosa3954 2 года назад
I just added some heavy duty in wall outlets with USB and C ports in my shop. Made a huge difference. So much better 😂
@rusosure7
@rusosure7 2 года назад
Seeing you leave a bit of green insulation on to prevent the stranded from splaying was well worth the price of admission.
@johntamulonis4626
@johntamulonis4626 2 года назад
Great device! Thanks for sharing.
@davewallace.8303
@davewallace.8303 10 месяцев назад
Awesome video guys! I’ve done some wiring as well, totally within my wheelhouse to tackle something like this. Also, I like how you didn’t “dismiss” the safety “Karens” out there, but actually incorporated their suggestions! Very cool!
@ayuse01
@ayuse01 2 года назад
A breaker is a Thermo-Magnetic over current protection device. The '' Thermo'' portion of the breaker consist of a bi-metallic* strip of metal that is heated by a resistor in series with the load *( two dissimilar metals fused together, each having their own thermal expansion coefficient, thus creating a curve in the metal strip when subjected to a heat source. ). this flexion of the bi metallic strip of metal is used to trigger the breaker opening mechanism. the bigger the overload, the faster it heats up, the quicker it trigger. On the other hand, in the event of a pure short circuit, the Amps drawn can easily climb to 1000 amps on a 15 amps line in a fraction of a second, too fast for the bi-metallic system to react in order to prevent the wires from glowing red. This is where the ''Magnetic'' portion of the breaker comes into play, inside the breaker the load/amps have to pass thru a coil of wire that act as an electro-magnet, but just when huge amount of current pass thru it, so when a pure short is present with thousands of amps, the electro-magnet pulls the triggering mechanism of the breaker and opens the circuit. Simple design, very effective.
@thankswezilow6794
@thankswezilow6794 2 года назад
I would say the ohms resistance on this build extension cord is one of the best in the industry compared against other multiple outlets connectors. which is why others burn up. I believe the breaker is set to an average resistance for the regular consumer and bc this was diy built the breaker did not trip. but thats not a real world test bc nothing like that is ever that close each tool is usally in its own area so may be adding some 25 ft to 50 ft extension cords would really load test the breaker and and and the load when cutting is higher so may be performing an actual cut for testing will pull more than 28 amps for sure
@thankswezilow6794
@thankswezilow6794 2 года назад
great explanation by the way!
@randacnam7321
@randacnam7321 2 года назад
Not all breakers are thermomagnetic. The breakers in a lot of power strips and inverters are usually thermal only.
@terrancevangemert7508
@terrancevangemert7508 2 года назад
@@randacnam7321 That is very true and hospitals and other more health related places have thermal protection and magnetic action as does homes or residential. Canadian standards now do not accept any breakers that do not have at minimum Thermal and magnetic trips.
@ayuse01
@ayuse01 2 года назад
There is also GFCI, AFCI, and so on, but for the sake of simplicity i talked about the most common house panel model.
@PhaseFroZen
@PhaseFroZen Год назад
That is a pretty awesome Ultimate Extension cord! digging that 4 port USB A and the receptacle with the USB C. Great build!
@seanoneil1681
@seanoneil1681 Год назад
I thoroughly enjoyed the re-purposing of the cord in the first video. Ya'll went Tim Allen on this one 😆 ! 5 stars
@billsinclair7280
@billsinclair7280 2 года назад
Although I don't remember exactly how long ago it was but somewhere in the neighborhood of 25 years ago I was faced with an extension cord with a bad female end. I didn't have a replacement handy but I did have a metal two gang box and some receptacles, so I put them on the end of the cord and still have that cord today. It makes a pretty versatile extension cord where I can actually plug in four different things. It's really handy when you're working on a job and you're using a drill and a saw and a light and God knows what else and you can plug them all into the one cord so you don't have to unplug something to plug something else in every time you want to switch tools. Anyway, great video that is an awesome ultimate extension cord.
@georgewilliams8228
@georgewilliams8228 2 года назад
Love the build. One thing I would be concerned about is the life span of those cover plates. Corners have a good chance of snagging. A frame around the boxes so they have something to sit on should be an easy fix.
@jefferyjanssen4723
@jefferyjanssen4723 2 года назад
I came to the comments specifically to find this. It was the first thing I thought of as well.
@69nunyabidness
@69nunyabidness 2 года назад
Being a tin bender, AKA metal fabricator, I immediately started to design the enclosure in my head. It's a character flaw!
@raulmoreno8259
@raulmoreno8259 2 года назад
Really enjoy watching you’re guy’s video. You guys have great attitudes! Thanks for the ideas!!!
@FoxBonly
@FoxBonly 2 года назад
Watching your custom extension videos was sooooooo instantly gratifying......
@Spiderslay3r
@Spiderslay3r 2 года назад
Big improvement from the last video, couple things for people looking to replicate this: 1. There's no right way to hook stranded around a screw, just use a solid pigtail. 2. Those usb receptacles are convenient but the power supplies are always cheap crap that leak power like a sieve at best and are fire hazards at worst. 3. In case anyone was confused by Stud's comment in the beginning, this is still not OSHA kosher.
@ranger178
@ranger178 2 года назад
no cord is approved unless it is tested and tagged with ul approved sticker so you can make it any way you want we had crazy safety guys cut peoples cords that he didn't approve and inspect beforehand on industrial job sites
@jperin001
@jperin001 2 года назад
It's not kOSHAr?
@Lewdacris916
@Lewdacris916 2 года назад
@@jperin001 LOL
@lelandclayton5462
@lelandclayton5462 2 года назад
I thought about making one like the smaller one you guys made but with an outlet with USB-A. However seeing the plywood backer for the cord wrap feature and hole to hang it got me thinking and possible add a few other features like a cradle to hold a phone while it charges. Maybe a little shelf with a hinge and kickstand.
@blogauthor3375
@blogauthor3375 2 года назад
thanks for including part numbers. Makes building it easier.
@simpsonhomerenovations
@simpsonhomerenovations 2 года назад
Well I know what I'm doing today. Building a ultimate job site extension cord! Thanks for all the tips. I love your videos! You all have a blessed day. 👍
@MAGNUMCC
@MAGNUMCC 2 года назад
Just FYI there are tons of products out there which will charge devices via USB-C, but the part where you're referring to being able to charge an iPhone 12 from 0% to 100% in ~1hr is because of Power Delivery. This IS proprietary to USB-C, but not all USB-C chargers feature Power Delivery. If you want this kind of high speed charging you need to make sure that your device is capable of charging with Power Deliver, and you charger is specifically designed to do Power Delivery, (often called USB-C PD accompanied by a wattage rating like 18W, 20W, 30W, etc...). If you don't see any mention of Power Delivery on a charger you're thinking about buying, then it does not have it. They are more expensive, but well worth it.
@mrmotofy
@mrmotofy 2 года назад
Also QC 3.0 is usually around 15-18w and higher voltage than typical 5v USB. There's getting to be way to many variations. I got a nice little USB volt/amp tester that tells ya exactly what it's at. I also recently got a multi port 60w PD and QC3.0 supply that tells you volts and amps of each port when a device is activated. You can see the power curve as the device gets charged. Kinda cool.
@PCHUGGER
@PCHUGGER 2 года назад
Awesome job! Those screws on the sides of electrical outlets are very interesting. I used to think they were a combination of Slotted and Phillips, but I was wrong. Slotted screwdrivers don’t work well as they can slide around too easily. Phillips head screwdrivers in those screws work better, but these screws are not designed for Phillips drive. You can see in the middle of the screw a square hole (not a pointed Phillips hole). This is called a Robertson drive (square drive). It fits perfectly (no sliding) and allows you to easily drive them even in odd positions. You can buy Robertson drivers at most tool outlets, but there is an even better solution that I recently discovered. Milwaukee makes an ECX driver that is specifically for electrical work (insulated down to the tip). The ECX driver is a combination of Slotted and Robertson drives. It’s been great for my amateur electrical work. It comes in two sizes - #1 is for normal stuff. (Jordan - Father’s Day is coming).
@ranger178
@ranger178 2 года назад
klein also makes screwdrivers labeled c1 and c2 for combination screws it is on my 15 in 1 ratcheting screwdriver from them it is starting to show up in newer assorted screwdriver tips packs also
@mrmotofy
@mrmotofy 2 года назад
It's nice to see more and more devices moving away from the stripping Phillips
@Cosm1cCream
@Cosm1cCream 2 года назад
For some reason this video speaks to me. My Father is like a God from what everyone says when it comes to home improvement and I've been around it my whole life so when you mentioned your son records you it touched me man. I love it
@DreadWingKnight
@DreadWingKnight 2 года назад
"What we do not use up, we use again" seems like the theme of these two extension cord projects.
@mw3261
@mw3261 2 года назад
You can also use a seam ripper (used for removing stitches in clothes) to cut the wire shield off, it works for automotive wire harnesses good. Love the videos!!
@jbman413
@jbman413 Год назад
I worked with a retired AVCM (Don Noise) for a short time; who told me he also used a seam ripper to cut “spot tie” on on wiring harnesses. He was absolutely correct works much better than dykes, knife or scissors. Thanks for the tip.
@randydewees7338
@randydewees7338 8 месяцев назад
Suggestion - get your own ripper, don't use your wife's
@AllanSmith-vy2nn
@AllanSmith-vy2nn 8 месяцев назад
Been there Done That Now Divorced with holes in my pants@@randydewees7338
@pjh1776
@pjh1776 2 года назад
Watching your videos reminds me of working with my dad, God rest his soul. Bud, cherish these days of working with the old man. You will never forget the life lessons weaved throughout his common sense work ethics and skills. Love your Stud Pack videos, thanks. Oh, and I have some old heavy duty cords from my Dad, I know what I'm doing with em this weekend.
@bobbyg4100
@bobbyg4100 4 месяца назад
Excellent Video, you have great Communication skills and also great Video Camera operator . I live in Oregon and it’s constantly raining. Your GFCI SYSTEM is Awesome.
@marco-xq8nj
@marco-xq8nj 3 месяца назад
Brilliant !! Such great skill. I'm a big fan of your first extension cord. Thank you.
@yutubl
@yutubl 2 года назад
Really usefull idea! For better safety always make the protective wire longer than hot and cold wire, so that it's the last wire that can be drawn loose in the case of a loosen clamping plate.
@theteenageengineer
@theteenageengineer 2 года назад
The next thing I’d like to see is an extension cord that allows for 240 volt input and has a built in breaker panel on the board, that way you can run a really high power device like a table saw or a planer. You also get a nice advantage if you use 240 for the cord, because by adding one more wire and using a 4 conductor cord you can either run a 240 volt tool or you can split the phases and have twice as much power for 120 volts. You could also add one of those little voltage and current readout displays that way you know how much power you are drawing. And as for why the breaker didn’t trip at almost 30 amps, if it’s a 20 amp breaker it is expected to hold at 100% of its capacity (20A) and thermal trip at 125% of its rated capacity, and magnetic trip (short circuit) at 200% it’s rated capacity, thermal trips usually take a while, because when you have a current surge on say a saw it can often pull over 20 amps, and you don’t want the breaker to trip every time you start your saw. ElectricianU has a good video on that subject
@jimparker5185
@jimparker5185 2 года назад
I think your point is twice the current when you split the 240v into 2 120v circuits. However, technically Power = Watts (unit of measure in the US) = Volts * Current (for DC anyways, AC is more complicated than what I'd do in youtube comments). When you halve the voltage from 240 to 120 and double the current, the power is exactly the same. 120v * 20A = 240v * 10A = 2400W. Though when talking about power tools, air compressors, and such with electric motors, from what I understand, the 240v motors tend to be more efficient and run on less power, but now the argument changes to apples to oranges.
@Engineer9736
@Engineer9736 2 года назад
@@jimparker5185 His point is that you can run twice the amount of current through such extension cord. Either expressed in watts or amperes is irrelevant, it boils down to the same conclusion as the line voltage doesn't change. Two phases with the same wire diameter as they would have done at single phase means that you can draw twice the power from it. But i think this project was already a little bit shortsighted over the top (but perhaps fun if you have lots of time and materials left over), and they have proven that they can run 3 saws and a vacuum cleaner simultaneously on the current setup, so making it two phase is really something for when you're into your tenth year of retirement bored and really don't know anymore what to do.
@idadho
@idadho 2 года назад
How often do you find a 240 circuit available? How many portable table saws or planers use 240? Those are usually shop equipment that might even be hard wired to their individual circuits.
@patricelebrasseur5649
@patricelebrasseur5649 2 года назад
@@idadho dryer and range outlet are 120 /240v Compressor welder pvc heat box and large circular saw are the most likely to be 230v on a job site People usually use spider box in those instance
@idadho
@idadho 2 года назад
@@patricelebrasseur5649 In the US, tools are 110 unless they are shop mount grade/not portable. Nobody takes a 220-230-240v compressor to the job site. A portable welder would have a gas engine to run a generator and probably be 50 amp, at least 30 amp. A 220v saw is a shop saw. They use 220 vs 110 to save on electricity costs. They are a bit cheaper to run. The Teenage Engineer does not know what he is talking about. A 30 amp 240 circuit only has 30 amps per leg. No power tool uses 30 amps on 110. Finding an available 240 circuit is not likely on a job site.
@joenobles1086
@joenobles1086 2 года назад
Now that's a awesome build gotta make one of those thanks for the sharing
@Terkinstein
@Terkinstein Год назад
Wow that little bonus, showing the amp meter while clogging the vac was super interesting. And incredibly enlightening! Thanks Stud pack.
@dandexinventor
@dandexinventor 2 года назад
I like it! The one change I will make is a spool because wrapping cords around static cord storage twists them. I like a detachable cord (from the board), with one of those sunk-in cord sockets, which helps with the spool being simple as well as allows any extension-cord to be use. Thanks guys!
@DingleFlop
@DingleFlop 7 месяцев назад
That's a great idea actually, the retraction mechanisms in those tend to be quite bulky/heavy but it seems perfect for an application like this
@rogerwhiting9310
@rogerwhiting9310 2 года назад
I have been wiring devices all my life. With few alterations I think this was spot on. As usual I would personalize it for my own particular needs...but it was the best homeowner instruction level one yet. I did a 240 volt 50 amp one off of a range plug and a small subpanel. It had 240v, 120v and gfi protection. DEFINITELY not water resistant or OSHA approved. I can weld with it and run anything 120v ..with full breaker protection. Not pretty either.
@c_mac7773
@c_mac7773 2 года назад
Please show me how to make one. I travel a lot doing repairs anything from roofing to repairing/welding damaged hand railing.
@donovandaniel
@donovandaniel Год назад
great info, great delivery, and great comment section. I just fell in love with this channel
@jameswilliams4775
@jameswilliams4775 2 года назад
Came across this video and loved every minute of it. More joy when I realized I was already subscribed! The comment section is absolutely amazing as well. Great community!
@MrTimdtoolman1
@MrTimdtoolman1 8 месяцев назад
As a 20 year contractor I found your video to be very entertaining, educational, and useful. My OCD flared up when you mismatched the colors on the plates and plugs, but AL in all, a great vid guys as usual. Thanks for representing the construction field so well. Keep up the awesome vids.
@sparksmcgee6641
@sparksmcgee6641 2 года назад
Rotate the boxes 90 degrees. The wire on plugs that point down will tangle up across the other plugs. Having them point out instead of along the unit. Great job. Loved the hospital plug info. Great for heavy use and heavy load.
@user990077
@user990077 2 года назад
If you rotate those plastic boxes then the conduit connections become more complicated with tees and would not be inline as they are in that build.
@sparksmcgee6641
@sparksmcgee6641 2 года назад
@@user990077 No changing the device direction doesn't change conduit.
@brandong6204
@brandong6204 2 года назад
The first video I ever saw of yours was the extension cord repair video you mentioned at the beginning. It was a YT recommended video. I've watch every one since, and gone back to watch a lot of your older videos. Keep up the great (team) work.
@larrygriffin3171
@larrygriffin3171 7 месяцев назад
Awesome idea! Love all functionality in this one
@MrTooTechnical
@MrTooTechnical 2 года назад
Hospital grade stuff. Wow. Nice work.
@StudPack
@StudPack 2 года назад
thanks Dave 👍
@bikesandbeyond618
@bikesandbeyond618 2 года назад
I actually made one based on your prior video - and love it.
@StudPack
@StudPack 2 года назад
Cool thx Alan 👍👊
@mrcryptozoic817
@mrcryptozoic817 2 года назад
Me too. It's excellent. The GFCI protects the downstream (by its side) plug perfectly. Griper's gotta gripe.
@nelsonbrum8496
@nelsonbrum8496 2 года назад
I had one just like that first one, I made 10 years ago without GFCI and strain relief. So I bought new outlets and strain relief and upgraded it from "Good" to "Super." 😉👍
@LobotheStoic
@LobotheStoic Год назад
Amazing. Don’t know why I’ve been skipping over this vid since you guys posted it. I’m building this one for myself. Thx.
@larryblaha
@larryblaha 2 года назад
Awesome project idea.. Thanks for all the details..
@JHCCAZ
@JHCCAZ 2 года назад
A small suggestion: The strain relief as mounted at the end of that little extending pipe (instead of being mounted through a plain hole in the panel wall of the box) could snap off if it gets tugged sideways really hard. You could reinforce it by adding a U-shaped 2-hole conduit or pipe strap, screwed to the board near the end of the strain relief.
@keithmills778
@keithmills778 Год назад
You can get strain reliefs that glue right into the box. That's probably a better solution than extending the strain relief further from the box.
@jimthesoundman8641
@jimthesoundman8641 6 месяцев назад
The thing you are speaking of is properly called a "gland nut" as a strain relief is actually what he showed on the first version of the extension cord from the previous video. And I agree, the cord should be fastened to the plywood before that point.
@Moccy.
@Moccy. 2 года назад
Nice job as always guys, love your videos! Not an electrician, just a DIY enthusiast, but a couple things stuck out to me: 1. You only need stranded wire if the wire can be moved around (e.g. the extension cord bit, or in a flexible conduit) - internal to the boxes between devices can be solid without issue, and would be easier to connect. 2. Seems to me if you have a 20-amp receptacle, I think technically you'd need a 20 amp plug on the supply end to physically prevent you from using a 15-amp outlet. I suspect that inline GFCI is only rated for 15 amps. 3. It's a shame the strain relief on this one didn't have the flexible spring to prevent hard angles at the connection. Keep killing it! :D
@monkeysuncle2816
@monkeysuncle2816 2 года назад
I was wondering that, myself: what happens when you try to plug a 20a tool into that extension cord that is plugged into a 15a wall outlet.
@danlux4954
@danlux4954 2 года назад
I would have used solid wire inside there, especially on the ground.
@TheDarthJesus
@TheDarthJesus 2 года назад
@@monkeysuncle2816 It'll always trip, the 20a tool is goign to use more than 12a (nuisance trip threshold for a 15a breaker)
@gn02020202
@gn02020202 2 года назад
@@TheDarthJesus All the portal power tools I have are only 8a. Most 20a tools have some weight to them and will not be carries from job site to job site, such as a drill press, bandsaw, or a lathe.
@TheDarthJesus
@TheDarthJesus 2 года назад
@@gn02020202 oh absolutely. I was simply saying that using the 20a plug on this "super extension cord" for a 20a tool, while plugging it into a standard 15a receptacle (which is rated for 12a continuous current as per the 80% rule) would cause the breakers to trip.
Далее
I Built 4 SECRET Rooms In ONE COLOR!
29:04
Просмотров 7 млн
Art Deco chest of drawers restoration
24:26
Просмотров 57 тыс.
Base Microwave - Built-in
0:16
Просмотров 10 тыс.
How To TAPE and MUD Your DRYWALL | DIY GUIDE
28:14
Просмотров 2,6 млн
Результат невероятен🤯
0:39
Просмотров 10 млн