Тёмный
No video :(

How To PROPERLY Check A Furnace Flame Sensor | Goodman HVAC No Heat 

Quality HVACR
Подписаться 104 тыс.
Просмотров 12 тыс.
50% 1

- SUPPORT THE CHANNEL -
www.patreon.co...
- Check out @TruTech Tools, LTD -
www.trutechtoo... (Use promo code “QUALITYHVAC” to save 8%)
- HVAC TACTICAL -
hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%)
- FOLLOW ME -
Instagram: @qualityhvacr
- BUSINESS INQUIRES -
qualityhvacrtn@gmail.com
- TOOLS I USE -
hilmor lineset cleaning kit:
trutechtools.c...
RLS Refrigerant Press Tool Kit:
www.trutechtoo...
Veto Pro Pac MB5B Tool Bag:
trutechtools.c...
Supco Jumper King:
trutechtools.c...
Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtoo...
Fieldpiece VP87 Vacuum Pump:
trutechtools.c...
Fieldpiece MR45 Recovery Machine:
trutechtools.c...
Fieldpiece Hose Kit:
trutechtools.c...
Fieldpiece SR47 Refrigerant Scale:
www.trutechtoo...
Solderweld Brazing Kit:
trutechtools.c...
Fieldpiece SC480 Meter: www.trutechtoo...
Fieldpiece SC680 Meter: www.trutechtoo...
Fieldpiece SM380V Digital Manifold: www.trutechtoo...
Supco Magnetic Umbrella: www.trutechtoo...
Supco Coolpressor:
trutechtools.c...
Supco Jumper King:
trutechtools.c...
Fieldpiece DR82 Leak Detector:
trutechtools.c...
#qualityhvacr #hvac #furnace

Опубликовано:

 

15 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 54   
@21xd09
@21xd09 6 месяцев назад
Very straight foward and smooth call! I don't know if its just me, but cleaning the flame sensor is very satisfying. Also that inducer motor sounds like a blown civic engine idling.
@willwise9445
@willwise9445 6 месяцев назад
It’s between you and Curtis “HVAC GUY” for the residential Goat on YT.
@markcotter2355
@markcotter2355 6 месяцев назад
You should try cleaning the sensors with emery cloth or a dollar bill. The sand paper and wire brush ones actually cause the sensor to get dirty faster and more issues with the rod.
@John-dp3ln
@John-dp3ln 6 месяцев назад
4/0 steel wool works great also
@OcRefrig
@OcRefrig 6 месяцев назад
Great video ! Like u say testing is Allways best. NOT TESTING = GUESSING. Also - like u say - it’s awesome to see actual results from a Test. Bad reading before. Good reading when new part is installed / cleaned etc.
@topher8634
@topher8634 6 месяцев назад
Inducer sounds like its ready to give up the ghost.
@samuelg3586
@samuelg3586 6 месяцев назад
Hell yeah. I do the same thing. If a customer decides to invest in an expensive repair I like to give them a little more value by checking gas pressure and cleaning up a few things for them.
@MyBallzGotShocked
@MyBallzGotShocked 5 месяцев назад
id bet money the flame sensor wasnt the problem. most boards especially goodman will operate down to .7 micro amps without fault. inducer motor maybe, but id pull the control board off the mount and inspect the solder joints of the pcb relays. i find lots of faults there with intermittent problems. a quick dab of new solder with a hot soldering iron has saved my clients alot and saved me from call backs and waiting for a board replacement.
@roughstonerolling
@roughstonerolling 3 месяца назад
This video saved me some real money. Thank you!
@richardthomas1743
@richardthomas1743 6 месяцев назад
Good job , if I was in that area and needed my system repaired or replaced you would be the one that I would call. 👍
@zahedaminullah6934
@zahedaminullah6934 6 месяцев назад
Good vid there, name of the angle bit driver attached to ur drill, if you can send an amazon link plz and thanks
@mrcoollu9662
@mrcoollu9662 6 дней назад
Hey what’s that red tool you use for the flame sensor
@zekenzy6486
@zekenzy6486 6 месяцев назад
Great Video. Thank you for sharing
@user-su5ft8lc9q
@user-su5ft8lc9q 6 месяцев назад
Why don't you use Hundred Dollar bills like Ted Cook? Why use that cheap thing that scratches the flame sensor up.?
@williamgildea8348
@williamgildea8348 6 месяцев назад
Great video once again. What brand is that angle adapter for the drill? Keep up the awesome work
@paulrozinski1488
@paulrozinski1488 6 месяцев назад
Burner flames were nice and blue so I don’t think they’ll give you an issue. 👍
@waterhill623
@waterhill623 6 месяцев назад
Is there a reason you don’t put your company name on your van
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
This dude is HVAC famous. Probably doesn't want the attention. When you are HVAC famous, it's difficult to keep the ladies away. Lol!
@robalexander7348
@robalexander7348 6 месяцев назад
Thank you Zac, a good easy job,a nice video 👍 Au
@robalexander7348
@robalexander7348 6 месяцев назад
@QuaIityHVACR. Sure any time Zac
@ryandeeg2538
@ryandeeg2538 6 месяцев назад
What was the tool you used to clean the flame sensor? I usually just use like a dollar
@HVACRTECH-83
@HVACRTECH-83 6 месяцев назад
Supco flame rod cleaner. I keep one on each of my bags,I hang it off the zippers though to keep them clean. If you don't have that use a scotchbrite pad or fine steel wool. A dollar? Not cleaning much using a dollar bill. You can use the brown sandcloth with the holes in it as well just don't use blue monster sandcloth or actual sand paper since it has silica
@maness2112
@maness2112 6 месяцев назад
What is a good milli amp reading and a low milli amp reading on that rectification reading?
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
Nice vid man, nice company shirt too! We run those at the company I work for as well.
@mauriciomendieta1889
@mauriciomendieta1889 6 месяцев назад
Do you know what brand is the shirt?
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
@@mauriciomendieta1889 Carhart
@daviddios6513
@daviddios6513 6 месяцев назад
I could be wrong but i dont think thats a proper drip leg on the gas line ?
@johnsutter1497
@johnsutter1497 6 месяцев назад
What was the name of that cleaning tool? Thank you
@relly4988
@relly4988 6 месяцев назад
@quality hvacr….have you ever ran into a problem were a new system install was burning to much propane
@randyshope4744
@randyshope4744 6 месяцев назад
If the manifold gas pressure was not adjusted to manufacture specifications that will happen and also cause buildup on the burners and flame sensor. There should have been a lp sticker placed on the unit door for lp gas manifold pressure. The newer efficiency furnaces should be 2.3 iwc in low and 9.3 iwc in high fire.
@bills6946
@bills6946 6 месяцев назад
80,000 btu furnace with 12” return. Furnace needs more return.
@topher8634
@topher8634 6 месяцев назад
It looks like there is a return duct on the left as well. I guess there are 2 filters in the blower compartment. Or maybe some filter grilles.
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
12" would be too small, but I saw 2 return ducts going to it
@topher8634
@topher8634 6 месяцев назад
@@hvacgoat9451 it looks like a duct was added because it wasn't tapped into the return plenum. Probably realized there wasn't enough return after the rough was done.
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
@@topher8634 true
@Negative13Prod
@Negative13Prod 6 месяцев назад
I prefer to use fine sandpaper
@dronetherapy5800
@dronetherapy5800 6 месяцев назад
If not a secret, what are you using to record? An iPhone or something else?
@zeph352
@zeph352 6 месяцев назад
everything can be done with knowledge, life is easier and more money
@choppergunner1408
@choppergunner1408 6 месяцев назад
That inducer is missing a cooling wheel
@ssFaxes
@ssFaxes 6 месяцев назад
did it trip on no flame off camera?
@two5246
@two5246 6 месяцев назад
if you listen closely on the first fire it goes out immediately and starts the ignition cycle over
@harrygilbert4593
@harrygilbert4593 6 месяцев назад
The inducer failed right after you left. Goodman quality
@lonewanderer9872
@lonewanderer9872 6 месяцев назад
Lolll
@scott1134
@scott1134 6 месяцев назад
#1 issue with goodman is the guy installing is usually a hack.
@daygoingward918
@daygoingward918 6 месяцев назад
The drip leg is wrong . For sure seen that on a couple of your videos
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
What's wrong with the drip leg?
@daygoingward918
@daygoingward918 6 месяцев назад
@@hvacgoat9451 I could be wrong but doesn’t the incoming gas have to shoot straight into the drip leg . Hence catching the debris .
@daygoingward918
@daygoingward918 6 месяцев назад
Oh yeah I looked back on the video it’s wrong . Not being mean , you know a lot more about hvac than me . BUT that debris can get into a small orifices like txv or pistons . And mess up the whole system .
@hvacgoat9451
@hvacgoat9451 6 месяцев назад
@@daygoingward918 oh gotcha, yeah, that makes sense. It would be better for sure if it was changed, but not too big of a deal. I'll keep an eye on the way gas hits the leg during its path of travel. Thanks
@daygoingward918
@daygoingward918 6 месяцев назад
@@hvacgoat9451 keep up the great work/content ! Thanks for taking the time to read my comments!
@nickv255
@nickv255 6 месяцев назад
How do you get away with filming in people's homes ?
@Mx2J
@Mx2J 6 месяцев назад
if it fails on a no heat, replace it. if its dirty during a maintenance clean it.
Далее
❌Разве такое возможно? #story
01:00
Furnace Not Working - Troubleshooting the Flame Sensor
17:05
Heat Pump System FAILED In FREEZING Temps!!
8:55
Просмотров 22 тыс.
HVAC Heating Maintenance | Gas Fired
9:49
Просмотров 10 тыс.
Boiler Flame Failure, 50 Apartments with No Heat
15:35
10 Furnace Cleaning and Maintenance Pro Tips
27:30
Просмотров 132 тыс.
Furnace Troubleshooting Step by Step with Multi Meter.
26:33
Lennox (G43UF) Flame Sensor Cleaning Tutorial
15:31
Просмотров 27 тыс.
Ultimate HVAC Overhaul: Bearing, Vents & Aquastat
16:03