How to troubleshooting drink vending machine's cooling system while on location 

Vending Machine Support
Подписаться 5 тыс.
Просмотров 28 тыс.
50% 1

Опубликовано:

 

24 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 68   
@GlitchedAngel21
@GlitchedAngel21 10 месяцев назад
Thank you as a new vending machine owner who’s machine stopped cooling I greatly appreciate this because I don’t wanna pay someone a but load to come out and take a look and now thanks to this I have the confidence to check for myself!
@SandipMehta-q6e
@SandipMehta-q6e 8 месяцев назад
Great video and very helpful information. I did the tests and condenser and evaporator fan works fine along with thermostat. I noticed next to evaporator coil - notice a chunk of ice build up. After thawing it, ran the 15 mins test as you recommended, I see some frost. What would cause the ice build up next to Evaporator coils (looks like kidney bean)?
@koutakleinschmidt343
@koutakleinschmidt343 Год назад
Wow, must be a very good refrigeration mechanic you got there!
@VendingMachineSupport
@VendingMachineSupport Год назад
I like to think I do.
@jdvanguy296
@jdvanguy296 5 месяцев назад
Dude, your videos are saving my ass, I'm new to the business and your videos have helped me greatly. Thank you for what you do.
@josephburns1037
@josephburns1037 11 месяцев назад
Great video. Thanks Alex.
@dustymorrison6744
@dustymorrison6744 8 месяцев назад
Just watchedbuour video very helpful after the tests i come to learn my compressor is not turning off. Inthought it wasnthe thermostat. So i replaced it and found this problem. Does that mean i need a new compressor? Im new to vending machines.
@jasmingresham2108
@jasmingresham2108 8 месяцев назад
This is such an informative video. My machine is triggering the breaker making it go out at its location. Do you know if that is because of the fan or the condenser?
@h.b4517
@h.b4517 6 месяцев назад
I have a KM series machine. It's only a year old and its getting louder. From your video I believe it's the evaporator fan. The one that is always on, what should I look for if it is getting louder? I removed the back and made sure it's not sure it's not sucking up dust. I just don't know what to do now.
@richardbohnert1140
@richardbohnert1140 Год назад
Ok one thing that we should do with these machines is blow out your condenser coils. This should be the first thing that you do. I work on ice boxes for a ice company. If you can't see thru them it's not a good sign.
@VendingMachineSupport
@VendingMachineSupport Год назад
Excellent tip Richard. I should have mentioned that. Thank you for sharing.
@RandyNO6
@RandyNO6 8 месяцев назад
Hey when you say blow them out what do you mean? And what would you suggest doing that with?
@richardbohnert1140
@richardbohnert1140 8 месяцев назад
You can do that with compressed air.
@wallysensei
@wallysensei 10 месяцев назад
Hello, recently my 501e went warm and the machine is tripping the outlet whenever the compressor is plugged in within the machine.. Is it time for a new compressor? Thanks for all the info you provide
@sampatel2021
@sampatel2021 11 месяцев назад
Thanks for the video and info. I checked my Dixie narco 276e machine and evaporator and condenser fan is fine but not cooling. I did the 15 mins test as per video and no frost in the evaporator coil. Does this signify the compressor is bad or leak?
@judycruz6023
@judycruz6023 Год назад
Hi. My Royal 650 has a lot of ice build up around the entire evaporator coil. How can I thaw it out while preventing any leaks at the location? Where should drip pans be placed? Should I remove the chute like you did in your test?
@VendingMachineSupport
@VendingMachineSupport Год назад
You will want to unplug the machine and let the ice melt off while keeping a towel near the bottom of the machine to soak up any overflow water. You can also use a hair dryer to help accelerate melting the ice. Please do not chisel or poke at the ice as this can damage the evap coil.
@Oasis_Vending
@Oasis_Vending Год назад
​@@VendingMachineSupporthow do you test the electronic temperature sensor on a Royal 650?
@aedinquinn8687
@aedinquinn8687 Год назад
Dud refrigeration tech replace compressor? What was diagnosis? Aedin
@amason9801
@amason9801 Год назад
hey do you have anymore info on the vendos I just bought one and would like to find more info or videos on it
@VendingMachineSupport
@VendingMachineSupport Год назад
I hope to have some recorded in the future.
@austingrant5660
@austingrant5660 Год назад
Same here bro there no videos on them i got my compressor working right ,i can,find the evaporator fan well I mean I can't find a way to get to it , anyways. You should,post a video of your vendo machine
@nicholasdcarlson
@nicholasdcarlson Год назад
My compressor is hot and the soda isn’t cooling but the tubing feels cold thanks for your help!
@VendingMachineSupport
@VendingMachineSupport Год назад
Is your Evap fan working as shown in the video?
@lentil61
@lentil61 7 месяцев назад
Thank you for your videos. They are awesome. I have a Vendo 720 and the evaporator it's icing over. I'm not sure how to test the thermostat to see if it's bad before I have to replace the compressor. Any help?
@fields5003
@fields5003 3 месяца назад
Did you ever figure it out?
@d.o.cthebarber9096
@d.o.cthebarber9096 2 месяца назад
Hello there and thank you for your very very helpful videos. So my question is checked the condenser fan and it was good then the evaporator fan and it did not turn on so did the evaporator coil test and it froze up like in the video does that mean it needs to be charged too or is that caused due to the fan not working?
@FunnyRandomz4U
@FunnyRandomz4U 2 месяца назад
It either means the fan has gone bad or the relay has gone bad. You can check to see if your evaporator fan is running in the back. That will be a pretty clear sign it is time to replace your evaporator fan.
@flawlesssnipes630
@flawlesssnipes630 5 месяцев назад
So it looks like it’s my compressor fan do you have a video of a replacement ?
@UFObuilder
@UFObuilder Год назад
Thanks for the information 👍
@VendingMachineSupport
@VendingMachineSupport Год назад
Happy to learn that you found this useful.
@donnieb7818
@donnieb7818 Год назад
I just bought a royal 660-9 & having the same problem with the machine , I can't get the compressor to turn on when it's plugged into the power harness but when I unplug the compressor & plug it into an extension cord the compressor kicks on no problem, I'm brand new to this vending business & would appreciate your expertise, Thanks!!!
@VendingMachineSupport
@VendingMachineSupport Год назад
@Donnie B From your description and trouble shooting steps. It sounds like you could have a faulty refrigeration relay. The Royal 660 was designed by Coke-Cola but manufactured by Royal Vendors for Coke Asset Operators. The 660 shares some similarities to the Royal 650. I have several videos about the Royal 650. Two of which deal with the refrigeration relay. This relay can be tested from the control board to determine if it opens and closes. The 660 uses a four button programing as the Royal 650 uses the a three button programing. Though the concept I show in the videos can be applied to the 660. How to test the Royal FRIG relay: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-yIgDyCrBk4Q.html Troubleshooting a Royal FRIG relay with a voltmeter: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-5SYYrIn3tYs.html If the relay opens and closes when tested with a voltmeter then the issue is the actual power junction assembly that the compressor plugs in to. I hope the gets you pointed in the right direction. Thank you for watching and supporting.
@donnieb7818
@donnieb7818 Год назад
@@VendingMachineSupport Thank you sir, I'm gonna take a look at it today, I appreciate the info Thanks 👍
@burnoutawd
@burnoutawd Год назад
I have a dixie narco 276 just restored the entire machine. Replaced the compressor housing with a new compressor and rebuilt evaporator and condenser. I noticed the compressor will run 15min on and 15min off ranging from 35°-37° new thermostat. This unit is installed in my basement which is about 65°. Is this the normal cycle? Or should I start looking for some kind of air leak? I also for the first time fully stocked the machine full of room temp cans and it took almost 6 hours to reach 35 degrees. My evaporator in 15 minutes looks exactly like the one in your video. I found quite a few other videos that say that is perfectly normal, including the company that I bought the refurbished compressor deck from lol. When you had yours looked at, did they say there was something wrong with it??
@VendingMachineSupport
@VendingMachineSupport Год назад
From your description it sounds that everything is working ok in your machine cooling wise. Drink vending machines are not energy efficient like your typical modern refrigerator.
@joewilliams5283
@joewilliams5283 Год назад
I recently purchased a Vendo 516. The condenser isn't getting cold. I can't find ANY information on replacements. Do you have any suggestions or if there are replacements for it?
@VendingMachineSupport
@VendingMachineSupport Год назад
The Vendo 516 is an older Vendo unit and new units are hard to come by. I would look for a locally owned and independent HVAC mechanic or appliance repair to have a look at the unit. These cooling decks are very simple in the grand scheme of cooling units.
@Era_JustBelieve
@Era_JustBelieve Год назад
My location lost power recently and reset my whole Royal 650 drink machine. Prices went to .50 cents and now it’s cooling warm air. What’s the exact settings for this machine to get it cold ?
@raulperez5471
@raulperez5471 Год назад
Compressor seems to work and the evaporator coil is getting cold but I don't see The frost built as seen on your video. I can see light frost on the sides and on the tube in the front.
@VendingMachineSupport
@VendingMachineSupport Год назад
Your unit may be low on charge or has a blockage in the lines. Might want to call in a HVAC mechanic.
@ethanirwin3615
@ethanirwin3615 Год назад
I’m try to diagnose my Dixie-Narco and it fails the thermostat test but it also doesn’t get frosty on the coils. Should I replace the thermostat and try the frost test again?
@VendingMachineSupport
@VendingMachineSupport Год назад
@Ethan Irwin If the evaporator coils did not get frosted over within 15 minuted when connecting the compressor directly to power (which bypasses the thermostat). Then replacing the thermostat will not produce a different result. Make sure when you tested the compressor you did this with the machine unplugged from the wall and the compressor connected directly to power via an extension cord.
@raulperez5471
@raulperez5471 Год назад
My condenser fan takes time to turn on is that a concern? When it turned on, I moved the Thermostat to 0/0ff and the fan turned off. Does the fan take a while to turn on or is it supposed to be immediate
@VendingMachineSupport
@VendingMachineSupport Год назад
Typically the condenser fan should start as soon as power is applied to it. Unless there is a time delay device which I have only seen once. If the condenser fan is taking some time to start up there is a good chance that it is also not running at full RPM. In turn reducing the amount of air that is pulled through the condenser coil and over the compressor head. This causes overheating and problematic cooling issues.
@geminivending
@geminivending 10 месяцев назад
Hey 👋 there
@nelsonrosado4215
@nelsonrosado4215 2 месяца назад
The magnets aren't spinning fast enough on my vendor jet spray machine. What can I do to speed them up
@beatricecarrizales2296
@beatricecarrizales2296 5 месяцев назад
I have a vendo 721 and my evap is completely frozen when i open machine cond fan isnt on but wondering if i have a eco system machine how would i be able to tell?
@josedavidgamez5026
@josedavidgamez5026 Год назад
So what is happening when the coke cans are over freezing literally lost like 40 cans due to them bursting in machine . It was winter in Texas but last month could drinks have over froze due to outside temperatures?
@VendingMachineSupport
@VendingMachineSupport Год назад
You need to establish what is the temp inside you machine. Stick a thermometer in the machine. You are looking for temps between 40F to 36F. Diet drinks freeze at 34F while other type of drinks and water will freeze at 32F. If the temp in your machine balances out between 40F and 36F after letting the machine run for a few hours. Then the freezing cold be due to outside temps.
@ricktumaniec6820
@ricktumaniec6820 Год назад
I have an 85 coke machine, cools great but the condensation won't drain to the pan or through the hose to the pan. how do I unclog it?
@VendingMachineSupport
@VendingMachineSupport Год назад
Try running a long brush through the pipe.
@brianiswrong
@brianiswrong Год назад
Or connect a few cable ties together and poke it down the drain hole (under the evaperator) until you see it poke out the end of the tube.
@soup3rd609
@soup3rd609 Год назад
The whole back part and pipes are just pure frost and it’s not warming up the drinks. What might be the exact issue for that?
@VendingMachineSupport
@VendingMachineSupport Год назад
Check to make sure the evap fan is running.
@MichaelBeechy-zn8vo
@MichaelBeechy-zn8vo Месяц назад
who do you call to come out and service them
@christoffer4862
@christoffer4862 Месяц назад
The owner of course
@MichaelBeechy-zn8vo
@MichaelBeechy-zn8vo Месяц назад
@@christoffer4862 course?
@thirdgearboogie2210
@thirdgearboogie2210 Год назад
AMS 39 VCF That keeps leaking water on the floor. How do I fix this.
@VendingMachineSupport
@VendingMachineSupport Год назад
There is a drain hose that takes the water coming from the pan that sits beneath the evap coil and deliveries it to the drain pan. Check to make sure the hose is attached correctly or not clogged. Also make sure the hose is actually sitting in the drain pan.
@scottytroublefield205
@scottytroublefield205 Год назад
Mine is freezing up can you tell me what may be causing it??? DN 501e
@scottytroublefield205
@scottytroublefield205 Год назад
My motors at bottom and top are working.
@VendingMachineSupport
@VendingMachineSupport Год назад
Possible could be the thermostat not shutting down the compressor or the machine is leaking outside air in.
@jesusdiosdado4974
@jesusdiosdado4974 5 месяцев назад
My compressor came on but my fan don't come on
@jamalhinds1
@jamalhinds1 Год назад
So my Coils are froze up in a block of ice, I check the thermostat like you said in the video turning it until the compressor kicks on and off. While the compressor is off I was able to hear the blower fan behind the block of ice also I can see the compressor fan spinning. I shut the machine down for a day to let ice thaw to visually inspect the coils there was some slight browning at the bottom but not much. With the machine back on for a day I returned and the ice started build back up, please help.
@VendingMachineSupport
@VendingMachineSupport Год назад
What happened to the evap coils after running the compressor directly to power for 15 minutes with the machine unplugged?
@jamalhinds1
@jamalhinds1 Год назад
The pass through is on the left side of my machine. Will the deep refrigeration unit on DSV still work
@franciscaramirez2342
@franciscaramirez2342 Год назад
Hello sir so i got a beat up choice vendo machine and i mean the i had to do body work to it the door was bend Ll bad anyways i was real proud of my self cus i fix the door i also got the compressor and the fan aslo the condenser n fans anyways so i was excited right but once i check it to see if it was cold i was shocked it was not cold becus everything was good any ways i been try to see whats up with that and my guess is could the capillary tube need to be replaced cus its look bad its all original from the late 1960s any ways hope to hear from you sir gracias
Далее
МЭЙБИ БЭЙБИ - Hit Em Up (DISS)
02:48
Просмотров 221 тыс.
Team Spiderman True Or False Mask,nono #Shorts
00:37
Coinco Bill Validator Troubleshooting
7:46
Просмотров 59 тыс.
Our Dixie Narco 501e Vending Machine Was FROZEN!!!
16:03
Dixie Narco Vending Machine: Jams & JC Errors
9:41
Просмотров 11 тыс.
Replacing a Bad Cooling Deck in a Soda Machine
26:50
Просмотров 19 тыс.
МЭЙБИ БЭЙБИ - Hit Em Up (DISS)
02:48
Просмотров 221 тыс.