Good Video👍 I hope you do more Mitsubishi Repair Videos, I took the 2 Day Mitsubishi class three times in the last 11 years hoping they will have more in depth repair, but it’s always the same type of basics, I think the distributors gets worried that something will get torn up in the units..
Good to see your vid ,was hoping to see at the Ahr Mitsubishi stall did ask about you sir ,they should've had u there more knowledgeably and recognizable rep for sure 👍🏻
Nice job Ralph. It been too long with out your vids. I believe you said you would never replace R22 with drop in (could be wrong). Please check out Bluon R-458A. I really looks good. Please give a look at it and any thought. Over here in Afghanistan and the price we are paying for R22 is criminal. We use it, R410A, R407C, R134A. Thats pretty much all govt units.
It depends on which unit you are looking to put in. Mini splits don’t look at humidity some are better then others. You have to look at the submittal for the unit you’re looking to put in. Getting back to the stranded Communication wire. We only require stranded wire for Communication when you are installing a branch box system. Then from the outdoor unit to the branch box it has to be 16/2 stranded shielded. All other one to one or ported units can use 14/3 with a ground solid or stranded wire.
I’m still alive Patrick, with the job I have now I don’t have to content I use to have. Stick around though. I will post from time to time. Thanks for the comment!!!!