Тёмный

HQST MPPT 20A 40A 60A Lithium Solar Charge Controller Review 

HOBOTECH
Подписаться 201 тыс.
Просмотров 58 тыс.
50% 1

The Professor reviews the HQST 20A 40A and 60A MPPT solar charge controllers for use with Lead or LiFePO4 12v 24v 36v 48v battery banks. Includes built in Parallel Ability, Bluetooth, and Low Temperature Charging Protection!
CHECK OUT HQST MPPT: gohobo.io/hqstmppt use code HOBOTECH10
DISCOUNT CODES on SOLAR PANELS - GENERATORS - REFRIGERATORS
hobotech.tv/amazon
SUBSCRIBE To BLOG (e-mail notifications)
hobotech.tv/blog/
FACEBOOK GROUP
/ hobotechcrew
SNEAK PEEK of UPCOMING products
/ hobotech
HAS THIS HELPED YOU?
Buy me a coffee! You'll automatically be subscribed to e-mail notifications!
www.buymeacoffee.com/HOBOTECH
// - GENERATORS - //
BLUETTI AC500 5000w Modular UPS LFP Generator BEST BUY
gohobo.io/ac500 use code HOBOAC500
ECOFLOW DELTA PRO 3600w Modular UPS LFP Battery Generator BEST BUY
gohobo.io/CkOL use code EFHOBOTECH50
Amazon + tax amzn.to/3MlPzCq
ECOFLOW DELTA II 1800w LFP Generator BEST BUY
gohobo.io/delta2 use code EFHOBOTECH50
BLUETTI AC300 3000w Modular UPS LFP Battery Generator RECOMMENDED
gohobo.io/nYHw use code HOBOAC3001B
CANADA? shrsl.com/3hl1v
Amazon +tax amzn.to/3MuBYZt
BLUETTI AC200MAX 2048 Modular Battery Generator RECOMMENDED
gohobo.io/goXO use code HOBO200MAX
CANADA? shrsl.com/3hl1v
Amazon +tax amzn.to/3rPywky
JACKERY Explorer 2000 Pro RECOMMENDED
gohobo.io/jackpro use code HOBOTECH
JACKERY Explorer 1000 Pro RECOMMENDED
gohobo.io/j1000p use code HOBOTECH
BLUETTI EP500 PRO 5100wh UPS LFP Battery Generator
gohobo.io/ZvQy use code HOBOEP500
CANADA? shrsl.com/3hl1v
BLUETTI AC200P 2000wh LiFePO4 Battery Generator
gohobo.io/X6ys use code HOBO200P
CANADA? shrsl.com/3hl1v
Amazon +tax amzn.to/3xBp6u4
JACKERY Explorer 1500
gohobo.io/CweA use code HOBOTECH
Amazon +tax amzn.to/3jfi8pV
CANADA amzn.to/3fZ4aX1
JACKERY Explorer 1000
gohobo.io/vqkr use code HOBOTECH
Amazon +tax amzn.to/38TEJiR
CANADA amzn.to/3d7ll5g
BLUETTI EB70s 800w LiFePO4 Generator
gohobo.io/nBuo use code HOBO70S
CANADA? shrsl.com/3hl1v
BLUETTI AC50s 500wh Generator
Use code HOBO50 gohobo.io/uCK6
Amazon + tax amzn.to/36fwWg0
CANADA? shrsl.com/3hl1v
MAXOAK BLUETTI 2400w
gohobo.io/Q3uo use code HOBO3000
CANADA? shrsl.com/3hl1v
Amazon +tax amzn.to/33UZKcj
ECOFLOW RIVER PRO
gohobo.io/2fTn use code EFHOBOTECH20
Amazon +tax: amzn.to/3Ms9Iqx
Jackery Explorer 500
gohobo.io/ZiRP use code HOBOTECH
Amazon +tax amzn.to/2XWA3bl
CANADA amzn.to/2mI0CQf
JACKERY Explorer 300
gohobo.io/MZWw use code HOBOTECH
Amazon +tax amzn.to/3lCbbhl
CANADA amzn.to/3bPwPfO
Jackery Explorer 240
gohobo.io/bBPu use code HOBOTECH
Amazon +tax: amzn.to/2VOL51s
CANADA amzn.to/2pj5Rah
//-- SOLAR PANELS --//
BLUETTI 350w Solar Panel RECOMMENDED
gohobo.io/ayja use code HOB350 for best price
CANADA? shrsl.com/3hl1v
BLUETTI 200w Solar Panel RECOMMENDED
gohobo.io/f4UB use code HOBO200
CANADA? shrsl.com/3hl1v
On Amazon + tax amzn.to/30AXTs9
BOUGERV 180w Solar Panels RECOMMENDED
gohobo.io/ziEW use code HOBOTECH
Amazon +tax: amzn.to/370r0px
RENOGY SOLAR PANELS RECOMMENDED
gohobo.io/8tvB use code RENOGYSOLAR10
//-- BOOSTERS --//
HIBOOST 4G Signal Boosters gohobo.io/23IS
Use code HOBO20 for 20% off ALL mobile boosters!
Use code 15OFF for 15% off SITE WIDE!
HOBOTECH is viewer supported. When you buy through these links we may earn an affiliate commission. As an Amazon Associate I earn from qualifying purchases.
SUPPORT THE CHANNEL
To shop directly on Amazon for products not on our store page you can use this link: amzn.to/2utihvF
HOBO STICKERS, T-SHIRTS, MUGS, BEANIES, ODIN MERCH
hobotech.tv/shop/
DONATIONS
hobotech.tv/support/
GET SOCIAL
Facebook Group: / hobotechcrew
Instagram: / hobotechtom
Hobo HQ: www.hobotech.tv
BUSINESS INQUIRIES / E-MAIL
hobotech.tv/contact-us/
NOT a free help line! Business only!
============================
#reviews #chargecontroller #solar #offgrid #DIYsolar #boondocking #rvlife #rvliving #vanlife
============================
LIKE COMMENT SUBSCRIBE!
(c)2023 hobotech.tv

Опубликовано:

 

5 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 281   
@HOBOTECH
@HOBOTECH Год назад
The Professor reviews the HQST 20A 40A and 60A MPPT solar charge controllers for use with Lead or LiFePO4 12v 24v 36v 48v battery banks. Includes built in Parallel Ability, Bluetooth, and Low Temperature Charging Protection! CHECK OUT HQST MPPT: gohobo.io/hqstmppt use code HOBOTECH10 [PROOF 20A/40A controllers also have LOW TEMP CUTOFF ru-vid.comsRsq9YqlLxk ]
@Mae-nr7wr
@Mae-nr7wr Год назад
where is da ecoflow delta 2 max review !!!
@Fogatti910
@Fogatti910 Год назад
Awesome!!
@afolayandammy9161
@afolayandammy9161 11 месяцев назад
What is the name of the bluetooth app please
@5thdayadventures
@5thdayadventures 10 месяцев назад
Looks like the code HOBOTECH10 is no longer being accepted
@charlestresnicky1144
@charlestresnicky1144 8 месяцев назад
Thank You Professor! I got the 40amp while on sale and set it up this weekend, hoping to upgrade later on panels and run another 40 amp parallel. Cheers
@vidzilla1
@vidzilla1 Год назад
I have been using this solar charger controller for 8 months, very happy with it !
@jtnoodle
@jtnoodle 9 месяцев назад
update us in a couple years.
@d.l.sstudio8922
@d.l.sstudio8922 3 месяца назад
@@jtnoodleI’ve had mine for 9 months or so now and it’s been perfect. I bought a second 60A controller to charger for a total of 120A! Haven’t installed the second yet but will soon.
@airinbone
@airinbone Год назад
This is my choice in price range. It offers so much.
@iggykoopa7756
@iggykoopa7756 Год назад
I have had mine for a bit over a year, its hooked up to 3 110ah 12v deep cycles with 3 renogy solar panels running into it. Works awesome and ive been really impressed with it.
@astrobob9432
@astrobob9432 Год назад
I have had the 40amp model for about the last year. No real issues with it yet. I was unaware of the low temp cutoff feature, thanks for showing us! Go Hobo!
@davidgunther8428
@davidgunther8428 Год назад
I picked up the 40A charger a few months ago. Having built in Bluetooth and the low self power consumption were the selling points.
@Cabernet2000
@Cabernet2000 Год назад
Ordered the 60. Thank you, HOBO. Will buy 20,40 later as I expand versatility. Just getting going.
@jamesthompson7282
@jamesthompson7282 Год назад
Great review of a good product with extensive feature set at a VERY competitive price. Prof. Hobo delivers!
@mkuhlman77
@mkuhlman77 Год назад
I've been using the 20A version for 3 years now and love it. I was just thinking about get more power but noticed I'd already maxed her out. I didn't realize you could add another controller. This is great news. Thanks for the review. I'll keep buying these over Renergy any day .
@wndy7073
@wndy7073 Год назад
I want to get this; 10% off of $89.oo on this 20 amp model would be a fantastic bargain 😀
@junkerzn7312
@junkerzn7312 5 месяцев назад
You can put as many charge controllers on your battery as you want, up to the current limit that the battery supports. Though its nice (they all switch charging stages simultaneously when they have comms)... charge controllers don't actually need to know that there are other charge controllers on the system. So if you have a battery bank, bus bars, and battery wiring that can handle charging at 100A, nothing is stopping you from putting 5 x 20A charge controllers on the system. (Each charge controller being only 20A can use 10 AWG wiring. The battery cabling itself would have to be 2 AWG to handle 100A reasonably well). For the same reason, you can hang multiple inverters off of a battery bank such that the total amperage they pull does not exceed the bank/wiring capabilities. -Matt
@svenshanah
@svenshanah 6 месяцев назад
Funny Fact; I was about to get the Victron..I was so set on it that I had this video in Que way back when it was new, and ignored this video because due to issues with cheaper stuff, I was done playin'.. Well, as life goes I got side tracked on other projects and I'm just now getting around to playin' with my solar stuff again, and I decided to hear this video out, only to hear this basically is a Victron - so I just went from buying one Victron at a time to three of these 60 amps (I'm going 48v on this next system, and my bugout location gets in the single digits), and I'll be way better off for it. Thanks Professor..😎👍
@Datzneat
@Datzneat Год назад
Picked one up to replace the pwm charger that came with my old flexible Renogy panels. Just need a good inverter charger and the cabling/tools to make it all work now. Thanks for the discount.
@mikeh1589
@mikeh1589 Год назад
Thanks HOBOTECH. You saved me some money on some HQST 60 Amp charge controllers 😎
@davef.2329
@davef.2329 Год назад
These controllers are great. We now have 4 of them in service and after installing the first one, replaced 3 other functional units of other brands with these, since they work so well. Have a variety of panels from them that work great, too. Good, reliable, quality equipment.
@mrdemascal
@mrdemascal 2 месяца назад
Do you have various watts/amps strings of panels running to them? I have 2 400w strings paralleled into our current 60A unit. Want to add 400 to 600 more watts with a 40 amp controller. From your experience will having 600watts on one controller and 800 on the other decrease the input from the 800 unit? Hope that wording makes sense?
@texasprepperprojects
@texasprepperprojects Год назад
I have the 20amp when I built my solar cart. I was pleasantly surprised with the bluetooth app. I also have their solar panels. I think that their pricing is great and I was pleased with the build quality.
@junkerzn7312
@junkerzn7312 5 месяцев назад
HQST has some great solar panels. The 9BBs and now 10BBs are great panels.
@HoosierOutdoor
@HoosierOutdoor Год назад
Low temp cut-off in a budget controller.. without paying the big blue price.. this is gonna be my next controller
@BobBob-il2ku
@BobBob-il2ku 11 месяцев назад
Same
@rickreid5896
@rickreid5896 8 месяцев назад
Send their customer support an email saying your having trouble with a unit you just bought. No answer. Send them another one to the same customer support saying you want to buy there 60a controller. Wow, you just got an answer but not about that first email.
@Mr.Avuncular
@Mr.Avuncular Год назад
Thanks professor for the heads up and great price Bang bang!
@trumpingtonfanhurst694
@trumpingtonfanhurst694 Год назад
I always enjoy your vids, thanks hobo 😊
@rtpman1953
@rtpman1953 Год назад
Thanks for the well-done video. I've been using a MPPT controller that handles the same voltage/amps but no parallel. If I factor in the Bluetooth app instead of a remote display, it makes sense to slowly switch over to this.
@Banagal
@Banagal Год назад
Thanks for this review.
@austindishman6338
@austindishman6338 Год назад
Thank for doing the short video to answer my question
@stevecarlisle3323
@stevecarlisle3323 6 месяцев назад
Would be very helpful if you explain Advanced Settings mode, and what options are available. Thanks for the video.
@pdieppa
@pdieppa Год назад
Yes!!!! Thank you for the fx!!!!
@KA9DSL
@KA9DSL Год назад
It looks more friendly user and more versatile than my Renogy MPPT. Nice price. Might order one!
@jalindell
@jalindell Год назад
Heck yeah, I have the small one the 20amp and I love it.
@Golfreak
@Golfreak 11 месяцев назад
I have the same exact HQST but 40a version. It is rock solid and runs very cool. I find the parallel feature not needed. I have the HQST and a SCNE 20a mppt both charging the same battery bank and it's not a problem.
@junkerzn7312
@junkerzn7312 5 месяцев назад
Right. You don't need the paralleling feature. The worst that happens is that the various charge controllers don't switch charge stage states in tandem. That can be a bit of an eyesore but it doesn't really hurt anything.
@thedabbler2753
@thedabbler2753 11 месяцев назад
I have the 60A. A couple of other things of note. DC load terminal control (dusk/dawn/timer) and battery charge parameters can be controlled completely from the app. Regarding the auto 12/24/48v claim on the front, what I found was that it wasn't actually auto. What happened on switching from 12 to 24v LI was that it registered 26.5v coming in and flashed the error light at me until I changed the system voltage to 24v. Perhaps that's a safety mechanism, and certainly not a big deal by any means, but I thought it would just automatically switch. Other than that and perhaps wishing the Bluetooth range was a bit further without having to buy an external antennae, I love the 60A. It's so well built, it just works, and at a price that should embarrass the likes of Victron (yeah, 31 bucks for the temp sensor *wire* Victron, really???). Great job HQST :)
@junkerzn7312
@junkerzn7312 5 месяцев назад
It probably works the same as the Victron where it is auto upon initial commissioning, but after that if you change the battery voltage you have to adjust the charger controller manually. Definitely a safety feature because you don't want a charge controller mistaking a dead battery with a lower-voltage battery.
@chrisreynolds6331
@chrisreynolds6331 11 месяцев назад
I bought a bench power supply last week it's ideal for testing MPPT controllers
@joshuafreeman9792
@joshuafreeman9792 Год назад
I have the 20 and 40 pluses one of the srn looking one the had before love them all
@rvertv
@rvertv Год назад
what a great price. good review and video
@HOBOTECH
@HOBOTECH Год назад
Thanks!
@HimitsuYama
@HimitsuYama Год назад
My Victron equipment has always been rock solid, though at a price. It would be great if another vendor provided equipment of similar quality at a reduced price. I’ll keep my eye on HQST.
@retrozmachine1189
@retrozmachine1189 Год назад
If you are looking at these things look into helios (the OEM that makes it) M4860N
@superphotog
@superphotog 8 месяцев назад
@@retrozmachine1189 - Low temp cut out on Helios? Went to their website and no mention of low temp protection.
@stevecarlisle3323
@stevecarlisle3323 6 месяцев назад
Okay, there are many companies selling these re branded Helios units, so what's your point ?​@@retrozmachine1189
@UPdan
@UPdan Год назад
Loving my HQST. Better look at the vtoman Prospeed 3000. Wow !!! Loving that display panel.
@ChrisDeLuca
@ChrisDeLuca Год назад
I figure the reason the smaller one becomes the master is because. It cannot handle as much input nor can it run a 48 V system. Therefore they will default to the least common. Denominator which would be the smaller of the two units
@Avman3369
@Avman3369 Год назад
My thoughts also. It would also work for the 60A controller to be the primary if when it was installed in parallel with the 20/40A units and be limited to 12/24V settings automatically.
@vaughnsvideos
@vaughnsvideos Год назад
Hey Tom. Sorry I dropped Patreon support, after two years I was just not in the market for a SoGen and was really here for the campervan stuff and I am about to retire and your channel is doing well, so I just had to tighten the belt a little. Still think you are great though and wish you the best of luck and I like to see things like this mixed in. Maybe things will line up again in the future and I can toss more love your way.
@kevinroberts781
@kevinroberts781 Год назад
The smaller one needs to be the master because its more limited. You don't want the 60 amp model telling the 20 amp model to do something it can't do.
@michaelball7440
@michaelball7440 17 дней назад
I have two 60a units in parallel mode and I see no difference in operation either with or without this mode. What exactly is supposed to occur in parallel. And I have, of course, two solar panel banks, 800w and 760w. Starting either controller first, making that the master, makes no difference either...
@2hotscottpro
@2hotscottpro 14 дней назад
Cable seems to be a joke? I have 2 60a controllers also going to 1 bat bank.Cable paring didn’t make so I only need to see 1 controller on app.Weird
@2hotscottpro
@2hotscottpro 11 дней назад
LiTime says cable was only used in development.We don’t need one.😊
@JeffRoush
@JeffRoush 6 месяцев назад
I wish I had seen your video first! I just bought the Li Time version of this ( I was buying their batteries so I figured I'd stay in their ecosystem ). It looks to be the exact same device with a different paint job, but they must have modified the firmware. Mine does not have the setting to tun on/off the low temp cutoff and, even though it came with the temperature probe, their version of the manual specifically says to NOT use the temperature probe with LiFePO4 batteries. Odd that it came with the probe but has no way to turn the function on/off. Anyway, thanks for the great video!
@2hotscottpro
@2hotscottpro 6 месяцев назад
Wonder what’s up with that.But you have 5 year warranty vs just one.
@NotMeeither
@NotMeeither Год назад
I wish that this video had came out before.I ordered a new charge controller!
@rickreid5896
@rickreid5896 8 месяцев назад
Don't worry, you saved yourself some money.
@jchal5180
@jchal5180 Год назад
Really like this
@stevecarlisle3323
@stevecarlisle3323 7 месяцев назад
Thanks for your helpfull videos. I have poor solar in the winter months in the north. I also see you have been bench testing charge controllers with lab constant power supply. Is it possible for me to switch between solar source, or wind power ?
@MikeJordanUnCamplicated
@MikeJordanUnCamplicated Год назад
Love my HQST panels. I've got an RV full of the Blue stuff. But looking for a DC-DC charger and I don't want to spend Blue stuff money this time around. I have my eye on that other HQST related unmentionable brand. But HQST needs to jump on the DC-DC charger band wagon
@brucewoytassek9299
@brucewoytassek9299 11 месяцев назад
Thanks for doing what you do! I am educating myself on Solar and you are a good part of my education! I currently have 2 190 watt panels in parallel , 2 wet 12VDC 100 AH batteries in parallel and a 30 amp PWM charge controller. Thinking of upgrading to MPPT controller, smart shunt and eventually Lithium batteries. Would the 60 AMP controller work on my 30 amp system so I can upgrade as finances are ready? (Travel trailer) -- PS: I think you should offer a "HOBO Certificate" for watchers! Thanks again! bw in ND.
@alaingoyette7103
@alaingoyette7103 20 дней назад
Thanks for this great informative video. I had not heard of that product before. I have looked at their documentation and could not find the minimum PV input voltage to get it running. Do you have this information? 🤔😊
@2626sylver2626
@2626sylver2626 Год назад
Sir you won yourself another subscriber 🙂🙂
@MarkSDCA
@MarkSDCA 10 месяцев назад
Thanks for all the great videos. Very helpful. Can I charge my 300Ah battery bank with two seperate MPPT charge controllers, one mounted on top of the trailer and the other is a portable panel used when the trailer is in the shade and I need to remote the panel. What do you think?
@JaiManny
@JaiManny 11 месяцев назад
Just bought one... Simply based on this video.
@BobBob-il2ku
@BobBob-il2ku 11 месяцев назад
Can you change the tempature cutoff from 0 Celsius to 5 Celsius for example?
@21degrees
@21degrees Год назад
Great Vid! Thanx
@cardinhamkilligrew9712
@cardinhamkilligrew9712 Год назад
I am saving for the 20 AMP now...
@nikolatesla5553
@nikolatesla5553 8 месяцев назад
I have been extra concerned about the low temperature shutoff. My Lithium battery bank is my most expensive part of my system. At Sunrise in the Northwest thr temperature is often below or hovering around freezing. I would hate to have to replace $1500 of batteries of because of freezing temperatures. Can a minute of charging cause damage? I would feel more comfortable if i could set a temperature shutoff a little above freezing. But I admit I might be just paranoid. Any opinions?
@advancedxdirective
@advancedxdirective Год назад
Do you think the 20 amp version would be good for the 3rd input of the leoch?
@AQUASCAN1
@AQUASCAN1 10 месяцев назад
On the parallel cable do you know if all 6 pins being used? Thanks in advance.
@ericklein5097
@ericklein5097 11 месяцев назад
That minute delay might be put in the firmware on purpose to prevent any false readings or something that would cause the sensor to be exposed to a really cold gust of air for a brief period of time
@traphouse5941
@traphouse5941 Год назад
Hi i got a question i got a 12v deep cycle marine battery and i would like to know if i can charge it at around 12amps or it would be better 6amps? Thanks
@mrdemascal
@mrdemascal 2 месяца назад
If you have various watts/amps strings of panels running to the controller will ot make the efficiency of the bigger system less or just add the watts from each system together ? I have 2 400w strings paralleled into our current 60A unit. Want to add 400 to 600 more watts with a 40 amp controller. From your experience will having 600watts on one controller and 800 on the other decrease the input from the 800 unit? Hope that wording makes sense?
@kevinmills5293
@kevinmills5293 4 месяца назад
Hi, I’m looking at this as an alternative to the Victron SCC and I’ve studied the user manual but I can’t find anything about the absorb time. Is it user configurable and if not, how is the absorb time determined?
@astrobob9432
@astrobob9432 Год назад
Hey, Hobo! when will you have a review on the Bluetti AC180?
@jimhager8583
@jimhager8583 4 месяца назад
Thank you Hobo, know I know
@user-rx6up8wr2z
@user-rx6up8wr2z 11 месяцев назад
Please reply. Can the 60amp controller charge my 12v li batt at 60 amps and still give extra 10+ amps of power off the direct load terminal. Maybe a stupid question but...
@mikesgarage394
@mikesgarage394 Год назад
Hmm, that explains why the screen pictures in the manule are identical to thos in the wanderer manual.
@SolarSun-wp6oh
@SolarSun-wp6oh 11 месяцев назад
I would like you to test out sunthysis charge controller there is only one other RU-vidr that has tested and it is half the price but is it as good don't know
@lisakroner-reddy4282
@lisakroner-reddy4282 10 месяцев назад
I bought the 40 amp model for use with my 200ah LiFePo4 Powerurus battery, using a gopower 200 watt solar panel. Unfortunately, my battery was pretty low when I installed the Mppt Solar charge controller, and it seems to be taking quite a while to fully charge the battery using only solar. What do you recommend I customize the MPPT settings to? Or, should I just leave the default settings? TIA
@2hotscottpro
@2hotscottpro 5 месяцев назад
Get 2 more panels.A 600 watt panel is recommended for my 230ah bat.
@ccox7072
@ccox7072 5 месяцев назад
This may be a dumb question, but can I over panel these controllers like I can on my Bluetti EB240?
@davidcarrico3385
@davidcarrico3385 Год назад
A couple of questions on the 20mpg model. Could this be used to charge something like a Bluetti eb70s? If so, since it supports 12 and 24 volt charging, what would it auto detect from the eb70s’ 8mm port? Also, and I’m not sure what the right term is, but what’s the charge voltage for a 24v lfp battery? I believe it’s in the 14s for a 12 v, does that mean for a 24v that it would be in the 28s or 29s (possibly exceeding the eb70s’ 28v max)? I doubt it would be financially advantageous to do this just to get a few extra w out of my panels, but I have been on a quest of how to squeak out the most efficient charging given the eb70s’ limits, without purchasing their panels, which are fairly expensive. I currently own two 120w panels and I think their VoC is something like 21.7v ish (can’t remember the exact spec off the top of my head), so I hit the 8amp limit on the eb70s before hitting 200w of input.
@HOBOTECH
@HOBOTECH Год назад
Solar generators already have built in solar controllers so you can't use this on those.
@johnsemrau6412
@johnsemrau6412 Месяц назад
So would I be safe running a 1000 watts solar with some shade on 400 watts?
@DroneManMurphy
@DroneManMurphy 5 месяцев назад
How do we change the temperature from Celsius to Fahrenheit?
@maverickmikekauai3515
@maverickmikekauai3515 6 месяцев назад
Aloha, is it possible to set user defined specifications for non standard batteries? (like repurposed Nissan Leaf EV batteries) Thanks for the great job I really enjoy your videos.
@HOBOTECH
@HOBOTECH 6 месяцев назад
Yep
@joeclark9042
@joeclark9042 8 месяцев назад
Very good video buddy I really enjoyed this I got to ask you a question will this do flood batteries also please let me know if so I'm going to buy me a couple of these things thank you very much
@HOBOTECH
@HOBOTECH 8 месяцев назад
Yes
@DC_tronicFPV
@DC_tronicFPV 6 месяцев назад
Just went through the settings on my 40amp and does not have on/off for low temp. Any advice?
@superphotog
@superphotog 8 месяцев назад
I wanted to buy the 60amp one but $$ ($290CDN) and current and 'immediate future' solar plans for an emergencies and RVing will not be requiring the 60amp model so I ordered the 40amp. #1 consideration was built in low temp cut off so I can use the refurbished non-heated mini lifepo4's from Power Queen and Li Time. The Li-Time was partially Hobotech's recommendation with an assist from John Daniel. There has been talk in the solar power forums as to the relationship between HQST and Renogy. I would say joined at the hip. My order acknowledgement for the HQST controller was from Renogy. Photos in the forums of products received from all HQST products orders have some pieces arrive in Renogy packaging. I would guess part of the strategy is to have a lower cost outlet as one pays royally for Renogy. The other, much to the chagrin of their Canadian customers, is how bad Renogy's customer service reputation is. They have a BBB rating of 1.15. Products are respected, relied on and 'top shelf,' customer service is abysmal.
@phillipzx3754
@phillipzx3754 5 месяцев назад
When I looked up the HQST headquarters address using Google Earth, it seems this is a brand of Renogy? And since the new Li Time controllers look the same as the HQST models, is Li Time also a Renogy brand? Not that I have an issue with it. Just trying to connect the manufacturing dots.
@drgranger2
@drgranger2 Год назад
Good information. Thank you
@ThunderChicken1
@ThunderChicken1 8 месяцев назад
Something else that's not in the manual. How do you set the WH rating on the 2440N
@2hotscottpro
@2hotscottpro 6 месяцев назад
Go the advanced settings, change your float voltage to 13.6 and change your Boost voltage to not more than 13.9v. Once you set your boost voltage above 13.9, the error happens. If you set your boost voltage below 13.9, you wont have the issue again. However that means you wont be able to fully harness the power of your solar panels. Lifepo4 battery ideally use 14.6v as boost voltage
@junkerzn7312
@junkerzn7312 5 месяцев назад
The boost voltage generally has to be 14.2V when using generic 4s LiFePO4 batteries, otherwise their internal balancers won't ever trigger. 14.6V is 3.65V/cell which is typically the BMS disconnect voltage... you generally don't want to charge the batteries to that point. The BMS low and high voltage disconnects are always supposed to be the last line of defense, not the first line of defense and the high voltage disconnect can cause the charge controllers to over-volt the battery bus when it trips. The float should always be between 13.4V and 13.5V ( 3.35V/cell to 3.375V/cell). Any lower and you lose capacity when dropping down to the float, any higher and the float will overcharge the battery if held long enough. -Matt
@2hotscottpro
@2hotscottpro 5 месяцев назад
I copied that from someone else that had issue from the comments.
@4428314
@4428314 8 месяцев назад
Good Lord, you are a fountain of information! Thank you for your expl
@BobBob-il2ku
@BobBob-il2ku 11 месяцев назад
Epever AN series charge controllers updated there firmware & now have the low temp Charge protection too but you have to enable it via a pc with there usb cable
@superphotog
@superphotog 8 месяцев назад
And they generally cost more feature for feature.
@davidpatrick1813
@davidpatrick1813 Год назад
V V for victory for var var varsity. 🙂 Nice review
@johnshaw359
@johnshaw359 Год назад
Seems logical that the smaller unit takes control. They switch as a safety feature when you change critical parameters.
@VanlifeWithus-lr2et
@VanlifeWithus-lr2et 8 месяцев назад
Can these units be connected by Bluetooth to an external android screen/tablet without Internet?
@readypetequalmers7360
@readypetequalmers7360 Год назад
is there any security on the bluetooth like being able to disable it? I always get annoyed how someone can walk by and takes control of devices. I wouldn't want to keep an eye on my settings make sure they are at safe levels.
@rickreid5896
@rickreid5896 8 месяцев назад
You need to be really close to use the Bluetooth function. If it works.
@d.l.sstudio8922
@d.l.sstudio8922 3 месяца назад
Have you been using the “LI” mode for lifepo4 batteries? Or are you using a custom setting for them? The “LI” setting will keep your battery at full voltage until the solar panels power output decreases from lack of sun. I thought keeping your batteries at “charging voltage” increased degradation of cells? Or is this a myth? Just trying to find the best charging setting for my Lifepo4 batteries. I’ve been using the “Victron” settings that are posted on will prowes forum. 28.4v boost, 27.2v float Would you use the this custom setting or the standard “LI” setting on the HQST controller?
@user-rp1vu1gk5u
@user-rp1vu1gk5u Год назад
sorry im new to this, i bought a couple lion energy 12v 100 watt pannels and a dr. prepare 1280 battery to run a fridge in the garage. will this 20amp or 40amp charge controller plus an ac inverter work for my needs?
@HOBOTECH
@HOBOTECH Год назад
Yep
@junkerzn7312
@junkerzn7312 5 месяцев назад
It actually looks quite decent, very similar to Victron charge controllers though I dunno if they have the level of device integration that Victron has. Particularly if one has a shunt in the system. Victron has a number of very flexible relay control features. You can always parallel charge controllers, no integration required for that. But Victron's can be ganged together in a virtual bluetooth network so they will communicate with each other without any cabling. Now one area where the Victron really falls short is the auxiliary Load output. Only some of Victron's smaller charge controllers have it, and more importantly the Victron load output can't handle startup surges... for example, if you are trying to power a small inverter or grid-tie microinverter from the load output, or any device with input capacitors, the Victron will fall flat and not be able to enable the output (it thinks it is shorted and gives up). So I wonder how the HQST controller deals with startup surges like that, and also whether the HQST can handle the full 20A on a 48V system, as well as a bit of power factor, without blowing up its load switch (which is usually a FET). I also wonder what kind of solar "voltage" headroom is required above the battery voltage to be able to get the full output. It is fairly typical for very high efficiency charge controllers to be buck-only (rather than buck-boost). This means that the solar operating voltage has to be a number of volts above the battery voltage to be able to push full amps into the battery. Usually 5-10V or so. It looks on the face of it that the HQST is passively heat-sinked, as is the Victron, which is a big plus. Any charge controller that requires a fan is a charge controller that you should never buy. Its too bad that HQST only offers 48V support with their 60A charge controller. And for a premium too, $220. That is not competitive with Victron's SmartSolar 100/20 which is also able to handle 48V battery systems and is only $90. At 48V (well, 51.2V nominal), 20A is usually plenty for a small system... over 1000W and generally one is already ganging a few strings together to get it so you generally want a separate MPPT input for any further expansion. A lot of the 60A capability of the HQST is going to be wasted due to the limited voltage range the HQST support. Victron has a more balanced, useful offering in this regard. -Matt
@jasonpotts6490
@jasonpotts6490 Год назад
This sounds like a great alternative to a Victron. I had decided I was stuck with Victron since I was going to use batteries without low-temp protection and was instead planning on using the $900 Victron to shut charging down if the temp drops. Now you asked an important question for me regarding whether or not the better app is worth the extra money. Since I've used neither, could you or someone please help me understand what I'd lose if I didn't go with Victron? I'd probably still go with a Multiplus inverter because of its low idle power consumption, but would I really miss out on anything if I can't use the mppt part of the victron amp? Thanks to anyone who can enlighten me on this. I'd rather just buy two 40A HQST units for ~$225 than spend ~$900 on a Victron if I don't really gain anything other than some bells/whistles and possibly longevity. P.S. I always stick around to the end of your videos just to see Odin's commands! Funny AF
@svenshanah
@svenshanah 6 месяцев назад
Sorry no one answered you..I don't smart phone, so I'll need to use my kids' to even see "any" app.. Funny Fact; I was about to get the Victron..I was so set on it that I had this video in Que way back when it was new, and ignored this video because due to issues with cheaper stuff, I was done playin'.. Well, as life goes I got side tracked on other projects and I'm just now getting around to playin' with my solar stuff, and I decided to hear this video out, only to hear this basically is a Victron - so I just went from buying one Victron at a time to three of these 60 amps (I'm going 48v on this next system, and my bugout location gets in the single digits), and I'll be way better off for it. So what'd ya get? I'm also curious about the Multiplus for the same reason. And of COURSE ya stay for Odin..I mean duuh..🤷‍♂😂
@junkerzn7312
@junkerzn7312 5 месяцев назад
If you have the Victron shunt or any other Victron device with a temperature sensor capability in the Victron virtual bluetooth network, all the charge controllers can use it and they will all shutdown and restart in tandem using that one sensor. Any serious system is going to want to have a shunt anyway, and generally you don't want the charge controllers to each have their own temp sensor because you might have multiple charge controllers in the system and that would become a bit of a mess. Even just having a master with a temp sensor is not ideal... the shunt will be a lot closer to the battery than the charge controllers, typically. The Victron 100/20 is a much cheaper device than the 60A HQST. Half the cost. Less than half the cost. And while it is only 20A, at 51.2V that is still 1000W of solar. You would be hard-pressed to find a solar topology that actually produces 60A @ 51.2V with the HQST due to the HQST's voltage limit. But if your solar topology does that for you, then perhaps the HQST is the way to go. In most cases though the panel groups are far enough apart that you want them on separate MPPTs and not all ganged onto one MPPT. -Matt
@stevedias7323
@stevedias7323 Год назад
Hey professor, and community. I'm waiting for my 60 and 40 amp controllers to arrive. Do you think these can be monitored by a Victron Energy GX Touch 50 screen through bluetooth, usb or some super secret MacGyver techniques?
@closetcleaner
@closetcleaner Год назад
No, but you can ask HQST
@TheCornucopiaProject-bd5jk
@TheCornucopiaProject-bd5jk Год назад
I would certainly go for the 60amp model. I think you should have a charge controller that can supply enough energy for a 12v 100ah battery. Speaking of battery cables. I use 4/0 cable to and from the battery (via busbar) as well as the inverter and I use 4awg cable for pretty much everything else. Welding cable of course.
@davidgunther8428
@davidgunther8428 Год назад
At 60A charge rate, a 100Ah battery is pretty small, and going to often leave the solar panel output under utilized. 🤔
@TheCornucopiaProject-bd5jk
@TheCornucopiaProject-bd5jk Год назад
@@davidgunther8428 depends on the size of the solar array. In a Van or RV 300-1200 watt of solar is common, with most people being between 300-600 watt. That 60amp charge controller handles 900 watt of solar.
@davidgunther8428
@davidgunther8428 Год назад
@@TheCornucopiaProject-bd5jk at 600W the charge time for 12.8V 100Ah battery would be about 2.5 hours. The rest of the day the solar would barely be utilized. At 900W in, I think the battery would be in constant current charging for less than an hour, then start to taper. This is why I thought 100Ah is small for a 60A charger.
@TheCornucopiaProject-bd5jk
@TheCornucopiaProject-bd5jk Год назад
@@davidgunther8428 ok, I re-read my original statement. I wasn’t clear. I think the 20 and 40amp controllers are undersized even for a 100ah battery. While the 20amp 300watt controller can charge a battery in a day, I rather have the “option” to add solar panels to either charge my battery faster and/or get a full charge even during bad weather conditions. I like to have expansion capabilities even if I don’t exercise them. So I’d always get the larger model
@gregyohngy
@gregyohngy Год назад
I can use the 48V version with any solar panels to power my Ebike! I missed it, but can you limit the Amps being delivered?
@rickreid5896
@rickreid5896 8 месяцев назад
No and it overheats when it gets even close to the 60a mark
@EccentricOffGrid
@EccentricOffGrid 4 месяца назад
I wish victron had these colors
@jheighten7568
@jheighten7568 8 месяцев назад
I just bought Yuma 200w flexible panel. Would I be able to use the 60A. ?
@HOBOTECH
@HOBOTECH 8 месяцев назад
Yep
@WhatNowChris
@WhatNowChris Год назад
You should do a complete video on controllers and LifePo4 batteries. I purchased a ampere time 200ah LiPo4 after your review of the battery. I have a renogy rover 40amp charge controller, when I throw it on Li settings, it flashes over charge. I’m not sure why. I contacted ampere time, they told me to put in user settings, and the battery charges fine now, only problem is once the sun goes down and there’s a small load on it, the volts drop to 13.1 volts. According to the book that’s 50-60% charged(something like that). Is that normal? Maybe a bad battery? Please help! Thank you.
@HOBOTECH
@HOBOTECH Год назад
That's normal.
@EfficientRVer
@EfficientRVer Год назад
Voltage barely changes vs state of charge on LiFePO4, so calculating its SOC from voltage is a bad idea. Especially under load. But if you're looking to use low voltage as a cutoff, you can track Wh usage to get SOC, then see what voltage that gives you under the load you expect to be using when you later want the low voltage cutoff to activate.
@lakorai2
@lakorai2 Год назад
Would be all over this if it supported dc to dc charging as well
@Nemo_IRL
@Nemo_IRL Год назад
It's interesting that you can parallel 2 of these together but I'm wondering what are the advantages of doing so, since you can run multiple charge controllers on one battery bank anyway.
@Golfreak
@Golfreak 11 месяцев назад
That's what I posted. I have 2 different mppts on 1 battery bank and I have zero problem.
@junkerzn7312
@junkerzn7312 5 месяцев назад
Multiple charge controllers will read different battery voltages on the battery bus due to a combination of differences in the voltage sensor and differences in the currents each charge controller is pushing. Generally speaking the comms are just there so the charge controllers change battery charging states in tandem. e.g. Bulk -> Absorb, Absorb -> Float, Float -> Bulk. It is not absolutely necessary that it happen, it's just less of an eyesore when they are synchronized. The network will choose one charge controller's voltage reading and all the units will use that one source. In a Victron system, for example, this is automatic when the charge controllers are on the same Bluetooth VNET. In addition, the Victron app will blare warnings at you if any of the charge controllers have different parameter settings.
@marsrover001
@marsrover001 Год назад
Other than the settings sharing I don't particularly see a use for "parallel" options. You could always hook 2 mppt's to the same battery with no issues without the parallel cable. Settings only take 10 minutes to program and you never touch them again. I just really don't understand why that's a feature.
@hqstsolar2630
@hqstsolar2630 Год назад
Two commonly used controllers can be connected to charge a single battery bank system simultaneously. However, our MPPT controllers offer several advantages with their parallel charging function: 1. Information exchange and charging settings synchronization between the two controllers are possible. 2. Inconsistencies in setting parameters between the two controllers are avoided. When you adjust the settings of the primary controller through the app, all changes will be automatically synchronized to the secondary controller, reducing the need for manual adjustments. 3. Enhanced charging efficiency is ensured. Controllers with different specifications may have varying charging accuracies. When two controllers with significant differences in power and precision are used in parallel to charge a single battery bank system, there is a risk of one controller misinterpreting the charging parameter information, which can impact charging efficiency. 4. Improved safety during charging. If the primary controller detects any abnormalities in the system, it can shut off charging on its own and simultaneously instruct the secondary controller to do the same. This protective measure enhances the overall safety of the battery system. Hope it helps clear up your confusion.
@DeliberateNRandom
@DeliberateNRandom Год назад
Even Will Prowse has recommended HQST in the past. I bought one solar panel from them and a couple Renogy ones more recently.
@davidhovis2299
@davidhovis2299 3 месяца назад
Just stumbled on this after dragging my feet on not wanting to spend victron money but needing 100+ amps of charging with room to expand. I see these can be paralleled, but curious if three can be used together?
@HOBOTECH
@HOBOTECH 3 месяца назад
Yes
@adarondax
@adarondax Год назад
Can you clear something up about Master/Slave assignment? Is it possible to make the 60A a master and the 20A a slave and get that arrangement to stick? Asking for myself and a friend. Obvious workaround is to just get two 60A's. The reason is that we want the low-temp charging cutoff to be active on both controllers.
@HOBOTECH
@HOBOTECH Год назад
As I said in the review it is random.
@MrBumbles2
@MrBumbles2 9 месяцев назад
hqst, redodo, li time all have these out. some the bluetooth works some don't lol. my renogy died looking at one of these
@superphotog
@superphotog 8 месяцев назад
Don't think Redodo or Li Time have low temp cutoff. I saw the insides of the Redodo and the HQST and they were different circuit boards.
@barongugelsurch1145
@barongugelsurch1145 7 месяцев назад
Can a pwm safely charge a lifepo4 battery?
@deanmills5106
@deanmills5106 Год назад
What so you think about their 190 amp solar panel. Have you had any experience with them.
@junkerzn7312
@junkerzn7312 5 месяцев назад
You mean 190W. Yes, its a fine panel. 24.3VOC, 20.3V operating, 9.36A operating, 10.15A short circuit. Pretty typical electrical specs for a 12V panel. HQST panels are generally high quality.
@chadrogers3161
@chadrogers3161 Год назад
Looking at the 40 amp model now....if my panels are under the 100 volts voc but they produce about 900 watts out of the 4 panels will this blow the controller??
@HOBOTECH
@HOBOTECH Год назад
The controller will simply limit to 40A output.
@chadrogers3161
@chadrogers3161 Год назад
@@HOBOTECH thanks sir!
@tslucam
@tslucam Год назад
Great video. I ordered the 60A. Question...I have some left over 455 watt panels from another project. The VOC on the panels is 49.35. What would be the suggested layout to get the most out of the controller? I was thinking 2 parallel strings of 3 panels with a 48v battery bank. Am I headed own the right path?
@powerranger9160
@powerranger9160 Год назад
The 60A controller will accept 150Vdc max input, so 3 @ 49.3Voc panels in series will work. Yes, you would put a second series string of three additional panels in parallel with the your first set of three. Good luck in your project.
@davidgunther8428
@davidgunther8428 Год назад
49.3V ×3 = 149V. Very close to the max. If you have a cold day and fully charged batteries the Voc could go above 150V. I'd put only 2 panels in series with those voltages.
@tslucam
@tslucam Год назад
@@davidgunther8428 Thank you for that info. I live in Phoenix Arizona. We do get a handful of days a year were the temps drop into the 30's but typically our average overnight temps stay in the 40's. Would you still have that concern in those conditions?
@davidgunther8428
@davidgunther8428 Год назад
@@tslucam if there's no current draw on the panels because the battery is fully charged, the panels will be at Voc. Voc increases with lower temperature. I think at sunrise the panel temperature could be low, and Voc could be a few volts above the 49.3 rating. Say it goes to 52V each, would 156V total kill the charge controller? I'm not sure. I'd say it's borderline, but wouldn't recommend it.
@tslucam
@tslucam Год назад
@@davidgunther8428 Thank you very much. The advice is much appreciated.
@EasyyokeFilms
@EasyyokeFilms 11 месяцев назад
Bought this after watching your review because I always trust products that you recommend. However I have been running into a problem with my Litime Mini 12V 100ah battery(the exact type of battery you used for demonstration on this video). There is an E02 error flash that comes up on the HQST charge controller everytime my battery has fully charged to 100% and it wouldnt stop until I disconnect my solar panel. More like my battery BMS switches off my battery once the battery is full and that signals an over voltage error to the controller. I thought this happens only to cheap PWM controller. Do you have any workaround with this? The error light would start to flash once the battery is full, volts would jump upwards on the controller and charging would stop. The controller would basically reset itself and try to start charging again. And then few seconds later, E02 error comes up again. This happens only when the battery is full. While this is not suppose to be a serious issue(I could simply hust disconnect my panel when the battery is full) but If I am not around and I leave my battery to charge, and it gets full before I come back, the controller is supposed to stop receiving charge from my PV not flash error code and reset itself and then try to continue charging an already full battery again. I searched online and saw that many people have thesame issue with the controller. Do you have any workaround to this please?
@2hotscottpro
@2hotscottpro 6 месяцев назад
Wow I missed this info when ordering.What’s the company say about it ?
@EasyyokeFilms
@EasyyokeFilms 6 месяцев назад
@@2hotscottpro Go the advanced settings, change your float voltage to 13.6 and change your Boost voltage to not more than 13.9v. Once you set your boost voltage above 13.9, the error happens. If you set your boost voltage below 13.9, you wont have the issue again. However that means you wont be able to fully harness the power of your solar panels. Lifepo4 battery ideally use 14.6v as boost voltage
@2hotscottpro
@2hotscottpro 4 месяца назад
Ok I watched it today.Bat full charged and error Eo1 showed up over discharged bat ? But there was still watts going in to bat though? Weird.
Далее
Portable 20A MPPT with Bluetooth
20:26
Просмотров 13 тыс.
BougeRV Sunflow 60A Solar Charge Controller Review
17:09
Сумерки сасага🧛
11:41
Просмотров 498 тыс.
LiTime 60Amp MPPT
12:25
Просмотров 13 тыс.
Flexible Solar Panels One Year Later Should you Buy?
20:38
Solar Charge Controller Showdown & Buyers Guide
19:41
HQST 60A MPPT 12/24/36/48v solar charge controller
3:52
Sungoldpower 60A MPPT Solar Charge Controller
15:24
Просмотров 2,8 тыс.
How to Size a Solar Charge Controller
8:44
Просмотров 62 тыс.