HVAC 118 Charging with 4 port Manifold manual valve low loss fittings 

Love2HVAC with Ty Branaman
Подписаться 50 тыс.
Просмотров 19 тыс.
50% 1

A continuation form 116 and 117 now we add a 4 port manifold and demonstrate even more methods for charging. come back for 119 tomorrow, charging with probes

Опубликовано:

 

15 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@vert5
@vert5 4 дня назад
I was super lucky to pick up a Yellow Jacket 4v Titan manifold from a retiring HVAC technician for 60$ this weekend. Have my vac pump coming tonight, prolly order a micron gauge this week so I can start getting ready for my garage minisplit installation. Love learning about trade skills, at the same time I know how important it is to know my limits.
@kyferez1
@kyferez1 Месяц назад
Thank you for explaining this with such detail! Very helpful for learning!
@mariadelia7945
@mariadelia7945 2 года назад
Outstanding instructor and 410a refrigerant charging! Won’t find a better explanation. Take the time to write down these sequence of events to follow! Thank you Ty Banaman, you 'da man on this subject.
@Ric_James
@Ric_James 2 года назад
Can’t wait to watch this when I get home from work. I always feel like if getting hands on experience because these videos are so good!
@abv8822
@abv8822 2 года назад
Can't agree more amazing content
@ida587
@ida587 2 года назад
Wow, really great explanation!! You are a natural teacher, the highest compliment I think I can provide. So well done and thank you
@love2hvac
@love2hvac 2 года назад
Thank you
@jimj7571
@jimj7571 Год назад
Right on! There are so many other wrong videos on this topic.
@borisp9499
@borisp9499 2 года назад
I use a different approach to purging lines without losing any refrigerant to the atmosphere. I do it as follows. Connect the low pressure, high pressure and refrigerant tank hoses just like you did, but keep all the ball valves at the end of the hoses closed. Then attached a vaccum pump to the vacuum pump connection. Now open all the 4 ports on the manifold gauge. Remember, there will be no flow of refrigerant since all the ball valves at the end of each hose are still closed. Now run your vacuum pump. This way you just vacuumed out all the hoses as well as the manifold gauge. Now close off all the ports on the manifold gauge, starting with vacuum. From here on you can open the refrigerant and low pressure ball valves and charge as you describe. The basic difference your approach and the one I suggest is that instead of using the refrigerant to purge the hoses I simply vacuum them out.
@love2hvac
@love2hvac 2 года назад
Yes that would be great. #1 you expect a service tech to pull out a vacuum pump at every service call? #2 what do you do with the vapor refrigerant left in the hoses when your done?
@tomasznowak5433
@tomasznowak5433 3 месяца назад
@@love2hvac Hi, what if I close the high pressure valve while system is running and then the compressor sucks in all the refrigerant from the hoses? After that I open the hp valve again. Is it a god solution?
@rpsmith
@rpsmith 2 года назад
Great video! Thanks!
@clementmoves9704
@clementmoves9704 2 года назад
Awesome explanation!
@deanmartin1966
@deanmartin1966 2 года назад
Great video Ty
@sandeepsvasir
@sandeepsvasir 2 года назад
Thanks
@realestateservicessaleshea99
@realestateservicessaleshea99 2 года назад
🥃🍺😎👍🏻
@shine-cg9uf
@shine-cg9uf 2 года назад
👍👍🍎🇺🇸💪🐕
@North49Radio
@North49Radio 2 года назад
Hi, so is the high side port after the condenser? Which port would you use if there is one after the compressor and one after the condenser?
@love2hvac
@love2hvac 2 года назад
The high side is simply the hi pressure side. In this example I used the liquid line after the condenser. It is the most commonly used and supplied high side port for most manufactures. We can use the discharge line that is also high pressure on some equipment. It's located between the compressor and the condenser. In that car we don't have to worry about the liquid, however the higher temperature of that line can burn your hand and wear out the rubber gaskets in your hose connections. Also on split system units it's usually not accessible so your more likely to see that used on package units.
@North49Radio
@North49Radio 2 года назад
@@love2hvac Thank you, so I understand this, is this the preferred method or does it matter other than the heat/gasket damage as mentioned above? Great videos. You should develop a RC troubleshooting training game like simutech did for electrical. Would be awesome.
@jayare6872
@jayare6872 2 года назад
I'm Lost
@mariadelia7945
@mariadelia7945 2 года назад
Keep reviewing this video over and over. If you buy or are using 4 Way/Port Manifold Valve Pressure Gauges to Charge an Air Conditioner, this Video is EXCELLENT instruction on how to UNDERSTAND HOW to use it. Do your DUE DELIGENCE in taking the time to practice what He showing us.
Далее
HVAC148 Vacuum p15 example 3 The 4 port manifold gauge
15:31
HVAC 119 Charging with Wireless Probes
12:54
Просмотров 42 тыс.
Understanding 3 4 Way Gauges
12:39
Просмотров 13 тыс.
HVAC 041 Hoses and low loss fittings
12:43
Просмотров 42 тыс.
HVAC 123 Recovery Tanks part 1
13:25
Просмотров 45 тыс.
HVAC 109 Example, charging a low system
11:59
Просмотров 21 тыс.
This HVAC Press Tool Hack Will Blow Your Mind!
16:09
Locked Compressors
20:13
Просмотров 111 тыс.