Тёмный

HVAC: Bad valves and some quality duct work 

HVAC in SC
Подписаться 23 тыс.
Просмотров 14 тыс.
50% 1

Опубликовано:

 

25 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@HVACShopTalk
@HVACShopTalk 12 лет назад
A couple gems right there Brad. Stick a fork in that compressor! 9lbs overcharge, I mean damn that is crazy!
@HVACShopTalk
@HVACShopTalk 12 лет назад
no worries- thanks for turning me on to trutech. my second order is on its way!
@HVACinSC
@HVACinSC 12 лет назад
Thanks John! I should be getting my warranty SMAN back next week. I can't wait! Feels like I went back in time with these old gauges! lol!
@HVACinSC
@HVACinSC 12 лет назад
Thanks Brett! Yeah, I was shocked when I weighed the recovery tank on that one!
@1960tpk
@1960tpk 5 лет назад
Quicker to just check amps on compressor
@HVACinSC
@HVACinSC 5 лет назад
Might as well say, Not checking parts is faster.... 🙄😏
@HVACShopTalk
@HVACShopTalk 12 лет назад
It said in the description that it was.
@hvactecster79
@hvactecster79 12 лет назад
Great video and good job ob the compressor call Brad. Way to verify it before giving up on it. 9 lbs. overcharge is ridiculous. Take care,Brett
@AnchorSnake
@AnchorSnake 7 лет назад
Ran into the same thing today for the first time, had me scratching my chin for a minute. Remembered Eddie L's video, tried to pump it down. No Joy. Nice Video.
@1010tesla
@1010tesla 12 лет назад
great video on the compressor. have you changed it out yet?
@johnisraelhvac2019
@johnisraelhvac2019 12 лет назад
Hey Brad Great Video brother. Ya Buddy that compressor is done for great find. Gotta love that duct work that is just horriable i see crap just like it here all the time What did you do with your Smans Great video take care
@SombraLocs
@SombraLocs 10 лет назад
In his description he has a symptom if you have less than a 3:1 compression ratio, I thought that the compression ratio should be kept as low as possible to increase efficiency and to extend life.
@HVACShopTalk
@HVACShopTalk 12 лет назад
Ha. I got Testo 550 the first time and now I am getting a Fieldpiece STA2 and a Fieldpiece Mini wetbulb/drybulb meter. When I saw your EER video I already had it in my mind that I must have the stuff to do that. I had a wetbulb meter, but I wanted something that could be "in duct". I was thinking that I would love to see the BTUH/EER difference on some of these units where, for example, after new TXV's. As the new TXV holds superheat at 10(or whatever) instead of 25 how much would eer improve
@HVACinSC
@HVACinSC 12 лет назад
Thank you! If you check out my SMAN failure video you can see what happend. Something broke under the face of the gauges and was leaking refrigerant. Thanks for watching!
@EddieLeverich
@EddieLeverich 12 лет назад
So do I get a hint to what you have coming ? lol
@EddieLeverich
@EddieLeverich 12 лет назад
lol I guess that I should be reading the descriptions before asking questions
@HVACinSC
@HVACinSC 12 лет назад
Thanks for watching man!
@TheKingsofcombat
@TheKingsofcombat 12 лет назад
I remember that now.
@TheKingsofcombat
@TheKingsofcombat 12 лет назад
great video. what did ya do to your smans that they had to be warrantied?
@quimshtgclg
@quimshtgclg 11 лет назад
Great video , Haven't checked very many scrolls ,can they be checked this as well?
@EddieLeverich
@EddieLeverich 12 лет назад
was it overcharged?
@KentuckyDipper24
@KentuckyDipper24 11 лет назад
Wonder where the guy that did that duct work got his certification
@TandNServices
@TandNServices 11 лет назад
Loved the ductwork!!!
@MegaRadio90
@MegaRadio90 12 лет назад
Bad valves ain't cool big waste of electricity right there!! OMG tarring that return like that oh the humanity job security I guess, but makes yah sick to see that stuff. Great video!!!! :)
@SombraLocs
@SombraLocs 10 лет назад
@ 1:58 where did you disconnect the condenser fan motor from?
@MrWestsideWillie
@MrWestsideWillie 11 лет назад
Learned something new. Thanks man.
@tedcookheatingservice111
@tedcookheatingservice111 9 лет назад
Great video !! Where in SC ? I am in Greenville.
@OcRefrig
@OcRefrig 7 лет назад
Ductboard strikes again. Hate that stuff ! Make a Metal Plenum for those people. it's Return air . metal plenum. insulate on outside with cut wrap and spray glue and your done ! nice clean no fibreglass air !
@HVACinSC
@HVACinSC 7 лет назад
OcRefrigeration,Hvac & Electrical. Man, this is an old one. 2012 video. lol Thanks for watching
@MegaRadio90
@MegaRadio90 12 лет назад
"Seeing" lol typo!! :)
@cbacca85
@cbacca85 12 лет назад
Quality duct. Someone's never heard of a flat slip or a drive key
Далее
Diagnosing Poor Compression
13:53
Просмотров 79 тыс.
Гравировка на iPhone, iPad и Apple Watch
00:40
Compression Ratio
39:40
Просмотров 26 тыс.
How to repair aluminum evap coils
15:05
Просмотров 23 тыс.
Compressor - Troubleshooting Weak or Bad Valves
5:54
Forced-air Furnaces: The What, Why, and How
22:05
Просмотров 1,3 млн
Failed Compressors - Don't JUST REPLACE IT
24:59
Просмотров 66 тыс.
Reversing Valve Replacement does not end well
12:33
Просмотров 86 тыс.