HVAC Service | System Running Non Stop 

John Israel HVAC
Подписаться 42 тыс.
Просмотров 79 тыс.
50% 1

Welcome to Israelhvac's RU-vid Channel. On this channel i bring you along on HVAC Service calls, HVAC Maintenance and pretty much anything else HVAC related. Enjoy and thanks for watching.

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 192   
@joshuapoche5137
@joshuapoche5137 6 лет назад
This is what other youtubers wont show. This is real world situations that you run into all the time. Other youtubers are scared of getting bashed so they only show the good calls. Great job man
@chrissimmons706
@chrissimmons706 6 лет назад
Joshua Poche I agree with you Joshua. This was. Real world call. Great job John.
@RandoWisLuL
@RandoWisLuL 2 года назад
antidiyhvac sure doesnt mind lol
@tjk1512
@tjk1512 6 лет назад
turns the camera off to "remove some gas" haha
@gmw1964z
@gmw1964z 6 лет назад
Do you think he "recovered" it?
@bricksquad9552
@bricksquad9552 6 лет назад
Hey, I mean.. de minimis release though lmao...
@derrickenbuenosaires
@derrickenbuenosaires 6 лет назад
here in argentina you can blow off how much gas you want haha
@bricksquad9552
@bricksquad9552 6 лет назад
Illegally I'm sure.
@bobcranberries5853
@bobcranberries5853 6 лет назад
Clorox Bleach de maximas release
@kevinchestnut9056
@kevinchestnut9056 6 лет назад
I used to service these units all the time when I worked for Sears. These old beasts have a double row coil in them, and dirt or (in our area) cotton from a cottonwood tree will get between the two condenser coils. When you have high head pressure, pull the top and take out the screws that hold the plate that ties the two coils together. Separate the inner and outer coil, and clean the Hell out of them. If you do that, I guarantee your head pressure will drop and your superheat numbers will look a lot better. Those old units are war horses and will run for a long time it they're properly maintained. Having said that, this unit hasn't been properly maintained, so it will probably shoot craps on a really hot and humid Friday afternoon.
@kenthomas4668
@kenthomas4668 5 лет назад
I agree if you have high head and liquid temps like that it's dirty!
@jwwasher
@jwwasher 5 лет назад
Ken Thomas I’d have loved to see the discharge temp
@TheProAer
@TheProAer 5 лет назад
They don't make them like that anymore. Alot of the newer ones from what I've noticed last maybe 15 years. Especially Gibson's!
@lazyjack8081
@lazyjack8081 6 лет назад
1:39 That unit has a double horseshoe condesnser. Head preasure is out of range because the inner coil is dirty. Pull the top. Remove thr. screws on right side to give you some space between the two coils. Rinse with water. Foaming coil cleaner will not cut it. 45 years experince. I remember when that design was new.
@TheProAer
@TheProAer 5 лет назад
None of the new ones are built that way anymore.
@samernam
@samernam 6 лет назад
Customer says I can’t come inside. I say you can’t have AC then. I need to see the whole system. Not just part of it. Don’t trust me then I don’t service you. Nuff said.
@tptm100
@tptm100 3 года назад
I would start with a filter.
@coolmandude1000
@coolmandude1000 6 лет назад
I installed many of those Whirpool / Kenmore models back in mid 80's and still have many working great. Hell my grandparents had one just like that installed in 1980 a year before I started in the HVAC trade and a father and son team replaced a old Amonia AC unit that my grandparents had installed in the late 50's or early 60's. The installer punctured a Amonia line and it almost killed him and put him in the hospital for 5 days I was told. My grandparents were the only people in thier neighbor who had central AC and a color TV and a inground pool and had the party house for all the neighborhood to hang back in the day. RE Michel Co sold that Whirpool model and switched to TEMPSTAR in the late 80's.Damn I feel old now lol.Gonna hit 93 degrees in Baltimore MD tomorrow $$$
@erikcable1755
@erikcable1755 6 лет назад
me and mosby installed AC in new homes back in the early 80's complete install for $850.00 per ton
@Heavy_metal_rulez
@Heavy_metal_rulez 6 лет назад
Good call on this one John. Prime example of when it's time for replacement. And as far as analog gauges go, I use them every day along with a pipe clamp and my fieldpiece meter
@quadguy1470
@quadguy1470 6 лет назад
You were right about people crying that you should fix the thing but what these people fail to realize is that the time involved in repairing this unit is all a huge waste if next week the condenser fan goes then a week later the contactor goes, the following week the capacitor shits out on you. I've had it happen here in northeast Ohio with multiple heating failures on an old gas furnace where the customer said "why didn't you just suggest replacing it the first time it failed?" I told him because my crystal ball was broken and I had no way of knowing his board would go out 3 weeks after the blower motor went out. If you sink an excessive amount of money into old equipment you can have an unhappy customer as well, it's a roll of the dice.
@joeshearer1247
@joeshearer1247 6 лет назад
With a liquid line that hot it's a coil clean issue or fan issue.
@johnisraelhvac2019
@johnisraelhvac2019 6 лет назад
The condenser coil is in bad condition
@jfmc2581
@jfmc2581 6 лет назад
This guy really doesn't care that he don't know what he's doing... I'm amazed he makes videos he's not very good at his job.
@Clamjammer
@Clamjammer 6 лет назад
Or a restriction
@brianellsworth4767
@brianellsworth4767 6 лет назад
A restriction doesn't give you a hot liquid line. That means the subcooling is low. Dirty condenser
@robertfitzgerald5371
@robertfitzgerald5371 6 лет назад
Joe Shearer i bet the cond was filthy, and no i dont think this guy is amazing but yes that drier was clogged and that would give you the symptoms he had. I just bet there is more than just a clogged drier. Like you said i bet the cond is filthy. With that said. The issue that brought that unit down was the clogged drier. He was right on this one.
@speckulator7516
@speckulator7516 5 лет назад
If the management company was paying the power bill they would have changed it 20 years ago. I had a unit like that acting similar and pulled out probably in the early 80’s. I put in the most efficient condenser I could find, an 11 seer Ruud with the double coils and fans. Knocked $100 off the power bill the first month and it was July. The old unit was about a 7 seer. The tenant is going to love the new unit. It will pay for itself in a year but it’s different pockets.
@ritab9973
@ritab9973 6 лет назад
its a dirty coil clean the coil the dryer was not restricted. Restricted dryers do not go up in temp
@uxwbill
@uxwbill 6 лет назад
At risk of expressing an unpopular viewpoint...I disagree. Throughout your discussion about this air conditioner, the only sin it seems to have committed is that of being old. And while it's not all that efficient or pretty to look at any more, it seemed to be running fine otherwise. I would have fixed it "the right way" by changing the filter/dryer rather than draining away some of the charge to limp it along. The customer might not have any idea what any part of an air conditioner is or does, but they would have noticed things working like they used to, rather than the merely acceptable performance they are getting now. And I think that would foster a tremendous amount of goodwill. People remember more than anything else how they were treated and when it did lay down and die, they'll call the guy who treated them right to put that new system in. Maybe I'm totally wrong here. I certainly don't know the unit's service history, and if it is a recurring problem (as you hinted in the video), that really does change things. It's also not my intention to cause a problem.
@earthling94
@earthling94 6 лет назад
Can’t tell people how to spend their money. Give em options, let them weigh it. Either way, it’s still gonna cost them.
@johnisraelhvac2019
@johnisraelhvac2019 6 лет назад
We gave them 2 options. Repair or Replace.
@zachwood5683
@zachwood5683 6 лет назад
In @Israelhvac defense I did had similar problem last year and suggested to replace or fix, after fixing multiple problems in one day the customer called back 2 days later ready to replace. Ultimately it was the landlord replacing and when the customer was giving them fire about the out of pocket they stepped up to replace.
@JamesLee-oe7mt
@JamesLee-oe7mt 6 лет назад
Just wondering...if it was the dryer wouldn't the side after the restriction be at very low pressure and then considerably cooler? I mean a piston or txv is just an intentional restriction right? Just trying to figure it out.....
@uxwbill
@uxwbill 6 лет назад
HVACR Atlanta: I'm not calling anyone's experience into question here. :-) I can't be in front of that unit to pick up on what it's trying to tell me, so all I had to go on was the indicated temperature differential around that filter/dryer and the extremely high head pressure. Were I there, I'd certainly have had a look around to see what the unit and its surroundings were saying.
@1971omi
@1971omi 3 года назад
Thanks John. The problem is not fter drier. Dirty inner condenser. Those units have 2 coils. Regardless. People would rather using old system that draws crazy amps flushing their money than new system and saving big in bills. But I'm just a Tech not sales pitch guy.
@scottboomshakalaka9593
@scottboomshakalaka9593 6 лет назад
I have to ask, is it a common thing when the resident won’t let you in?
@realvanman1
@realvanman1 6 лет назад
Seems like the condenser coil needs to be cleaned... If the dryer were completely clogged, the head pressure would drop off to that associated with ambient temperature. The suction would of course go to vacuum. There's nothing wrong with that dryer. Once you replace a HIGH QUALITY, LONG LASTING old piece of equipment with modern junk, it's all over for the customer. They'll never see a reasonable service life again. CLEAN THE COIL!
@TheGhettoLobster
@TheGhettoLobster 5 лет назад
Diagnosis may have been incorrect but the end solution should still be the same. The unit doesn't owe the customer anything and nothing lasts forever. Might as well get it over with as its probably going to crap out in the near future. Why wait till everything shits the bed before doing a preemptive change out?
@peterhodgkins6985
@peterhodgkins6985 5 лет назад
@@TheGhettoLobster - The age of the unit isn't a cash cow for the vendor either. What should have been done is to resolve the problem IF it can be resolved, rather than assuming an old piece of gear will not last much longer. If you wanna be a technician, then be technical. If you wanna read Tarot cards for hire, then that's a different business. ;) If a condenser cleaning dropped the liquid temperature, then the customer is getting maintenance and a problem is solved. If the cleaning doesn't solve it, then that's the time to suggest to the customer that the machine has reached the end of its useful service life.
@williamdorsey4744
@williamdorsey4744 6 лет назад
that unit probably has a two speed condenser fan and a switch in the condenser that went bad for low ambient operation. make sure fan is running high speed and clean the condenser coils. Technicians shouldn't be removing gas they should be recovering refrigerant.
@aidenp265
@aidenp265 5 лет назад
I also had 5-6 old whirlpools with the slanted coils and the baish finish these units are original and now only one is left and is still in business along with a carrier round one and a Coleman Evcon and, 2 General Electric units. The point is they still work and are probably older than this unit by 5 years. Though, the other 4 whirlpools were hauled out. And when I return to my country club again I hope they are still their.
@nathanhurst5155
@nathanhurst5155 4 года назад
I know this an old video but a very good video showing how the real world really is. That machine has served its time. Time for new. That being said I woulda gave em options to keep it goin IF they didn’t have the means to replace it. It for sure coulda used a good bath and I betcha that would got the head down some. Also remember that those old machines did run a higher head than some newer 22 systems. Good vid!!
@mikewatson5602
@mikewatson5602 5 лет назад
You could add another dimension to your videos by explaining why “ that’s not good”. Why helps us connect the dots.
@realisticjman
@realisticjman 6 лет назад
I agree that the unit is not worth it but your problem is high head need to clean the condensor coil and check the motor blade pitch or what ever basically need to cool the condensor
@fromanabe8639
@fromanabe8639 5 лет назад
Thirty years old? That's just getting broken in. Mine is 40 years old and still works great! I installed it myself from a local company who offered DIY kits. The only thing I couldn't do was fabricate the plenum for the evaporator coil.
@pnajera3938
@pnajera3938 5 лет назад
Start off with cleaning condenser coil, then check the charge
@rtoweprojects9072
@rtoweprojects9072 5 лет назад
That unit was worth changing a filter drier by compared to the cost of whole new system. Now once the compressor an expensive part replacement goes then it's worth a new unit. I'm maintaining a unit like that and when I say maintaining I mean just checking it each year. The customer always ask about replacing it and I tell him as long as it's working and cooling I wouldn't touch it. This I didn't tell him is that a new one would not last as long this one has for 40 years.
@bababooey7576
@bababooey7576 6 лет назад
My keeprite is going to turn 35 in one month's time. It has never broken down, leaked, or even faltered once in the 20+ years we've owned this house. Runs so quietly and cools the house so easily. Even capacitors were original up until a few months ago. A co worker and I changed them one day after work. The original ones had oil on top and would probably have failed fairly soon. .it cost me nothing more than purchasing the capacitors. Having said all that, as much as I would hate to give this gem up, when it leaks or finally does shit the bed, it will be replaced post haste...why bother holding onto something that's past its useful life?
@johnboykin3128
@johnboykin3128 6 лет назад
I replaced 2 units this year, mainly cause they were R22 units and had leaks. The R22 phase out has cost me several thousand.
@bryanrifenburgh4020
@bryanrifenburgh4020 3 года назад
Love the videos - 3 years in, 1st year technician
@utubepro7742
@utubepro7742 6 лет назад
Good job 👍🏻 Love real life stuff John That unit isn’t even worth cleaning coil But I’m surprised you didn’t just to see the head drop Sometimes we are just janitors
@achdiagnostic7773
@achdiagnostic7773 6 лет назад
David Duda sometimes I will rinse the coil. If it is dirt and not corrosion you'll see the head climb right back up after the water dries. Time to let go of the past. Life expectancy in st tex for a unit on the coast is 5 to 10 years. Complaining about a 30 year unit. Ha.
@opsurf9198
@opsurf9198 3 года назад
We need more professionals like you out here in California. There robbing us blind!
@RealityRenovations
@RealityRenovations 6 лет назад
Do you think airflow for the condenser could have also been a factor? Dirty coil? Failing fan motor? Obviously the solution is to replace the unit... Just curious if the filter dryer was the sole cause of the high head pressure.
@achdiagnostic7773
@achdiagnostic7773 6 лет назад
Brad B on older units electrolysis occurs where the copper and aluminum are pressed together causing corrosion. Corrosion is an insulator that prevents the rejection of heat from the copper to the aluminum. No amount of cleaning reverses this process. In an older unit multiple factors are in play from varnish build up on the copper tubing to lower performance of the fan to dirt on the coil to a possible partially restricted drier etc. An old corroded teardrop coil is your biggest contributor. A new unit would cost a $100 dollars less a month to operate. Wonder how long it would take to pay itself off. Sometimes the savings on the electric bill actually make the payment. Call me crazy.
@joeydelmarsjr.646
@joeydelmarsjr.646 5 лет назад
r22 is expensive so and not worth just getting another drier and the cost to evac and recharge. maybe worth it if he would do a 407c conversion
@douro20
@douro20 4 года назад
Or R-448a/449a.
@JoeCdaYT
@JoeCdaYT 6 лет назад
That unit has seen better days. Time for R&R for it. To go and just repair what is wrong is one thing if it was still in great shape and the compressor was in excellent shape. That needs major repairs and the compressor was not sounding happy. Good call.
@HVACGUY
@HVACGUY 3 года назад
I enjoy your videos, because they’re real, the same crap I see everyday.
@marksaeger1083
@marksaeger1083 4 года назад
My Air conditioner is 40 years old and it leaks Freon but still works great. It’s a carrier. Would you recommend I fix it?
@arcticarrowhvacr
@arcticarrowhvacr 4 года назад
Yes, get the leak repaired and charge it to spec. Nothing made today will ever come near to such longetivity.
@Clamjammer
@Clamjammer 6 лет назад
This is the type of call I'd love to get. If the customer agrees to dump maybe...650$ish in repairs or love to try and get that thing running top notch again. These old Kenmore's are monsters. I wouldn't guarantee shit tho!hahah
@coolezum
@coolezum 5 лет назад
I installed some of those under Heil name back in the early eighties. I believe that model was called the Hermitage.
@MrMultitool
@MrMultitool 6 лет назад
Why not let the person paying the bill decide what they want to do? does Your new Klein bag have the molded bottom or just plastic feet?
@johnisraelhvac2019
@johnisraelhvac2019 6 лет назад
TP Services We gave them 2 options. Repair or Replace.
@mwatkins2464
@mwatkins2464 6 лет назад
TheACKid you are a kid that knows very little about hvac. You might know just enough to cause problems. Stop telling seasoned techs they don’t know what they are doing. Are you fresh out of school?? You will learn more by listening and less running your mouth!!!👎🏻👎🏻
@monteiroair4259
@monteiroair4259 6 лет назад
I agree with you John. As others have stated. This was a real world call. It’s not black and white. I would have done the same thing. I’m sure the coil was beat as well. I have to feel good about any repair that I propose. That thing could lose that compressor or bust a leak any second. That compressor has been running hard with high head for how long ??? In my opinion you and your company made the right call. No disrespect to anyone that would have changed the dryer. But it’s 30 years old , enough is enough.
@caru3257
@caru3257 6 лет назад
monteiro air. What's the labor on it?
@speckulator7516
@speckulator7516 5 лет назад
I think is older than 30 years.
@kanemanification
@kanemanification 2 года назад
Got question ac unit outside keeps running even though the thermostat is off
@TedCookHVAC
@TedCookHVAC 6 лет назад
I agree with the final outcome of this video.... MAYBE cleaning the outside coil and or spending 2 hours with a fin comb and changing the dryer and spitting into the wind would have made sense to some of the so called techs out there.... but I would have rather moved on and suggested the customer do the same. It was time to draw the line... PAST time.
@mwatkins2464
@mwatkins2464 6 лет назад
TheACKid yea then the unit goes out a few weeks later and you look like a fool. I have done this on old units before after someone else had condemned it and yes the customer was happy till it had to be replaced within a month. That was way back in early 90’s when I was just starting out. This guy did everything right and I’m here to tell you a total cleaning new drier and anything else that pops up while doing all this is not cheap for a unit thats on its way out. You live and learn
@tombonini7393
@tombonini7393 6 лет назад
What makes you think that the unit is going to fail in a few weeks?
@JJ-Toreddie
@JJ-Toreddie 5 лет назад
Agreed. Time to scrap and replace
@blackishpariah
@blackishpariah 5 лет назад
@@tombonini7393 the fact that the compressor has ran over 400 head pressure, unit is almost 30 yrs old.
@Hvacmania
@Hvacmania 5 лет назад
Our unit stays on I turned the breaker off turned it back on the problem went away .but it's not turning off again . what do you think it is?
@coolezum
@coolezum 5 лет назад
Good idea would have been to check temp coming out of condenser discharge and if hot dirty cond coil and fan motor amps and rotation, just as a lesson for teaching. I agree with the call to replace though. Good call.
@SombraLocs
@SombraLocs 6 лет назад
So do you think it’s just a restricted drier or a bad compressor also?
@3beltwesty
@3beltwesty 6 лет назад
Running water from a hose on the outside coil will drop the head pressure and will give a clue of the betterment IF the outside coil was cleaned.
@benjamintimmins1656
@benjamintimmins1656 5 лет назад
Lol @ "that's the last thing I'm worried about on that POS"
@joerusso4645
@joerusso4645 6 лет назад
Another condenser unit with indoor flexible conduit. That was code in Louisiana?
@mcroley591
@mcroley591 2 года назад
There’s not a restriction. Wash the condenser coil.
@Randylazz
@Randylazz 6 лет назад
Real world stuff right there great video........= )
@Christopher-li7uc
@Christopher-li7uc 6 лет назад
If it would've pumped down ,its risky could've of stressed that compressor just enough ,and then you get blamed ! Definitely made the right choice in my opinion, I wouldn't have done much more
@tjbee1905
@tjbee1905 2 года назад
Split the coil and clean it, biggest mistake most make is not checking to see if the coil is a split coil!
@bobcranberries5853
@bobcranberries5853 6 лет назад
You can fix and repair anything! And then it’s still 30 years old! Let’s say you fix that problem for say $300 and then the compressor goes out on pumpdown now you have to tell the customer they need a new compressor too? Or let’s say you made the repair and it worked great and goes out in a few days... your right uxwbill the customer doesn’t know the difference between a three prong capacitor and a flux capacitor but he will know you charged him $300 dollars 2 days ago and now it’s broken again. If you take money for a repair the customer will expected to stay fixed for some time no matter what they say to the contrary. A good technician would expect that unit to die at any second no matter how many parts you throw at it. There will be no good will as you say, after you take there money and it still breaks down that same summer. Without a working flux capacitor on your time machine there’s not a damn thing you can do for that unit!
@blakwolf37
@blakwolf37 6 лет назад
everything has a life expectancy,30 years for a condenser is great when typically in the south they last 10-15 yrs and thats with proper maintenance besides the cost to recover ,replace dryer ,vacuum ,and recharge a 30yr old system,your asking for more problems ...i can only imagine what the 30yr old evaporator looks like.....good call
@gencii.c
@gencii.c 6 лет назад
I would replace that thing regardless of any issues.. giving the customer a price to repair the drier and recharge with freon etc, he agrees, you replace drier and blow the lines with nitrogen, clean her up and it ends up having issues again a little while later for whatever reason and then you look like the bad guy because to the customer, they “paid you to fix it”...so now get it workingg or its your fault.. better just replace and put that money towards a new system..
@THEtechknight
@THEtechknight 6 лет назад
speaking of old, My parents house has a 1993ish goodman unit that still running great surprisingly. Only thing that has ever had to be done was change a capacitor. It was grandmas house but my parents inherited when they passed. Furnace had to be changed out though. She was a senior citizen and got a new unit on a state run program which of course threw another goodman in there. But at least it works.
@caru3257
@caru3257 6 лет назад
THEtechknight A Goodman running?
@Jeepjones85
@Jeepjones85 6 лет назад
Great job, by the way Fieldpiece meters all the way. I’ve had Fluke, Uei and others. Fieldpeice is perfect for Hvac
@thomashuxley2959
@thomashuxley2959 6 лет назад
How do you know it wasn't overcharged due to a restricted piston. Data supports your decisions. No doubt that unit arrived with Columbus but, don't let your guard down.
@themechanic4222
@themechanic4222 6 лет назад
Please help! My ac running non stop inside and outside even I change new thermostat
@aidenp265
@aidenp265 6 лет назад
I disagree whirlpool heil Payne Rudd sears carrier York old unit brand's are all good, you just don't know what your talking about.
@1martinontherocks
@1martinontherocks 4 года назад
is it an acumulator or eliminator by the compressor?
@achdiagnostic7773
@achdiagnostic7773 6 лет назад
The condenser didn't look dirty enough to cause high head pressure. There were probably multiple things going on here. Partially restricted drier, coil corrosion where the aluminum fins mate to the copper, build up of contaminates inside the condenser tubing reducing heat transfer and possible valve problems because of how slow it went from 100 psi down to 75. Maybe not on that one though and no superheat to gauge it by. Bottom line a 30 year old unit has done it's time. Is fair to have the customer invest 300 or 400 dollars on a filter change out on a unit that will still only go down to 15 amps when a new one with 10 year parts will only run 8 to 9 amps. I didn't see a service valve which might have been added more to the cost. Choices yeah, but steering the customer to a new unit will actually pay for itself in the energy savings alone. Plus the new unit will have more capacity. It is amazing what you can show if you do a capacity test on a system.
@jenko701
@jenko701 2 года назад
Good video, great judgement. You can get married to a pos if you aren’t careful.
@clayevans3421
@clayevans3421 Год назад
I agree with the units that are about gone. If a system has a Freon leak, I’m not gonna spend extra time trying to perfect a recharge. To me, get them some cooling and let them know it may not last long. Hell, it’s leaking as you drive off. Wasted time in my opinion.
@chrisreid7907
@chrisreid7907 5 лет назад
Change the drier if the customer can’t afford a change out just yet. Just a thought
@edwardfoehring8827
@edwardfoehring8827 6 лет назад
Close hi psi side hit contactor pump to zero, change filter,drier
@fcdiaz1
@fcdiaz1 6 лет назад
right on man give the opp and it is up to owner nice job
@aircooledtx
@aircooledtx 6 лет назад
Drier blockage, and from here , looks like fan direction is backwards.
@johnisraelhvac2019
@johnisraelhvac2019 6 лет назад
Camera does that Mike
@DJT4363
@DJT4363 Год назад
i no why u should just replace the drier. if the home owner is like me I CANT AFFORD A NEW ONE
@jasongenovajr.776
@jasongenovajr.776 6 лет назад
I love all the people who comment who think they know it all over RU-vid comments.
@javiercardenas7588
@javiercardenas7588 4 года назад
That unit is to old way to old, just for the record. How's the outdoor coil I think that's a double coil machine and right in the middle of it sometimes they get really filthy. And I would recomend replacing the unit for something more efficient and quieter, as I said that unit is to old.
@richardvisco6370
@richardvisco6370 4 года назад
John you can't pump down that unit due to it has quick connects
@THEtechknight
@THEtechknight 6 лет назад
That was the exact same air conditioning unit that we had at our house when I was a kid, it had a 2 blade though. Ran great all the way up until we decided to put a heatpump in. Those were built like tanks. It was installed in the 70s, I think its a 70s unit.
@whiz3528
@whiz3528 Год назад
Stuck contactor, point are welded together.
@nike12000haha
@nike12000haha 4 года назад
Why would you do that cuz it saves the customer thousands if can easily swap dryer its not even hard to do that...
@dusterdude238
@dusterdude238 6 лет назад
sounds like a case of instant "Ka-ching for the repair service syndrome"
@rubencastillo2623
@rubencastillo2623 4 года назад
Consider plug condenser n orfice n dryer too iv ryn into tht itll vix it
@bkoz319
@bkoz319 5 лет назад
should have changed the drier. could last another 10 years
@Jeepjones85
@Jeepjones85 6 лет назад
I bet the cap tubs are stopped up, it ran good for a long time though!
@chuckrusso2131
@chuckrusso2131 6 лет назад
OK I hope you’re talking about the entire system that’s a r22 system they’ve stopped r22 manufacturing when was this video made tel me you not replacing just the condenser
@speckulator7516
@speckulator7516 5 лет назад
Chuck if they bought an air handler with an r410 rated coil all they have to do is change the TXV. It’s not his or the property managers first rodeo.
@doddgarger6806
@doddgarger6806 4 года назад
Amazing how many dollars people flush with these old units instead of paying the savings to a credit card used to buy a new system
@douro20
@douro20 4 года назад
Almost 400psi on an R22 system...I would really be worried...
@Clamjammer
@Clamjammer 6 лет назад
Just to see if I could get it back up to par
@renaissanceman4267
@renaissanceman4267 5 лет назад
I would have fixed it ....but thats me...good video
@johnwiggins1385
@johnwiggins1385 5 лет назад
You don't know what there finances looks like . They may not be financially able to replace the outside unit right now.
@markschommer7407
@markschommer7407 4 года назад
We had a Heil that looked like that. Sears sold them too.
@sidneycox8523
@sidneycox8523 6 лет назад
excellent john
@KEITHTB12345
@KEITHTB12345 6 лет назад
your right it was old get a new one.its time to upgrade
@crazydan2327
@crazydan2327 4 года назад
Blocked drier wont give u high head pressure clean ur coil
@larryames8831
@larryames8831 6 лет назад
o4:39 should have called the problem by now.. Maybe the tech is distracted with making the video or showing off his toys. The head is to high. Nothing wrong with drier. Some of those units have two speed condenser fans - was the fan turning at it's high speed? If so clean the conditioner. A restricted dryer liquid line dryer would cause a temperature drop not increase - that was misuse of his clamp on temp sensor. A lot of equipment gets changed because the tech get bonuses for selling equipment. This guy probably don't know any better than to post this homeowner focused video. A lot of trouble shooting errors in this video. For me the biggest error is the display of the tech's ignorant of the HVAC fundamentals and he so arrogance that he is doing the customer a favor.
@droodguy
@droodguy 6 лет назад
Did you see the unit? The thing is a disaster waiting to happen I wouldn't feel safe with it beside my house.
@larryames8831
@larryames8831 6 лет назад
everything you wrote makes no sense to me.
@erikcable1755
@erikcable1755 6 лет назад
so true here larry,,,a general PM service would be nice here,include a full report on the system after a coil clean and a look at the evap coil and cleaning of same...but wear a face mask inside the house so you can breath
@xavierstamps7765
@xavierstamps7765 5 лет назад
@@larryames8831 the pot calling the kettle black. I'm willing to bet everything that fan motor only has 1 speed. For the most part I agree he's really not the knowledgeable because I'm sure the unit is either dirty or possibly the motor spinning the wrong way
@purplegold714
@purplegold714 6 лет назад
Check the compression ratio on the compressor
@craigf2137
@craigf2137 6 лет назад
Missed that stop sign ha ha
@ebcrew
@ebcrew 6 лет назад
Not the drier, u got a coil not dissipating heat
@kurtnelson1775
@kurtnelson1775 6 лет назад
Smart decision
@Buildsbyallen
@Buildsbyallen 6 лет назад
i agree to replace the unit
@willthetrill4849
@willthetrill4849 6 лет назад
I would acquire that unit to restore it and add it to my collection
@kevinbennett2565
@kevinbennett2565 5 лет назад
@2:30 every customer that says it's on does this shit . They love wasting our time man hahaha
@samuelluke1659
@samuelluke1659 5 лет назад
Sometimes you just have to replace
@thomashuxley2959
@thomashuxley2959 6 лет назад
Boooo! Subcooling? Superheat? Airflow? Proper condenser motor/blade?
@applianceman6009
@applianceman6009 3 года назад
Tecumseh compressor
@bottitabaki3073
@bottitabaki3073 4 года назад
10:43 no stop sign 🛑 🤔
@vivalaluigi4423
@vivalaluigi4423 6 лет назад
How did u take out the gas out my friend
@erikcable1755
@erikcable1755 6 лет назад
you just let her blow into the air,,,
@arcticarrowhvacr
@arcticarrowhvacr 4 года назад
@@erikcable1755 Nope, that's called hurting our ozone layer. Most CFC's have global warming potential..
@myrkobalaban8571
@myrkobalaban8571 5 лет назад
Klein makes a 11n1. Check it out.
Далее
HVAC Service- No Cool Multiple Issues
19:54
Просмотров 188 тыс.
Typical Monday Running HVAC Calls!
29:52
Просмотров 7 тыс.
To mahh too🫰🍅 #abirzkitchen #tomato
01:00
Просмотров 1,2 млн
A/C Condensing Unit Runs Constantly T-stat is OFF
8:25
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 29 тыс.
RUUD AC CONDENSER KEEPS RUNNING
15:37
Просмотров 26 тыс.
Air Conditioning isn't free... but we're close.
25:45
All AC Parts and What They Do
33:24
Просмотров 1,7 млн
A/C Not Blowing Cold Air But Running
7:48
Просмотров 260 тыс.