Тёмный
No video :(

HVACR Service Call: Frozen Evaporator Coil Walk In Cooler (Frozen Evaporator Coil Diagnosis/Repair) 

Jumper man Tech
Подписаться 98 тыс.
Просмотров 18 тыс.
50% 1

HVACR Service Call: Frozen Evaporator Coil Walk In Cooler (Frozen Evaporator Coil Diagnosis/Repair) #HVAC #REFRIGERATION #JUMPERMANTECH
6 Causes of a Frozen Evaporator Coil
1. Lack of Airflow
As stated above, the evaporator coils absorb heat from the air. But if they don’t have enough heat to absorb, the condensation on the coils can freeze. Low airflow can be caused by dozens of problems within the AC system, such as a malfunctioning blower fan, dirty air filters, or even damaged ductwork.
2. Dirty Air Filter
A dirty air filter creates the same airflow problem mentioned above, preventing the evaporator coils from absorbing the necessary amount of heat from the air to function properly. Dirty air filters can also spread dirt and clog up other parts of your system, including the coils themselves.
3. Dirty Evaporator Coils
If your evaporator coils collect too much dirt or debris, the heat exchange process can become obstructed. Dirty coils will be unable to properly absorb the heat from the air, causing the condensation to become too cold and freeze.
4. Refrigerant Problems
Ironic though it may seem, having low refrigerant in your system can actually lead to frozen evaporator coils. Low refrigerant causes the system to overwork, which can lead to condensation on the coils freezing. AC units work on a closed system, meaning refrigerant doesn’t simply run out. Therefore, if you have low refrigerant, the problem is either a refrigerant leak in your system or an insufficient charge.
5. Outdoor Temperature Is Too Low
Similar to how the coils freeze when there is restricted airflow, they can also freeze if the temperature of the air your system is trying to cool is too low. Since the coils work by absorbing heat from the air, the lack of such heat can lead to condensation on the coils freezing over.
6. Clogged Drainpipe
Condensation forming on the evaporator coils is part of normal operation. However, if the drain pipe is clogged or otherwise hindered, too much condensation may develop on the coils, which can then freeze.
Call a Professional:
While there are several remedies you can perform on your own to alleviate frozen evaporator coils, you may not be aware of other issues going on with your AC unit. Trusting the job to a licensed professional not only gives you the peace of mind that the work is done correctly, but also you can be confident knowing that they will catch any surrounding issues as well.
How Preventative Maintenance Can Help:
While regular wear and tear is part of any AC unit’s lifespan, preventative maintenance is one of the most effective ways to ensure your system works properly. This includes changing your air filters regularly (every 60-90 days, as a general guide) and having a professional technician inspect and tune up your system - at least annually, but we recommend having this done before the summer and before the winter months each year.

Опубликовано:

 

10 фев 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 40   
@aquaticspecialities5382
@aquaticspecialities5382 Год назад
Love the vids bro. They motivate me everyday going to school and working my way towards that journeymen’s. Keep up the good work!
@JumpermanTech
@JumpermanTech Год назад
Thank you! I'm glad to hear that my videos motivate you. Stay tuned for new videos every week & good luck 🔧⚡️
@danielmurray2960
@danielmurray2960 9 месяцев назад
Aspiring refrigeration tech here. You’ve helped me in more ways then you can imagine brother 🔥
@JumpermanTech
@JumpermanTech 6 месяцев назад
I'm very glad to hear that my friend 🙏 Thank you! Stay tuned for new videos every week🔧⚡️
@colejc
@colejc Год назад
Enjoy the videos brother! one trick I learned thought id share for set screw tightening: is going 1turn tight then one turn back then one turn tight one turn back and a final turn tighter every time it'll get a little further and tighter Cheers!
@reefermadd.2204
@reefermadd.2204 6 месяцев назад
I’m wondering why they need to cool trash? Seems like a waste. But great troubleshooting. Keep it up.🤙
@JumpermanTech
@JumpermanTech 6 месяцев назад
From what I've seen, most larger type buildings that have restaurants as part of the building, all have air conditoned garbage disposal rooms. I believe it is code for New York City. Large infestations out here from waste. Thank you! Stay tuned for new videos every week🔧⚡️🤙
@nyanziabdallah944
@nyanziabdallah944 Год назад
I kept on bitting my teeth whenever u were fighting to put out the motor😂😂😂 thank you put no hole in the coil🙂. Once again thanks for the effort towards the trade🤝
@nicolerennie
@nicolerennie Год назад
great work JMT, thank you always! ⭐️💫🙌🏼
@JumpermanTech
@JumpermanTech Год назад
You're very welcome & thank you!! 🔧⚡️
@zekenzy6486
@zekenzy6486 Год назад
Great Video, Great Job. Nice Work. Thank you for sharing
@JumpermanTech
@JumpermanTech 6 месяцев назад
Thank you! Stay tuned for new videos every week🔧⚡️
@odeuslefrigoriste340
@odeuslefrigoriste340 Год назад
Full knowledge in your videos.Thanks
@chrisgotgame16
@chrisgotgame16 Год назад
Awesome Video JMT!
@JumpermanTech
@JumpermanTech 6 месяцев назад
Thank you! Stay tuned for new videos every week🔧⚡️
@migueldominguez4311
@migueldominguez4311 Год назад
Good job
@JumpermanTech
@JumpermanTech 6 месяцев назад
Thank you! Stay tuned for new videos every week🔧⚡️
@donkbracken
@donkbracken Год назад
That's a beautiful thing!
@JumpermanTech
@JumpermanTech 6 месяцев назад
Facts! Thanks for watching & stay tuned for new vids every week! 🔧⚡️🤙
@thesilentonevictor
@thesilentonevictor Год назад
Nice job jmt
@JumpermanTech
@JumpermanTech Год назад
Thank you!! 🔧⚡️
@gsxrsquid
@gsxrsquid 10 месяцев назад
Don't you love it when you get those easy ones? :D
@JumpermanTech
@JumpermanTech 6 месяцев назад
Definitely. Easy money! Stay tuned for new videos every week🔧⚡️
@gabrielmendoza9165
@gabrielmendoza9165 9 месяцев назад
At 1 minute into the video I can agree with you but I would not state the reason it iced up is because of the bad fan
@shaneevans8963
@shaneevans8963 Год назад
If your box temp was in the 50's and your suction pressure was like 40, (saturation like 5f) I would check that the valve was feeding properly. If the suction line wasn't freezing then super heat out of the evap is well over 30 degrees. Im not saying I would want a frozen suction line, but to me that would seem like a restriction somewhere. I would suspect another underlying issue with that system.
@itsprimetime9865
@itsprimetime9865 13 дней назад
if the box is 50 his pressure at start up should of been 70-80 for 404A his valve is starving
@robertdavenport9095
@robertdavenport9095 Год назад
Great job as always. Just wanted to thank you for another great video and inspiration. I got the exact some tools you have to do my job nut driver is amazing. Keep up the great work. I would love to do some service calls with you in the future.
@user-mr8uv6ue4h
@user-mr8uv6ue4h 5 месяцев назад
if the fans are working , and drain is not clogged what would be some of the issues?
@qhi1483
@qhi1483 Год назад
Love the Vids. Do you quote and bill the customer or do you quote and get paid immediately upon completion?
@danieljacquez2582
@danieljacquez2582 Год назад
10:09 lmao
@JumpermanTech
@JumpermanTech 6 месяцев назад
I just heard that 😂😂😂 Aye Miguel!! Haha & I know exactly who said that by hearing the voice. Thanks for watching! Stay tuned for new videos every week🔧⚡️
@lifeproject9182
@lifeproject9182 8 месяцев назад
Why are they cooling that storage for ?
@JumpermanTech
@JumpermanTech 6 месяцев назад
I believe it is code for New York City to have an air conditioned garbage disposal space. Thanks for watching! Stay tuned for new videos every week🔧⚡️
@thefreshride1510
@thefreshride1510 Год назад
How do we know what the pressures of a refrigerant?
@techti8792
@techti8792 Год назад
How's that 902 holding up man?
@JumpermanTech
@JumpermanTech Год назад
Honestly love that meter. I heard some people having issues with it but I haven't experienced that. Thanks for watching!
@frankspliff7037
@frankspliff7037 Год назад
Why ac a garbage room
@JumpermanTech
@JumpermanTech Год назад
Very normal out here in the city. All garbage rooms have AC year round. Thanks for watching!
@peepeepoopoo1399
@peepeepoopoo1399 Год назад
Probably to keep stuff from smelling
@rezag.o.m5680
@rezag.o.m5680 Год назад
Hello my friend, how many thousands of dollars do you earn per month?
Далее
WALK IN COOLER ICED UP
12:15
Просмотров 79 тыс.
HVAC Contractors Hate Me For Sharing This Secret
10:21
Просмотров 871 тыс.
Walk In Cooler(EMERGENCY WARM)
11:24
Просмотров 945
Walk-In Cooler Iced Up Now It Works Ok
9:39
Просмотров 10 тыс.
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
WALK IN FREEZER DEFROST ISSUE
34:29
Просмотров 103 тыс.
Basic walk in freezer wiring
11:16
Просмотров 66 тыс.
8 Reasons Why Your AC is Freezing Up
9:02
Просмотров 1,6 млн