Тёмный
No video :(

Installing A Simple Switch For DC OR DCC Model Train Control 

Scott Rails
Подписаться 4,7 тыс.
Просмотров 7 тыс.
50% 1

You don't need to rewire your entire layout when you upgrade to DCC. Today I show you how I did it. And, can you run a DC Loco and a DCC Loco on the same track at the same time?
Lets find out!
If you would like to support my channel, I have created an Amazon Wish list, and a Patreon Page.
Amazon: www.amazon.ca/...
Patreon: / scottrails
You can contact me directly at scottrodsgarage@gmail.com

Опубликовано:

 

28 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 32   
@pacificcoastminiatures
@pacificcoastminiatures 11 месяцев назад
Having fun is what model railroading is all about! Nice setup.
@YourLocalRailfan
@YourLocalRailfan 5 месяцев назад
I’m just getting into a larger layout and want a toggle switch (because switching and more trains at once) but only have dc, also so if a relative gets me dcc or something I can run it! Thanks for the help Scott
@theangelsmodellingandrailways
@theangelsmodellingandrailways 11 месяцев назад
Cool wee experiment Dave, its something I did not know about, pretty neat. I've pondered DCC but never made the move, yet. All the best. Brian
@Modelmaking123
@Modelmaking123 17 дней назад
Great video
@SD-uk2yo
@SD-uk2yo 3 месяца назад
This is exactly what I needed! Thank you so much for directing me to this link! 😎
@solargarage
@solargarage 11 месяцев назад
Looking awesome, love seeing it all working.
@mikeatpudhamjunction2323
@mikeatpudhamjunction2323 11 месяцев назад
Thanks for sharing. Stay safe.
@CockneyRooster
@CockneyRooster 7 месяцев назад
Such a good idea ...I didn't think of that switching between the 2 ...another good video helping me no end mate 👍
@ScottRails
@ScottRails 7 месяцев назад
I might add a couple of leds at either side of the switch. I still make the odd mistake putting a dc loco on dcc.
@CockneyRooster
@CockneyRooster 7 месяцев назад
@@ScottRails cheers mate
@Photoline1
@Photoline1 11 месяцев назад
Good demo. With great power comes great responsibil... eh, why not? Awhile ago, out of curiousity, I applied DC power to a tiny decorative AC bulb. The bulb got brighter and brighter as I turned the power up, until it blew, just as it should. Sometimes it's worth sacrificing a cheap item so you don't make the same mistake with a prize loco that cost a king's ransom.
@ScottRails
@ScottRails 11 месяцев назад
Exactly my philosophy, plus I'm a child and it's fun to blow things up.
@schadowolf
@schadowolf 6 месяцев назад
Nice!
@timothyjohnston4083
@timothyjohnston4083 11 месяцев назад
Did you read my mind ? :) I will be doing the exact same thing for my N-Rail compatible modules. However, this is so that I can change between two different DCC systems. N-Rail requires Digitrax compliance for shows; but I will be using MRC Prodigy at home. So I need to be able to select between which system sends power/signals to which of the 3 bus wires. In theory, I could use Digitrax on 1 track and MRC on another. Personally, I don't like the look of a toggle switch like the one you used. I find there is an increased chance of accidentally catching it on clothes. So I am planning to use DPDT on-off-on rocker switches instead -- if only Amazon would ship the correct ones. I've ordered 3 times from Amazon and 3 times they sent me DPDT on-off rocker switches ! That's 3 strikes ! So, while it probably will cost me more, I am heading to a local electrical/electronics supply store near my work to see if I can get the switches I want.
@ScottRails
@ScottRails 11 месяцев назад
I'm just using what works for now. One day I might make it pretty.
@mikebateman5524
@mikebateman5524 11 месяцев назад
I am confused. Firstly I see you install a changeover switch linking a DC controller and a DCC controller to the same track. The switch ensures that both DC and DCC cannot power the track at the same time. I get that. Next you run an engine using the DCC controller and show switching the engine’s lights etc. I get that. Then you select a second engine from a siding using DC to run it on the same track. How can that be??? Perhaps I have missed something or I just do not get what is happening - but I am very impressed. Please can you explain and put me back on the track - so to speak? Excellent presentation of your skills and what you are achieving I must say. Well done and thank you. Kind Regards. Mike - London, England.
@ScottRails
@ScottRails 11 месяцев назад
I see how that got confusing, sorry about that. The Bachman DCC controller allows you to run DC trains at the same time as DCC trains. But to make like simple I will only run ONE DC train at a time. That means I can treat the DC train as normal with forward and reverse, while controlling up to 8 DCC locos at the same time. That would be ridiculous on a single loop layout though. Even with two I manage to crash.
@canadianmodel4007KCS
@canadianmodel4007KCS 11 месяцев назад
Great work keep up with the good work I with my videos get likes and comments my railway videos are really good
@turtlehopper81
@turtlehopper81 5 месяцев назад
I'm trying to find that switch, actually I'm looking for a switch that would switch between 3 sources to my track. (DC controller, kato smart controller and z21 dcc controller) can you tell us the name of the switch or share the link?
@ScottRails
@ScottRails 5 месяцев назад
This is the switch I got, but it won't work for what you are planning: amzn.to/49fFfXG I think you need to look for a rotary selection switch. Maybe something like this: amzn.to/3PFu7MV
@turtlehopper81
@turtlehopper81 5 месяцев назад
@@ScottRails wow, thanks for the quick response
@jimorlando5700
@jimorlando5700 27 дней назад
I have 13 blocks on my 4X9 DC layout. I also have 2 DC cabs (A and B.) I’m using all Atlas block selectors. Any suggestions on how to set it up for DC and DCC operation? Thanks!
@monmixer
@monmixer 3 месяца назад
So you are soldering those center wires to the track and not using the terminal track? I assume I could still use the terminal / re railler track? Just put the proper connectors on the wire coming from the switch to the terminal track? That is my assumption is would rather not solder to the track. Correct?
@ScottRails
@ScottRails 3 месяца назад
You are correct. I have two wires (+/-) going round the underside of my entire track system. Every section of track has power feeders going to those two wires. Connecting those two switch centre wires to a track connector will do the same job, but with a bit less reliability.
@BriansModelTrains
@BriansModelTrains 10 месяцев назад
It is really a bad idea to run your DC powered locos on DCC power. The buzzing sound is your motor switching polarity at a really fast rate and will eventually burn out the coil winds of the motor. Running DCC locos is very possible on DC power but not the other way round.
@ScottRails
@ScottRails 10 месяцев назад
I totally agree, and if my locos were worth more than 30 dollars I wouldn't do it, hehehe. I don't mind upgrading the motors when the time comes.
@kiwitrains
@kiwitrains 9 месяцев назад
They are locos not trains 🇬🇧🇦🇺👍
@ScottRails
@ScottRails 9 месяцев назад
Oh no!, did the world end?
@kiwitrains
@kiwitrains 9 месяцев назад
@@ScottRails 👍
@ericb.davenport9762
@ericb.davenport9762 7 месяцев назад
How important is that?
@theplumber33
@theplumber33 11 месяцев назад
I do this. Great breakdown. 💯🫵✌️
@ScottRails
@ScottRails 11 месяцев назад
It's pretty simple when you get into it right.
Далее
New Dyna Skin is OP🥵🔥 | Brawl Stars
00:16
Просмотров 487 тыс.
Using DC and DCC On The Same Layout (333)
15:05
Просмотров 21 тыс.
Simplest Way To Convert Old DC Locos To DCC (267)
22:01
Wiring Your Model Railroad For DCC (335)
18:24
Просмотров 20 тыс.
How to use DC and DCC on your layout
17:38
Просмотров 102 тыс.
How to Master Track Laying on Modular Model Layouts
17:30
Fully Automate Your DCC Reverse Loops (197)
23:21
Просмотров 56 тыс.