Installing An Isolation Switch & EV Board 

Vartia Electrics
Подписаться 424
Просмотров 6 тыс.
50% 1

#sparkylife #electrician #vartiaelectrics
Welcome back! In today's video we are going to be installing a Wylex 100amp isolation switch and a separate EV distribution board.
00:00 - Introduction
00:56 - Installation Materials
02:20 - Installation
Thank You for watching.
Get your free EV Charger quote today:
Tel: 0208 144 1428
Web: www.vartia.co.uk
Instagram: ‪@VartiaElectrics‬
#sparkylife #electrician #vartiaelectrics

Опубликовано:

 

30 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 19   
@aryanelectrical
@aryanelectrical Год назад
Another great video Vartia electrics..... All the best 👍
@robertdunsmore
@robertdunsmore 2 месяца назад
Very well explained 👍
@abdoaiman
@abdoaiman Год назад
Thorough & clear explanation.. Thanks & good luck
@aaliyahvartia3586
@aaliyahvartia3586 Год назад
Wow nice video very detailed 😊
@Spark55278
@Spark55278 Год назад
Nice Video , Cheers👍
@grahamhill4453
@grahamhill4453 4 месяца назад
Great video but please get the cat off the piano. We're in the process of getting this sorted for an upcoming EV charge point install and this is the issue we're facing.
@Mainly_Electrical
@Mainly_Electrical Год назад
Butchered the EV board mate 😅,, good video
@VartiaElectrics
@VartiaElectrics Год назад
Hi Mainly Electrical, Ben said he tried to cut it out further with a cone cutter to fit the top of the gland in, obviously didn't go to plan 😂 He's given you a little shout out in the upcoming in this week's upcoming video! Vartia Electrics
@jameswright789
@jameswright789 Год назад
No SPD?
@VartiaElectrics
@VartiaElectrics Год назад
Hi James, Nicely spotted video incoming! Vartia Electrics
@chandreshvarsani2190
@chandreshvarsani2190 Год назад
Why the 6amp breaker?
@deang5622
@deang5622 Год назад
Possibly optional lighting circuit if you want outdoor lighting over the parking area of the car perhaps. I can't think of any other practical use of a 6 amp breaker.
@Chris_72
@Chris_72 11 месяцев назад
I believe when buying that BG Garage board it comes as standard with the 40A RCD and two MCBs. The two MCBs that come standard happen to be a 6A and a 32A. The 6A would be left spare as only an EV charger was fitted which will occupy the 32A.
@picklyplum
@picklyplum Год назад
You might find the DNO will only upgrade the fuse and tell you to get the customer's energy supplier to connect up your isolator as they're only allowed to go into the meter in emergencies as its not their equipment. DNO are responsible for the Cuttout, Supplier responsible for the incoming tails and meter itself. I know its annoying and you're trying to do things the "right" way but you might have some hurdles especially with the equipment being installed directly to the wall rather than on fire retardant material.
@VartiaElectrics
@VartiaElectrics Год назад
Hi Jarvik, Your correct the DNO refused to make the connection, the client's energy supplier is due to come out but at a charge of £162. Doing this the "right" way is causing a lot of hurdle jumping. You could also be right about installing straight onto the wall, however we would point out brick is fire retardant material. The EV board is metal and designed for outdoor use, so we are basically ready for them lol Thank you for your helpful comment. Vartia Electrics
@picklyplum
@picklyplum Год назад
@@VartiaElectrics that’s a ridiculous charge. Only encourages sparks to do things they’re not supposed to 😞 You can argue that about the brick, however I will almost guarantee the supplier will install the isolator on the meter board as this is standard practice. Nice one for trying to do things the proper way, sorry you and the customer have had issues!
@northeastcorals
@northeastcorals Год назад
​@@VartiaElectrics I'm baffled by this need for fire boards over non combustable type walls. I've seen a few videos now of people installing a load of large fire boards (for big solar instals) in a garage straight on top of a concrete block wall. In all my years as a fireman I can tell you I did not ever see a brick or concrete wall catch fire 😅
@VartiaElectrics
@VartiaElectrics 11 месяцев назад
​@@northeastcorals Good morning Gaz, Wow what a job, here's us worried about getting electric shocks lol. We agree with you bricks catching fire! but unfortunately as the saying goes "common sense isn't that common" and some work you see unfortunately backs that claim, so we can see why the regulations state this. More than likely it's put in place as a blanket statement to cover all situations. Kind regards Vartia Electrics
@northeastcorals
@northeastcorals 11 месяцев назад
​@@VartiaElectrics Agreed, even in the fireservice we would have to follow some ridiculous H&S rules, which were there for good reasons but sometimes common sense would tell you they were absolutely pointless for your particular situation but they had to be followed regardless (when we knew we were being watched or were on camera anyway 😆).
Далее
Is Your Property EV Ready?
13:19
Просмотров 8 тыс.
I Built a SECRET Soccer Field in My Room!
24:15
Просмотров 5 млн
Stray Kids <ATE> UNVEIL : TRACK "MOUNTAINS"
00:59
HAD TO STOP THE APPRENTICE - FIRST BOARD SWAP
15:55
Просмотров 5 тыс.
Upgrading Your Main Fuse
19:07
Просмотров 3,4 тыс.
100A SWITCH FUSE ISOLATOR INSTALL
8:45
Просмотров 42 тыс.
It's NOT SWA Cable Feeding Your House Cutout Fuse
7:07
METAL CLAD IP RATED CONSUMER UNIT
23:13
Просмотров 6 тыс.
Moving A Consumer Unit & Installing a Sub Main
20:08
Просмотров 51 тыс.
I Built a SECRET Soccer Field in My Room!
24:15
Просмотров 5 млн