Just One Too Many Problems. Well, One Major Problem With Their AC!  

HVAC GUY
Подписаться 64 тыс.
Просмотров 19 тыс.
50% 1

In this video I try to get them going, only to find out I can’t! #hvacguy #hvac #airconditioning #hvaclife #hvactrainingvideos #hvacservice #electrical #hvactechnician #hvactroubleshooting #compressor #airconditioner #furnace #heatpump #aireacondicionado #bombadecalor #calefacción #compresor #contactor #skilledtrades #bluecollarpride
Merch Store : hvac-guy-2.cre...
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

18 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 117   
@z06rcr
@z06rcr 2 месяца назад
Love that Valve core removal tool with sight glass… no more guessing!
@Dmcbigboy8687
@Dmcbigboy8687 2 месяца назад
I would try a hard start to see if that would brake loose compressor
@RobertTuck-vo8cw
@RobertTuck-vo8cw 2 месяца назад
I remember using a Little Annie to do the same thing.
@jimdavis6833
@jimdavis6833 Месяц назад
Hard start kits only work to avoid the inevitable for a while. It needs junked out and the whole unit replaced
@Dmcbigboy8687
@Dmcbigboy8687 Месяц назад
You right and that is the conversation I have with the owner as well.
@ftwbreeze
@ftwbreeze 2 месяца назад
Hello Curtis. I really enjoy listening to the birds. When you say Lovely, I know it's going to be bad news!
@RobertTuck-vo8cw
@RobertTuck-vo8cw 2 месяца назад
What about checking the inrush amps? It could have been a weak breaker that was tripping way too low.
@gussoidarg3956
@gussoidarg3956 2 месяца назад
Been there and done that, I've learned to manually push the contactor when I find an old system with traces of refrigerant leak to get an idea of the charge, that ussually gives up a bad compressor or capacitor too.
@user-hj5le6lo9w
@user-hj5le6lo9w 2 месяца назад
Totally agree. Woulda been nice to see the inrush too
@WSmith2024
@WSmith2024 2 месяца назад
Wire coming into the contactor box had insulation cut up.
@josepagan9236
@josepagan9236 2 месяца назад
Curtis you need try with use Megaohmeter Fluke 1587
@markbeiser
@markbeiser Месяц назад
No more often than we actually have a use for a megaohmeter, The Klein ET600 plenty, and 1/5 the cost of the Fluke.
@TomLawson05
@TomLawson05 2 месяца назад
Curtis great job troubleshooting very informative hope you get the repair or changeout thanks for the video
@HVACGUY
@HVACGUY 2 месяца назад
Thanks 👍
@jamminwrenches860
@jamminwrenches860 2 месяца назад
I would have replaced the 35 and tried a hard start. Seen some go for years after a pace maker.
@guytech7310
@guytech7310 2 месяца назад
May have been the compressor connector that had a short in it. Might have been useful to check the connector for a short.
@richardbartlett6932
@richardbartlett6932 2 месяца назад
he did as he disconnected the compressor and the fan ran. However he should have retested to make 100% sure it was the compressor.
@guytech7310
@guytech7310 2 месяца назад
@@richardbartlett6932 I think he disconnected the cable from the contactor when he ran the test, thus excluding the cable. Maybe I am mistaken.
@jthonn
@jthonn 2 месяца назад
Somehow, someway, that compressor is stuck. I guess from sitting. Dang shame after all the work you put into it beforehand. Good video, you can't win them all, I hope you get the replacement job.
@MrJujubean
@MrJujubean 2 месяца назад
He never took an Amp reading to see if it was over amping? As quickas that breaker was tripping it had dead short someplace it seems. I don't think it was LR
@jthonn
@jthonn 2 месяца назад
@@MrJujubean That is possible, that wiring was cracked up. I think that the unit sat so long the compressor was stuck. Now this rarely works and kind of barbaric, but I have taken a block of wood and a hammer and give the compressor a good wack, and sometimes it would start. Then I would install a hard start capacitor on it. That unit was old and it wasn't worth all the risk. If you got it going and then discover a leak, then you are really screwed. He made the right choice.
@ThePappas33
@ThePappas33 2 месяца назад
Maybe the breaker was shot blowing premature ..
@philiphusain3923
@philiphusain3923 2 месяца назад
Weak breaker ? May need hard start kit ?
@chrisnapier5626
@chrisnapier5626 2 месяца назад
Very good work,Curtis! I learn alot from your videos.
@panamacitybeachbum
@panamacitybeachbum 2 месяца назад
Nice view behind you on your opening statement.
@HVACGUY
@HVACGUY 2 месяца назад
Thanks!
@marvinsellers4457
@marvinsellers4457 2 месяца назад
So could it have been LRA? Aways enjoy watching your videos
@JHACbiz
@JHACbiz 2 месяца назад
That did seem to trip way too quick to be lock rotor...normally the compressor would attempt to start. But running the fan without the compressor proved there was no dead short upstream of the contactor so that means it's failing under load leading to either the compressor or the breaker/panel. I've seen it where the bus bar was burned up and the there was arcing under a decent load causing a dead short.
@hinspect
@hinspect 2 месяца назад
I very much enjoyed watching this late this afternoon. I would love to whack that compressor with a big rubber hammer or something! That looks just like the Rheem that was in a rental property. That one looked lazy, like trying to wake up a teenager 😂 Thanks a lot for the video. It made a great Sunday afternoon! 👍☺️
@c21meister
@c21meister 2 месяца назад
LRA inrush was blowing that breaker I’d say age killed it
@stevencossaboon3237
@stevencossaboon3237 2 месяца назад
Nice work Curtis.
@HVACGUY
@HVACGUY 2 месяца назад
Thanks!
@robalexander7348
@robalexander7348 2 месяца назад
Well Curtis, i hope you score the newchange over job 👍 Au
@alanbennett133
@alanbennett133 2 месяца назад
Curtis, you need to keep a fishing pole in that van man!!
@dmiestercommkitchentech3043
@dmiestercommkitchentech3043 2 месяца назад
Check capacitor by checking amps and volts if cap is good you will read both if volts and no amps cap is open if amps but no volts cap is shorted this will trip breaker it happens to dual capacitors more often and that is probably why the 5microfarad side of the dual cap was not being used a capacitor can read good if the only thing checked is the microfarad reading but still be shorted internally.
@Dougc3157
@Dougc3157 2 месяца назад
That unit looks like it had a hard life and it was totally neglected from the video. I guess the compressor was toast and the unit will have to be replaced. Great video.
@Howrider65
@Howrider65 2 месяца назад
Not all roosters attack lol. Some are very tame.
@jkmarshall3553
@jkmarshall3553 Месяц назад
All the ones I know do. LOL
@Hvac-dude
@Hvac-dude 2 месяца назад
Cant wait to see a changeout vidioe 😊😊
@reese8752
@reese8752 2 месяца назад
Did you notice the insulation was all cracked up on the line voltage wires?
@kens.3729
@kens.3729 2 месяца назад
Too Bad you could Not get this Old Unit Working but it was not for a lack of trying. 👍🙏
@Darth_Sidious_66
@Darth_Sidious_66 2 месяца назад
Any remodeling updates on your house, i.e., porch, underground pool, etc?
@peterking1134
@peterking1134 2 месяца назад
Did you check the circuit breaker?
@HVACGUY
@HVACGUY 2 месяца назад
Yes, I did. Nothing obvious
@RobertTuck-vo8cw
@RobertTuck-vo8cw 2 месяца назад
@@HVACGUY What about checking the inrush amps. It could have been a weak breaker that was tripping way too low.
@bobboscarato1313
@bobboscarato1313 2 месяца назад
@@RobertTuck-vo8cw I've seen breakers tripping leading to believe it was a bad compressor!
@user-xx7sf5ew8f
@user-xx7sf5ew8f 2 месяца назад
I have had many compressors trip the breaker when power is energized and not be able to get an ohm reading on the compressor
@stevea6722
@stevea6722 2 месяца назад
Lack of oil in the compressor, locked rotor maybe?
@dashcamandy2242
@dashcamandy2242 2 месяца назад
11:27 - What in the ABC's Wide World of Sports is that hackery?! ⚡
@HVACGUY
@HVACGUY 2 месяца назад
Lol😂
@zeldamoore8371
@zeldamoore8371 2 месяца назад
Good unit to use for training newbies. So many issues
@Hvacnc
@Hvacnc 2 месяца назад
What’s your go to leak detector rn ?
@SuperBigbuffy
@SuperBigbuffy 2 месяца назад
crankcase heater ?
@jameswood9764
@jameswood9764 Месяц назад
Need a couple of those magnetic parts trays?? Contractor wires broken insulation and corroded ?
@josereyes-go1pe
@josereyes-go1pe 2 месяца назад
I hope that when this person is finished he has cleaned the air conditioning when a job is done it is done complete and clean
@OnusBones
@OnusBones 2 месяца назад
It won't fit in your Veto bag, but would a 3-wood be the correct tool for a rooster, or would you be close enough to use a pitching wedge?
@naderiamurray6836
@naderiamurray6836 2 месяца назад
I noticed it’s a lot of older units down south compared to where I’m at in so cali
@amiatroll6347
@amiatroll6347 2 месяца назад
If it ain't broke, we don't tend to replace.
@pitobansheePR
@pitobansheePR 19 дней назад
Compressor wiring of loose connection on the breaker ? Since the compressor was reading good!!
@heatingairservices8708
@heatingairservices8708 2 месяца назад
never seen sight glass on core remover tool awesome & I will buy one Thanks
@Brock742
@Brock742 2 месяца назад
This video/ comments helped me on my journey, I now know what inrush current is, LRA, and now I have to figure out why you were ohming out the compressor to that pipe, which I assume is grounded.
@Brock742
@Brock742 2 месяца назад
Checking for internal short?
@moshemoshe-yy8hj
@moshemoshe-yy8hj 2 месяца назад
How old was that unit
@snidelywhiplash8923
@snidelywhiplash8923 2 месяца назад
Anyone know what that is growing?
@edorofish
@edorofish 2 месяца назад
Nice little crop. I wonder what they're growing. Almost looks like peanuts.
@zeldamoore8371
@zeldamoore8371 2 месяца назад
Sensible way to use back yard. My dad use to say "you can't eat that grass you put so much time into maintaining"
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Smart way to use the yard; plant some peppers or other vegetables and save $$$.
@markbeiser
@markbeiser Месяц назад
Sucks for me that the city won't let me raise a cow in my back yard, as I don't eat plants anymore!🤣
@myfastcars
@myfastcars 2 месяца назад
LOL!! WHAT KIND OF CROPS ARE THEY GROWING??
@joeteves6288
@joeteves6288 2 месяца назад
Meg the compressor, will signal bad, plus significant oil leak and age over 12 yrs old, time for a new AC system.
@WallaceRoseVincent
@WallaceRoseVincent 2 месяца назад
Nice haircut. Anyone catch the cracks in the mains during the contactor change out. There was no grommet in the hole so it's eventually going to fail and may have in the past Fun video to watch too. Not criticizing, just watching. 😊
@TheDan808
@TheDan808 2 месяца назад
Yes I noticed the cracks too.
@peterking1134
@peterking1134 2 месяца назад
If you don’t want to be injured by the rooster, have the customer secure it before you work on the AC
@HVACGUY
@HVACGUY 2 месяца назад
You obviously haven’t tried to catch a rooster
@zr1vetteman985
@zr1vetteman985 2 месяца назад
For all that don't know, getting spurred is similar to getting stabbed by s marlin spike!!
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Geese ar even worst and they always attack you from your back! LOL
@thomasandbethanygriffith892
@thomasandbethanygriffith892 2 месяца назад
Always like the video 😊
@user-ic9ie4lo4l
@user-ic9ie4lo4l 2 месяца назад
Should’ve checked compressor start with
@markbeiser
@markbeiser Месяц назад
True, but the readings he got when he did check it would not have shown there to be a problem, so it would not have helped. An insulation resistance tester would likely have revealed the problem, but that only gets pulled out when there is a problem, and most techs don't even have one.
@wilsonhortman4110
@wilsonhortman4110 2 месяца назад
Why did you turn the tstat without cking the condenser first. Why did you replace the Contactor before cking presssure. You saw the oil. 18:48 there is a guage port on the dryer. You could use it and save a lot of trouble. A few simple cks can save a lot of time. If tripping the breaker go straight to the compressor terminals and check.
@allenfoster9910
@allenfoster9910 2 месяца назад
My question is....why install parts without checking the compressor first after you found the bad contactor? I never do that.
@markbeiser
@markbeiser Месяц назад
Based on the readings he got, it would not have revealed any problems, unless he used an insulation resistance tester, and most techs don't even have one of those.
@jstephenrussell6443
@jstephenrussell6443 2 месяца назад
If the compressor has been sitting up for a long period of time it could be frozen which would cause it to trip the breaker. You may have to replace it. I would try a rubber mallet first and try get it to come lose, if not, then replace it. 😀
@Terrey-ct5yv
@Terrey-ct5yv 23 дня назад
Those are some Handy Dandy wire strippers....whats the name
@gaoutdoor4372
@gaoutdoor4372 2 месяца назад
I didn’t t see you check the condenser fan
@markbeiser
@markbeiser Месяц назад
He unplugged the compressor and turned the breaker on to see if the condenser fan motor ran. It did.
@joshemajavich799
@joshemajavich799 2 месяца назад
Maybe no good contact at the compresor connector from . I did not see you to measure at the connector on the compressor.
@ForgetU
@ForgetU 2 месяца назад
Chicken... haha
@HNIC86
@HNIC86 2 месяца назад
Sounds like that unit is a change out.
@plushdragon
@plushdragon 2 месяца назад
after work you got a free chicken dinner :)
@dogdiggingrj2089
@dogdiggingrj2089 2 месяца назад
What brand schrader tool are you using and where did you get it
@HVACGUY
@HVACGUY 2 месяца назад
Fieldpiece, trutech tools
@james6794
@james6794 2 месяца назад
check his other videos he did a review on it a week or 2 ago.
@nathang.1744
@nathang.1744 2 месяца назад
3:34 Rhode Island reds are usually pretty nice
@user-wn8mg2jh1d
@user-wn8mg2jh1d 2 месяца назад
Come on some people just don't think putting your garden up close to your AC Unit. Not bright at all they need to breath
@publicmail2
@publicmail2 2 месяца назад
bad breaker?
@tombeilman5579
@tombeilman5579 2 месяца назад
Beans I assume in the yard
@briantantlinger7936
@briantantlinger7936 2 месяца назад
12 Volt contactor?
@harrydickson4575
@harrydickson4575 2 месяца назад
👍👍👍
@bbaaspencer1
@bbaaspencer1 2 месяца назад
Looks like green acres?
@josereyes-go1pe
@josereyes-go1pe 2 месяца назад
I don't care that they don't pay me to clean it, but I do it so that the person no longer has a problem.
@ZoomIDoRx8
@ZoomIDoRx8 2 месяца назад
What a mess!
@edwardballek
@edwardballek 2 месяца назад
If there is no chirp inside,smoke detectors. Then there’s a lot of chirping outside.
@leejones3155
@leejones3155 2 месяца назад
You ain't lying 😂
@Parabellum-X
@Parabellum-X 2 месяца назад
That is the worst line set installation I have ever seen in my life. I can't stand HVAC companies who don't care about their installs. 4:19 I thought you shut off power here... What was that brief electrical hum?
@pauldusa
@pauldusa 2 месяца назад
Need new breaker
@davidb2438
@davidb2438 2 месяца назад
Yep, need to eliminate possibility though chances are low
@kylemason5951
@kylemason5951 2 месяца назад
New unit oil no good
@albertpaez6595
@albertpaez6595 Месяц назад
You Couldnt fix - because its unfixeable my dear friend and tradesmen
@bgreenwood9730
@bgreenwood9730 2 месяца назад
Thermal overload on the compressor
@james6794
@james6794 2 месяца назад
wasnt tripped. he was able to ohm out all three terminals on the compressor
@rafaellopez9411
@rafaellopez9411 2 месяца назад
Is that marijuana?
@HVACGUY
@HVACGUY 2 месяца назад
No
@Yawwee
@Yawwee 2 месяца назад
The power wire coming off the contactor looks like it is grounding to the case, has breaks in the insulation on both wires. You didn't see that ????? Your work is getting sloppy. I would have cut the ends off the wires and had good ends to go into the contactor lugs. Just my professional opinion to a non-professional.
@bbaaspencer1
@bbaaspencer1 2 месяца назад
I would looked at it and condemned it and just got a new unit. Throwing good money on bad to repair it I went through that! They kept replacing parts in within 3 months, it would have been cheaper to replace the unit.
@harryschrysan3183
@harryschrysan3183 2 месяца назад
Is that a suction line filter drier? Those are not supposed to stay on the system for more than 48h. Man that ac is gone man, she goneee maaan. 😅
@bobboscarato1313
@bobboscarato1313 2 месяца назад
They guy who installed the previous replacement compressor was looking forward to replace the unit altogether!
Далее
Making Loud Noises, and Not Heating Or Cooling
44:56
Просмотров 23 тыс.
AC unit failed but simple repair
13:54
Просмотров 13 тыс.
Condenser Left For Dead By Another Contractor
39:04
Просмотров 2,5 тыс.
Heat Pump System With Minor and Major Problems | HVAC
22:03
Reviving an Older Rheem Gas Pack! #hvacguy #hvaclife
47:18
THE SMOKE IS ROLLING OUT OF THE HOOD
19:37
Просмотров 30 тыс.