Main Eco Elite | Easiest Way To Change The Flow Turbine 

Advanced Boiler Training
Подписаться 8 тыс.
Просмотров 8 тыс.
50% 1

The main reason you would need to change the flow turbine would be a no hot water fault. As the water flows through the turbine the boiler isn't recognising it and therefore not giving you hot water but heating.
These resources will teach you how to diagnose and fix any boiler: signup.advancedboilertraining...

Опубликовано:

 

22 май 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 13   
@abualam4418
@abualam4418 2 года назад
Cool video 👍👍👍👍
@deanwallis9972
@deanwallis9972 Год назад
Great videos mate! I’ve learnt a lot. I’m having a problem with the same boiler. It’s fault was e156 under voltage. Check all voltage everything was fine. However it would not reset. So, I had a spare pcb so changed it and it all fired up fine/ 1 day later I get E168 that fault code ses needs a reset, the boiler now does reset but won’t fire up on heating. And hot water brings up the fault code again. What would be looking for next? Would the flow turbine and actuator give these fault codes? Thanks
@yensabi
@yensabi 3 года назад
Nice tip for that removal tool... Cheers....👍
@advancedboilertraining
@advancedboilertraining 3 года назад
That’s all good 💪
@ForrestLtd-yv2je
@ForrestLtd-yv2je Год назад
Hi. Great video. Thanks! I have this boiler but I don’t think I have the water turbine. There is a sensor clipped on to the water flow pipe. But I have an issue that there isn’t hot water when the go is on. Only when the bath is on. And this just started. Any idea what it would be?
@JamesSmith19900
@JamesSmith19900 3 месяца назад
Hi Did you ever make a video on taking 'the right hand block' out? (water pump?) My flow sensor is not coming out for love nor money, and as you have shown - access to it is not great. I've bought the tool but all it's doing now is slipping on the brass top of flow sensor. Thanks
@tristancraven3685
@tristancraven3685 6 месяцев назад
What is it when you turn a tap on upstairs .then turn the tap off Then the boiler still thinks the taps open yet when you turn the downsiars kitchen tap on and off the dhw light on the boiler goes off .
@MrHukd
@MrHukd 2 года назад
so what the reason for this specific tool? will a standard 18mm not work?
@gerrosrightboot
@gerrosrightboot 2 года назад
18mm socket does it too.
@MrHukd
@MrHukd 2 года назад
yeah thats what im thinking so is there another reason folks are buying a tool which only just seems like a standard socket?
@geomac7241
@geomac7241 Год назад
Needs to be a multi tooth 18mm so it won’t slip
@KneelBeforeZod.
@KneelBeforeZod. Год назад
Or you could use an 18mm socket.
@sidco123
@sidco123 2 года назад
Those things don't come out after 8 years.