MAINS FLUSHING A HEATING SYSTEM with THOROUGHFLUSH Kit | HOW TO | & Nerrad Tap Kit result. 

M J Tiff Plumbing
Подписаться 37 тыс.
Просмотров 19 тыс.
50% 1

flushing a heating system with the ThroughFlush mains flushing kit.
I’ve finally got my hands on the Thorough flush kit to try out flushing a heating system with. This system uses just mains water to completely flush and clean a full central heating system and the results speak for themselves. I also connect it to the Adey MagnaCleanse unit to catch the magnitite that is flushed out the system.
#plumbing #tools #howto
Subscribe to the Thoroughflush RU-vid channel-
@thoroughflushltd4905
Link to the ThoroughFlush site here-
www.thoroughflush.co.uk/produ...
Get your hands on the Unilite SLR-1750 for £50 using my code “MJTIFF”
unilite.co.uk/product/slr-1750/
Massive Thankyou to my channel sponsor UNILITE….
To save 25% on all Unilite orders type “MJTIFF” at checkout
unilite.co.uk/
Also check out the Trade Legends RU-vid channel-
/ tradelegends
And head to the Trade Legends site for some massive discounts
tradelegends.uk/

Хобби

Опубликовано:

 

3 дек 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 192   
@Micktheadventurer
@Micktheadventurer 2 месяца назад
Sold. Sold solddd. 😂. Mate, how is this free. Eternally greatful to all these amazing engineers on youtube sharing this ridiculously vast amount of knowledge. Half my old bosses where incredibly stingy with sharing knowledge and helping with development. I know it's a two way street, but them people just want a slave, not an apprentice. You're empowering people, educating, helping them to go on and make something of themselves. If i ever see you I'm buying you a drink!
@MJTiffPlumbing
@MJTiffPlumbing Месяц назад
Thankyou Mick 🙌🏼🙌🏼
@glyndavies591
@glyndavies591 Год назад
Nice bit of kit to flush heating systems my heating system is 46 years old and has always had Fernox inhibitor and have had no issues at all and congrats to Aaron for winning the nerrad tap kit
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yer it’s a great system. The inhibitor v no inhibitor is something in wanting to learn more about as there is pros and cons for each.
@garyredfern5303
@garyredfern5303 Год назад
Love that thorough flush kit. New year purchase me thinks. Well done to the prize winner. I always use inhibitor when filling up a system. It's what I have always done. But things change and so manufacturers instructions. Great video 👍👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep it’s a great bit of kit mate
@chrisholt2474
@chrisholt2474 Год назад
Hi Mark, a great test for the Thorough Flush, It looks like a fantastic addition to the took kit. Great idea to run it via the magnaclean unit. Well done to the winner of the tap kit, that is a fabulous prize. Have a great week, take care, regards, Chris. 👍👍👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks Chris…. Hope your well buddy.
@chrisholt2474
@chrisholt2474 Год назад
@@MJTiffPlumbing had a few problems but keeping going mate, cheers 🍻👍👍
@chriswright7167
@chriswright7167 Год назад
Well done Aaron. Enjoy it. Well done Mark. Well done everyone. Keep happy.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate
@jc-d7886
@jc-d7886 Год назад
Brilliant video, mate. Keep up the good work 👍💪
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thank you 🙌
@rm-mastering
@rm-mastering Год назад
Hi Mark, great video. Thanks for taking the time and effort. Congratulations to Arron 🏆
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks buddy
@andyfadian
@andyfadian Год назад
Thanks Mark for another great video. Well done Aaron 🎉
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks buddy👍🏼👍🏼
@1151simon
@1151simon 3 месяца назад
Top tip: screw end cap on connectors to make it easy to push them onto the hoses it just saved my hands 👌
@MJTiffPlumbing
@MJTiffPlumbing 3 месяца назад
👍🏼👍🏼
@derekwatt6314
@derekwatt6314 Год назад
Great video Mark.. will check out the thorough flush kit.. going to order another SLR750.. cheers mate
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks Derek 👍🏼👍🏼
@harryt259
@harryt259 Год назад
Evening Mark, that thorough flush kit looks decent I must say. Might have to invest in one next year. Congratulations to Aaron on the Nerrad kit! Excellent prize! 👏👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yer it’s an impressive and well made kit with all the bits
@Big_Old_Bondy
@Big_Old_Bondy Год назад
Yeah mate I bought one of those Unilites from you and it's decent. Well happy with it
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Glad you like it mate, they are great
@tommyblackman7119
@tommyblackman7119 Год назад
I love the idea of the throughflush kit I actually made my own version and works exactly the time Love it Think it’s better than a power flushn
@MJTiffPlumbing
@MJTiffPlumbing Год назад
They are a great kit
@michaelsharpin3369
@michaelsharpin3369 Год назад
Congrats Aaron nice one.
@ashvanbro9329
@ashvanbro9329 Год назад
Another great video mate hope your keeping well
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate, yer I’m doing ok mate…👌🏼🙏🏼
@leebesnard8054
@leebesnard8054 Год назад
Hi Mark. Cracking video as always. I use a power flush machine and I integrate the Adey Kitt onto it. Not cheap, but does a really good clean. The only thing that would put me off the thorough flush if mine died would be the amount of water that's wasted, but the price is good. Also need to invest in one of those flir cameras 👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yer it’s quite a water wasteful kit to be fair, I know what your saying
@aaronbrundle1257
@aaronbrundle1257 Год назад
Wow, thank you so much, love the videos, can’t believe I’ve actually won on a give away, I’m speechless
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Hey Buddy……. Congratulations mate. I bet you were surprised at the end 👍🏼👍🏼 Drop me an Email and I will get it sorted marktiff@hotmail.com
@Purebeltersteve
@Purebeltersteve Год назад
Well done mate, youll love it as it really saves time on the job
@AaronM4275
@AaronM4275 Год назад
I heard Aaron and I was yess 😂wasn’t me 😂enjoy mate 👏thanks for the video mark
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Unlucky buddy
@kevinisaac9139
@kevinisaac9139 Год назад
Great video that Mark I might get one of those 👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks buddy👍🏼
@bluedwarf8858
@bluedwarf8858 Год назад
That bit of kit seems a brilliant idea, and a space saver compared to those big power flushing machines
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep a lot easier to use than a big powerflush unit
@micmac69
@micmac69 Год назад
Nice video. Love the concept of the thorough flush👌 it doesn't take up much space like a Fernox Mk 2/3.machine would. Also the thermal imaging camera is a defo. Must get those links. Much appreciated.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate, yep the Thoroughflush is a brilliant unit👌🏼👌🏼
@getbry7452
@getbry7452 Год назад
Cheers for the vid, mate 👏🏻 I think most heating engineers might recommend a Spirotech air seperator should be part of the heating system to remove tiny bubbles of air which reacts with the water and the various metals which causes magnetite. No air should negate the need for chemicals. I think even Veissmann have it written in their boiler manual *not* to add inhibitor into the system! See you on the next one.
@Big_Old_Bondy
@Big_Old_Bondy Год назад
Dang, it says that in the Viessmann manual! Only just learning in this video about inhibbitor. Think I'll probly still use it for now until I learn more
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Indeed Bri….. airiators are a great thing to be fitting into systems. Yep I think Viessmann are pro water only…
@stuarttthomas7847
@stuarttthomas7847 Год назад
Veissmann have self purge, why would you even fit a Spirotech?
@utilitarian
@utilitarian Год назад
Well done Aaron. Quality bit of kit......rad chemicals wise it's a common sense approach if you can add them in. I see it as like using antifreeze in a car - it's not quite the same but you know what I mean
@MJTiffPlumbing
@MJTiffPlumbing Год назад
It’s a very debated topic at the moment… pros and cons for both but there is a big shift coming with things like overdosing systems becoming a concern.
@utilitarian
@utilitarian Год назад
@@MJTiffPlumbing I guess it makes sense but for the homeowner who can do it, you can understand overdosing a system because they aren't going to want half a bottle for the next 10 years (over exaggerated obvs)....for the pro that can calculate the correct amount it is a no brainer
@GIBiochip
@GIBiochip Год назад
Sunday evening entertainment complete!
@MJTiffPlumbing
@MJTiffPlumbing Год назад
🙌🏼👍🏼👍🏼
@sharpz44
@sharpz44 Год назад
Think I will get this, my house has small bore pipework in CH system which i hate ,this should help give it a clean
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep will help alot
@dannymatona3506
@dannymatona3506 Год назад
Pressure reducing valve is a good idea. My mate used his one to clean a system, that was vented converted to a combi. Water pressure was so strong, he sprung 6 leaks. He’s using a PRV now, after watching this. Thanks for the tip.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
No worries mate, yer the PRV is an adjustable one👍🏼👍🏼
@jasonsimpson3348
@jasonsimpson3348 Год назад
Congrats Aaron Great vid as always Mark Regarding inhibitor being added I was under the impression that the manufacturer requires it for the warranty to be valid I might be wrong . And I agree it must have some harmful products in it for the boiler and environment
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep if the MI’s say it needs it for the warrenty then you have to, however more and more companies are switching to water I hear
@jamesowen7609
@jamesowen7609 Год назад
Great video as always what fittings have you used to get onto the magnacleanse please.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks buddy….. Camlock fittings 👍🏼👍🏼
@sergiofernandez3725
@sergiofernandez3725 Год назад
Would that work on an F&E system? Is it possible to connect the power flush to the top of the radiator by removing the bleed valve and cap at the other end? Loved the idea of putting the magna clean on the exhaust water
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep you just need to isolate the header tank and vent👍🏼👍🏼
@henryeadie7972
@henryeadie7972 Год назад
Dont boiler warranties require Inhibitor to be used and proof provided with one of those Ady Pro Check kits?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep some do as its a big industry, always check the MI’s. However there is a shift coming in this as putting chemicals into water can cause reactions which is never a good thing to have as it’s causes corrosion due to a reaction releasing air.
@sheriefgerges7789
@sheriefgerges7789 Год назад
Great video, do you have link or model the thermal image camera u are using please. Thank you
@MJTiffPlumbing
@MJTiffPlumbing Год назад
It’s a HikMicro Pocket 2 buddy 👍🏼👍🏼
@jasonoliver9549
@jasonoliver9549 2 месяца назад
OK so I have waited awile for this product to be tested, watched when it come out a nd was impressed, I have the magna clean unit but do I go power flush or though flush? Plz help with advice guys.
@MJTiffPlumbing
@MJTiffPlumbing 2 месяца назад
Me personally I would go for this…. But that’s my view.
@sheriefgerges7789
@sheriefgerges7789 Год назад
Would like to ask for advice about connect thorough flush correct me please if iam wrong Can I connect it to. 1. The isolation valves on the radiator OR 2. To air vent one side and the cap off of the radiator another side Thank you
@MJTiffPlumbing
@MJTiffPlumbing Год назад
They can be connected to a rad if that’s the only way….👍🏼👍🏼
@thebeardedwunderer1503
@thebeardedwunderer1503 11 месяцев назад
Would you mind telling me what thermal camera your using please, also would you recommend it? Thanks
@MJTiffPlumbing
@MJTiffPlumbing 11 месяцев назад
It’s the HikMicro Pocket 2….. it’s a great unit👌🏼👌🏼
@georgereynolds6497
@georgereynolds6497 Год назад
If you close the inlet and outlet will the pump circulate the water to temperature to help cleaner in the system?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yes it would do if you want to get heat circulating
@theforkieman
@theforkieman Год назад
Great video as always. Loved thoughflush demo. Deffo good bit of kit. Do you have to isolate the boiler to stop going though it or not. But enjoyed as usual. Great work
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate, nope don’t need to 👍🏼👍🏼
@jimcooper4201
@jimcooper4201 9 месяцев назад
Can this be used on narrow bore heating pipes
@richardsedorski1206
@richardsedorski1206 Год назад
Nice one.👍👍👍😎😎😎
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate 👍🏼👍🏼
@Mr1Grumpy
@Mr1Grumpy Год назад
Is it the same process with a header tank heating system in the loft? Thanks.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Would have to cap the tank off mate 👍🏼👍🏼
@RuzzaV2
@RuzzaV2 Месяц назад
I was wondering until I seen.. if you was to leave the dump valve closed whilst the mains is open to the flow and returns, that would act as a filling loop right??
@MJTiffPlumbing
@MJTiffPlumbing Месяц назад
Indeed it does
@adamwhyman1788
@adamwhyman1788 11 месяцев назад
Hey mark great video.. i had to go and purchase one! Great bit of kit. Where did you get the fitting to attach to your magnacleanse. Cheers
@MJTiffPlumbing
@MJTiffPlumbing 11 месяцев назад
They are very good😉😉 Get some cam locks off eBay to attach to the Magnaclean
@Toplineph
@Toplineph Год назад
Do you need to isolate the flow and return to the boiler, so you don’t flush the crap through the heat exchanger?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
You can do or you can flush it through there aswell
@carguillo1
@carguillo1 Год назад
nice vid Marke whats the make of the thermal camera thanks mate
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks mate, this is the HikMicro Pocket 2…. Great bit of kit
@MrVictorvolvo
@MrVictorvolvo Год назад
Brilliant Video Mark, just got the Thoroughflush myself. What thermo Camera are you using?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thanks 👍🏼👍🏼 the camera is the HikMicro Pocket2
@stephenfanthorpe2708
@stephenfanthorpe2708 Год назад
I think with an adey in series on the outlet that’s a nice piece of kit
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep I was very impressed
@stephenfanthorpe2708
@stephenfanthorpe2708 Год назад
Turning out i think you doing it , excuse my premature comment mark
@Mr1Grumpy
@Mr1Grumpy Год назад
Nice one. Why not open all rads up and flush or best to do one at a time? Thanks.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
I flush the whole system then do a rad at a time to make sure they are all flushed
@gardgas1
@gardgas1 Год назад
I like the idea of the thorough-flush, as sometimes, as we all know, a mains flush will be hard to beat, especially used in conjunction with a Magnacleanse. I looked at the thorough-flush, but decided to make a manifold myself for about £30 that does exactly the same job, granted it looks nowhere near as good as that, but it's simply a few components that all of us engineers work ith on a near daily basis. Keep up with the great and informative videos 👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Thoroughly flush is a superb bit of kit
@aminsajawal3935
@aminsajawal3935 Год назад
Hi mark great video as always, Regarding the link for the unlite offer don’t think you have put it on. Thanks you
@aminsajawal3935
@aminsajawal3935 Год назад
Sorry mark found it lol 😂
@MJTiffPlumbing
@MJTiffPlumbing Год назад
🤣👍🏼👍🏼
@tomstrutton4351
@tomstrutton4351 Год назад
So on an older open vented system you’d probably not wanna risk using this right? Too much pressure on old pipes you reckon?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
It would be one to take a look at if I’m honest, probably best with just the MagnaCleanse and run it as it usually is ran
@julianmcafee5976
@julianmcafee5976 Год назад
Would you be better putting the magnaclese magnates into the loop to stop it going back round the system and through the heat exchanger rather than on the dump valve ?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
It goes straight out the dump hose to the drain👍🏼👍🏼
@runamonk
@runamonk Год назад
Question for you, would you do a flush on a new boiler install that's replacing a 20 year old boiler? When would you recommend a flush for a heating system?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
100%….. in fact it’s part of the boiler warranty to flush the system
@runamonk
@runamonk Год назад
@@MJTiffPlumbing thanks dude appreciated!
@AngeredNumber1988
@AngeredNumber1988 Год назад
I would have thought these kits would come with a double check valve as standard, surprised they can sell it without one due to water regs. Pressure reducing valve is a good idea though.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
I guess it’s all down to price point….. not a problem to get one👍🏼👍🏼
@Triune3
@Triune3 Год назад
Why does it need to connect the magnets on the dumping side? It’s not coming back anyway.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Just as a visual thing to see what else is being removed from the system….. great to show the customer
@paulsmith2931
@paulsmith2931 Год назад
All the boiler manufactures want the system clean and inhibitor in the system now to keep the boiler under warranty, and most boilers have a ten year warranty, and it is a legal requirement now since June that when you have a boiler serviced you must check the water quality, all the test kits pick up wether there’s inhibitor in the system or not, did you give the customer the water quality results from you Adey test kit at the end of the job, which would say inhibitor is recommended? Personally after carrying out that job I would have dosed it with inhibitor.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep indeed if it’s in the MI’s then you’ve got your hands tied. However that doesn’t mean it’s right, and as the “chemical industry” is worth so much they will push for this, however it is beginning to change. Pros and cons to the whole debate which is set to run for a while yet.
@johnnyfandango1625
@johnnyfandango1625 Год назад
Is that Pocket 2 Thermal image camera any good? I'm surprised Thoroughflush and Hikmicro didn't give you a discount link as you are promoting their products. They both look good. We have been doing mains flushes for years as I personally prefer it on systems that are not too bad.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yes it’s the Pocket 2 from HikMicro…. I have worked with them before and have a discount code (was a while ago so not too sure if it’s still valid) and always good to promote Ricky who owns Thorough-Flush 👍🏼👍🏼 Sometimes it’s about promoting great products 👍🏼👍🏼
@archielever
@archielever 7 месяцев назад
Nice vid..thinking of getting one of these..but no inhibitor..i dont think i would be able to not put inhibitor in..its in my heating engineer d.n.a ...i love the smooth feel and smell of inhibitor..my customers love inhibitor..i was raised on inhibitor 😊
@MJTiffPlumbing
@MJTiffPlumbing 7 месяцев назад
There’s alot of info out there now to not put inhibitor into systems….. pros and cons…
@snoophoggywhite3624
@snoophoggywhite3624 10 месяцев назад
Sound vid buddy, great to seee it in action, can i ask what the cost would be to have thia done on a typical house with 10 rads ?
@MJTiffPlumbing
@MJTiffPlumbing 10 месяцев назад
Thanks mate…. Depends on so many things but as a rule of thumb I work on an 8 rad combi fed system at £450 then £50 extra per rad
@snoophoggywhite3624
@snoophoggywhite3624 10 месяцев назад
@MJTiffPlumbing appreciate the reply thanks bud. Next question is gonna be controversial, let me know when your ready
@nickcannon5592
@nickcannon5592 Год назад
I only ever use mains water flush, I'm always worried what chemicals will do to older systems
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep I know what you mean buddy.
@steveyboyXRP
@steveyboyXRP Год назад
i use a proflush pricey but well worth it
@MJTiffPlumbing
@MJTiffPlumbing Год назад
👍🏼👍🏼
@peterbridges6851
@peterbridges6851 Год назад
Why not interupt the pipe work at the boiler?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
As said in the video buddy.......
@Purebeltersteve
@Purebeltersteve Год назад
Chemicals only really used in the UK is because of the water quality. Hard water areas would need chemicals in water due to minerals etc. If youve clean soft water, no chemicals would be needed. Chemicals also help with heating systems do decrease the evaporation process that we all get in summer months and heating not on.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep pros and cons of it and something I want to get more knowledge on as at the moment it’s the chemical industry’s pushing the infomation as it’s in there interests
@jasonoliver9549
@jasonoliver9549 Год назад
How much is the kit and do you have a link
@MJTiffPlumbing
@MJTiffPlumbing Год назад
It’s around £290+ VAT…… link in the discription 👍🏼👍🏼
@colinb6035
@colinb6035 Год назад
Are you still vibrating the rads?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep to agitate the sediment that has settled
@SuperWayneyb
@SuperWayneyb Год назад
Evening all 🤘😎🤘
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Evening Wayne🙌🏼🙌🏼
@SuperWayneyb
@SuperWayneyb Год назад
@@MJTiffPlumbing Not had mine out of the box yet but will be soon 👍👍
@jezlucas3878
@jezlucas3878 Год назад
Those jubilee clips would worry me blowing off the fitting
@MJTiffPlumbing
@MJTiffPlumbing Год назад
They ain’t going anywhere mate, they are solid👍🏼👍🏼
@jezlucas3878
@jezlucas3878 Год назад
@@MJTiffPlumbing very interesting bit of kit
@reecet835
@reecet835 Год назад
Shame really need that kit 🙃🙃 but never great video just before football
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Unlucky buddy
@reecet835
@reecet835 Год назад
Maybe do never one for Christmas 👍🏽👍🏽🤣🤣
@johnlee701
@johnlee701 Год назад
Well done Aaron (you swine 😂😂).👍🏻
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Hahahaa
@chrisb4009
@chrisb4009 Год назад
Worth thinking about auto bypass valves, you can waste a lot of flow
@MJTiffPlumbing
@MJTiffPlumbing Год назад
In what way do you mean mate?
@chrisb4009
@chrisb4009 Год назад
@@MJTiffPlumbing if a a system has an auto bypass valve set at 0.5 bar and you put 1bar in the flow it will open and the flow will go through the bypass valve and not the radiators your trying to flush.
@qmob0121
@qmob0121 Год назад
I thought it was in regs that you have to add inhibitor
@MJTiffPlumbing
@MJTiffPlumbing Год назад
All depends on the MI’s
@lulaferreira7640
@lulaferreira7640 Год назад
👍🏻
@MJTiffPlumbing
@MJTiffPlumbing Год назад
👍🏼👍🏼
@farukadam1696
@farukadam1696 Год назад
👍
@MJTiffPlumbing
@MJTiffPlumbing Год назад
👍🏼👍🏼
@giorgosaxis
@giorgosaxis Год назад
So this is simple 4way valve,with parts that anybody can make it half price.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Are you asking me or telling me…..🤣 Everything you buy is “simple” and “made of parts”…… it’s called industry and business
@williambelford9661
@williambelford9661 Год назад
With some heating engineers charging up to £800 for a power flush could this be a cost effective investment for a competent DIYer?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Indeed mate…..👍🏼 Power flush costs are all very dependent on systems, what set up, how many rads etc etc….
@mcDarkD
@mcDarkD 7 месяцев назад
i just dont get the point of this? drainoff on the flow and return and just mains flush using the filling point, boiler has stop valves i use a magnacleanse with a kenco power flush. i also mains flush, i use a hosepipe i have no carrying extra hoses etc. i just dont get it.
@MJTiffPlumbing
@MJTiffPlumbing 7 месяцев назад
It’s not for you then buddy….👍🏼👍🏼
@jasonbrooksbank
@jasonbrooksbank Год назад
Inhibitor in systems. Manufacturer pushing testing on yearly service.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep….. they will as it’s a huge industry with a lot of money involved.
@bmxpro565
@bmxpro565 Год назад
you didn’t not flush through the rad you took off? Could you not have connected the pipes to the rad tails?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
I flushed it out when I removed it just didn’t show it on the video buddy….
@bmxpro565
@bmxpro565 Год назад
👍 didn’t think you’d miss it
@bmxpro565
@bmxpro565 Год назад
Also if your interested about system inhibitor research heat geeks video on VDI 2035 it tells you the relationships between levels of oxygen and conductivity of the system water creating corrosion
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep Adams content is great👍🏼
@ibiahmed143
@ibiahmed143 Год назад
Firstst view
@MJTiffPlumbing
@MJTiffPlumbing Год назад
🙌🏼
@laghribi_abdalkhder8792
@laghribi_abdalkhder8792 Год назад
I want to ask a question, if an immigrant asked you without work papers, would you hire him? I want an honest answer (he's good at plumbing)
@MJTiffPlumbing
@MJTiffPlumbing Год назад
If he was good at his job, reliable and trustworthy then I wouldn’t have an issue
@laghribi_abdalkhder8792
@laghribi_abdalkhder8792 Год назад
@@MJTiffPlumbing you're a great man
@chrisb4009
@chrisb4009 Год назад
Most MI’s require chemical inhibitors as part of the warranty T&C’s. I’m sure VDI is great but you’re opening yourself up to hug liabilities if you invalidate a customers warranty
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Indeed they do however companies like Viessmann are now saying just water is preferred. It’s an industry that is shifting away from chemical flushing
@deanmiles8421
@deanmiles8421 Год назад
No inhibitor?? I've never heard of that these days.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Do some googling mate, it’s becoming a big thing
@deanmiles8421
@deanmiles8421 Год назад
@@MJTiffPlumbing I have a look and don't think I will be joining the hippy brigade, goes against the grain
@davehunter6920
@davehunter6920 Год назад
contentious mark....not to ad inhibit?
@MJTiffPlumbing
@MJTiffPlumbing Год назад
I’m trying to learn a bit more about the whole chemical side of things as it’s very interesting
@JM-uo5vp
@JM-uo5vp Год назад
Do you know what you can get for the price of a MagnaClense and a ThroughFlush…. A Powerflush machine 😂
@MJTiffPlumbing
@MJTiffPlumbing Год назад
…… and, your point is????
@alphabuilders
@alphabuilders Год назад
@@MJTiffPlumbing Point is a proper power flush has similar to a thorough flush valve built in as standard. has mains pressure option and has a whopping big motor to force some power through as well as a whopping big tank to catch the debris. You can do it all better for the same price.... If you know how to use the valves under the boiler and are smart about where to add a extra drain point you can do what this does (minus the reverse flow) using the pipes on the wall and the filling loop so its not really such a great buy... Just add a drain point on the flow pipe under the boiler. Close both flow and return on boiler and let the filling loop run with the drain point on the flow pipe connected to a drain..... Think about it...
@johncampbell6715
@johncampbell6715 Год назад
Alphabuilders. Another idiot.
@scottbob3917
@scottbob3917 Год назад
Not slating it but it's a lot of hasel and a lot of messing around and setting up
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Not really, takes about 10minutes…👍🏼
@michaelgiles9545
@michaelgiles9545 Год назад
2 -0
@MJTiffPlumbing
@MJTiffPlumbing Год назад
👍🏼👍🏼
@lemmykilmister450
@lemmykilmister450 Год назад
If it's a sealed system it doesn't need it (unless warranty related). Any corrosion that takes place (minimal), will stop once the oxygen in the water is converted to oxide. Open vent on the other hand its essential. I've never used inhibitor in my system which I installed 20 years ago and the water is crystal clear, with no sludge deposits in the rads. The Euros have got it right with VDI. Don't start me on filters 😂 money making racket
@MJTiffPlumbing
@MJTiffPlumbing Год назад
This is what I like to hear👍🏼👍🏼
@lewbaker
@lewbaker Год назад
I think a lot of the chemical vs not comes down to ideal vs reality, ideally a heating system should be free of contamination and oxygen so corrosion in the system will be pretty low, but in reality it's just not the case. A lot of systems are gonna let oxygen in with small leaks and not everyone keeps on top of bleeding out rads, some people have pretty suspect water quality especially old tank fed systems and there's the hard water issue in a large portion of the country. Yeah ideally we shouldn't have to use the chemicals, but in reality unless it's a brand spanking new system with great water quality it's gonna need some help, especially when it comes to cheap landlords who don't wanna fix anything or elderly customers who had no idea a rad valve has been leaking for 5 years letting air into the system.
@MJTiffPlumbing
@MJTiffPlumbing Год назад
Yep great points there buddy 👍🏼👍🏼
@chadhughes7269
@chadhughes7269 Год назад
Hi mark are you aware of the extraction kit for valve bodies? Trying to push the magnetite through such a small gap in the valve body is difficult according to the thourough flush bloke
@MJTiffPlumbing
@MJTiffPlumbing Год назад
That’s why using a cleaner such as Adey MC1 works so well as it suspends the magnitite to get it out the system….. you can’t be going round changing every valve body on a flush…
Далее
(Part 1) MagnaCleanse Walk Through
26:39
Просмотров 36 тыс.
Flushing a microbore system
13:01
Просмотров 6 тыс.
ADEY MAGNACLEANSE CLEAN HEATING SYSTEM SLUDGE
21:49
Просмотров 247 тыс.
Why Did I Not Get A Press Gun Sooner!!
22:01
Просмотров 6 тыс.
HOW TO CHANGE TOILET GOES WRONG!
21:37
Просмотров 593 тыс.
Don´t WASTE FOOD pt.2 🍕
0:19
Просмотров 44 млн
Обхитрили маму
0:24
Просмотров 3,2 млн