Тёмный
No video :(

No. CA Perimeter Wire as per CA Building Code 

Jason Cherene
Подписаться 826
Просмотров 49 тыс.
50% 1

How to tie a perimeter wire on a t-bar ceiling to code in Northern California

Опубликовано:

 

3 май 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 42   
@smtitmas
@smtitmas 5 лет назад
I was about the same age as this kid (15) back in '85 when i started doing drop ceilings for my dad so this video really makes me smile. Props to you for teaching the next generation of tradesmen this invaluable skill.
@DmofukinLee
@DmofukinLee 3 года назад
He is literally better at teaching this technique than any journeyman i have ever had to work with.
@dan9001
@dan9001 6 лет назад
Does the little dude walk stilts?? Keep at it bud!!
@jasoncherene6801
@jasoncherene6801 6 лет назад
Not really supposed to use stilts in CA., but he is going to learn how to use them. He only gets to work summers. Thanks for the cool comment!
@HM-uf1lv
@HM-uf1lv 6 лет назад
What i don't understand is...why is there a requirement for heavy gauge wire at perimeter cross bars? The physics of the application doesn't make sense in seismic or structural engineering...as the tile will be less than 1 lb. Cut the wall tab short to slot into the level track. Been dealing with too many installs where the thick wire prevents panel removal. Old codes should be challenged. I hate drop ceilings esp where the installers hide short cuts. Seems like the kid is doing OK...just reading info off the wall with a few weeks on the job. Probably the contractor's kid learning the business.
@jasoncherene6801
@jasoncherene6801 6 лет назад
H M I agree totally with you. I repaired ceilings after the 89 quake in SF and seismic posts did more harm than good, I thinks that's a code that needs to be reevaluated also. Good catch on the reading off the wall. This video is more for him, if you can't teach it you don't fully know it. Thanks for the comment.
@erniejohnson9182
@erniejohnson9182 6 лет назад
I've been doing grid for 20years and if another carpenter did grid like this or tied a wire like this he would be all time clean up person this is a joke...amatuer hour
@jasoncherene6801
@jasoncherene6801 6 лет назад
Years of experience is no gauge of skill. I know workers that have been doing "grid" for twenty years and that's all they can figure out how to do, that's why they have been doing "grid" for so long. I'm glad you can tie a wire faster and better, good for you! This video is to show how to make a California code compliant wire tie nothing more. Where does the video mention "doing grid". Keep making awesome comments, I'm sure you're going to excel. Good luck in the rest of your career.
@HM-uf1lv
@HM-uf1lv 6 лет назад
Ernie Johnson I get the (code) reasoning why drop ceilings are used commercially, but why hasnt the trade come up with a better standard? This stuff is 50 years old and hasnt improved much for easier end-user care or preventive maintenance to mechanical equipment. Every tile I've encountered has been blocked by suspension twists or zero clearance above. I even remove those hold down clips because no one has ever had tile lift in a large commercial plenum.
@andrewlavigne2572
@andrewlavigne2572 5 лет назад
First off you don’t tie your wires off to your tees....code says only mains
@ralphmaestas4220
@ralphmaestas4220 5 лет назад
Ya I've been an installer for 17 years and I couldn't agree more
@jasoncherene6801
@jasoncherene6801 5 лет назад
@@andrewlavigne2572 CA code, other states have it easy
@rolandogallardo395
@rolandogallardo395 4 года назад
Why you need wires? on those short T runners
@jordanbergmann4067
@jordanbergmann4067 5 лет назад
Why on earth would you tie a wire on a perimeter tee? Seems to me it's doing nothing more than what the angle is already doing. You need to hang the mains not the tees. I mean unless you know something I don't this makes no sense to me. Also that's a whole lot of excess wire and its twisted too loose like that, I twist em tight and close to the wire and leave no excess.
@jasoncherene6801
@jasoncherene6801 5 лет назад
California seismic code. Any tee over eight inches has to have a wire
@tankm69
@tankm69 5 лет назад
Props to the kid for sure . Is the wire a little loose ? Yea a bit . I’d prob be cursing dropping tile with em tied like that but props for startin em young . These non Cali installers have no idea how good they have it . Perimeter wires on anything over 8”. Seismic’s every 12’. And don’t get me started on hospitals and schools. Yikes. Imagine how much footage we could get up with the old wire every 4’ on the mains haha. Nice vid.
@slippy11ful
@slippy11ful 3 года назад
Im gonna guess because the end peices are the easiest to fall out and if earthquake hit less pieces would fall on people's heads. That's the only thing i could think of tho. Fu@% California tho lmaoo 😂😭
@Legenddjt
@Legenddjt 2 года назад
@@slippy11ful would think they would have some kind of clip .
@reymellee9850
@reymellee9850 2 года назад
California Code my man
@WaqarAzeem-dp7cr
@WaqarAzeem-dp7cr 3 года назад
Hey dr bro how are you
@IBRAHIMPOP
@IBRAHIMPOP 5 лет назад
I am gypsum work and p.o p experience india and gulf experience gulf return
@northpolltv6598
@northpolltv6598 4 года назад
Man, that's crazy. What a waste of time and money. Getting the panels in and out with those thick wires at every cross T would be a bitch, too. California must be a terrible place to do construction.
@jasoncherene6801
@jasoncherene6801 3 года назад
Yep a bit over kill.
@ecuador198266
@ecuador198266 5 лет назад
Somebody teach him wrong this young kid never you tide wire in the crossT. The wires go in the main ok 👎👎👎👎
@jasoncherene6801
@jasoncherene6801 5 лет назад
This is for CA code. You have to have a wire on all cross tees longer than eight inches.
@jasoncherene6801
@jasoncherene6801 5 лет назад
Did you even read the title?
@ecuador198266
@ecuador198266 5 лет назад
@@jasoncherene6801 yea right in 5"f hall way
@jasoncherene6801
@jasoncherene6801 5 лет назад
You don't read the title and don't read the reply any tees longer than 8 inches doesn't matter if it is a 45 inch wide hallway
@reymellee9850
@reymellee9850 2 года назад
Lol haha. California Code my man
@jimbendtsen8841
@jimbendtsen8841 Год назад
Putting wires on perimeter tees is bullshit.
Далее
How to Install Ceiling Grid
15:45
Просмотров 459 тыс.
Montage d'une ossature à crochet Quick-Lock® Hook-On
3:57
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Просмотров 14 млн
❌Разве такое возможно? #story
01:00
AMAZING Idea With An Ax !
10:54
Просмотров 169 тыс.
INFINITE RANGE ELECTRIC CAR - DIY Build
24:28
Просмотров 617 тыс.
How to Install 650 Drywall Ceiling Grid
17:28
Просмотров 45 тыс.
Electrical Rough-In Inspection (New Construction)
10:34
Barbwire fencing tricks
8:41
Просмотров 1,1 млн
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Просмотров 14 млн