Тёмный

OFF-GRID - PowMR 3000W 24v All In One Solar Inverter Charger 

Justin's Project
Подписаться 19 тыс.
Просмотров 33 тыс.
50% 1

PowMR 3000W 24v All-In-One Solar Inverter Charger - In this video, I share how I wired up my test center and cover some important highlights about the inverter itself. Join me in continuing the discussion over at the new forum: www.justinsproject.com
BUY THIS SOLAR INVERTER CHARGER ON AMAZON: amzn.to/3ZAFzNJ
HAVE A QUESTION & WANT ANSWERS:
Get the answers at www.justinsproject.com
Post your question on the DIY Solar Builds Forum:
www.justinsproject.com/questi...
All My Videos
• Playlist
BEST Place to BUY SOLAR Equipment:
signaturesolar.com/?ref=justi...
Not only are you receiving the best prices but you are also working with a team that is customer-focused!
Want a chance at some cool giveaways?
To qualify just subscribe to this channel and like the video.
Don't forget to register for free at the DIY Solar Builds community.
www.justinsproject.com/login/...
You will be automatically entered into all current and future promotions.
Feel like shopping? Support My Channel - Shop Amazon: www.amazon.com/shop/justinspr...
*** If you purchase anything on Amazon after visiting one of our items we get a small commission at no additional cost to you and it helps support our channel. Thank You!
If you made it this far don’t forget to subscribe to the channel: ru-vid.com...

Video Timeline:
00:00 Introduction
00:56 Configuration
01:42 Wiring
08:57 Size & Weight
09:35 Install Tips
10:13 Display
10:52 Noise Level
11:55 Powering Appliances
14:52 Thank You!
#PowMR #solarinvertercharger #diysolar #diysolarbuilds #solar

Хобби

Опубликовано:

 

1 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 142   
@JustinsProject
@JustinsProject 10 месяцев назад
If you are in the market for this inverter you can buy it on Amazon: amzn.to/3ZAFzNJ
@verohandymike
@verohandymike Месяц назад
I have this same unit. You can note that if you are off grid like me, you can connect your generator as your AC in. So on a cloudy day you can just turn your generator on and get the same charge/use benefit.
@JustinsProject
@JustinsProject Месяц назад
Thanks for sharing!
@shimronsimpson3380
@shimronsimpson3380 12 дней назад
Does it has an ats for generators?
@raymondumpster
@raymondumpster 14 дней назад
thank you so much, sir...now I understand the meaning of the GRID.
@JustinsProject
@JustinsProject 12 дней назад
You are most welcome! Thanks for watching and commenting 👍🏻
@earthenergyhex
@earthenergyhex 7 месяцев назад
I enjoy your reviews, I hope your channel takes off.
@JustinsProject
@JustinsProject 7 месяцев назад
Much appreciated 🙏 Thanks for watching and commenting 👍🏻
@chijiiloabachie3836
@chijiiloabachie3836 2 месяца назад
Nice and in-depth.
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@kamolhengkiatisak1527
@kamolhengkiatisak1527 7 месяцев назад
This is enlightening explanation.
@JustinsProject
@JustinsProject 7 месяцев назад
Thanks for watching and commenting 👍🏻
@sheilaashley
@sheilaashley 10 месяцев назад
Keep this type of content comin’! 👍🏼
@JustinsProject
@JustinsProject 10 месяцев назад
Stay tuned, I have tons more coming. Thanks for watching and commenting 👍🏻
@sheilaashley
@sheilaashley 10 месяцев назад
Cool looking forward to it!
@jackmehoffer7819
@jackmehoffer7819 4 месяца назад
Excellent video thanks!
@JustinsProject
@JustinsProject 4 месяца назад
Glad you enjoyed it! Thx
@tedfelipcatarata9964
@tedfelipcatarata9964 6 месяцев назад
Thank you so much!
@JustinsProject
@JustinsProject 6 месяцев назад
Thanks for watching and commenting 👍🏻
@braianlopezacosta259
@braianlopezacosta259 9 месяцев назад
Good job 👏
@JustinsProject
@JustinsProject 9 месяцев назад
Thank you! Cheers!
@ratnadeepdhar4816
@ratnadeepdhar4816 Месяц назад
Nice watching. Regards
@JustinsProject
@JustinsProject 29 дней назад
Many thanks
@johnaugsburger6192
@johnaugsburger6192 7 месяцев назад
Thanks
@JustinsProject
@JustinsProject 7 месяцев назад
Thank you for watching and commenting 👍🏻
@JR88888
@JR88888 3 месяца назад
Thank you! The information you provided was beneficial and insightful.
@JustinsProject
@JustinsProject 3 месяца назад
Glad it was helpful! Thanks for watching and commenting 👍🏻
@MyAussieHouse
@MyAussieHouse 24 дня назад
What is the rs 232 port, on the left hand side, for?
@gchacon316
@gchacon316 5 месяцев назад
Great video! You touched on something I could use a little help with. Bonding. I am in an RV. I have a 3000W unit like this. When I connect me unit to the RV I'm using a 50 Amp (NEMA 14-50) on the RV and the same on my solar shed. I wired the connections with a jumper for the 2 live legs. I have an 8 foot grounding rod. Should I be providing a ground to the unit to the grounding rod? Or to the distribution box? And should I leave the green screw in to bond the ground and the neutral? I would really appreciate the help. Greg
@JustinsProject
@JustinsProject 4 месяца назад
Hi Greg, I would definitely run that by an electrician. There should only be one ground neutral bond and that would be at the first point of service. If it's a subpanel, you should remove the green screw. You would not want another bond after the main service panel. Hope that was helpful.
@rontech34
@rontech34 10 месяцев назад
I have 2 of the same units I just finished installing with 3000w of solar for each unit I installed a separate panel next to my main panel I removed all the circuit's out my main panel except the double pole breakers and put them in the new panel total of 24 breakers 12 breakers on each leg 12 on inverter 1and 12 on inverter 2 total of 24 breakers 15 and 20 amp breakers running 8# wire from inverter to second panel and same for utility input been running now for 3 weeks no problems at all I'm using 24v 600ah lifepo batteries on each inverter each inverter has it's own set of batteries of 24v 600ah each inverter in the panel the inverter is hooked up to a double pole 40 amp breaker as a main breaker disconnect I'm going to post video in the next few days so right now I'm 80% off grid only thing hooked up still to grid is my a.c. unit and heat unit everything else is off grid from 11am to 6pm running off solar only after 6pm when sun goes down batteries kick on running off batteries at night and only use about 20% of batteries at night till the morning then solar charge back to full then once full then house runs off solar
@JustinsProject
@JustinsProject 10 месяцев назад
Awesome! Love hearing things like that. Thanks for watching and sharing your experience 👍🏻
@The_Defiant_One
@The_Defiant_One 4 месяца назад
Sounds like a nice system. Post that video soon please.
@rilosvideos877
@rilosvideos877 2 месяца назад
Thanks for sharing - great info! What is the minimal PV-input voltage the MPPT-charger can work at? And what is the MPPT-range for input from PV? Did you measure the stand-by consumption with inverter on/off? From the batt. it is probably about 20...40W but from mains input it often takes much more - don't know why? With inverter off it should be less.
@JustinsProject
@JustinsProject 29 дней назад
I would refer to the product manual of the inverter on PowMR's website to insure you have all the information you are looking for. Thanks for watching and commenting
@ralphyc81
@ralphyc81 5 месяцев назад
Can the input and the output 240v be paralleled if you intend to feed the power from thr inverter back into thr main distribution panel?
@JustinsProject
@JustinsProject 5 месяцев назад
This model is designed for Off-Grid use.
@Brandon_Jesus
@Brandon_Jesus Месяц назад
Do you know anything about the PowMr 12v 1600watt AIO? as far as i can tell it only puts out 220v @ 50hz. It would be perfect for my use if it were 120v @ 60hz. Im curious if there is a setting that changes the hz from 50 to 60 on your model.
@JustinsProject
@JustinsProject 29 дней назад
I don't. It might be on their website though. If you find it, let us know.
@tribalncgaming1091
@tribalncgaming1091 9 месяцев назад
got this system put together .. now taking it down to the RV.. do i need to worry about backfeeding the grid? i assumed the AC input was to charge batteries and / or bypass to run the load.
@JustinsProject
@JustinsProject 9 месяцев назад
It is not a grid feeding system. You assume correctly. Thanks for watching and commenting 👍🏻
@tribalncgaming1091
@tribalncgaming1091 8 месяцев назад
@@JustinsProject question on the ground.. i am not using a distro panel.. literally just pushing the AC - OUT to a dual 110v outlet.. so the ground and neutral can connect to the same AC OUT neutral?
@user-ko3kt3qs3o
@user-ko3kt3qs3o 5 месяцев назад
Hey Justin do you have a link or model number for the load center I can't seam to find it on the internet. Thanks
@JustinsProject
@JustinsProject 5 месяцев назад
It's an Eaton load center. I picked it up at Menards.
@goodoz9942
@goodoz9942 9 месяцев назад
About three years ago, I purchased six 24V 200W solar panels (before I knew what I was doing...thinking bigger was better). I have several other 12V 200W which are perfect for my 150VOC charge congrollers. But I still have those six pigeons...24V, each with 45.4 VOC. My battery banks are 24V. All of the panels are ground deployed/moveable...so with those six panels I'm stuck with a 2S3P setup (sucks). I've been looking for a 450VOC charge controller but they are pretty much geared for 48V battery banks. Then I found this unit online. I'm really interested to know about your real life experience with this unit...reliability, etc. It's really inexpensive (IMO) so I'm wondering about quality. What do you think about using it as a solar charger only? (backup inverter) Thanks for your video!
@JustinsProject
@JustinsProject 9 месяцев назад
I think it would be great as a solar charger only! That is what I will do with it once I get my mini splits in. Thanks for watching and commenting 👍🏻
@kimmogensen5390
@kimmogensen5390 8 месяцев назад
i have been running a 24v 3kw unit for almost a year now , i have 5 505w panels in series connected to it ,,spring summer fall its a powerhouse , altough a bit noisey. in the winter here in skandinavia i find that its hunting a bit to much for the powerpoint charging stopping charging stopping (it could be that i just have to few panels in series 250v )and they like to stabilize around 220-190v under load and it dip under that when it start charging ,,all in all i am very impressed with this unit and the funtions it have for the very low prize gen or grid input bypass powering e,c,t as it cont the same as a decent inverter alone ,,i can recommend..
@Karlosr6
@Karlosr6 8 месяцев назад
you can control at what voltage it should switch from the battery to the power grid and at what voltage it should switch back to the batteries
@JustinsProject
@JustinsProject 8 месяцев назад
Thanks for watching and commenting 👍🏻
@DahStratMode3
@DahStratMode3 2 месяца назад
Hi mate. I have powmr 3.2 24v hybrid inverter and my question is in the Philippines we have 220v on our socket via grid. and Do I need a 12v converter if I will use gadgets with only 12v and below? or It is safe to use the 24v powmr system to 12v gadgets without 12v converters?
@JustinsProject
@JustinsProject 29 дней назад
Do not try to power 12v appliances with 24v outputs. It will cause damage to the appliances.
@grantmidd
@grantmidd 3 месяца назад
There are many versions of this inverter on the market. What I couldn't find out is if it could bypass straight from the grid to the appliance. Dose this mean you don't actually need a battery? I want to set this up for my 2kwh hottie heater and make it as cheap as possible. My hot tub cost £1k a year to run and adding a 3kwh solar array will definitely take that price down. In the uk I can build this for £700 including the pannals. But if I can save money by not buying battery it would save me £1.3k. Please advise me.
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@fjayw
@fjayw 3 месяца назад
Does this all-in-one have the generator hook up to run a generator say for an ac window unit on a small off grid solar system setup?
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@lmeraz72
@lmeraz72 2 месяца назад
Yes it does
@johgude5045
@johgude5045 10 месяцев назад
Idle Power consumption from the batteries would be very useful. Many of these units eat 50Watt when sitting around during night time, draining the battery. Espacially during winter they eat more than PV produces. Victron Multiplus 2 only needs 8 Watts during idle, they are much more expensive though
@JustinsProject
@JustinsProject 10 месяцев назад
You are right, I should have provided that. Next time, I have it wired up I will add that info to the comments. Thanks for watching and commenting 👍🏻
@jab376
@jab376 8 месяцев назад
Johguide5045. Oh yes, yes, yes i read that. Alot of powmr inverters are power zombies to extreme. They drain anywhere between 35 watts and 50 watts from battery bank, just sitting, with no load. Thats alot, people. Customers need to know that. That alone made me want to shop around and keep looking.
@johgude5045
@johgude5045 8 месяцев назад
@@jab376 you get a multiplus 2 3000 for 500 bucks nowadays. 2 years ago it was over 1000
@2hotscottpro
@2hotscottpro 7 месяцев назад
@@johgude5045where? I’m seeing $1350’ish for Victron
@johgude5045
@johgude5045 7 месяцев назад
@@2hotscottpro here in Germany it is 530€ ATM. I would recommend Panda Solar even if it is a bit more expensive there
@ixioniste
@ixioniste 3 месяца назад
hello, the inverter 10.2kw pow mr stil work without battery and without ac in? (only pv powered)?
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@willw7743
@willw7743 Месяц назад
No
@TomBate-fz3cc
@TomBate-fz3cc 3 месяца назад
I have PowMr3000 connected through a connecticut electric transfer switch, I am unsure how to earth this unit. your instructions appear to be a separate earth, the Pow Mr video says ground as close as possible to the unit.Can you advise please
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@xiaofang5096
@xiaofang5096 4 месяца назад
Thanks for this explanation. I need to know the quality and durability of this powmr before buying this. Can you help me with this?
@JustinsProject
@JustinsProject 4 месяца назад
From the test I conducted, it functions as it should.
@lucienrobinson685
@lucienrobinson685 3 месяца назад
I had the 2.4 kW version it didn't last long and had no built-in fuse
@xiaofang5096
@xiaofang5096 3 месяца назад
@@lucienrobinson685 For just a test they all function as they should. but if a test means having it for your personal use, then how long they last is a real question. thanks a lot for your review.
@xiaofang5096
@xiaofang5096 3 месяца назад
@@lucienrobinson685 thank you so much for sharing your experience.
@thedampestcrib6004
@thedampestcrib6004 10 месяцев назад
So the ground to the sub box comes from the ac in right? If thats so am i ok just grounding the solar panels to earth ground? 8ft rod
@thedampestcrib6004
@thedampestcrib6004 10 месяцев назад
As I hit send you answered it in vid lol but would solar panel cases be ok on own ground
@JustinsProject
@JustinsProject 10 месяцев назад
It really depends on the design, whether you need an earth ground rod or not. For example, my 10kw system only needed an equipment ground ran from the racking to the combiner box. Then, I ran directly to the main service panel. In some cases, if you ground to the earth, you could create a ground loop. You don't want that. In other designs, you would be required to earth ground the racking system. I know that doesn't help much, but without physically reviewing the electrical system, I don't know. Maybe post your question over on the diysolarbuilds.com forum. As we grow, maybe an electrical engineer will see it and answer.
@thedampestcrib6004
@thedampestcrib6004 10 месяцев назад
@DIYSolarBuilds the solar panels should be fine on ground that's for static and electric strikes. I suppose if I plugged the ac in it would cause ground loop if I kept it off then no. It's just the issue is there's no sub box near by and main botlx is in seperate house
@thedampestcrib6004
@thedampestcrib6004 10 месяцев назад
@DIYSolarBuilds ok did more research I'm going to ground the panels to combiner for electrical and staic. On the inverter would I be fine with ground from an outlet. But do you know if the ground on ac out is combined internally with ac in or should I bus bar those 2 ? I'm trying to do the same thing you did but that model doesn't have the ac out ground so ig that ones internal
@pissedoffpuppy
@pissedoffpuppy Месяц назад
What would happen if you plugged a micro inverter into a power station 120ac output to power it?
@JustinsProject
@JustinsProject Месяц назад
I haven't tried it, but it might be something I will experiment with in the future. 😉 Thanks for watching and commenting!
@emersonyepez1326
@emersonyepez1326 3 месяца назад
Hola una cónsulta en la etiqueta dice que la entrada de voltaje mppt es de 120 a 400v. Eso quiere decir que si solo tengo 2 paneles solares de 24voltios que en serie entregan 62 voltios el cargador solar no me funcionara por el poco voltaje?
@JustinsProject
@JustinsProject 2 месяца назад
You will need enough voltage to wake up the MPPT.
@jeffreysanico9452
@jeffreysanico9452 7 месяцев назад
what type of battery did you used sir
@JustinsProject
@JustinsProject 7 месяцев назад
This is the exact battery I was using: amzn.to/3NR3eot - I also have a review on that battery that can be found here: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-3rVQQvVdfD8.html - Hope that helps. Thanks for watching and commenting! 👍
@michellenite5393
@michellenite5393 2 месяца назад
Can I connect 2 inverters? I need more power than 3000W. Thank you
@JustinsProject
@JustinsProject 29 дней назад
Just to confirm your setup, check out PowMR website and locate the product manual to insure it will do everything you need. Thanks for watching and commenting
@tribalncgaming1091
@tribalncgaming1091 9 месяцев назад
i just sent back my chin's 3000w as the AC did NOT charge the battery.. remained 0a .. so will probably be buying powMR after i return the chins.
@JustinsProject
@JustinsProject 9 месяцев назад
Hopefully, you get that all worked out. Good luck. Thanks for watching and commenting 👍🏻
@tracydjenkins
@tracydjenkins 9 месяцев назад
I'm going through that now it's doing the same thing I luckily bought insurance on it .
@tribalncgaming1091
@tribalncgaming1091 9 месяцев назад
@@tracydjenkins I just got the powmr yesterday and set it up in a test bench.. works GREAT.. i run 2x 200ah lifep04 in series with a 60amp breaker to it.. AC power in with a 20amp 3 prong cord, put the 20amp outlets on it.. my only concern is its charging the batteries at 40amps.. and the grid power cable is getting slightly warm, wonder if there is a way to lower the amp charge to 20?
@logun1970
@logun1970 6 дней назад
How is this inverter doing from a "long term ownership" perspective? I've seen this unit on Amazon, just wasn't sure about long term or should I look more at Growatt or MPP brands?
@JustinsProject
@JustinsProject 6 дней назад
Depending on your budget and overall build, I was recommended to look into EG4.
@logun1970
@logun1970 6 дней назад
@@JustinsProject problem is I can't find a 3000w 24v EG4... Not really wanting to go to 48v just yet...
@JustinsProject
@JustinsProject 6 дней назад
@@logun1970 Ahhh, I see. I don't use the PowMR that often but it definitely does the job.
@marcbolan5265
@marcbolan5265 2 месяца назад
so is the powmr still going? Im thinking of purchasing one
@JustinsProject
@JustinsProject 2 месяца назад
Yes. Thanks for watching and commenting 👍🏻
@genemitra
@genemitra 3 месяца назад
how is your PowMr working today?
@JustinsProject
@JustinsProject 3 месяца назад
I use it from time to time. It is still working fine. Thanks for watching and commenting 👍🏻
@7rb943
@7rb943 3 месяца назад
Can two solar panal start the system??
@emersonyepez1326
@emersonyepez1326 3 месяца назад
Hola yo tengo la misma duda si solo tengo 2 paneles que en total entregan 62 voltios esto iniciará la carga porque la etiqueta dice de 120 a 400v ???
@JustinsProject
@JustinsProject 2 месяца назад
Thanks for watching and commenting 👍🏻
@VanlilfewithDaleandBailey
@VanlilfewithDaleandBailey 3 месяца назад
?Ok so it's an all in one inverter, but what about 12 volt power? What if it's a 48 volt system and you need to power your air conditioner? How about power for USB ports? I'm new to this but I don't understand how you can say it's all in one system when you need the other power sources?
@JustinsProject
@JustinsProject 3 месяца назад
All in one, meaning you don't need to purchase multiple components. Like a solar charge controller and inverter. It is a combo unit. Depending on your system, 12v, 24v, 36v, or 48v, you need to purchase the right one. Thanks for watching and commenting 👍🏻
@MrJRsung
@MrJRsung 3 месяца назад
I install this inverter but when i connect the pv don't charge the battery
@JustinsProject
@JustinsProject 3 месяца назад
It should. I would contact support and have them walk you through the setup for your configuration. Thanks for watching and commenting 👍🏻
@tstatus1206
@tstatus1206 2 месяца назад
whats the standby draw tho?
@JustinsProject
@JustinsProject 29 дней назад
I will need to test again to confirm. Thanks for watching and commenting
@dashley2525
@dashley2525 5 месяцев назад
Can anybody tell me of an electronics shop that can fix hybrid inverters like the PowMr 10.2?
@JustinsProject
@JustinsProject 5 месяцев назад
Depending on how old your unit is, you might check the manufactures warranty. Might be covered.
@dashley2525
@dashley2525 5 месяцев назад
It is new and they refuse to help get it worked on. PowMr tech is no good. They will never recognize a claim. They deny all responsibility and even claim there is no problem and told me they were done with it.@@JustinsProject
@Glidedon
@Glidedon 5 месяцев назад
Be sure your battery can handle 80 amps of charging, it's adjustable in the settings.
@JustinsProject
@JustinsProject 5 месяцев назад
True. Thanks for watching and commenting 👍🏻
@sandrapetretich7045
@sandrapetretich7045 5 месяцев назад
How do you work out if your battery can handle 80amps of charging? I am off grid (PV run only) and have 2 x 12V/250 amp gel batteries (set up in series)
@Glidedon
@Glidedon 5 месяцев назад
@@sandrapetretich7045 There should be a recommended charge current in your battery specifications / owners manual or search for AGM charge current.
@mikemcdonald5147
@mikemcdonald5147 9 месяцев назад
so I don't understand.........why is there ac from the house coming into the solar inverter? wouldn't you want SOLAR coming into the solar inverter? im very confused and new so trying to understand LOl
@JustinsProject
@JustinsProject 9 месяцев назад
The AC coming in can help charge the batteries if that is needed. Typically, you would let the PV array charge the batteries. However, it is useful to have an alternative charging option. Thanks for watching and commenting 👍🏻
@mikemcdonald5147
@mikemcdonald5147 9 месяцев назад
hey thanks for the clarification. OK so it's just a backup charging setup while you have power and when you don't it switches back to solar. Makes sense now. Thank you for your video and quick response.@@JustinsProject
@gabaradama144k9
@gabaradama144k9 7 месяцев назад
To get 240 V doesn’t the phases have to be separate 180°
@JustinsProject
@JustinsProject 7 месяцев назад
120V on each phase. Thanks for watching and commenting 👍🏻
@thedampestcrib6004
@thedampestcrib6004 10 месяцев назад
Also wouldnt you put 200a fuse to batteries?
@JustinsProject
@JustinsProject 10 месяцев назад
If this was a permanent setup then, yes I would have. Thanks for pointing that out, though. I should have mentioned that. Thanks for watching and commenting 👍🏻
@marineni0
@marineni0 10 месяцев назад
A step drill bit will fix that knockout not fitting
@JustinsProject
@JustinsProject 10 месяцев назад
Good tip. I have one and didn't even think about trying that. Thanks for watching and commenting 👍🏻
@stevezark2152
@stevezark2152 7 месяцев назад
40amp charging the batteries but the amp wiring and ac receptacle is 20amps. Hmm sounds like going to pop that breaker. Don’t you need to lower the ac charge input to under 20amps?
@randycarston986
@randycarston986 7 месяцев назад
That's charging at 40amps DC. That's only taking about 8 amps of the ac input. I have the same unit
@JustinsProject
@JustinsProject 7 месяцев назад
Thanks for watching and commenting 👍🏻
@fernowtoo
@fernowtoo 8 месяцев назад
Not sure the bonding setup is correct. Unlike a true sub-panel the source is the inverter, not your main AC panel. Electricity wants to get back to the source. If a hot wire suppled by the inverter touched the metal box it could not get back to the source through the breaker the way you have it. The AC IN is grounded to the inverter so if the black wire touched the inverter case it would trip the breaker that supplies the input. But then again I could be wrong. I think the load center supplied by the inverter should be bonded.,
@JustinsProject
@JustinsProject 8 месяцев назад
Something I will research a further. Thanks for watching and commenting 👍🏻
@user-os4dd1xf3k
@user-os4dd1xf3k 4 месяца назад
Did you ever get to determine if the neutral bond from your main grid panel is sufficient, or do you need to bond the panel connected to the inverter?
@fernowtoo
@fernowtoo 4 месяца назад
@@user-os4dd1xf3k From what I can tell, you do NOT bond the load center. When connected to grid power the inverter is bypassed and the main panel ground is primary as in any other sub panel. You do connect the green grounding wire to the inverter ground/green terminal providing the ground when the inverter is in use. Still not entirely clear to me how bonding is achieved if “grid power” is coming from a generator rather than the main power utility.
@fernowtoo
@fernowtoo 4 месяца назад
@@user-os4dd1xf3k Also, when I say ground I really mean “alternate return path” since it really has nothing to do with the ground we walk on. The green wires are an alternate return path to trip the breaker if the hot wire touches something metal that doesn’t have a white wire. Whatever.
@ramhammer10-4
@ramhammer10-4 Месяц назад
Ebay has these for 300 bucks.
@JustinsProject
@JustinsProject Месяц назад
Awesome! Thanks for sharing!
@sattiodibo2598
@sattiodibo2598 6 месяцев назад
This may be a wrong ground wiring. Why don’t you use your multimeter to check the voltage between neutral and ground. Let’s see what voltage is there? If it’s correct then Neutral and ground should be 0-5 volts. The reason it’s wrong is where did you get your ground that is going to the ac outlet. This maybe dangerous please test with your multimeter
@JustinsProject
@JustinsProject 6 месяцев назад
I'll check it the next time I have this configuration installed. Thanks for watching and commenting 👍🏻
@jegi8202
@jegi8202 2 месяца назад
You are correct. When measuring between the ground and L, and Ground and N at the controller, it is 60 VAC from Ground to L and to N. Both the L and N are floating from ground. They are taking the 24 VDC from the batteries and creating 2 out of phase 60 volt waveforms.
Далее
Upgrading Our Solar All-In-One Inverter by PowMR
21:35
Вопрос Ребром - Субо
49:41
Просмотров 1,6 млн
БИМ БАМ БУМ💥
00:14
Просмотров 3,6 млн
Every Victron Inverter/Charger COMPARED!
13:52
Просмотров 94 тыс.
If Your Portable Power Station Was On PowMr Steroids
8:19
Power Grid Failure? Prep to Survive! SunGoldPower
45:46
How Many Batteries For a 3000W Inverter?
6:09
Просмотров 826 тыс.
😳РЫБАК УДИВИЛ ПРОХОЖИХ!
0:12
Просмотров 1,1 млн
🤣🤣🤣🤣🤣🤣🤣
0:13
Просмотров 2,7 млн
WORLD'S SHORTEST WOMAN
0:58
Просмотров 80 млн
МОЖЕТ ЛИ УКУСИТЬ СОБАКА
0:14
Просмотров 3,8 млн