Hi Naki! Thank you very much for making such useful videos on PV system. However, I wish you could make a video of complete PV system, i.e. right from starting with solar panels, then Boost Converter, then MPPT, then 3 phase inverter, then transformer and finally the grid. I need complete design and Simulation Sir. Plz Plz Plz help me!!!
Hi Naki, you see the inverter voltage is more than 500Vac. Isn't like to be 310V for our grid. Also the PV voltage is more than 900V. Isn't like to be 812V in this arrangement? Please answer.
Hocam merhaba ben kaynak gerilimini değiştirdiğim modulasyon indexi değişmiyor değişsse bile çok geç tepki veriyor nasıl düzeltebilirim teşekkür ederim.
Hi sir, Thank you for the video, I used the controller to simulate the impact of charging EV on a distribution grid, can you tell me where can i find the reference for the control block?
Merhaba hocam. Bir mikrosebekenin hem adalı(en basitinden belirli bir zaman sonra anahtari acarak sebekeden ayirabildigimiz) hem de sebeke modlu calisma orneginiz ya da bir kaynak onerir misiniz? Benim mikrosebeke uygulamam sebeke modunda stabil ama sebekeden ayirinca ada. Modunda hic guc üretmiyor.
Merhaba, bununla ilgili Düzce Üniversitesi Dergisinde bir makalem var ancak henüz basım aşamasında. Basıldığında paylaşabilirim yada takip edebilirsiniz. İyi çalışmalar
Did you try to change 380 to 415 in reference voltage? So, the reference voltage should be 415*sqrt(2). You should change the load voltages. You may need to change PI parameters. But, please try to changes step by step.
İyi günler Naki hocam. Matlapta ödevim var. Rüzgar ve güneş santralından oluşan hibrit santral çizerek üretien enerji akülerde depolanacak akülerin şarj deşarj durumları kontrol edilerek enerji yönetimi simülasyonunu yapacağım matlapta nasıl yapabilirim. Yardımınız için teşekkürler.
İyi günler, söylediğiniz durumlar için temel bir yönetim algoritması gerekli. Burada birçok parametreyi göz önünde bulundurmanız gerekebilir, rüzgar üretimi var mı, güneş var mı, bataryalar boş mu dolu mu..... diye gider. Çok karmaşık bir yapı çıkar ki kontrolü de ayrı bir beladır maalesef. Eğer bunları oluşturma yöntemi soruyorsanız, matlab function bloğu var kod yazılabiliyor o daha kolay olacaktır. Kolaylıklar dilerim.
@@nakiguler Dediğiniz gibi hocam ödevde senaryolar oluşturdum. Senaryo 1: Üretilen enerji tüketimden fazla ise depolama birimine fazla elektrik enerjisi gönderilerek depolanır. Senaryo 2: Tüketimin üretimden fazla olduğu zamanlarda hibrit sistemle üretilen ve depolanan elektriğin birlikte tüketiciye elektrik verilerek enerji sürekliliği sağlanmış olur. Senaryo 3: Tüketimin puant saat zamanında üretimin tüketimi karşılamadığı zamanlarda depolanan enerji ve üretilen enerjiden tüketicinin elektrik ihtiyacı karşılanmış olur. Senaryo 4: Hibrit enerji sistemleri bileşenlerinden rüzgarın veya güneşin olmadığı zamanlarda tüketicinin enerji ihtiyacı sistemin ürettiği elektrikten fazla ise depolanan enerjiden ve sistemden üretilen enerjiden karşılanmaya çalışılır. Senaryo 5: Hibrit enerji sistemleri bileşenlerinden rüzgarın veya güneşin olmadığı zamanlarda tüketicinin enerji ihtiyacı sistemin ürettiği elektrikten az ise sadece üretilen enerjiden karşılanmaya çalışılır. Bir diğer kontrol birimi olan akülerde, Akülerin şarj ve deşarj durumlarına bakılarak: Akülerin aşırı şarj ve deşarj olması engellenecektir. Akülerin güvenli çalışma bölgesinde çalışması sağlanacaktır. ödevim bu şekilde Naki hocam sizden ricam bununla ilğili bir video paylaşabilir misiniz? matlapla ilğili bilğim çok az. Yardımınız için çok teşekkür ederim.
Hello sir! I tried replacing PI with Fuzzy. But I stucked with 128 errors, and I think all of them stick around the error "FOUND ALGEBRAIC LOOP". Could you please help me out with this sir. Thanks in advance sir. And sorry, I tried altering your work without permission.🙂
Sir please create fault (LL fault, ground fault) in a PV system. Sir I am your big fan from my heart. I don't miss your any video. I commented you many times for this matter. But you don't give any relpy. Please sir
Zeeshan Akhtar I have two paper that related with grid connected inverters, you can find it in my official web site (websitem.gazi.edu.tr/site/gulern/academic) : 1. Guler Naki, Irmak Erdal (2019). Design and Control of Multi - Input Multi - Output DC-DC Converter for Neutral Point Clamped Inverters. Gazi University Journal of Science Part:C, 7(49-62). 2. Erdal Irmak, Naki Güler, 2018. Model Predictive Control of Grid-Tied Three Level Neutral Point Clamped Inverter Integrated with a Double Layer Multi-Input Single-Output DC/DC Converter, IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering~IEEE CPE-POWERENG'2018, Doha, Qatar, 10-12 April 2018.
Zeeshan Akhtar, Because of the paper is in the Turkish language. You can find it below. Guler Naki, Irmak Erdal (2019). Nötr Kenetlemeli Eviriciler için Çok Giriş - Çok Çıkışlı DA-DA Çevirici Tasarımı ve Kontrolü. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 7(49-62). doi.org/10.29109/gujsc.490144
My project is on grid connected pv system and I am using a hysteresis controller for the inverter and a MPPT for boost, but my boost converter is not working, whatever is the input the output is same, anyone has any idea what the problem might be.
If the load is inductive type q part will appear. How can we maintain the voltage at that time.? Can we use the source inverter as compensator too? Can you help me?
It will affect the current. The control method working based on voltage. It will not affect from the inductive load. But, it may require a new filter design.
@@nakiguler Thank you for responding. That mean the current Iabc should pass through a low pass filter. Can you pls respond? I was observing that with 10KW 2 kVar load voltage mag is maintained but I am getting less smoothness at maximum and minimum point of voltage responses. If you can explain it will much appreciated.
@@extendedclassroom5795 , I mean, the output filter of the inverter may change. Because the load changes the system dynamics. If you design a new filter, you may obtain better results. For ex., could you please multiply the Cfmax value by 0.75(75%).
Actually, its procedure will be same as this one. You may only have a problem for dq0 calculation part. You may use RMS calculation, but its implementation is hard for real systems.
Hai sir can you please make ppt on shunt active power filter application in grid tied solar photovoltaic system by droop control strategy for presentation
I have no experience with H6 inverters. But you may check my other video for grid connection. You may replace H6 to 3 phase inverter. It may help you. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-WKw8DMMjGp0.html
@@nakiguler ,sir do you have any module on pv night mode operation, that is reactive power compensation at the grid side to maintain power factor equivalent to unity....?
I have 2 papers about it. These are not directly related, but you may find some critical points. Second one in Turkish. 1- N. Güler and E. Irmak, "MPPT Based Model Predictive Control of Grid Connected Inverter for PV Systems," 2019 8th International Conference on Renewable Energy Research and Applications (ICRERA), Brasov, Romania, 2019, pp. 982-986. 2- Guler Naki, Irmak Erdal (2019). Nötr Kenetlemeli Eviriciler için Çok Giriş - Çok Çıkışlı DA-DA Çevirici Tasarımı ve Kontrolü. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 7(49-62).
d parameter of the ABC to dq transform gives peak value of the voltage. The transform uses phase angle for calculations. Because of that PLL is used to obtain wt.
I have two paper that related with grid connected inverters, you can find it in my official web site (websitem.gazi.edu.tr/site/gulern/academic) : 1. Guler Naki, Irmak Erdal (2019). Design and Control of Multi - Input Multi - Output DC-DC Converter for Neutral Point Clamped Inverters. Gazi University Journal of Science Part:C, 7(49-62). 2. Erdal Irmak, Naki Güler, 2018. Model Predictive Control of Grid-Tied Three Level Neutral Point Clamped Inverter Integrated with a Double Layer Multi-Input Single-Output DC/DC Converter, IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering~IEEE CPE-POWERENG'2018, Doha, Qatar, 10-12 April 2018.
Thanks for this video. I designed this simulation with your steps and it works properly. Could you please share your e-mail id so i can clear my doubts. Thanks again...