Powering My ENTIRE House with Champion Inverter Generator. 

JCT FIX IT
Подписаться 4,1 тыс.
Просмотров 34 тыс.
50% 1

In this video I show you how to safely power your house with a generator without the need for spending money and wiring in a transfer switch.
Square D Homeline Mechanical Interlock Device: amzn.to/3tCun2c
Champion Inverter Generator: amzn.to/3x9YKiH
Champion Inverter Generator with 25ft 4 Prong Cord: amzn.to/32ybbqs
25 Foot 4 Prong Extension Cord: amzn.to/3ejFHK7
Generator Inlet Outlet Box: amzn.to/3gs9xyW
As an Amazon Associate I earn from qualifying purchases made using my amazon links.
Disclaimer: The information presented is not intended as professional advice. JCT FIX IT assumes no liability for any damage to property or physical injury as a result of using information contained in this video. Due to constraints outside the control of JCT FIX IT there will be no warranties expressed or implied given in regards to the information contained in this video. Do work at your own risk. Any property damages or injuries incurred via use of information from this video are the responsibility of the viewer and not JCT FIX IT.

Опубликовано:

 

4 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 98   
@SP-wk1en
@SP-wk1en Год назад
The green indicator light is cool. Never seen that before. Thanks for the video.
@JCTFIXIT
@JCTFIXIT Год назад
Ya nice to have power indication.
@antwonjamal
@antwonjamal 3 года назад
JCT Fix It coming in hot with the generator tips, always on point.
@JCTFIXIT
@JCTFIXIT 3 года назад
Thanks!
@electriccuts
@electriccuts 2 года назад
I have the Predator version of this generator. It works great. I am able to run almost everything in my house. The 240 volt loads are the ones that I need to be aware of.
@tacx1
@tacx1 Год назад
As an electrician, thanks for showing people the safe way so that linemen do not get killed. ALSO, Did you confirm if your generator has a “floating neutral” ( neutral and ground are separate in the gen) or a “ bonded neutral” ( neutral and ground are connected in the gen ) ?? When you connect your gen to your house system, you need to separate the neutral and ground in the generator. The reason is because when connecting the gen to your home you have created ONE system. Per code, you can only have one ground per system.
@JCTFIXIT
@JCTFIXIT Год назад
My generator does have a bonded neutral but I disconnected it so it is now floating for this purpose
@nervouswreck392
@nervouswreck392 Год назад
​@@JCTFIXITplz explain this further. I'm trying to understand what you said about the ground thing. I back feed through my dryer plug but if I turn anything on 120 wise like a light it blows it out. Like to much power⁉️ why is that⁉️
@JCTFIXIT
@JCTFIXIT Год назад
Sounds like you are not hooked up right. Side note: Lookup floating vs bonded neutral on Google.
@user-ui4iv8dz3w
@user-ui4iv8dz3w 10 месяцев назад
All that is code mumbo jumbo. Your using a generator because it’s a emergency situation. Codes be damned. You do what you gotta do, to keep the power on. Worse comes to worse you can ground your genie to the grounding rod of the house.
@gmsgabaradama2009
@gmsgabaradama2009 9 месяцев назад
@@user-ui4iv8dz3wno bad info you must run your generator unbonded to ground and do the proper install for your house panel or else you’re getting ready to kill somebody maybe even yourself
@Liledgy100
@Liledgy100 2 года назад
As a line man, thank you!
@JCTFIXIT
@JCTFIXIT 2 года назад
Seriously could be spooky when people backfeed the grid
@bubbatime
@bubbatime 2 года назад
Connect your power cable to the generator and the house, BEFORE starting it. That's 240V with 30 amps, enough to kill. Don't handle the connections on a running generator.
@JCTFIXIT
@JCTFIXIT 2 года назад
A lot less than that will kill you, but it's also not a good idea to try to start a generator with a load on it. You can safely plug into a generator. You do it on the walls of your house everyday.
@MichaelBrown-xb6pp
@MichaelBrown-xb6pp 2 года назад
@@JCTFIXIT Always connect the cord first before starting generator. The plugs in your house do not have hot extended leads like the generator cord. It also properly grounds the generator before you start it for safety and there won’t be any loads on it due to your interlock kit. Also make sure you float the neutral in your generator because there should only be 1 bonded neutral in a system and that will come from your distribution panel. I’m considering this generator for clean power for my sensitive electronics in my house. Do you find that your computers, dryer and refrigerators work properly on gen power? Thanks for posting the vid.
@JCTFIXIT
@JCTFIXIT 2 года назад
Yeah everything works great the one thing you do have to watch out for is making sure you are load balancing. You don't want all your load on only one side. So for example if you are running electric dryer on one side it would be unwise to run microwave on same side. Make sure its on opposite side of split phase.
@duskyman1
@duskyman1 Год назад
@@MichaelBrown-xb6pp a generator cord doesn't have hot extended leads..... No extension cord does by design.... That's what a home made suicide cord has...And that is one of the reasons you should not do that. I know someone who's wife accidentally tried to use his suicide cord made for generator as an extension cord and got shocked. With a proper generator receptacle there is no issue. If you'll notice the plug is plugging in is a female and has nothing extended from it and they prongs in the receptacle in the wall are not energized......safe Personally I've never had any issue with electronics and my synchronous generator that has a AVR automatic voltage regulator. I think the need for inverters is mostly marketing here. I've been using my regular generator for 20+ years...... Several times I've run the house for a week and that includes Smart TVs routers computers with no issues.
@duskyman1
@duskyman1 Год назад
@@JCTFIXIT yep it's not the voltage, its the amps and it only takes 50 milliamps to kill you
@zone47
@zone47 Год назад
Good idea, I think I'll do the same. Thanks for sharing!
@JCTFIXIT
@JCTFIXIT Год назад
Git r done!
@nimrodpaul6875
@nimrodpaul6875 2 года назад
What gen u recommend to run small window ac , lights , fan, TV, and microwave, during power outages? I don't have or need the 240 but will be using cords for the 120. Any help appreciated, subbed, great vid
@JCTFIXIT
@JCTFIXIT 2 года назад
Depends on what kind of load your window ac pulls. Probably a 3500 inverter model would work well. Something like this: www.harborfreight.com/3500-watt-super-quiet-inverter-generator-with-co-secure-technology-59137.html
@duskyman1
@duskyman1 Год назад
First I wouldn't recommend anything harbor freight with only a 90 day warranty. I have a champion 3500 that I can run 2-8000 btu air conditioners, along with lights and TV ,refrigerator, freezer. In order to run the microwave or toaster oven we have to turn the air conditioners off
@Honestandtruth007
@Honestandtruth007 Год назад
Every Generator needs A Shed from Rain and snow and Also Reduced Noise Level as desired 😅
@JCTFIXIT
@JCTFIXIT Год назад
Stays in the garage. Only turn it on every few months just to ensure we are running good.
@terrytorres4518
@terrytorres4518 2 года назад
What does it cost to have an electrician install a generator interface on the power panel that will power your home like you have in this video? Just a rough idea. I am looking to purchase a Champion 9375. Great video, Thanks!
@JCTFIXIT
@JCTFIXIT 2 года назад
Hard to say. Really depends on how easily you can access your main breaker. With easy access I would think $300-$400 for labor + cost of parts and permits.
@JCTFIXIT
@JCTFIXIT 2 года назад
You could call and get a couple quotes.
@terrytorres4518
@terrytorres4518 2 года назад
@@JCTFIXIT Thank You, appreciate the info
@kylesturdivant3751
@kylesturdivant3751 2 года назад
Should cost no more than $450. it is simple to do.
@duskyman1
@duskyman1 Год назад
That depends a lot on your current panels. It depends a lot on what you have is up to code or not. When an actual electrician pulls a permit and goes into make some changes he may have to bring some older things up to current codes. This can add a lot of cost. It also depends on your panels and if you can put a simple interlock on there or not. If you can, full retail you're probably looking at $150 for the interlock, $30 for a 30 amp generator breaker, $50 for the receptacle, $25 for miscellaneous conduit fittings, $20 for some wire. Then probably about 3 hours of a electrician's time. So a rough estimate would be $450. Of course you can do this yourself for only the cost of the parts if it's that easy. My service panel has no main breaker. So I had to put a interrupt panel in between my service panel and my house which only allows me to attach the generator to the house panel. So mine will not run my big amp items like AC stove water heater or furnace. Those had their own breakers in the service panel by the meter. That's okay because I have small window unit ACS I put in after a storm if the power is out for a few days they use a lot less energy than the big Central AC. Being able to use the water heater or limited use of the stove would be nice but I've always gotten by with just microwave and a toaster oven. And cold showers. I could put in a big 200 amp transfer panel between the meter and the house panel to solve my problem.... Or just replace the whole service panel with one with a main disconnect breaker. That would probably be the easiest and I got a price on that and it was not a nice price.......$3700. when they do this they have to bring things up to code, they do not want to reuse old breakers they want to use all new, etc. Plus they've got to get a permit and an inspection etc etc. They charge for all the time that it requires from them by the hour. So in the end I put in my panel myself for about $400 total. This is why so many people will just flip their breaker and use a suicide cord and plug into their dryer socket. That cost $50, and you're really doing the same thing you just don't have the idiot proof interlock. However after running extension cords through doors for years I was sick of extension cords and that was my main reason for going ahead and putting in the generator receptacle and transfer panel outside to basically power what I needed in the house. Turn on whatever light you want instead of just a few lamps. Run ceiling fans instead of just floor fan. Don't have to pull the refrigerator and microwave out so you can have them plugged in to extension cords etc. That was all a royal p i t a. It is well worth whatever it costs imo for ease. It took me many years and several episodes without power for a few days to do mine because I just knew mine wasn't simple. There was really only one company that made the kind of transfer panel I needed and that was reliance panel link
@dsmith2858
@dsmith2858 Месяц назад
Can you run everything to include Furnace and AC?
@JCTFIXIT
@JCTFIXIT Месяц назад
Yes. But it all depends on how efficient your equipment is and what kind of power it draws. everybody is a little bit different.
@shenmisheshou7002
@shenmisheshou7002 2 года назад
The 6250 will run ALMOST everything in most houses that have gas appliances. What the 6250 will not run is most residential AC units. The 6250 will not deliver the locked rotor amperage necessary to run anything over about a 2 ton AC. I use the interlock too, and I love it. I can run the central heat, but not the central air.
@JCTFIXIT
@JCTFIXIT 2 года назад
My AC compressor runs no problems. I imagine some of the older and/or bigger units could be problematic.
@shenmisheshou7002
@shenmisheshou7002 2 года назад
My guess is your AC is a smaller unit. The 6250 won't deliver nearly enough current to start my 3.5 ton unit. The locked rotor amperage of the unit is 108 amps and the Champion 6250 is only rated at 52 amps (26 amps over each leg of a 240 volt circuit) and based on the typical LRA of a 3 ton unit, it would probably trip off for most of them.. But maybe not. I know it won't start mine and a 100 amp LRA is pretty typical of a 3.5 ton unit and 75 LRA is typical of most 3 ton units.
@sony1998
@sony1998 2 года назад
@@shenmisheshou7002 Any drawbacks to using a soft start on the A/C?
@shenmisheshou7002
@shenmisheshou7002 2 года назад
@@sony1998 I think it would clearly help but hard start kits are very hard on motor windings. I am considering a soft start kit though. These are much more expensive , but I think they are perhaps a better approach. This would reduce the startup current by about 60% so for my unit, this might be enough to start it. LRA is a bit more than 100 amps and the 6250 will put out a peak of 52 amps, but that is cutting it close. It would cost me about $300 to find out though.
@shenmisheshou7002
@shenmisheshou7002 2 года назад
@@sony1998 In addition to the response I just put up, people also forget about the inrush current on the evaporator blower motor. My unit starts the compressor first and when the pressure at the evaporator is sufficient it turns on the fan, but this fan draws about 1400 watts on startup and I think about 800 watts run. This totals out to a lot of current for a small generator. My primary concern was heat during prolonged power outages in the winter where the power can take hours to be restored (4 hours day before yesterday). In the summer we sometimes have outages but these are usually no more than 90 minutes.
@ZezimaTruth
@ZezimaTruth Год назад
That's pretty cool
@JCTFIXIT
@JCTFIXIT Год назад
Thanks.
@notchit3542
@notchit3542 Год назад
I thought it has quiet technology, seems pretty loud. How do you like it? Thanks
@JCTFIXIT
@JCTFIXIT Год назад
It's good. The ones that are quiet usually have a built-in plastic cage and absorption for Acoustics this one not so much although the engine speed can vary because it is an inverter
@notchit3542
@notchit3542 Год назад
@@JCTFIXIT That's good to know. I just order the 6250 inverter today & I'm gonna build a quiet box for it. Thanks for sharing 👍
@airborneranger-ret
@airborneranger-ret Месяц назад
Liked and subbed
@JCTFIXIT
@JCTFIXIT Месяц назад
Awesome thanks!
@michaelkavenagh752
@michaelkavenagh752 Год назад
Why is your hookup inside the garage rather than on the outside wall. Just curious.
@JCTFIXIT
@JCTFIXIT Год назад
I repurposed an outlet that was already existing.
@wildncrazyguytv
@wildncrazyguytv 2 года назад
Hello. I'm trying to get my materials together for the same model generator. I noticed you had a double 50 amp breaker. Is that the size I should use? I'm not savvy to electrical installation, for some reason I thought being as it was a 30amp plug that the cord is for the generator, a double 30amp breaker is what I needed. I have a jacuzzi plug outside with a heavy duty wire run to the panel. I was going to replace it with a generator outlet that you recommended. Thank you!
@JCTFIXIT
@JCTFIXIT 2 года назад
Make sure that the wiring is suited to your breaker. Most would recommend 10 gauge wire for a 30 amp breaker. I repurposed a 50 amp breaker that already had 6 gauge wiring to carry that load. As far as breaker, 30 amp should be sufficient as it should be able to handle over 7000 watts on 240v connection.
@wildncrazyguytv
@wildncrazyguytv 2 года назад
@@JCTFIXIT Thank you for the advice!
@wildncrazyguytv
@wildncrazyguytv 2 года назад
@@JCTFIXIT I believe my wire is 6 gauge, also. We were going to put a jacuzzi in while remodeling, but changed our minds.
@passion830217
@passion830217 8 месяцев назад
Using a 50 amp breaker for a 10 gauge wire is not ideal. Imagine there is a short or connection issue from the generator side, the 10 gauge wire may get warm or even catch on fire, but the breaker may not turn it off.
@lukebard7589
@lukebard7589 7 месяцев назад
Do you know if you can run this generator in parallel with another identical unit for more power?
@JCTFIXIT
@JCTFIXIT 7 месяцев назад
It's not designed with a parallel kit, that doesn't mean it couldn't be done, but I would just get a larger generator.
@nelly20utb
@nelly20utb 3 месяца назад
​@@JCTFIXITI bought the trifuel 15kw/12kw champion generator. Is not inverted. How can I clean the "dirty power" things I want to power are 4 ton a/c, large fridge, washer/dryer. Occasional gas furnace and small appliances, a few lights. I want to hook it up to natural gas. Most inverted generators from champion max out at 9kw but loose kw on natural gas.
@scottburton4236
@scottburton4236 5 месяцев назад
This seems loud for an inverter generator. What running watt generator is this?
@JCTFIXIT
@JCTFIXIT 5 месяцев назад
Many inverter generators have enclosures around them and thus are much quieter. This model is not enclosed like many inverters are.
@scottburton4236
@scottburton4236 5 месяцев назад
@@JCTFIXITGotcha. I understand now. Great video, BTW.
@JCTFIXIT
@JCTFIXIT 5 месяцев назад
Thanks! Thanks for reaching out.
@patterdalezipsuzilil
@patterdalezipsuzilil 16 дней назад
What about your ground spike from generator absolute muppet
@JCTFIXIT
@JCTFIXIT 16 дней назад
Why would I ground my generator if I am going to tie it to my home ground?
@CaptBill69
@CaptBill69 Год назад
Good to see economical way to hook up house without that extra gen to house kit. I would guess some folks might turn off some of the larger amp breakers at beginning to avoid all of them drawing generator electricity at the same time (if that was a combo that could overload the generator, which would just turn it off via it's own protection breakers) ... Thanks for Econ Model 🏊🚣⛵🎶🙂
@Dickj203
@Dickj203 Год назад
Does it run ac?
@JCTFIXIT
@JCTFIXIT Год назад
Depends on the AC unit. At my last house it would run the AC unit. I recently moved and it will not run the AC unit for my new house, so I'm going to have to get a soft start kit for it
@Dickj203
@Dickj203 Год назад
@@JCTFIXIT any issues with it so far? Stalling out? Fault light issues?
@JCTFIXIT
@JCTFIXIT Год назад
No I have not had any issues I'm so far granted I've only ran it for a few hours here and there
@Dickj203
@Dickj203 Год назад
@@JCTFIXIT what was your old ac that it ran? I have a heat pump/mini spit ac.
@JCTFIXIT
@JCTFIXIT Год назад
It was a traditional compressor. Mini splits are usually very efficient. It would likely run it no problems.
Далее
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Аруси Точики ❤️❤️❤️
00:13
Просмотров 92 тыс.
ПРОСТИ МЕНЯ, АСХАБ ТАМАЕВ
32:44
Просмотров 923 тыс.
Cheap vs. Expensive Generator (Surprising Results)
25:49
Running An Entire House On An Amazon Generator
15:01
Просмотров 342 тыс.
Powering My Home With A Wen 3800 Inverter Generator
7:17
Champion Generator THREE YEAR Review--Does It Suck?
11:29