Pre-Built Combi Boiler System with VT2218 and Zone valves 

Jim Speranza
Подписаться 5 тыс.
Просмотров 32 тыс.
50% 1

Contact me at speranzadevelopment@gmail.com for consulting on a heating system or if you would like me to build you a system.
venmo.com/code...
paypal.me/Speranzadevelopment@gmail.com
www.facebook.c...
www.instagram....
www.tiktok.com...
#boiler #boilers #navien #vt2218 ‎#radiant #combi #heating #hvac #plumbing #construction #home #house #renovation#renovating @NavienInc ‎@TacoHVACtv ‎@Supplyhouse

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 115   
@antoniorestrepo4299
@antoniorestrepo4299 9 дней назад
Hey Jim, thank you for posting these videos and sharing your knowledge. I have a question: What size are the inlet and outlet of the manifold and what type of adapter (reducer?) you use to connect to the supply and return. Second, If I were to build the manifold myself (pretty expensive I would say), what pipe diameter is the horizontal run? Thank you n advance for your time.
@JimSperanza
@JimSperanza 6 дней назад
@@antoniorestrepo4299 diameter is 1.5 inches. Pipe sizing depends on many factors. Email me at speranzadevelopment@gmail.com for consulting or a design.
@FrustratedBaboon
@FrustratedBaboon 8 месяцев назад
You don't make any sense to beginners. This video is useless for people trying to learn. I have a degree in Electrical Engineering and a degree in Thermodynamics and a degree in computer science. I don't understand anything you explained. Go and make fun of my coment.
@leonginorivera8309
@leonginorivera8309 7 месяцев назад
You have to charge 12,000 dollars , and not everybody wants to pay. Too fancy and expensive parts . But that's the way to do it if costomer like good quality.
@JimSperanza
@JimSperanza 7 месяцев назад
You get what you pay for! 😉
@onlyme972
@onlyme972 5 месяцев назад
Only if you need it, from the Uk it looks expensive overly complex, clunky and yesterdays tech.
@oelschlegel
@oelschlegel 2 месяца назад
What's a setup like this go for? Do you have any where the boiler does hot water (tap) heat as well?
@JimSperanza
@JimSperanza 2 месяца назад
Email me at speranzadevelopment@gmail.com and I can send you some info.
@moeelmunaier1640
@moeelmunaier1640 2 месяца назад
for the secondary piping are you using 1" or 1.25"?
@JimSperanza
@JimSperanza 2 месяца назад
@moeelmunaier1640 it depends on how many BTUs you are delivering to the secondary zones
@adamkern3689
@adamkern3689 8 месяцев назад
Well done. The one thing I have never liked about prefabbing boilers is, more often than not, they are assembled so compact that service on the unit will be next to impossible. You have have done a really good job of striking a great balance. The "next guy" shouldn't have any issue working on this.
@matthewwaring7134
@matthewwaring7134 Год назад
I would love to find some where I could get a three zone Navien NFB-175H boiler setup pre built like this!
@JimSperanza
@JimSperanza Год назад
You found it! Contact me speranzadevelopment @ gmail.com
@yassinekremo5159
@yassinekremo5159 8 месяцев назад
How much the hole thing cost for the part 3 zone
@JimSperanza
@JimSperanza 8 месяцев назад
Email me at speranzadevelopment@gmail.com for a quote
@joecypress11
@joecypress11 7 месяцев назад
You sent me your email address a couple weeks ago and I lost it. Can you send it again please?
@JimSperanza
@JimSperanza 7 месяцев назад
Speranzadevelopment@gmail.com
@joecypress11
@joecypress11 7 месяцев назад
Thanks
@BuddyNika
@BuddyNika 7 месяцев назад
It seems nobody wants to tell anybody how much they charge for this work, I can only guess why.
@JimSperanza
@JimSperanza 7 месяцев назад
Nobody is hiding anything. Email me for a quote. Pricing can range from $6k to 10k depending on BTU, how many zones, heat only vs. Combi.
@patrickg875
@patrickg875 Год назад
Great Job and Thankyou for posting this.
@JimSperanza
@JimSperanza Год назад
Thanks for watching!
@michaelisakov1108
@michaelisakov1108 6 месяцев назад
Can you do a video of a setup system and how to connect and fill water from main supply as well as how to bleed all the air from the system.
@Jessedog11
@Jessedog11 9 месяцев назад
where's the expansion tank?, is it built into the Navien?
@JimSperanza
@JimSperanza 9 месяцев назад
It will be connected to the bottom of the air eliminator. I ship it loose so I can slide the board into a pickup bed.
@jk6343
@jk6343 Год назад
what's your location?
@JimSperanza
@JimSperanza Год назад
Email me speranzadevelopment @ gmail.com
@henryvachon4591
@henryvachon4591 Год назад
Great video! This is the exact system I’m working on installing in my house. I was wondering though how to incorporate an outdoor wood burner into this setup.
@JimSperanza
@JimSperanza Год назад
You can use a heat exchanger to isolate the heat sources and switch over manually with shut off valves or use a controller to determine priority.
@PabloPayan-g5v
@PabloPayan-g5v 11 месяцев назад
Awesome video man!! Thank you. I could use your help sizing my old equipment to upgrade to something like this. Can we connect?
@JimSperanza
@JimSperanza 11 месяцев назад
Contact me at speranzadevelopment@gmail.com
@Agoattamer
@Agoattamer 8 месяцев назад
I've been in the commercial mechanical trade for almost 30 years. I'm more of the sheetmetal side instead of the plumbing. So I have no business critiquing any of your work. Looks awesome, actually! But boilers, especially these high efficiency condensating boilers just fascinate me. I've done a few, including a Noritz NRCB combi at my home. Awesome machine. I used taco zone valves and a 007-f5 circulator. I keep an extra zone valve and circulator for backup. Now 2 of my zones are baseboard and the 3rd does the basement hydronic fan coil. System works fine and it's into it's 3rd winter. Finally my question. I do not monitor temperature. I really don't know what the return temps are in respect to the supply. I have an outside air monitor to regulate boiler temperature. So would my system benefit from a circulator that uses pressure or ∆t to control flow? Would the cost of the pump actually pay off in the long run? Also, why don't you have a table? My knees and back hurt just watching you, lol
@JimSperanza
@JimSperanza 8 месяцев назад
Thanks for the compliments. You would definitely benefit from a Delta T pump. It will ensure you are not over or under driving the heat emitters depending on how many are open and also the load changing whebln the heat loss differs day by day. I did try using a table before and also mounting it on the wall but it's actually been much easier for me because the size and weight of all the parts. I can climb all over and around while I'm working.
@stevepailet8258
@stevepailet8258 8 месяцев назад
gsg your moving the camera around it made me feel queezy
@patrcrnn
@patrcrnn Год назад
Nice Pro Installation! Good Job explaining everything as well.
@paulglendenning6409
@paulglendenning6409 11 месяцев назад
another stupid question. The backing board you are using is 1/2" or 3/4" material?
@JimSperanza
@JimSperanza 11 месяцев назад
3/4
@gemheatingandairconditioning
@gemheatingandairconditioning 10 месяцев назад
That Navien manifold looks like some money!
@martinheatingcoolingmartin4693
Hi, I love the video. I do the same stuff with my own company. I’m not set though on what boiler I want to sell. I really like the Navien and I see you must too. Any opinions on using this boiler?
@JimSperanza
@JimSperanza Год назад
Personally I mainly use Navien because I've had minimal issues with them. Also by sticking with 1 manufacturer I really get to know the ins and outs of them and deliver a great product in the end.
@martinheatingcoolingmartin4693
Excellent, thank you for that response. I believe I’ll keep using Navien. I know their tech support is flawless.
@martinheatingcoolingmartin4693
The only thing was: Is the way I came to know Navien was only from service calls…really due to lack of maintenance.
@martinheatingcoolingmartin4693
So Navien didn’t have a good reputation in Maine. But that’s because it’s Viessman land. Oh well, I don’t like the new Viessman anyway. I really like the features of the Navien, it’s really becoming more popular here in Maine. They have a great selection of sizes and combis. Plus excellent service and are a well built product from what I see.
@JimSperanza
@JimSperanza Год назад
Yes there I'd a major lack of maintenance being done which causes many problems and people immediately blame the manufacturer.
@75mjwalsh
@75mjwalsh Год назад
With a 1 zone combi Navien Boiler System ... I wonder if the Webstone H-5FK5-CH would be an alternative?
@JimSperanza
@JimSperanza Год назад
This is much more expensive than the Navien manifold and does not need the pressure relief connection as this is already located on the boiler. Also this is a primary manifold and can be used for single or multiple zones, regardless of the zone quantity a primary manifold is required on this boiler.
@paulglendenning6409
@paulglendenning6409 11 месяцев назад
how big is the board you are using to mount everything on? just trying to get everything in perspective.
@JimSperanza
@JimSperanza 11 месяцев назад
About 4 high 5 wide
@hightechjoe1
@hightechjoe1 Год назад
The self fusing silicone tape holding the thermistors will loosen at higher boiler temperatures.
@JimSperanza
@JimSperanza Год назад
It's zip tied on underneath the tape.
@eddie3314
@eddie3314 Год назад
Cost??
@davidlucas4121
@davidlucas4121 Год назад
Was the customer using only 1 loop per zone? Great video.
@JimSperanza
@JimSperanza Год назад
Yes 1 loop per circulator.
@aaronhall4361
@aaronhall4361 Год назад
will the pressure relief valve be connected below the air separator?
@JimSperanza
@JimSperanza Год назад
The heating portion pressure relief valve is actually preplumbed internally on Naviens and is located on the top of the boiler. The domestic hot water pressure relief valve would be located on the service valves.
@yuryaraujo8796
@yuryaraujo8796 Год назад
Well done ! Explained everything super thoroughly. Keep up the good work!
@JimSperanza
@JimSperanza Год назад
Thanks!
@agentcmac
@agentcmac 9 месяцев назад
6:20 is so key!
@pavoutsinas
@pavoutsinas Год назад
vt2218 currently has circuit board issue as per Taco tech support. looking forward to revamp release to correct this some time after February 2023
@JimSperanza
@JimSperanza Год назад
I have heard of this but have not ran into any issues as of yet. What is the issue with the circuit board?
@pavoutsinas
@pavoutsinas Год назад
@@JimSperanza basically the display and settings dont control the pump. the pump works. from the sound and also the almost identical supply and return temps, it seems to be operating full speed constantly. the LCD display 6watts power and 00gpm which is obviously not correct since all panel rads are hot.
@zdravkocvijetic7637
@zdravkocvijetic7637 Год назад
How do you like the navien combo boilers? What do you think about gas leak problems on NCB 240e heat exchanger? I have navien ncb240e and have that gas leak, thinking to get something else but like navien more …. What u think ?
@JimSperanza
@JimSperanza Год назад
Typically what I've seen is the gasket deteriorating due to improper seating of the exhaust pipe.
@zdravkocvijetic7637
@zdravkocvijetic7637 Год назад
@@JimSperanza I got approved for new nbc 240/130H from navien itself
@JimSperanza
@JimSperanza Год назад
That is why I love Navien!
@dapperdave2090
@dapperdave2090 6 месяцев назад
where is the expansion tank?
@JimSperanza
@JimSperanza 6 месяцев назад
Expansion tank is not shown. It will be installed once the system is mounted on the wall.
@ericcecil6605
@ericcecil6605 Год назад
Noobie question....but shouldn't the air separator be mounted as high as possible in the system?
@JimSperanza
@JimSperanza Год назад
Good question. The air seperator works by "scrubbing" the air out of the system. There is a media inside that traps microscopic air bubbles and allows them to escape. However there is a air bleeder also on the boiler itself at the top which is used to remove the majority of the air at initial startup.
@JimSperanza
@JimSperanza Год назад
@@PipeDoctor Thanks!
@PabloPayan-g5v
@PabloPayan-g5v 11 месяцев назад
Awesome video man!! Thank you. I could use your help sizing my old equipment to upgrade to something like this. Can we connect?
@jacobanthony3260
@jacobanthony3260 Год назад
Great job curious to know why u don't have a high limit switch and low water cut off install. Is it not required in your state or is it built in to the navian
@JimSperanza
@JimSperanza Год назад
Both are built into the boiler. Some areas do require this regardless of whether the boiler has them or not.
@jacobanthony3260
@jacobanthony3260 Год назад
Seattle definitely does
@kriskaz2255
@kriskaz2255 Год назад
last question, can the magnetic filter go anywhere on the main line or does it have to be on the return side?
@JimSperanza
@JimSperanza Год назад
Always place it right before the return to the boiler.
@kriskaz2255
@kriskaz2255 Год назад
thank you@@JimSperanza
@timothyboconnor
@timothyboconnor Год назад
How can I contact you about a custom build?
@JimSperanza
@JimSperanza Год назад
Email me. Speranzadevelopment @gmail
@kriskaz2255
@kriskaz2255 Год назад
hi i was wondering if the magnetic filter is a must have.. i just had the same system installed and my plumber did not put on the magnetic filter
@JimSperanza
@JimSperanza Год назад
It's definitely recommended however if most of your system is copper baseboard or pex for Ilin floor systems you will likely be fine. If you have cast iron radiators or old piping you will definitely want to install one. Either way if you are doing annual maintenance and flushing the heat exchanger annually you will be ok.
@kriskaz2255
@kriskaz2255 Год назад
thanks for the quick response i apprecite it. yes all of my plumbing is in cooper in the home but this is the second navien boiler installed in the last 5 years becase of a failed heat exchanger. not sure what caused it and was wondering if it may have been magnite. i will probably install the filter just to be safe, i also installed a water softening system hopefully it will work. thanks again and great videos. i wish my plumber was as neat and organized as you are @@JimSperanza
@JimSperanza
@JimSperanza Год назад
@@kriskaz2255 did you flush the heat exchanger every year?
@kriskaz2255
@kriskaz2255 Год назад
no i just purchased the house from my inlaws and i know they did not do that. I certinaly will i hope if i stay up on the maintanance this thing will last. it was an expensive mistake that they did not keep up with the maintanance @@JimSperanza
@Steve-bm2zm
@Steve-bm2zm Год назад
Is that the model that only lasts a few years? Is the computer board black yet?
@paulglendenning6409
@paulglendenning6409 11 месяцев назад
what are you using for pipe support or pipe standoffs?
@JimSperanza
@JimSperanza 11 месяцев назад
Ceiling plates, threaded rod and pipe clamps
@paulglendenning6409
@paulglendenning6409 11 месяцев назад
3/8inch threaded rod?
@JimSperanza
@JimSperanza 11 месяцев назад
Yes 3/8.
@valenzaplumbing
@valenzaplumbing Год назад
Nice job.
@JimSperanza
@JimSperanza Год назад
Thanks!
@michaelsinderman653
@michaelsinderman653 Год назад
Where did you get the temp sensors for supply and return?
@JimSperanza
@JimSperanza Год назад
Local supplier.
@michaelsinderman653
@michaelsinderman653 Год назад
@@JimSperanza are they generic or Navien specific?
@JimSperanza
@JimSperanza Год назад
Navien part # (GXXX001769)
@michaelsinderman653
@michaelsinderman653 Год назад
@@JimSperanza thanks so much! I have a NCB-H, but the manual doesn’t show them working with that model. I’ll have to contact my local supplier!
@tomearnshaw8532
@tomearnshaw8532 9 месяцев назад
Be nice to see one fitted.
@cr7droneshow694
@cr7droneshow694 Год назад
No expansion tanque?
@JimSperanza
@JimSperanza Год назад
Yes it gets installed right below the air seperator. I don't mount them until I hang the board on the wall.
@cr7droneshow694
@cr7droneshow694 Год назад
@@JimSperanza ah ok tanks my friend.
@cr7droneshow694
@cr7droneshow694 Год назад
@@JimSperanza in a radiant floor do you use the usual thermostats?
@JimSperanza
@JimSperanza Год назад
I use a thermostat that can also sense the slabs temperature. Tekmar 519 is my go to.
@cr7droneshow694
@cr7droneshow694 Год назад
@@JimSperanza this thermostat brings sensors
@paulglendenning6409
@paulglendenning6409 11 месяцев назад
in and out of the Navien manifold did you reduce or stay at 1.5"?
@JimSperanza
@JimSperanza 11 месяцев назад
Reduced to 1.25
@ZIBO2830
@ZIBO2830 Год назад
Auto fill at this navien sucks
@ptech88
@ptech88 Год назад
I agree. Thats why a put a bypass for bleeding. Good call
@michaelisakov1108
@michaelisakov1108 11 месяцев назад
How much u charge to make a setup like this?
@JimSperanza
@JimSperanza 11 месяцев назад
Send me an email speranzadevelopment@gmail.com I can get you a quote.
@colin4685
@colin4685 Год назад
Not just do your job and build it at the house? so strange
@JimSperanza
@JimSperanza Год назад
Main reason is because that's not my job 👍
Далее
Combi Boiler Piping Explained
7:41
Просмотров 9 тыс.
Navien NFC-250/200 Combi-Boiler Retrofit #8
28:53
Просмотров 14 тыс.
Почему?
00:22
Просмотров 238 тыс.
Офицер, я всё объясню
01:00