Our Ebook, Paperback, Workbook, Quick Cards: www.acservicet... This video is on Normal Operating Pressures are for Freon R-22 and R-410A Refrigerants. I go over what affects the pressures on the low side and the high side, the saturation state pressures and temperatures, what too low of a pressure means on the vapor side and what too high of a pressure means on the liquid line. I go over the specific ranges of pressure for R-410a and R-22. Supervision is needed by a licensed HVAC Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In This Video
Yellow Jacket Refrigerant Gauge Set - amzn.to/2aenwTq
Refrigerant hoses with valves - amzn.to/2aBumVI
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• Fast Check for a Very ...
• Explaining Superheat a...
• HVAC Delta T Explained...
• Saturated Refrigerant ...
• Total Superheat Method...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicet...
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicet...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtoo...
Refrigerant Charging Book and E-Book: www.acservicet...
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicet...
Our Newest Articles: www.acservicet...
Try our HVAC/R Quizzes! www.acservicet...
Our Other Resources: www.acservicet...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicet...
Our Tool List on Amazon: www.amazon.com...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtoo...
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.c...
Apple Podcasts: podcasts.apple...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #r22 #r410a #lowpressure #superheat #charging #charge
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Опубликовано:

 

1 апр 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 390   
@acservicetechchannel
@acservicetechchannel 7 лет назад
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is the Link for the Yellow Jacket Refrigerant Manifold Gauge Set used in the videos- amzn.to/2aenwTq Here is a link to Refrigerant hoses with valves used in the videos- amzn.to/2aBumVI Here is the Yellow Jacket Manifold Gauge Set including standard hoses- amzn.to/2vLVkV9 Here is the Yellow Jacket 4 Port Brute Manifold with Hoses- amzn.to/2BkuGIq Here is the Fieldpiece SMAN360 Digital Manifold Set- amzn.to/2BdoaD4 Here is the Fieldpiece SMAN460 Digital Manifold Set- amzn.to/2nB4Fe6 Here is the Compact Ball Valve Attachment for the end of the Refrigerant Hose- amzn.to/2KUisW8 Here is the Quick Disconnect 90 degree attachment for the end of the refrigerant hose- amzn.to/2MMtVcg Here is a link to the UEI DL389 Multimeter used in the videos- amzn.to/2xAdaJf Here is a link to the Imperial 535-C Kwik Charge Vaporizer for Charging Refrigerant- amzn.to/2wFHtBW Here is the link to the Fieldpiece ST4 Dual Temp Meter- amzn.to/2wc1ME3 Here is a link to the Digital Refrigerant Scale used in the videos- amzn.to/2b9oXYl Here is a link for RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Other tool links can be found in the video description section. ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon. Check out other videos on the HVACR topics of interest at- ru-vid.com/show-UCOZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public If you want to support the ACSERVICETECH Channel and receive more HVAC content, check out www.Patreon.com/acservicetech
@frontiermarvin71
@frontiermarvin71 7 лет назад
acservicetech thank you for the videos !!!! I have learn a lot with them ! Probably more than I did in school!!! If you had a hands on lab to simulate some of the problems and you have a like weekend seminar many will go !! Please keep doing what you doing you are doing a great job to the community!!!
@acservicetechchannel
@acservicetechchannel 7 лет назад
Great idea frontiermarvin71! Thanks
@lesliedaisley7846
@lesliedaisley7846 3 года назад
Do you guys hire migrant workers bro I am from another country and willing to migrate to yours to dedicate myself and my time to work hard in the successful building of your Establishment
@richboyvlog7637
@richboyvlog7637 2 года назад
ty
@coolramone
@coolramone 2 месяца назад
⭐️⭐️⭐️⭐️⭐️Great video Craig. So informative. I usually see vapor lines at 70 to 75 psi (R22) and 120 to 125 psi (R410A), more or less. I learned something on the saturated temp explanation and the pressure variances you gave. (60-80 & 105-140) Thank you.
@mattzurzola4664
@mattzurzola4664 7 лет назад
I don't think you realize how many people you're helping by Doing videos and actually responding to comments a lot of people don't want to share their knowledge i've done installs but now I'm starting to get more into the service side of things and your videos have been a big help
@acservicetechchannel
@acservicetechchannel 7 лет назад
That's great to hear Matthew, thank you!
@EngQA-hg9eg
@EngQA-hg9eg 5 лет назад
Thank you so much for your time helpping us to understanding that..
@vineetsehgal4738
@vineetsehgal4738 5 лет назад
@@acservicetechchannel good morning sir I m very happy to hear u. Your work is point to point clear. Sir some deep questions for u? In r32 do we trust in pressure or trust in sticker level on the mini air conditioner outdoor which told 650g gas in 1.5 ton ac? If the pressure which if have to follow? Because old system efficiency is less. Do i put some extra gas like 50g extra or less? If i put the extra gas amps go up? Indoor unit is down, outdoor unit is on roof. Gas pipe is 3.5 meter. Distance is less can i cut pipe and make 2 meter? Would i have to extra gas charging? And if the 30 min with vacuum with refrigerator compressor is it right vacuum? If the vacuum without vacuum pump is it ok? Can i re-vacuum the unit because now how can i remove the air from the system if vacuumed with refrigerator compressor? Now i have to vacuum with double stage vacuum pump? Or i have to out totally gas from the system and then again i vacuum with vacuum pump? Please tell me help me?
@acservicetechchannel
@acservicetechchannel 5 лет назад
So first, when working with an empty system, you need to pressure test, oil blowout, vacuum with a VACUUM GAUGE, to verify that you are below 500 microns, then the 10 minute standing vacuum test, then break the system with refrigerant from the system or liquid refrigerant into the liquid line which is weighed in. If there is air in the lines mixed with the refrigerant, it needs to be recovered to specified level before starting over, thanks
@dallashensley2016
@dallashensley2016 3 года назад
I agree your videos are absolutely awesome your a great teacher
@davidmarler7
@davidmarler7 5 лет назад
man you are not only helping people with tech problems ,in my case you have help put food on the table for my kids and when I was starting out I could not really learn from other videos. you way of teaching is five star ! on point .and as the old proverb goes you give some one some bread you feed them for a day .teach them to make bread you feed them for life .thank you so much for all of your help you videos are so good you never have to ask a question its already covered
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks a lot David. I really appreciate your comment! Awesome!
@dimysimplice
@dimysimplice 6 лет назад
Thanks Jesus/God bless. More than two years I'm checking videos on RU-vid to know about that. You are the only one who give very good informations.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thank you Di Si, Praise the Lord!
@henrysaracay3881
@henrysaracay3881 7 лет назад
i went to school,but it seems that ur being more helpful than the school, thanks man nd keep doing such of great job I really grateful
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks a lot William! I am glad the videos are helping that much!
@hassanaljazaeri5436
@hassanaljazaeri5436 3 года назад
I watched this video more than 5! Time but every time I watch it I’m learning something new and very helpful thanks. Because I run to an ac with r22 refrigerant and has high pressure on high side and was afraid if I did something wrong to the system after I watch this video again I understand it was because it small condenser with low sears. Thanks again
@sugarfreementos
@sugarfreementos 7 лет назад
thank you Doctor. I am saturated now, just a homeowner not an installer will watch a couple more times, thank you for the video.. thumbs up.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Ha Ha thanks!
@vernroach3413
@vernroach3413 6 лет назад
As a former instructor and soon to be, instructing again, I can appreciate the clarity and ease of understanding, just what this video explains...Will made, great orating and I will use this method, if not the video itself...My thanks to the gent that made it...To people that want future employment...Learn the trades.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks a lot Vern! Enjoy Teaching!
@silvioatejedor
@silvioatejedor 6 лет назад
I just want to thank you for spending your time teaching people like me that are hungry for knowledge like yours you have a big heart I’ve subscribed little while back and enjoy very much the videos thanks again
@acservicetechchannel
@acservicetechchannel 6 лет назад
I appreciate that very much Silvio!
@dantinas
@dantinas 7 лет назад
You're detailed videos are hands down the best I've seen on You Tube. Great job !!!
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thank you very much dantinas!
@padilla7019
@padilla7019 2 года назад
This video has given me more understanding in reading the gauges and what can be going on
@fortinosuarez7962
@fortinosuarez7962 4 года назад
There are many things I learned on your videos. Hard to explain. Thanks. God bless you and your family.
@acservicetechchannel
@acservicetechchannel 4 года назад
Thanks for letting me know! May the Lord Bless You Too Fortino!
@kenmassaplumbingheatingair4092
Thank you for making amazing videos. Very much appreciate the time you put into them. They are to the point, extremely well done. Thanks!
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thank you very very much Ken!
@CG-qc1ob
@CG-qc1ob Год назад
Thanks for your videos just finished trade school I started doing side jobs thanks
@daveyt4802
@daveyt4802 3 года назад
My 19 year old R-22 system is dying. 2 ton unit. Trying to get an idea how to change to the new and best stuff. Nice job!
@southtexasprepper6605
@southtexasprepper6605 6 лет назад
I've been working with ACs for the past 4 years but i am really wanting to learn about super heat since the ACs at my job use a piston, thanks for the detailed info, one of the best vids I've seen.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Theo! Look up "acservicetech superheat playlist" for more!
@mulliganstein
@mulliganstein 7 лет назад
Great Video. Very informative and not alot of wasted time giving shout outs to friends or talking about unrelated topics. You can tell when someone does their homework beforehand. This is exactly the type of video I'm looking for when searching for info on youtube. RU-vid needs more folks like you. Thanks a bunch!!!!
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks a lot Robert!
@ronaldferrer167
@ronaldferrer167 5 лет назад
You are great easy to understand and most important pro technician qualified..to do the job.thanks for sharing your knowledge..is power..
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks Ronald!
@RubTN
@RubTN 5 лет назад
Really appreciate you and this channel!!! Love you man. I bought your book!!
@acservicetechchannel
@acservicetechchannel 5 лет назад
Awesome, thanks for letting me know!!!
@BGLENN-dp4tx
@BGLENN-dp4tx 7 лет назад
Thanks for sharing your extensive knowledge. You would likely enjoy the details of wide-body jet airconditioning systems. Since the OAT varies from say 115F when taxiing out for takeoff in, say, Phoenix to -41F OAT at 39,000 feet cruise altitude, the aircond "packs" work to cool the cabin at low altitudes but must function as "heaters" when it's 41-deg below zero at cruise altitude. The most remarkable characteristic about these a/c "packs" is that they do not require any charge of refrigerant. In fact, there is NO refrigerant in the system except fresh air. The system takes (bleeds") high pressure air from the engines to drive a compressor (turbine) that inducts outside air, compressing it, then cooling it in the slipstream, then allowing it to expand again. As you know, this cycle creates a powerful thermal exchange. Then, the cold expanding exhaust is simply piped into the aircraft. By controlling how quickly this volume of air is injected into the cabin, the aircraft can be "pressurized" as well. The fact that no airconditioning refrigerant must be added means that the systems are extremely reliable and the performance doesn't vary since the compressor is a rotary turbine, not a rotary piston whose efficiency is affected by wear. Thanks again for your videos. I would enjoy sitting down with you to ask you questions. RU-vid is the next best thing. Good luck sir.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks for the awesome, detail filled learning experience for everyone. Thank you for taking the time to write it. Are you a pilot, engineer, or mechanic?
@BGLENN-dp4tx
@BGLENN-dp4tx 6 лет назад
Retired, flew 40 years. Thanks again for your stellar videos.
@cesarorozco2462
@cesarorozco2462 5 лет назад
All I am going to say, "THANK YOU" you do know what you are talking about.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks Cesar! Our book goes into great detail about all the methods, false methods, troubleshooting and much more, thanks!
@roelvargas6195
@roelvargas6195 3 года назад
Very knowledgeable video you helping a lot of technician out there
@acservicetechchannel
@acservicetechchannel 3 года назад
I appreciate that!
@w5cdt
@w5cdt 4 года назад
Excellent coverage of condenser and evaporator pressures for R22 and R410. Thanks for the info!
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad to help!
@omarrc9628
@omarrc9628 6 лет назад
this make it easier for me to comprehend the science behind it.. i rewind constantly to make sure i understand.. although i dont understand SEER measurements yet..
@acservicetechchannel
@acservicetechchannel 6 лет назад
It has to do with how efficient the unit's energy transfer is and therefor electrical energy used to transfer the heat energy. In reference to an outdoor unit, the higher the seer, the larger the surface area of the coil is. The indoor evaporator coil would need to be larger as well to attain a higher seer rating, thanks
@jamesmanderschied2929
@jamesmanderschied2929 3 года назад
Great Video and SOLID explanation!!! Thank You!
@acservicetechchannel
@acservicetechchannel 3 года назад
Glad you enjoyed it!
@fernandob8239
@fernandob8239 6 лет назад
Hey bro I appreciate your channel it's helping us to be better at our craft.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Fernando!
@A123American
@A123American 4 года назад
Great demonstration and easy to understand, thank you!
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad it was helpful!
@jacklabloom635
@jacklabloom635 4 года назад
Thank you explaining this. Great video.
@acservicetechchannel
@acservicetechchannel 4 года назад
My pleasure!
@Carlossoto-rg5hh
@Carlossoto-rg5hh 4 года назад
Thank you for making these videos, I am an installer transitioning to service Tech
@mikemc8495
@mikemc8495 5 лет назад
I love watching these videos when I feel like my teacher didn't completely explain it. I guess I should read more out of my book also Great videos
@acservicetechchannel
@acservicetechchannel 5 лет назад
Yeah, I'm not sure the book will give you all the ins and outs but more of just the premise with a couple of examples. Thanks Michael!
@carlosburgos7836
@carlosburgos7836 3 года назад
Thank you for your information
@acservicetechchannel
@acservicetechchannel 3 года назад
So nice of you
@posterboyrob
@posterboyrob 2 года назад
Well explained. So helpful.
@Lorenzo69
@Lorenzo69 Год назад
Excellent video 👍
@mechacc2000
@mechacc2000 6 лет назад
Check the gauge's saturation temperature for each refrigerant against a PT chart. At one time I found one set of gauges where the R-410a temperatures did not match the pressure against a PT chart. Always verify your equipment is correct.
@acservicetechchannel
@acservicetechchannel 6 лет назад
I found that once too. That was an interesting one! Always check
@HowToDoitright
@HowToDoitright 2 года назад
Really good explanation!!!
@DEW409
@DEW409 7 лет назад
I wonder if TUMP could possibly reverse the ridiculous ban on R-22? All the millions wasted on overpriced R-22 and its inferior replacements. Not to mention a lot of older units replaced with junk new ones that will leak in a year or less due to garbage "high efficiency" coils combined with the excessive pressures of 410a.
@versus8329
@versus8329 3 года назад
Thanks for this video bro! it helps a lot.
@acservicetechchannel
@acservicetechchannel 3 года назад
Glad to hear it!
@ScottM-qh8ce
@ScottM-qh8ce 2 месяца назад
Is it normal for head pressure to swing upwards of 70-100psi while running? On a 70 degree day. Unit is around 300psi high side and swings up to 380-400 and then back down. Low side is about 125psi
@HeaanLasai
@HeaanLasai 5 лет назад
Thank you for making all these videos! I'm a student with very limited funds, so I need to do almost all of my design and planning myself. May I ask something? I need to design a low cost multi stage cooling system to achieve liquid nitrogen temperatures on a budget. Compressors will be commonly available refrigeration compressors. They will use increasingly colder refrigerants, so that only the last two stages need to use non-phase changing refrigerants such as nitrogen or helium. Consider that heat flux through the system will be fairly limited, it will be designed to achieve low temperature rather than maximum efficiency or heat flux. So I mean to design the system for a relatively low pressure in the suction line, to get the temperature in the evaporator as low as possible for each refrigerant. In such a system, with a low refrigerant flow rate and common refrigeration compressors, what would be a reasonable suction line pressure to aim for? During the build I will get help from people with experience with these systems, but planning is always done more or less solo and as I've never designed a refrigeration system before I have no idea what would be reasonable. Regards
@acservicetechchannel
@acservicetechchannel 5 лет назад
I would not know that one. I don't design systems like those. You would really need a good engineer for that one, thanks
@patrickmichael8749
@patrickmichael8749 Год назад
What is the max pressure required for an inside evaporator. My evaporator has 400 psig. Can I use it for R-410A after flushing out the r-22?
@workingshlub8861
@workingshlub8861 3 года назад
what about roof top package type units???....i was told do not worry about subcool or superheat method and just charge by pressure...could not find a subcool rating anywhere ..has txv valve
@Phillipinewannabe
@Phillipinewannabe 2 года назад
Great videos watched just this one about five times haha
@donnierobertson3088
@donnierobertson3088 4 года назад
Great job and video
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad you enjoyed it
@gormleym77
@gormleym77 2 года назад
If a system at sea level has a standing pressure of 14.7 psig on a standard gauge does that mean it is completely void and anything less is technically under vacuum/ open to moisture contamination?
@earthisheart6797
@earthisheart6797 5 лет назад
Have you ever tried adding PAO oil to a r22 system? All the data I've seen is that it's compatible with mineral oil.
@edlauren9434
@edlauren9434 7 лет назад
Thank you for your videos. Very easy to understand and very informative.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks Eduard!
@alexluna6810
@alexluna6810 6 лет назад
Thank you Leo !and Acservicetech! you guys are awsome!
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Alex!
@abdulmatheen106
@abdulmatheen106 5 лет назад
Great video good easy explanation I found more information in this video thank you
@kdlgutterinstallation6675
@kdlgutterinstallation6675 4 года назад
I have a question. Let's say in NC the ambient temperature outside is 80 degrees and you are using R-410A refrigerant. What should my high side and my lowside pressures be? Second question if you charge the unit with a subcooling of 12 because that is what it calls for will you still have the same subcooling at 95 degrees in the summer?bAnd what will your high side and low side pressure s be?
@ungarlinski7965
@ungarlinski7965 2 года назад
What should the blue/low guage read when re-filling with R22? This would be in a constant temp climate like Miami of about 85 deg F.
@patrickhanifan5066
@patrickhanifan5066 2 года назад
It depends on a few factors but sometimes you wont see the suction gauge go up much because it depends on the metering device and some other factors or you wont be able to charge the refrigerant much because of the devices in the line. Otherwise, most of the time the suction and discharge gauges will reach equilibrium once the refrigerant settles. Alot of times you have to charge as much as you can with the system off then turn the system on so you can finish putting in the rest of the charge because you need a better pressure differential. Ive even had it where i can barely put in refrigerant while the system is off and i had to manually turn on the compressor or bypass the low suction pressure sensor because i couldnt get enough refrigerant in the system for it to stay on long enough because it kept tripping on low suction pressure
@juliangonzalez3541
@juliangonzalez3541 7 лет назад
thank you. for passing on this information and teaching us about hvac
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks redd!
@905Alive
@905Alive 4 года назад
We have a min of 95F cond temp on all systems so you're going to have a low of that on 22 or 410 systems, so 22 shouldn't be any lower than 190psi and 410 280psi, any lower and the system needs head pressure controls or it will crash, you won't be able to maintain control of the low side and you might slug the compressor, variable speed equip might be the exception.
@relaxatry2347
@relaxatry2347 7 лет назад
Hi i have a Daikin 2HP mini split installed in my house. It has R22 refrigerant. Temps at my place can get upto 110F during peak noon 1-3pm. Cooling is reduced upto 35% when its peak heat around 100-110F in evenings or night temps are around 80-85F it works cold. And the outdoor unit is exposed directly to sunlight and it has around 12 meters of copper piping installed. The low side is 70 psi when outside temp was around 100F
@acservicetechchannel
@acservicetechchannel 7 лет назад
Is this an inverter style or single speed compressor? Do you have an indoor temp diff between the return air and supply air of 18 degrees when it is 80-90 degrees outside?
@relaxatry2347
@relaxatry2347 7 лет назад
Its single speed R22 split.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Does it say a rated subcooling on the rating plate? Is there a charging guide on the back side of the shroud. It likely has a txv on the outside and yes if it is a single speed then you can check the charge with subcooling for txv units and superheat for pistons. Subcooling of usually 8-12 degrees for txv equipped, single speed, comfort cooling units without a stated txv rating. thanks
@relaxatry2347
@relaxatry2347 7 лет назад
acservicetech its plate says R22 charge 1.5kg. If the outdoor unit is directly exposed to sunlight heat of around 100F it will effect the cooling of AC and make compressor run more harder
@acservicetechchannel
@acservicetechchannel 7 лет назад
Absolutely, if it were installed in the shade it certainly would be better as long as long as air flow was not cut off, thanks
@robertfrancis4310
@robertfrancis4310 2 года назад
Good video
@masaladosa8868
@masaladosa8868 4 года назад
Hi question: what caused the low press pipe condensor outside frosting and hi press pipe cold on the evaporator side ( when you touch it) ? this happens when The AC has been running over 10 hours then temperature house stuck at 24.5 degrees C then the indoor house turning hot again? thank you
@patriotdarktolight1780
@patriotdarktolight1780 2 года назад
Thank you !!
@jorgedelaossa9899
@jorgedelaossa9899 3 года назад
Thank you
@jimsmith5756
@jimsmith5756 4 года назад
Very good and informative video!
@Sondai75
@Sondai75 2 года назад
I have a question. Our AC Unit was checked and we were told that it was working great. It was a model from 2008. However, by the following day our unit was no longer cooling and the refrigerant was completely empty. We also had water near our furnace from the evaporator coil. I requested the report from the company and these are the numbers that were listed. High Side Pressure=210, High Side Temp=105, Low Side Pressure=70, Low Side Temp=38. Were these readings ok? Or was it indicative of a problem?
@maddog5814
@maddog5814 2 года назад
What about high outdoor temperature and low wet bulb like in the south west?
@hvacguy11
@hvacguy11 4 года назад
Amazing your channel is the best!!!
@mechacc2000
@mechacc2000 6 лет назад
You should add that a technician must verify the correct volume , CFM, of airflow before charging a system.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Yes, thanks
@acservicetechchannel
@acservicetechchannel 6 лет назад
Absolutely, they must be done before checking the charge. Thanks Gary!
@jackpast
@jackpast 7 лет назад
Nice one, Craig. Lot's of good info here. Thanks!
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks Jack, hope all is well!
@keithhoward8651
@keithhoward8651 7 лет назад
Thanks for the info. It really does help a lot. Thanks for taking the time to make the videos.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Great to hear Keith! Thanks
@solomonlutchmansingh1156
@solomonlutchmansingh1156 3 года назад
Can i use an r22 guage to measure pressure on an r410a system
@purrungas2012
@purrungas2012 6 лет назад
top of the line video, beautifully simplified explanation of the gages, best one I have seen yet, thank you much
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks purrungas2012!
@b-riair9114
@b-riair9114 6 лет назад
Do you know why on carrier heat pumps only why you have to get high side pressure in heating mode on the larger hot discharge line service port and if you check the 3/8 service port pressure it will be close to your suction pressure? On every other manufacturer you get high side pressure on the 3/8 service port in heating and cooling. Thanks!
@acservicetechchannel
@acservicetechchannel 6 лет назад
Brian, That is because they have the metering device in the piston chamber right before your port when the subcooled liquid is flowing from the indoor coil toward the outdoor coil. The piston is right under the nut. If the port were 3 inches closer to the indoor coil, it would be high pressure subcooled liquid. You are reading low pressure liquid with 20 percent flash gas at that port because it is right after the metering device in heat mode. Other manufacturers place their piston chamber inside the outdoor unit so it is further downstream, thanks
@b-riair9114
@b-riair9114 6 лет назад
AC Service Tech LLC that makes sense I just would think the hot discharge gas pressure would be too high because of the increased temp / pressure created from the compressor to be an accurate high side pressure
@acservicetechchannel
@acservicetechchannel 6 лет назад
Are you talking about following a manufacturer charging procedure for a heat pump in heat mode because other than that, we can't really check a charge in heat mode due to not knowing how much refrigerant is in the accumulator. We are stuck with total weight procedure or reducing condensor airflow to raise high side sat temp in cooling mode but it would need to be 38 degrees or higher ambient temp for that method, thanks
@ashutoshchhiba3385
@ashutoshchhiba3385 3 года назад
Hi craig. In ductless Minisplit , refrigerant is available both indoors and outdoors. So standing pressure (when compressor is not on) will correspond to Indoor temperature or outdoor temperature or something in between and why??
@danielvazquez9078
@danielvazquez9078 4 года назад
so critical and helpful information, thank you
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad it was helpful!
@justinberrett7479
@justinberrett7479 3 года назад
Thank you for your videos. I too learn more than I did in school. My question is with a r22 system in Las Vegas 115 outside what would I expect the temperature to be in middle of condenser coil? It is a10 seer split system. Thanks
@mtbbiker6401
@mtbbiker6401 Год назад
I have 2010 (13 years old) Trane 5 ton 14 SEER heat pump, TXV. Label states the following: R410A, 10 degree subcooling, comp RLA 26.4, Design PSI HIGH 480 LOW 480. Anyone know what "Design PSI HIGH 480 LOW 480" means? It's not cooling very well so I took pressures today when it was 111 degrees outside. Readings were High 510 PSI (136 degrees saturation), liquid line 118 degrees. Low 135 PSI (46 degree saturation), vapor line 74 degrees. That's 18 degrees Subcooling and 28 degrees SuperHeat. Not sure I truly trust my line temps since I'm using an inexpensive thermocouple. I may need to invest in the Fieldpiece thermocouple you use in your videos. How does high ambient temps affect pressures and line temps? If using approach method, my liquid line is 7 degrees above ambient but my pressure should be closer to 480, not 510 PSI. I also checked my compressor amps at about 23 amps. RLA is 26.4. I'm going to check the pressures again in the morning when it's closer to 90 degrees.
@jklmnk9596
@jklmnk9596 4 года назад
Thank you for sharing your knowledge and experience .
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad to help Haben!
@michaelgarcia4503
@michaelgarcia4503 2 года назад
Hey I have a system that is reading 250 on high and low side
@Benji.
@Benji. 5 лет назад
Awesome channel! There is so much bad information out there on this topic so thank you for teaching us! Btw how are window and portable units able to operate at 300psig low / 520psig high (R410a). I’ve been looking everywhere for an answer and can’t find one. They are usually completely sealed systems and don’t have service ports. But even if you install a port, how would you fill it to 300psig?! It seems like they can’t be repaired. There is usually a sticker with the specs on the side of the unit and that’s where I’m getting these numbers from.
@Benji.
@Benji. 5 лет назад
Or perhaps it’s the maximum pressure the unit is built for..... yeah probably that. :)
@acservicetechchannel
@acservicetechchannel 5 лет назад
Yes that is the max design pressure for sure, they operate the same as other r410a fixed orifice systems and you would mout the port on the low pressure side to check the superheat since it has a capillary tube as the metering device, thanks
@charliekidd5606
@charliekidd5606 4 года назад
Should a unit be running when checking levels on a manifold or is the reading the same if off power? I’m getting a reading of 220 psi on my mini split while the unit is off.
@jameslee2465
@jameslee2465 6 лет назад
Thank you for your video, guru. My AC is RUDD UACC-036JAS, R22 refrigerant system, it has refrigerant leakage, the Tech refilled R22 to Low Pressure at about 62 psi, High Pressure is 220 psi, is it ok for cooling? but I feel it is slow to make rooms cool. What is the best psi of Low Pressure for my AC? Thanks.
@acservicetechchannel
@acservicetechchannel 6 лет назад
he would need to check it with superheat or subcooling but the refrigerant will eventually leak out again. He would need to find and fix the leak. You could also check for 18-21 degree temp decrease between the return air and supply air to verify it is working correctly, thanks
@merrickwightman9959
@merrickwightman9959 4 года назад
I have a Embraco VEGT 8H compressor and i'm not sure what low side pressure I should be seeing on the guage. I have seen videos on freon charging that say 2 and others that say 30 psi. If anyone has the answer I would be grateful. At the moment my low side pressure is 10psi and im not sure if i should add or remove freon. thanks
@NorCal-refrigeration
@NorCal-refrigeration 7 лет назад
Enjoy all the videos.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks Nor-Cal, I appreciate what your efforts as well!
@MrGarcon98
@MrGarcon98 4 года назад
question please ,,i am a retired tech from way back i never got to work with 410A BUT ! i have enough r22 in my garage to charge a new system now having said that ,,,,,have you ever took a 410A , change the oil ,tvv, to make it work with r22 ? can i do that ? or have you heard of someone that did this or maybe you ? ,,,,,,thanks for your opinion
@enduringpromise
@enduringpromise 3 года назад
Thank you for your videos. I have a question about the "expected pressure" on the high side, can we take the SEER rating, refrigerate type and the outside temperature and add a constant value to get the expected high side pressure? So for a example a R22 on a 85 degree day for a SEER 13 would mean the pressure should reflect 85 + 20 = 105 F. Then covert 105F on a PT chart?
@jollyscaria1922
@jollyscaria1922 11 месяцев назад
Kow the are . Diffwrnce in temperraure of of out and room air and u factor the heat leakge rhrufh wall . Cilling and floor per hour canbw calculated using the following equation .. Heat leakge =ufactor xtemperature difference =uxAxTD (u=factor -Btus =area -squre feet Td=tempreaature difference -°f.
@raybosflorida4928
@raybosflorida4928 6 лет назад
BEST VIDEO ON RU-vid !!THX!!
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Raybo!
@RobRocker09
@RobRocker09 Год назад
Hi amazing video by the way. At the end when you talking about the unit being 300 psi being too hot due to condenser failing, could be a clogged dryer or piston too.
@lovebaby1686
@lovebaby1686 3 года назад
hello ,i hook the low side but needle not move can you tell me why? thank you
@67tr876
@67tr876 5 лет назад
I just started up my own little system but its a medium temp system . Now am confused my friend says it is under changed and I know it is. My high side is at 151 psi and my low side is at 42 Psi How is it that am getting 41F across my coil and my suction temp is at 53F for the compressor. All I know if for my system the evaporator coil needs to be under 40F say about 30F to 35F. Maybe I just need to keep adding gas but when I do my compersser shuts off on high pressure. I am confused it is water cooled as well.
@papoloco34
@papoloco34 7 лет назад
Acservicetech this is really but really a exelente video man...can you make some more videos like this one explaining the pressures and the simtoms or problems like you did on this one...we really need videos like this one well I need videos like this one.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks Pedro, check out these for now and then let me know what exactly you would like to see, thanks!
@acservicetechchannel
@acservicetechchannel 7 лет назад
ru-vid.com/group/PLxnHR5_D2ojxZI3-xx03Bttxe3xCqUD87
@shawnwhite8022
@shawnwhite8022 4 года назад
This is great thanks for your help 👍
@jaypd34
@jaypd34 4 года назад
have purchased a 5# tank of R410A for top up of unit. Tech says I need a valve to regulate pressure from tank. ???? Enjoy your blog...
@eddy72286
@eddy72286 3 года назад
My low side pressure reads 200+. When I add 410a, it goes even higher. High side reads 285. No idea what’s going on. It’s like it’s not taking my refrigerant.
@omarispence8888
@omarispence8888 4 года назад
Your having a huge impact in the industry. I bought your book.
@acservicetechchannel
@acservicetechchannel 4 года назад
Thank you for your support!
@oglerdeleon9494
@oglerdeleon9494 6 лет назад
You're jesus son my friend your video's are very helpful. I really appreciate it. God bless you!!
@acservicetechchannel
@acservicetechchannel 6 лет назад
Praise the Lord!
@nassauman6809
@nassauman6809 4 года назад
Awesome video 👏🏽👏🏽
@rtd2348
@rtd2348 5 лет назад
Your videos are great man have really learned a lot from the way you teach things and make them easier to understand. How do you know what the head pressure should be for an R22 and 410A system if the outdoor coil is clean and the ambient is around 70 degrees F. I was taught anything above 70F, add 30F and that should be your saturated condensing temperature. So if it’s 80 degrees ambient add 30 degrees which gives you 110F. See what pressure that corresponds to using a pt chart for a given refrigerant and that should be your pressure. Is that a good way to determine what your head pressure should be
@acservicetechchannel
@acservicetechchannel 5 лет назад
What you are describing is that old ambient plus 30 rule of thumb. We use superheat and subcooling for efficiency and compressor safety. That was a rule that got you close on old 10 seer r22 units. Look up "acservicetech subcooling and superheat" I also have everything explained in detail step by step in the book at acservicetech.com thanks!
@rtd2348
@rtd2348 5 лет назад
AC Service Tech LLC Thanks, I really appreciate the info and your videos have helped me tremendously throughout my apprenticeship
@toddbehrends1373
@toddbehrends1373 6 лет назад
What is a good time to check your system to see if it is running right? Do you want to check the system when the outside temp. is around 60-70 degrees? I am going to check the systems on our rental property.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Typically the first 70 degree days when there is a load on the building, thanks Todd!
@JM-yx1lm
@JM-yx1lm 6 лет назад
I think he meant when to check it. The answer, i think, is, it doesnt matter because its charged by superheat or subcool. The varible that would matter, is the indoor temperature should be normal like less than 80 or so
@alexluna6810
@alexluna6810 6 лет назад
Just and simple air conditioning i turned off ..i hooked the gauges and turned it back on And i waited until the refrigerant stabilize. But the the vapor side keept on rising near 300 psi it has a piston instead a txv.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Ok I was wondering if you had a reversing valve or not. If the furnace is not on then you may have bad compressor valves on the compressor or a bad refrigerant charge with mixed air or nitrogen with it. What is the pressure when the system is off and stabilized for 20 minutes compared to the outdoor temp using the p/t chart? I am assuming this is an R410a system. Did you check out the "acservicetech bad compressor valves video"?
@pinoassenza2970
@pinoassenza2970 4 года назад
Where to normally find the metering devices on typical residential systems? Thanks
@patrickhanifan5066
@patrickhanifan5066 2 года назад
In the same panel as evaporator coil or right outside the evap coil usually unless it is a fixed orifice or exv. Those are usually at the condenser. But they are all on the liquid line going to the evap coil
@willschroeder6494
@willschroeder6494 6 лет назад
Thanks for these videos
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Will!
@bass3man2u34
@bass3man2u34 7 лет назад
Hi, can you have a expansion valve and a piston both in a heat pump system? It look like I have a piston at the condenser and a expansion at the evap I have a heat pump system.
@acservicetechchannel
@acservicetechchannel 7 лет назад
Yes only one is active at a time. The other will bypass through. Check this video out as it will explain active and non active- ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-2Ahzi1U0fYk.html
@hvacae6904
@hvacae6904 4 года назад
What is the suction pressure of ac unit with a r 410a charge
@user-ik4br3nk2w
@user-ik4br3nk2w 3 года назад
110 to 136 PSIG on the low side? The data plate on my condenser says 410A PSIG LOW: 236 HIGH: 446
@acservicetechchannel
@acservicetechchannel 3 года назад
Those are not running pressures but design max pressures, the running pressures will change with the heat load inside and outside the house, thanks.
@sidtrex1
@sidtrex1 7 лет назад
Good VDO easy to understand thanks
@acservicetechchannel
@acservicetechchannel 7 лет назад
Thanks sidtrex1!
Далее
How to Check AC Freon Level
16:52
Просмотров 2,1 млн
How To Use AC Gauges
26:34
Просмотров 1,2 млн
How I Add Refrigerant to an Air Conditioner
10:20
Просмотров 377 тыс.
How To Check Superheat & Subcooling On An HVAC System
16:03