Тёмный

Ram Pump Delivery Pipe Closed at the Top 

Land to House
Подписаться 251 тыс.
Просмотров 2 тыс.
50% 1

The Ram Pump delivery pipe can be closed at the top of the delivery while the pump is running. This will cause the pump to cycle without an output and the pressure tank will build full pressure allowed by the input head pressure. If there is not enough lift out to maintain back pressure the pump will stop when the delivery pipe is opened at the top after pressure has been built up in the line.
Buy a Ram Pump at the Land To House Store:
landtohousesto...
Ram Pumps available on AMAZON
amzn.to/2EWrQHN
Help Support land To House by Paypal:
paypal.me/land...
Send Mail to Land To House:
Land To House llc
P.O. Box 323
Micaville, NC 28755
See whats coming up before it hits RU-vid on my Facebook Page:
/ landtohouse
Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@TradisionalChannel_Indonesia
@TradisionalChannel_Indonesia 2 месяца назад
simple... but extraordinary benefits
@MyPreppingJourney
@MyPreppingJourney 2 месяца назад
Here's maybe a new question.... What happens if you have equal sized waste and delivery vales and reduce the size of the waste valve ia reducer, or i guess even have a smaller waste valev. is there less waste vs. delivery water...... Hmmnnn
@dynamicdyna
@dynamicdyna 3 месяца назад
you already try the waste valve is smaller i mean the you install the pump pipe is 1 1/2 and the waste valve reduce in 1inch diameter, thanks
@hayderalsalman7984
@hayderalsalman7984 3 месяца назад
Good job now you need to do same cable and pipe arrangement inside Trench 🎉 in future as you saied
@jllaine
@jllaine 3 месяца назад
Nice demonstration, thank you.
@salmobiblico
@salmobiblico 2 месяца назад
Hi did you tried the drum to take water out of a pond or well?
@jayjay6804
@jayjay6804 3 месяца назад
The difference is because when the 'static' pressure is changed to 'dynamic' pressure it is enough to cause an imbalance in the system as you stated. However, the 'static' pressure will always be the same at the top of the delivery pipe and at the pressure chamber when the upper delivery valve is closed. It is a closed system at that point and pressures are equal throughout. Problems can be avoided by using a relief valve or a bleed off orifice at the top of the delivery pipe to avoid a static pressure situation. You can verify this by comparing two pressure gauges at each end of the delivery pipe and closing it off.
@davebaldwin7218
@davebaldwin7218 3 месяца назад
Soo.. I'm about to purchase the 3/4 to 1/2 del. What is the best way to stop water flow without having to restart pump
@LandtoHouse
@LandtoHouse 3 месяца назад
You can stop the pump from the top of the delivery as long as you have enough lift. In this example I had the delivery pipe right at the lowest possible point to demonstrate the loss of pressure.
@davebaldwin7218
@davebaldwin7218 3 месяца назад
@LandtoHouse I will have about 65 ft of lift from creek up a bluff. I was worried it would be too much lift
@RamPumpShop
@RamPumpShop 3 месяца назад
@@davebaldwin7218 The water outlet shutoff does not affect the operation of the rampump. If you are worried about too much pressure, you can install a safety relief valve on the rampump like I did. When the water outlet shutoff pressure exceeds the set value, the safety valve will open to discharge the high pressure.
@hayderalsalman7984
@hayderalsalman7984 3 месяца назад
Can we use two pressure tank on the same ram pump and can that increase head
@LandtoHouse
@LandtoHouse 3 месяца назад
I ran a test on that a while back. It does not increase the output.
@RamPumpShop
@RamPumpShop 3 месяца назад
The function of the pressure tank is to buffer vibration and store pressure through compressed air. Adding more pressure tanks can only make your ram pump vibrate less when running. But it will not increase the head or water output~
@workbenchz
@workbenchz 3 месяца назад
Without a pressure tank, the pump has to push all the water in the delivery pipe uphill all at once and that is a lot of rest inertia to fight. The air space in the tank compresses allowing more water to rush into the tank and then slowly push the water uphill. Two tanks or a larger single tank can allow more air space to be compressed and more water enters the tank, but only up to a point.
Далее
Start the Ram Pump for 2024
13:11
Просмотров 119 тыс.
Ram Pump Standpipe Placement
6:22
Просмотров 3,3 тыс.
Review pompa hidram 4", SANAN Hydraulic Ram Pump
21:03
How Does a Hydraulic Ram Pump Work?
8:56
Просмотров 7 млн