Тёмный

Randell Pizza Prep table is not cold enough 

REFRIGERATION KITCHEN TECH
Подписаться 10 тыс.
Просмотров 16 тыс.
50% 1

In this hvacr training video, I will troubleshoot a cooler that isn't getting cold enough and will go over refrigeration pressures for the unit.
Instagram / refrigerationkitchentech
tik tok / refrigerationkitchentech
/ rketec

Хобби

Опубликовано:

 

27 авг 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 50   
@johnstrh1
@johnstrh1 4 дня назад
this video was such an awesome learning experience for me. Had a few of these units that I could never get dialed in just by charging correctly.But now that I know how to dial in the TXVs I can do a way better job next time.
@bensreferigeration
@bensreferigeration 12 дней назад
Excellent procedure to dial it in.
@j.r.jackson7351
@j.r.jackson7351 Месяц назад
I might start watching your videos. Ive been about 20 yrs in the field, mostly residential and light commercial. I started working at a company that does this small refrigeration stuff and i hate it.
@musakavalci9470
@musakavalci9470 Год назад
Yet another excellent video. Thanks for sharing your knowledge
@vincentlamoureux8446
@vincentlamoureux8446 Год назад
Easy money! Nice repair!
@EverythingHVACR
@EverythingHVACR Год назад
Nicely done! 💪
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Thanks Steve!
@cruzfernandez4554
@cruzfernandez4554 10 месяцев назад
Excellent 👍 thank you so much. I was looking for this information all over.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 8 месяцев назад
Glad it was helpful!
@chadrayl9648
@chadrayl9648 Год назад
Man your good!
@sergiomateo7671
@sergiomateo7671 Год назад
Nice. I understand this units better now. Pizza Hut have similar and I always have trouble understanding them at first.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Yes, took me some time to understand these types of units. Seperate the base and rail and think of them as 2 different systems and it becomes a lot easier
@vnesmuonnam
@vnesmuonnam 10 месяцев назад
Thank you
@deanmohamed7575
@deanmohamed7575 Год назад
oh wow, i did not know that!! No wonder the rail never cools down to temp when the box is running. I always wondered how the heck the rail cools down with that high of a pressure. So it only actually cools down properly when its running by itself. Thank you so much!
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Yes, I’ve seen it where it cools faster when the base is running, but that tells us the TXV is not adjusted correctly
@ErickHernandez93
@ErickHernandez93 Год назад
Way to go brother 😎 another great video man Wish i can do the same with customer being all over the place too much 😂😂😂
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Lol
@csamms8090
@csamms8090 Год назад
Dude. Thank you lol just worked on one at a dominos.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 11 месяцев назад
Lololol nice
@MrRealtalkME
@MrRealtalkME Год назад
Hey can you make a video on adjusting and having the correct pressures you make it look easy and I’m still having some issues understanding what is correct pressures for reach in coolers and freezers.
@JDT738126
@JDT738126 Год назад
Same here. I do air conditioning and the refrigeration side is somewhat a curveball.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Watch this video until you understand it fully ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-IL4nDK82KBU.html
@MrRealtalkME
@MrRealtalkME Год назад
@@REFRIGERATIONKITCHENEQTECH Thanks bud , question for a cap tube system True 2 door RIF M#TM-52F 404A 17 Oz Does the pressures change with the box temp is high? Cap tube system pressures stays consistent but does it change while the box gets colder. I’m assuming yes since pressure correlates with temperature. I did see the video you recommend but just wanna ensure myself lol
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
When the box temp is very high it will increase the suction pressure but not by a lot like a TXV.
@harrydickson4575
@harrydickson4575 Год назад
👍👍👍
@wasimedoo7994
@wasimedoo7994 4 месяца назад
Very good job bro keep it up God bless 👍
@enriquemontenegro5222
@enriquemontenegro5222 3 месяца назад
Do you have a video on how to adjust a txv? Thanks !
@JDT738126
@JDT738126 Год назад
Hi, your videos are great! If you have time can you please make a video on how to properly select and install a capillary tube metering device? I was hoping to get enough understanding to design any type of cycle refrigerating and freezing. Thanks
@williamzelonis5606
@williamzelonis5606 Год назад
Your mirror qualifies for a “Purple Heart.” Had a number of mirrors that looked like that.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Lol, if I didn’t continuously break them 1 week into buying them, I would replace it
@richhayner1208
@richhayner1208 2 месяца назад
What is the spin thing to test solenoids?
@alessichris07
@alessichris07 Год назад
If I had a dollar for every Randell soldered joint leak I have repaired, I could retire. Well maybe not. LOL That is very common on Randell, especially the pizza prep units.
@wd8557
@wd8557 Год назад
I worked on two units from China Astoria or something like that. Both showed low pressures. High side bouncing around. Both contaminated from the factory. Changed out the driers vacuumed all good.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
We will make things right one unit at a time
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Lol, yup, the brazing seems to be an issue at the factory
@shine-cg9uf
@shine-cg9uf Год назад
👍💪❄️🇺🇸 Nice work. A lot to absorb. What’s the blue crap on copper lines? Is that dried glycol residue? Thanks for sharing
@shine-cg9uf
@shine-cg9uf Год назад
Rail section is using glycol as a heat transfer, I’m guessing?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
No glycol in this unit
@johnson4940
@johnson4940 Год назад
At the 0.39 second what tool are you using?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Magnetic field detector
@bowen1969
@bowen1969 Год назад
How did you come up with the pressures on both sides of the system to achieve 55 psig in total ? If the base temp was 35 f @ a 20 td that would be 49 psig ! Could you please show me how you got a total off 55 psig ? Or did I miss something when watching? Thanks love your video pleses kerp them coming !!!
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
That’s how the engineers set up the cooler to run, at 55psi when the rail and base are both on. When only the base is on, we drop to 35F. On a normal cooler, you are correct with 49psi. These units are complicated but you just need to troubleshoot them separately
@bowen1969
@bowen1969 Год назад
Thanks ! Your guys are lucky to have someone with knowledge willing to lead them in all aspects of our trade in fridge and food ! What you are teaching us on RU-vid must be only the tip of the iceberg for what you are teaching them .thanks really enjoy all your videos
@papasteve7237
@papasteve7237 Год назад
Is there any chance I could get a link to that knee pad, Sir?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Got it from United Refrigeration
@foodtravelxp24
@foodtravelxp24 Год назад
Hi sir you video is important. But i want to know r 404 a gas -temperature walk in freezer superheat limit how °f and +temperature how many superheat limit Same like that r134 a gass superheat limit
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Looking for 6-10F superheat.
@foodtravelxp24
@foodtravelxp24 Год назад
Tnx for information. I am from Bangladesh. I am seeing all of your video.
@foodtravelxp24
@foodtravelxp24 Год назад
I don't understand your calculation if you tell details
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Год назад
Superheat = the temperature of the copper line close to the TXV bulb “minus” the suction saturation temperature
Далее
THE COLD RAIL IS NOT GETTING COLD
16:28
Просмотров 32 тыс.
True 3 door Cooler is not Cooling
13:16
Просмотров 17 тыс.
Randell Pizza Prep-table Warm
10:28
Просмотров 7 тыс.
Randell Prep Cooler 2Door,2Drawer(WARM)
11:09
DELFIELD PREP TABLE FREEZING FOOD
10:13
Просмотров 28 тыс.
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
OUR WALK IN IS TOO COLD PLEASE HURRY
17:21
Просмотров 37 тыс.
R-290 Service Training
10:51
Просмотров 192 тыс.
Prep table cooler is not cooling
5:53
Просмотров 10 тыс.
True Reach in cooler is not cooling
8:20
Просмотров 20 тыс.
今流行ってる椅子取りゲーム
0:31
Просмотров 73 млн