Тёмный

Replace Leaking Water Heater Relief Valve 

How To HVAC
Подписаться 2,3 тыс.
Просмотров 25 тыс.
50% 1

I am replacing a leaking hot water heaters pressure temperature relief valve. I first verified that the tank itself is not leaking and waters coming out of the relief valve. Before this video I check the pressure of water at the tank. The house’s water pressure was 65 psi. Therefore I first drain down the water heater. Next pay remove the relief valves pipe to send water to floor. After that I remove the relief valve. Next I put Teflon tape sealant on the relief valve threads once I install the new relief valve. I refill the water heater. Finally I turn the water heater back on wash it run and make sure no more water leaks out.

Опубликовано:

 

28 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@moonpixyart4562
@moonpixyart4562 2 года назад
I said made in the USA then you said it, love it.
@Dnyce07
@Dnyce07 2 года назад
Great simple instructions, thank you, my issue is water running straight from my turn off valve to the pan and outside the house and it's not a drip, it's a steady flow outside, could this still be that my temperature relief valve needs to be replaced or is it something else Bill?
@howtohvac3234
@howtohvac3234 2 года назад
At Home Depot they sell a pressure gauge in the plumbing section. The gauge has a hose connection. Attach it to the drain valve of tank. Check pressure. If pressure is under 100 when tank is hot. Then I would say most likel it’s the relief. You will most likely need a new relief even if it’s a pressure issue.
@Elijahtb
@Elijahtb Год назад
​@@howtohvac3234lp Paper 0 j88l88b7p6po7i
@williamserver4332
@williamserver4332 3 года назад
I've never seen the hot and cold bonded together . usually cold to the gas line .
@howtohvac3234
@howtohvac3234 3 года назад
It’s code in nj to help ground both hot and cold pipes since cold water line is connected to gas, and a dedicated ground.
@MerlosTheMad
@MerlosTheMad Год назад
Does the length of the temperature element of the relief valve matter at all? the new one I bought is 1/3rd the length of the old T&P valve's temp. element.
@sbobrowski81
@sbobrowski81 2 года назад
Made in the USA❤️
@GaryYoung-eq1ph
@GaryYoung-eq1ph Год назад
NOT all relief valves leaks r external like going into pan like urs , some go into wall pipe and to somewhere out side of apt. condos!
@roymiller447
@roymiller447 Год назад
The pressure release valve still leaks after replacement. Any suggestions? Thanks, Roy
@howtohvac3234
@howtohvac3234 Год назад
Do you have hi water pressure?
@anthonylee6322
@anthonylee6322 11 месяцев назад
You forgot to show that you need to shut off the gas and put it on pilot. And where is your Victory Beer Bill ?
@frederickneal4781
@frederickneal4781 2 месяца назад
You did'n't relieve the pressure first by opening a hot water faucet
@audreykattan7977
@audreykattan7977 Год назад
👍🏻Absolutely use MADE IN USA 🇺🇸
Далее
Water Heater Leaking At Relief Valve Diagnose / Fix
15:29
Каха заблудился в горах
00:57
Просмотров 3,1 млн
How To Flush Your Water Heater THE EASY WAY
8:13
Просмотров 499 тыс.
Replace Water Heater T&P Valve (Step-by-Step!)
6:05
Просмотров 25 тыс.
Каха заблудился в горах
00:57
Просмотров 3,1 млн