I do a refrigerant change over, I remove an old suction filter, 3 pressure controls, install a Ranco dual pressure control, install 2 shraetor valves, reclaim the old R408A, pull a vaccum, change the drier filter, add POE oil, charge with R407F and check operation.

Хобби

Опубликовано:

 

2 окт 2015

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 85   
@alphaomega5923
@alphaomega5923 5 лет назад
Mr. Pettinato, I wish you were my instructor when I was attending the HVAC/Refrigeration School. You are the man, Sir!
@hannarye
@hannarye 8 лет назад
I had this one customer with 3 different convenient stores. His family is from India. Salim and his wife ran one store and his two sons ran the other two. Was servicing his stores for about 20 years. Every time I went in there his wife always had some sort of Indian food waiting for me. He paid well, she cooked well and I kept his stuff running. They sold out a few years back. I gotta say, I miss that family.
@JamesPettinato
@JamesPettinato 8 лет назад
+hannarye up here I call them the Cleveland Indians, I find them to be friendly, good bill payers, technical minded and generally good people, my only complaint is they sneak up on me when I'm working and watch
@hannarye
@hannarye 8 лет назад
Haha, so true. Salim had bad breath so I always knew when he was looking over my shoulder. LOL
@JamesPettinato
@JamesPettinato 8 лет назад
+hannarye that's funny
@frontiermarvin71
@frontiermarvin71 8 лет назад
THANK YOU FOR THE LESSON !! YOU ARE A WONDERFULL TEACHER !! PLEASE CONTINUE WITH THE GREAT JOB MR PETTINATO .
@supermoto3453
@supermoto3453 8 лет назад
I was taught in trade school rla is 1/6 of lra not 1/5 but your still dead on with a heavy load thx for the vid I learn something new everytime I watch one
@sergiografbike
@sergiografbike 8 лет назад
More vídeos Jim!!! You are a teacher! ! Best Regards from Brazil
@georgegikas9307
@georgegikas9307 8 лет назад
I am hvac technician from Greece, learn a lot from your video.You like your job.Thank you.
@ago1854
@ago1854 2 года назад
Great canal Jim! Greatings from Poland.
@anruiz85
@anruiz85 8 лет назад
Great job !!! Thanks for the recommendation of adding Poe oil..
@JuanLopez-zc5mz
@JuanLopez-zc5mz 8 лет назад
also, jim dont quote me on this but if i remember right where it says on the lable I-operation max is your maximum amps of operation. yours says 15.1
@MaheshPatel-nk9fg
@MaheshPatel-nk9fg 8 лет назад
Another great video lesson Jim. Good job well done!
@walterbellamy6468
@walterbellamy6468 8 лет назад
Thanks Jim.. you remind me to do neater work..
@JamesPettinato
@JamesPettinato 8 лет назад
+walter bellamy the customers usually look at what we do, thanks
@leonbogon148
@leonbogon148 5 лет назад
nice work jim as always
@salehhamid
@salehhamid 8 лет назад
Nice Job and helpful information as allways ,, Thanks very much for the great effort
@JamesPettinato
@JamesPettinato 8 лет назад
+salehhamid thanks
@awsom70
@awsom70 8 лет назад
nice work as always jim!
@stevengilber1153
@stevengilber1153 8 лет назад
Nice clean job, jim
@rashpalsingh2050
@rashpalsingh2050 8 лет назад
thanks! Jim. Good job.
@jonathansmith3019
@jonathansmith3019 8 лет назад
Great set of videos Jim. Thanks for posting and give in to the dark side.
@JamesPettinato
@JamesPettinato 8 лет назад
thanks
@user-gy2fg4wk4g
@user-gy2fg4wk4g 7 лет назад
teacher. Thanks for your videos
@1captjake
@1captjake 8 лет назад
Your next leak is going to be that suction line accumulator. I don't understand why someone would of put 408 in that system. Seem like it would cause high amps at the compressor. Hopefully it lasts! Thanks for the great videos!
@JamesPettinato
@JamesPettinato 8 лет назад
+1captjake the 408 was put in back around 2001, it's rated for low and medium temp, it was actually working good. thanks
@hvacrnortheastern2110
@hvacrnortheastern2110 8 лет назад
Nice job Jim
@hardcooling
@hardcooling 8 лет назад
Another great job done Jim
@JamesPettinato
@JamesPettinato 8 лет назад
+hardcooling thanks
@jeffburton8350
@jeffburton8350 8 лет назад
very informative video Jim , thanks
@JamesPettinato
@JamesPettinato 8 лет назад
+jeff burton thanks
@nicholasceea4109
@nicholasceea4109 8 лет назад
Nice work Jim
@JamesPettinato
@JamesPettinato 8 лет назад
+Nicholas CeeA thanks
@chenchris7576
@chenchris7576 8 лет назад
good job jim
@arniegrote319
@arniegrote319 8 лет назад
Nice Job Jim, and cool on the amps 1/5, I didn't know that. Nice to know I have been calling Copeland all the time.
@benp8366
@benp8366 8 лет назад
I would look into that. I believe that is just a real rough estimate for most single phase motors. Its good if you need a general ball park #
@benp8366
@benp8366 8 лет назад
The actual number can be anywhere from 1/5 to 1/10 more or less
@ryandong7271
@ryandong7271 8 лет назад
love you smile! always learn something new from new video.
@JamesPettinato
@JamesPettinato 8 лет назад
+Ryan Dong thanks
@SteveSam66
@SteveSam66 8 лет назад
Jim, Nice Job
@JamesPettinato
@JamesPettinato 8 лет назад
+S Sam thanks
@chiwoody48
@chiwoody48 7 лет назад
Thanks for sharing. Job well done.
@Dyllanes_Ingeniero
@Dyllanes_Ingeniero 8 лет назад
Very good. Thanks for your videos
@JamesPettinato
@JamesPettinato 8 лет назад
+Angel Diaz thanks
@NytefogNJ
@NytefogNJ 8 лет назад
Nylog, best stuff made for service port caps/valves. I also love blue monster PTFE tape it's superior to the request white teflon!
@heavydiesel
@heavydiesel 8 лет назад
Nice work Jim!
@JamesPettinato
@JamesPettinato 8 лет назад
+heavydiesel what refrigerant are you going to lately, thanks
@heavydiesel
@heavydiesel 8 лет назад
+Jim Pettinato All the old R22 stuff gets converted to R407F or R407C, not done any new low temp stuff this year but chillers are on R134a. All our aircon has been R410A for the last fifteen years or so, so its rare to see any R22 stuff, though there is still some R407C equipment from just after R22 was banned for new aircon.
@gonzgarr1592
@gonzgarr1592 8 лет назад
great job with lots off tipsthanks
@JamesPettinato
@JamesPettinato 8 лет назад
+gonz garr thanks
@airmechanical7163
@airmechanical7163 8 лет назад
Another great video.
@JamesPettinato
@JamesPettinato 8 лет назад
+Air Mechanical thanks
@drummerdem50
@drummerdem50 8 лет назад
Good tips, thanks
@RobHVAC
@RobHVAC 8 лет назад
More high praise.
@eastlandgin
@eastlandgin 8 лет назад
The liquid line off the drier is making contact with the electrical compartment. It could be a problem over time because of the vibration and/or galvanic corrosion . I think you should have bent the metal back a little bit or at least put a rubber spacer to prevent rubbing.
@jcorona305
@jcorona305 8 лет назад
Good Job.
@bblazeff1
@bblazeff1 6 лет назад
OMG! You leak locked a flare fitting!!?? a good flare never needs leak locked.
@angelcalderon9714
@angelcalderon9714 5 лет назад
you the best
@lambofdeceit
@lambofdeceit 8 лет назад
another great video Jim - was that a shout out to me =)
@businjay
@businjay 8 лет назад
Love your videos Jim, even if you do look like darth vader,
@JamesPettinato
@JamesPettinato 8 лет назад
+Jason Windecker :)
@jimbola77
@jimbola77 8 лет назад
excellent!!!!!!!!!!!!!!!!!!!!!!!!!
@randykocian4738
@randykocian4738 8 лет назад
Saw you changed from 407c to 407f in latter videos. You did say it has less 134a in it. Do you like hotshot2. Dont have to worry about oil. Price isnt bad. Like your videos. You & Lav. You've done your homework and then some.
@JamesPettinato
@JamesPettinato 8 лет назад
+Randy Kocian haven't used hotshot2, honeywell makes Preformax R407F, that's what I use.
@NorCal-refrigeration
@NorCal-refrigeration 8 лет назад
Darth Vader, that was funny. Great job.
@JamesPettinato
@JamesPettinato 8 лет назад
+rasta1kikker :)
@natedaniels2854
@natedaniels2854 8 лет назад
hello jim how do you know how much freon to put into the unit . or do you wate until the sight glass has no bubble in it
@djonathan1
@djonathan1 8 лет назад
jim, how do u make the measurements for the oil, you said that Honeywell says the amount that can be used but, do u have any website or something to read and learn about it, u know i enjoy watching your videos, non of my colleagues know the 407F, i've used it in replacement of 22 and works excellent
@fathmasameer7523
@fathmasameer7523 7 лет назад
thank u sir
@JuanLopez-zc5mz
@JuanLopez-zc5mz 8 лет назад
had not noticed steve had commented on that
@RCG1211
@RCG1211 7 лет назад
What's the make and model of that oil pump deal u used to pump,Poe oil in
@marjones69
@marjones69 8 лет назад
I really hate Flared fittings,,,These things will creep right down no matter how good your flares are or how tight it is, but thanks to you i have started using leaklock and teflon... I am partial to brazed joints, reason being, a couple less chance of leaking...nothing worse than a call back...Jim that receiver tank doesn't look to good, like its ready to leak underneath it., great job as usual though Jim.
@JamesPettinato
@JamesPettinato 8 лет назад
+marjones69 the flare connection has been a staple connection from the beginning, if done correctly it will last for years with no problems, and it makes it easy to replace an expansion valve or a drier filter. thanks
@marjones69
@marjones69 8 лет назад
I know, still I will limit my flare joints as much I can
@jmrhvac4542
@jmrhvac4542 8 лет назад
nice job Jim a lot of information do you rather use the air acetylene then oxyacetylene torches
@JamesPettinato
@JamesPettinato 8 лет назад
+james rook the last time I used an oxyeacetylene tourch was around 1971
@kosworkshop
@kosworkshop 4 года назад
how do you know how much oil to put in it? How many pumps or is it 20% of total charge or is that just 20% poe oil? Please help.
@johnmiller102
@johnmiller102 8 лет назад
Nice job Jim. How did you determine when you had in 20% of the poe oil in the system? Is that based on the amount of the factory min oil already in the system?
@JamesPettinato
@JamesPettinato 8 лет назад
+johnmiller102 guess/judgement
@gulopac1
@gulopac1 8 лет назад
Good job Jim, where did you buy the teflon tape? is that teflon tape resistant to refrigerant oil?
@JamesPettinato
@JamesPettinato 8 лет назад
+oscar guti I think all teflon tape is oil resistant, my supply house is where I bought it, You can buy it at home depot too, it's in the plumbing section. Thanks
@fridgydownunder6734
@fridgydownunder6734 8 лет назад
so your'e fan Star Wars too Jim! lol
@JamesPettinato
@JamesPettinato 8 лет назад
+Edgar Jamilaren :) thanks
@neptuneappliancerefrigerat9902
Jim Pettinato super job jarek poland
@ArisBuliteanu
@ArisBuliteanu 11 месяцев назад
27:27
Далее
Compressor change
34:44
Просмотров 150 тыс.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 23 тыс.
The principle of auto expansion valve
0:59
Просмотров 96 тыс.
DIY Vapor Compression Refrigeration System
28:06
Просмотров 1,1 млн
The Truth About SIM Card Cloning
13:04
Просмотров 1,1 млн
One year old compressor failed, time to troubleshoot
24:52
Refrigerant Overcharge Troubleshooting and Prevention
21:47
Service Call: Following another company!
35:09
Просмотров 12 тыс.
Заварушка на пляже!
1:00
Просмотров 5 млн
Modern Wood Rifle / Woox Furiosa Ultra
0:30
Просмотров 11 млн