Тёмный

Salus Thermostat Installation In 10 Mins | Baxi Main Eco Elite 

Advanced Boiler Training
Подписаться 8 тыс.
Просмотров 45 тыс.
50% 1

These resources will teach you how to diagnose and fix any boiler: signup.advancedboilertraining...
Walkthrough on how to wire a Salus RT520RF Thermostat on a Baxi Main Eco Elite.
Tools used in this video:
Nws multi cutters: amzn.to/3XosG6n
Knipex ergostrip: amzn.to/3jLl4NP
Voltage tester screwdriver: amzn.to/3HXHeEF
Salus RT520RF Thermostat: amzn.to/3lx51nn
Milwaukee Impact Driver: amzn.to/3Is8ug1

Опубликовано:

 

13 янв 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 59   
@user-gb2dc3fm8v
@user-gb2dc3fm8v Год назад
I never seen anyone explain so clearly. Even the work, so neat! Well done to you!
@lmcm7311
@lmcm7311 Год назад
Finding the content of these videos really helpful as a trainee, thanks bruv keep up the good work 🤟
@mrm.k7655
@mrm.k7655 8 месяцев назад
Very clean video. Well done
@camping_101
@camping_101 4 месяца назад
Thank you so much for this video. I used it to do a DIY install of a TADO system. Amazing.
@abuutariqable
@abuutariqable 7 месяцев назад
Great and clear training
@danielgrist5830
@danielgrist5830 8 месяцев назад
Very good video, helped me out, thank you
@rm-mastering
@rm-mastering Год назад
As always, great video, thanks so much.
@advancedboilertraining
@advancedboilertraining Год назад
Glad you enjoyed it!💪
@user-li8gr8ur8l
@user-li8gr8ur8l 5 месяцев назад
Good content mate ❤ make it look very simple.
@joshd790
@joshd790 Год назад
You need to post more mate your videos are great
@advancedboilertraining
@advancedboilertraining Год назад
Ah thanks Josh! I try but with work being busy sometimes it’s hard 😅
@gardengnome2409
@gardengnome2409 Год назад
Superb. Many Thanks.
@paulmurphy5396
@paulmurphy5396 Год назад
Brilliant video
@advancedboilertraining
@advancedboilertraining Год назад
Thank you Paul 🤝
@samxday
@samxday 5 месяцев назад
Good video. Thanks
@vandersarlok
@vandersarlok Год назад
Thanks for your viedo, support you !
@advancedboilertraining
@advancedboilertraining Год назад
Thank you! I really appreciate it👊
@jasonfarley6947
@jasonfarley6947 Месяц назад
What do I need to do with the boiler mechanical timer dial?
@mikegallagher2107
@mikegallagher2107 Год назад
brilliant mate keep up the great content
@advancedboilertraining
@advancedboilertraining Год назад
Thanks Mike!👊
@mikegallagher2107
@mikegallagher2107 Год назад
@@advancedboilertraining anytime i,ve got quite a few to get through
@yousufb93
@yousufb93 11 месяцев назад
Awesome video, been looking for a informative video like this for ages. So the mechanical timer that is built into the boiler does that not work anymore? So you need to link the live to the com so when it makes a connect to the switch live, it send the live current back to the boiler telling it to power up the heating? Very good video , liked and subscribed
@Z901Z
@Z901Z Год назад
Nice one brother!
@advancedboilertraining
@advancedboilertraining Год назад
Thank you! 👍
@raul835
@raul835 Год назад
Brilliant vid
@advancedboilertraining
@advancedboilertraining Год назад
Thank you!!👊
@suheilhanna873
@suheilhanna873 Год назад
Thanks for your vedio, please 1 question, can I use 4 cores, and use the 2 switch wires on terminal 1 2 going to com and no on the thermostat, instead of adding link between live and com on the thermostat please??? 2:06
@rosariadipaola9
@rosariadipaola9 4 месяца назад
Brilliant video. I managed to install an hive thermostat by myself and I have this exact boiler (the name is different as mine is Potterton Apollo, but probably it's just a name). The only thing I have some doubts is about the integrated control with the pins. I set it on 1,otherwise the receiver switches on but not the boiler. Is that correct? Again great video considering that I did everything and I have no knowledge of electrical stuff 😂. Thank you!
@craigwebster7405
@craigwebster7405 Год назад
Good video, the newer salus looks good
@advancedboilertraining
@advancedboilertraining Год назад
Thanks! Yeah this newer one looks really nice
@peterjohnson9108
@peterjohnson9108 7 месяцев назад
Well done .you have now cut out the circuit protective conductor .Which protects the flex cable. A better way would have been to connect the flex earth to the earth terminal at the combi side . Then to terminate or choc Earth at the other side. Also the 2x black cable's are twisted together as there was no link cable. Available. I would have guessed. Still enjoyed the video 😊
@Dcoatess
@Dcoatess 6 месяцев назад
Going from salus to hive installation. Looks to have the same amount of wires as the hive mini does. Could you do a video on switching from salus to hive ?
@mominforeva
@mominforeva 4 месяца назад
I got salus fermo starter but I never able to set up with boiler.very inoing
@milanpatel2082
@milanpatel2082 8 месяцев назад
when we start the tap water as hot mode then heating gose start them selve with it what do on this situation…
@davidharris8885
@davidharris8885 7 месяцев назад
Thank you
@user-gb2dc3fm8v
@user-gb2dc3fm8v Год назад
Sorry can I ask you a question, I have no central heating but I have the same boiler. For some reason the central heating on the boiler is always on even if I Dont have it. Is there away that I can disconnect a wire? So that it doesn’t keep the boiler always running even when not using. I tried turning the central heating temp to 0 but still it’s always on. Thanks for your help in advance.
@nadeeralikhan1668
@nadeeralikhan1668 3 месяца назад
What N O stand for mention it above
@trytryandtryagain52
@trytryandtryagain52 4 месяца назад
Clear, professional, neat, informative. What more can I say? Great video.
@train4905
@train4905 Месяц назад
Exellent😊
@imnotacommi-boo8507
@imnotacommi-boo8507 Год назад
How does power reach the boiler if we disconnect the wires from the terminal in place of the thermostat receiver’s wires? The black cable that was originally linked to the terminal is linked to the mains so how does the boiler still work when we replace it with the cable straight from the receiver?
@lucaslaba
@lucaslaba Год назад
Always read the instructions
@petersingh4268
@petersingh4268 Год назад
Hi mate what’s type of cable do you use ? 4 core?
@advancedboilertraining
@advancedboilertraining Год назад
Yeah 4 core
@bobwilson4195
@bobwilson4195 Год назад
my main eco boiler is 4 years old . when I opened the electrical box all the wires where as you said except there was a link wire in the last two slots . do I still put the gray wire in with them ?I do have both lights working in the receiver ok. but the boiler seems not to want to start at times I have set.
@advancedboilertraining
@advancedboilertraining Год назад
Hi, take the link out
@bobwilson4195
@bobwilson4195 Год назад
@@advancedboilertraining Done all that wired up as per video, I've removed the link left the old timer on do I leave it on perm or timer program . both light are working , I've tried testing by putting the temp setting above the room temp but still won't fire up unless I put the old mechanical on . seems to defeat the idea if having a wireless thermostat . any comments .
@advancedboilertraining
@advancedboilertraining Год назад
@@bobwilson4195 Just leave the timer on the boiler constantly on. Then control the heating from the thermostat
@bobwilson4195
@bobwilson4195 Год назад
What about the old timer do you just leave that as is?
@advancedboilertraining
@advancedboilertraining Год назад
Yeah just leave it on the on position
@buchyu
@buchyu Год назад
Great video- thanks! What are you contact details for work? Seems you are in East London?
@mikesweeney1827
@mikesweeney1827 10 месяцев назад
Not allowed to use Black for a Nautral anymore..Grey is the Nautral and Black is the switched live
@posei3960
@posei3960 Год назад
Earth wires should be run to,all,points and not just cut off. Connects at the boiler end, terminate in a Wago at Salus end. Neutral also needs identifying with a blue 'marker'. Convention is grey for neutral, black for aux live/switched live in a 4/5 core flex or 3 core and earth cable. Just saying
@advancedboilertraining
@advancedboilertraining Год назад
Yeah electrics aren’t my strong point, thanks for the comment. I’ll bear these in mind for when im next doing a stat
@leemclaughlin3927
@leemclaughlin3927 6 месяцев назад
Why if its unused ? Terminating it into a wago seems pointless tbh
@Videowatcher85
@Videowatcher85 5 месяцев назад
@@leemclaughlin3927 It’s a safety precaution. With an earth connected the flex cable is protected and could cause the rcd to trip if there was a fault. Without the earth connected than a potential live fault (a nail into the live or the cable sheath gets damaged by the metal boiler casing for instance) wouldn’t operate the rcd, thus leaving an unsafe install. It’s unlikely in this scenario where the flex is so short but it’s not only good practice, it is a requirement of the BS7671 wiring regulations.
@leemclaughlin3927
@leemclaughlin3927 5 месяцев назад
@@Videowatcher85 it was only cut back at the stat but still inside the rest of thr flex - so a nail through the flex would still have same protection surely
@bizarroceramics
@bizarroceramics 5 месяцев назад
I wouldn't advise anyone to install a Salus thermostat. They are an absolute disaster. I'm having mine changed ASAP. I'm tired of getting up at 6AM to go downstairs and turn the heating on manually because YET AGAIN the thermostat schedule has stopped working from the APP on the phone .Don't waste your money. Go with a different brand.
@MegaChaos91
@MegaChaos91 6 месяцев назад
Answer me this, please: I know that Brown = Live | Blue = Neutral | Green+Yellow = Earth, but what really annoys me is all that COM/NO/NC bull****. Please tell me which wire color that gibberish corresponds to. Thanks.
@martynlewis9020
@martynlewis9020 Год назад
Good luck with the Salus 5 year warranty, you can no longer call Salus. There is an email address for them but they only respond with automated replies. I won’t use their products anymore!
Далее
아이들은 못말려 〰️ With #짱구
00:11
Просмотров 442 тыс.
What turned out better to repeat? #tiktok
00:16
Просмотров 4,5 млн
RT520RF Pairing To RXRT520
1:34
Просмотров 98 тыс.
How To Install A Hive Smart Thermostat - Combi Boiler
14:22
Instalare termostat Salus RT310RF (model 2018)
11:04
Просмотров 175 тыс.
Universal Backplate all you need to know
7:42
Просмотров 34 тыс.
How To Install A Hive To A Combi Boiler
10:08
Просмотров 33 тыс.
Boiler wiring made easy
23:37
Просмотров 9 тыс.