In this video I show how to install a Hive Single Channel thermostat to a combi boiler.
There are a number of different ways this can be done, but this is the simplest and most straightforward method for me.
Links to other videos that I've done explaining thermostat wiring
• How to wire a room stat
‪@KNIPEXUK‬ Ergostrip (Right Handed)
16 95 01
This video is not for homeowners to attempt a repair on their own boiler, but an assistance to existing Gas Safe Registered engineers. Any attempt to work on a boiler is at your own risk.
#plumbing #heating #vaillant
Powered Now - Job Management Software
www.powerednow.com/cputility

Опубликовано:

 

19 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 50   
@user-li8gr8ur8l
@user-li8gr8ur8l 3 месяца назад
Thank you Chirag❤. Short and simple one. Top quality as usual keep it up..
@cputilitysolutions
@cputilitysolutions 3 месяца назад
Thank you
@Enormous_Rod
@Enormous_Rod Месяц назад
Good video, no waffle cheers
@cputilitysolutions
@cputilitysolutions Месяц назад
Thank you 👍🏾
@garygormley3842
@garygormley3842 7 месяцев назад
Great videos you’re making with good hints and tips. What’s the black thing you got on your right wrist, is it for work purposes?
@cputilitysolutions
@cputilitysolutions 7 месяцев назад
Thanks mate, glad you enjoy them. It's a magnetic wristband I got off eBay for holding case screws, etc so I don't lose them 😉
@alexonline607
@alexonline607 7 месяцев назад
Thanks for the video. What would you do with existing thermostats/heating controls?
@cputilitysolutions
@cputilitysolutions 7 месяцев назад
You would remove them and depending how they've been wired you could reuse the existing wiring for the hive
@richardhodgson7443
@richardhodgson7443 9 месяцев назад
Great video, what ferrals do you use thanks
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
Thank you 👍🏾 I just got a set with the tool off Amazon. Was around £20-30
@tonyontele
@tonyontele 2 месяца назад
Hi, great video. Is the wiring the same for the Ideal Vouge Max Combi 40?
@cputilitysolutions
@cputilitysolutions 2 месяца назад
I've not wired it to a Vogue before but the concept would be the same 👍🏾
@tonyontele
@tonyontele 2 месяца назад
@@cputilitysolutions 👍
@JayG2K
@JayG2K 9 месяцев назад
On older worcester bosch boilers the connector block is soldered to the PCB called ST10. are new ones now losses as shown in the video?
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
I can only go by what I'm working on 👍🏾
@whistler2670
@whistler2670 8 месяцев назад
Great explanation! What would happen if I didn't link the L+1 together? Changing my old Danfoss programmer to a Hive thermostat and can only see a 5 core cable, but only permanent live and switch live cables are connected to current programmer/thermostat, which made my wonder. Many thanks
@cputilitysolutions
@cputilitysolutions 8 месяцев назад
You may have a separate permanent live feed going to the common terminal. If so then that wire will go into no.1. If not then then you need to put the link in to give power to the common terminal 👍🏾
@sandeeppatel2627
@sandeeppatel2627 4 месяца назад
Great Vid!!! Is the Hive Mini programmable or do I need a Hive Active for this?
@cputilitysolutions
@cputilitysolutions 4 месяца назад
Yes it is but you need to have the hub I believe
@theblackprophet1
@theblackprophet1 8 месяцев назад
Hi you have probably heard this question before, but I currently have a dual channel receiver for separate heating and water control (installed myself using instructions) but I will be moving to a house with a comb boiler. Is it possible to wire the dual channel as a single channel? It just seems like a complete waste of money if I have to buy a single receiver. There is a rumour it can be done, but know one has shared a definitive. I want to call an engineer out to do the work but I don't won't waste his or my time if I have to buy a single receiver / kit. Any advice would be great.
@cputilitysolutions
@cputilitysolutions 8 месяцев назад
Hi, yes it can be done but you have to alter the wiring accordingly to suit and you leave out the hot water side of wiring
@theblackprophet1
@theblackprophet1 8 месяцев назад
@@cputilitysolutions thank you for clarification. I thought it would be something like that but wanted to make sure. I still gonna call an engineer in though at least I know it can be done. Better to be safe.
@conordoherty4761
@conordoherty4761 5 месяцев назад
The HIVE is all connected correctly and sending the signal to the control valve, but the boiler isn't lighting. I've removed the time clock so that is just an off and on on the main panel. Am i missing something?
@cputilitysolutions
@cputilitysolutions 5 месяцев назад
Would need to see if you're getting power on the switch live to the boiler
@jessicabroad1985
@jessicabroad1985 2 месяца назад
Which wiring ferrules do you use size wise?
@cputilitysolutions
@cputilitysolutions 2 месяца назад
Depends on the cable size, they come in a pack of various different sizes, mainly I use 0.75mm or 1mm
@JayG2K
@JayG2K 9 месяцев назад
also the original clock/timer MT10 clock could have been removed and a filler black insert fitted in its place.
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
👍🏾
@ericthekingthekingtheking4842
@ericthekingthekingtheking4842 4 месяца назад
hi mate iv got existing receiver with two brown and two blue do i need to add a link for a hive ? theres no link in this one at the moment
@cputilitysolutions
@cputilitysolutions 4 месяца назад
I can't say without seeing the receiver and the wiring setup. It sounds like you've got 2 Live & 2 Neutral probably supplying something else too
@ericthekingthekingtheking4842
@ericthekingthekingtheking4842 4 месяца назад
@@cputilitysolutions iv got permanent Live and neutral, then blue in common brown in 3 i think they just used brown and blue rather than 5 core or whatever,
@cputilitysolutions
@cputilitysolutions 4 месяца назад
@@ericthekingthekingtheking4842 ok you'd need to check if that blue wire in common is a permanent live and the brown in 3 goes back to the switch live on the boiler. If so then it should work
@ChelseaFC190512
@ChelseaFC190512 9 месяцев назад
Can you run the cable from the fused spur into the receiver? Then run a cable from their to the boiler?
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
Yup you can also do it that way too
@staleyfam3801
@staleyfam3801 8 месяцев назад
how to wire the hive to a glow worm energy 30c erp combi boiler
@cputilitysolutions
@cputilitysolutions 8 месяцев назад
Link L-1 in receiver, 3 to RT
@lostinthoughtscalminsilenc8167
@lostinthoughtscalminsilenc8167 4 месяца назад
When do hive need a link?
@cputilitysolutions
@cputilitysolutions 3 месяца назад
When you don't have a Live Out from your boiler
@lostinthoughtscalminsilenc8167
@lostinthoughtscalminsilenc8167 3 месяца назад
@@cputilitysolutions why would you not have a live out?
@cputilitysolutions
@cputilitysolutions 3 месяца назад
@@lostinthoughtscalminsilenc8167 depends on the boiler
@uTAPOUT1
@uTAPOUT1 7 месяцев назад
How do I get the app to then connect
@cputilitysolutions
@cputilitysolutions 6 месяцев назад
If you have trouble just contact hive support
@paulburns8387
@paulburns8387 9 месяцев назад
You don’t need the earth. So you can just run 3 core and put red sleeving round the earth and use that as the ch on.
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
Not allowed to use earth as a live conductor anymore as per 18th edition if I'm not mistaken - but hey I'm no sparks!
@ChelseaFC190512
@ChelseaFC190512 9 месяцев назад
@@cputilitysolutionsyeah that’s true. I did see you don’t need to use the earth tho on another video.
@cputilitysolutions
@cputilitysolutions 9 месяцев назад
@@ChelseaFC190512 yeah the earth isn't needed, but whilst it's there I just terminated it safely 👍🏾
@JayG2K
@JayG2K 9 месяцев назад
@@cputilitysolutions a long as its sleeved and identified as a live conductor. can someone clarify if thats the case?
@martinmcguinness9482
@martinmcguinness9482 9 месяцев назад
The earth definitely can't be used as a live or switch wire its also in the cable for protection and testing (r1 +r2 )I usually run a 5 core cable from the boiler to the controller I just find it easier
@MrRawMonkey
@MrRawMonkey 8 месяцев назад
The Hive won’t modulate any boiler making it a poor choice.
@cputilitysolutions
@cputilitysolutions 8 месяцев назад
👍🏾
Далее
How To Install A Hive Smart Thermostat - Combi Boiler
14:22
3M❤️ #thankyou #shorts
00:16
Просмотров 8 млн
How To Wire | Tado Smart Thermostat | Combi Boiler
18:44
3M❤️ #thankyou #shorts
00:16
Просмотров 8 млн