Whether the goal is to live off the grid or limit demand from the utility, XW Pro offers a robust solar with storage solution that allows the exceptional installer to design around the needs of the customer. In this presentation, Schneider Electric covers single vs. multi-unit systems, system sizing, commissioning, and monitoring.
Note: This session was recorded live on Monday, January 24, 2022 during the 11th annual altE Virtual Solar Conference. Any NABCEP credit mentioned in Virtual Solar Conference webinar session recordings like this were available for people who attended these sessions live, but are not available for watching the recordings here.

Наука

Опубликовано:

 

8 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@marcfruchtman9473
@marcfruchtman9473 Год назад
Thank you for the video and review of the XW Pro. Re: 8msec transfer time, will that work in the case of sudden grid failure as well as brownout conditions? What is the conversion efficiency of the XW Pro? Do you have a directory (categorized by state/region) for installers / resellers that work with the XW Pro product line?
@MarcusXPX
@MarcusXPX Год назад
Great presentation, thank you! I have a few questions, please: Can you connect three of these for three-phase setup (European version)? Will the three-phase setup still work with 48V LiFePo4 batteries? Is the battery voltage customizable, for example to charge up to a higher voltage, like 54 or 58V?
@matthewyow
@matthewyow 2 года назад
Did SE ever release the Backup Control Switch 2200?
@deltapag5051
@deltapag5051 2 месяца назад
Can I connect the grid wired to AC2 input intended to generator? This is because I want to use grid as a backup
@michaelclark2704
@michaelclark2704 2 месяца назад
Do you mean just for battery charging? This would be one of my questions as well. Can I use AC2 to charge the batteries is the solar input is too low? I live in Calif, under MEM-2, and would like to charge the batteries from the grid if necessary, but not run power back to the grid, which would be in violation of my MEM-2 agreement. I am looking at this inverter for an off-grid power system for my Agriculture Water Pumping system. Motor starts are high amperage, and the XW-Pro is, so far, my first choice. Charging the battery, if necessary, from the grid, using AC2, would be a massive plus.
@deltapag5051
@deltapag5051 2 месяца назад
@michaelclark2704 exactly, I want to be 100% sure zero goes back to the grid and I only use the grid if solar is not enough and my battery backup runs low.
@fred8565
@fred8565 Год назад
all systems are going samller, you guys are going big and bulky. and more expensive..
@Tro1086
@Tro1086 Год назад
Smaller isnt always better. Try starting big inductive loads with the smaller, cuter, all in one inverters. The Schneider system is also more modular/customizable since everything is not built into one box. If one piece of a Schneider goes bad, you replace it. If something goes bad in an all in one, you have to replace the entire thing.
@Jon-ie8kk
@Jon-ie8kk Год назад
Many systems are going smaller and grid/internet dependent. Grid dependent is not what anyone with some foresight is looking for in a home power system.
Далее
小天使和小丑离家出走#short #angel #clown
00:36
Going Solar? Watch this torture test!
22:54
Просмотров 32 тыс.
InsightHome/InsightFacility Setup & Commissioning
20:53
Wiring the transformer based Schneider XW PRO and PDP
28:41
XW Pro vs Sol Ark
23:10
Просмотров 32 тыс.
Giv Energy All in One Battery Review
15:24
Просмотров 1,4 тыс.
InsightHome and InsightFacility Launch Webinar
20:25
Choose a phone for your mom
0:20
Просмотров 6 млн
Подключил AirPods к Xbox
0:45
Просмотров 22 тыс.