If you are using thermostatic radiator valves and you would use an external power source like and H&T instead of the internal sensor within the TRV, this video explains how it is done.
This works with the newer Shelly Plus H&T.
TRV: shelly.cloud/s...
Plus H&T: shelly.cloud/s...
Chapters:
0:00 Intro
2:04 TRV settings
2:45 Fixed IP
3:33 H&T settings
6:24 Outro

Опубликовано:

 

17 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 16   
@fredericrochat3079
@fredericrochat3079 Год назад
Thank you so much for this short, clear and simple video. This is exactly what I had been looking for and I finally managed to link my Shelly Plus H&T to my TRVs.
@MarcoS-cw6rl
@MarcoS-cw6rl Год назад
Very useful video, thank you so much !!. After having installed the valve in a convector (a box with an heat exchanger) it was necessary to completely exclude the valve internal sensor using only the H&T external sensor input. I solved the problem simply by checking the option "enable under floor heating mode" in the TRV settings.
@g7mks383
@g7mks383 Год назад
Thanks interesting. I did this with sonoff units by using séances and it has been working well with two rads.
@olesandersen4126
@olesandersen4126 Год назад
Hello again Thank you thank you. Got it working now😀🙏
@zyghom
@zyghom Год назад
I've installed Tuya based zigbee TRVs at home and since I have in each home also temperature sensors, I put them all in Home Assistant and I made the entire calculation and control in Node Red. So the sensor and the TRV don't see each other - TRV is simply controlled by HA. Much easier. The TRV temperature easily climbs to 28C when it gets open and the boiler is ON while real temperature in the room is still 17C. The problem with the calibration or offset is: the delta (between temperature measured by TRV and the real temperature in the room) is NOT constant. So setting up the fixed calibration is totally useless.
@csongorvarga
@csongorvarga Год назад
That is try, but I made this video for users who have no HA or Node-Red. So for them this solution is much easier. If you have your home automation server, of course you can do anything. But in my example you just need these two devices and nothing else. And it takes 5 minutes to do.
@laymelek
@laymelek Год назад
I just got the H&T (not the plus, just the normal one) and in the settings there is no webhooks.. Do I need to do something to activate it?
@csongorvarga
@csongorvarga Год назад
It is under settings and called I/O Actions, and also Sensor Actions. It was not called Webhook in earlier models.
@squalazzo
@squalazzo Год назад
a note: setting a static ip on a device is NOT THE SAME than making a dhcp reservation... your router will NEVER know you already used an ip address and could then assign it to an other device, causing unpredictable issues... unless you restrict the dhcp range and then you're sure that taking ip out of that range, these will never be used by the dhcp...
@remixedMind
@remixedMind Год назад
correct, best way is dhcp reservation in the router
@omidmohseni6294
@omidmohseni6294 Год назад
how should you set it up if you have 2 TRV's and 1 H&T device in one room?
@csongorvarga
@csongorvarga Год назад
You can add multiple urls to the same action on the H&T. Url will be almost the same, just different IP.
@Loci1987
@Loci1987 Год назад
Hello, Do you know if old shelly H&T can be paired with shelly TRV to use as an external sensor?
@csongorvarga
@csongorvarga Год назад
My old H&T battery died, it took me some time to find new batteries. But now I could check and this does not work with the old Shelly unfortunately. There is a similar I/O Action, but it does not send the data in the same format as the TRV expects. So only the new H&T.
@Loci1987
@Loci1987 Год назад
@@csongorvarga : bad news, however i think it's possible to send webhooks with homeassistant, so i can bridge this problem. Thank you for the reply!
@csongorvarga
@csongorvarga Год назад
@Loci1987 yes you could do this. Just re-format the data and url in HA.
Далее
Best ePaper WiFi Humidity and Temperature sensor?!
12:52
معركة من أجل العصيدة 👧ضد🪳
00:26
7 Days Stranded In A Cave
17:59
Просмотров 37 млн
女孩妒忌小丑女? #小丑#shorts
00:34
Просмотров 21 млн
Use MQTT with Shelly Plus H&T
15:36
Просмотров 8 тыс.
Smart thermostatic radiator valve from Shelly
22:53
Просмотров 4,2 тыс.
Make ANY Device Smart (Shelly 1 PM & Home Assistant)
15:16
SMART Temperature Sensor Shelly H&T
8:55
Просмотров 17 тыс.
SHELLY TRV - Smarter Heizungsregler mit App und WLAN
7:02