@docness7
@docness7 2 года назад
I love the music playing in the video.
@SprinklerWarehouse
@SprinklerWarehouse 2 года назад
Thank you!
@paulhamilton9411
@paulhamilton9411 2 года назад
Great video. Thanks for the help!
@docham
@docham 3 года назад
VERY IMPORTANT to open the downstream Backflow Preventer valve SLOWLY.
@stefanjairrobalino3066
@stefanjairrobalino3066 Месяц назад
What if main line from city is copper ?
@logansneed2882
@logansneed2882 2 года назад
Makes my skin crawl to see the above ground back flow, I’m a young guy and wasn’t taught like that! That’s the new way.
@robertlam5507
@robertlam5507 2 года назад
Where do you out the backflow?
@logansneed2882
@logansneed2882 2 года назад
@@robertlam5507 Tap it off the water meter and bury it in a box, I dont understand why people put it above the ground on the side of the home.
@robertlam5507
@robertlam5507 2 года назад
Here in Illinois we cannot use PVB’s we have to use RPz backflows. The cannot be buried under ground. They can be out in a basement or a boiler room. If you install a RPz indoors it must have a drain pipe below the dump at least 11/2 times the size of the RPz backflow. We are not allowed to use “douable check valves either. I think every state has it’s own codes.
@logansneed2882
@logansneed2882 2 года назад
@@robertlam5507 Probably so, in some states do you have to have a plumbing license?
@robertlam5507
@robertlam5507 2 года назад
@@logansneed2882 yes. In Illinois it takes a licensed plumber to install and test them. In Missouri I have a license to test and repair them. The unions in Chicago set the rules for Illinois and keep us Irrigation guys from testing.
@greenEyezAZ
@greenEyezAZ 8 месяцев назад
Great video. Also what is the song..
@jhogan1960
@jhogan1960 11 месяцев назад
Is a PVB adequate backflow prevention?. RPZs are mandatory in our area
@AlabanzasyAdoración7
@AlabanzasyAdoración7 Год назад
If my line supply is 3/4 do my lines to my zones have to be the same or can they be 1"?
@AlabanzasyAdoración7
@AlabanzasyAdoración7 Год назад
If my line supply is 3/4 my back flow preventer has to be the same or can it be 1"?
@roberturibe2988
@roberturibe2988 3 года назад
What size pvc they using? 3/4? Schedule 40?
@keystoneplumber
@keystoneplumber 3 года назад
They said 1 inch
@luernesto74
@luernesto74 4 года назад
Im looking for the shutoff valve to the sprinklers but i can't find it! Where could it be?
@francej9754
@francej9754 4 года назад
Where ever the previous owner put it 😂 if they didn’t mark it or put a cover on it just have to back track the sprinkler system and locate it. Big headache
@Jehucurliss2kings
@Jehucurliss2kings 4 года назад
Usually by meter or house. Inntx usually underground in box. Usually near water meter (best) or house (amateur).
@Jehucurliss2kings
@Jehucurliss2kings 4 года назад
In tx usually underground. Not a pvb but a dca. Usually in a box. Sometimes no backflow preventer at all. When illegal is ok......illegal is what you get.
@Jehucurliss2kings
@Jehucurliss2kings 4 года назад
Ya. Everyone seems to think that 1 inch main is way to go. Many times , if large residential and or low pressure - Good idea to go 1-1/4 inch sometimes. Or even larger depending on meter size. This one size fits all is getting old.
@noeeon9910
@noeeon9910 3 года назад
1" usually does the job, I hardly ever see the reason to go above 11/4" 11/2" hardley improves your pressure but cost more and is harder to work with.
@Jehucurliss2kings
@Jehucurliss2kings 3 года назад
@@noeeon9910 Hardly improves your pressure? I've done repairs on hundreds of systems. Bad advice
@noeeon9910
@noeeon9910 3 года назад
@@Jehucurliss2kings I'm a licensed irrigator and licensed backflow tester. You done hundreds? I've done thousands... the amount of friction loss that happens in a 11/2 pipe is not that much of a drop from 11/4 look it up on your pressure loss charts if you know what those are. Therefore the benefits of using 11/2 aren't many...
@Jehucurliss2kings
@Jehucurliss2kings 3 года назад
@@noeeon9910 Have you ever designed a commercial system ?
@Jehucurliss2kings
@Jehucurliss2kings 3 года назад
I see now that your main point was pressure loss between 1 1/4 and 1 1/2. My main point of disagreement was your statement that 1" usually works. Depends on size of system.
@robertlam5507
@robertlam5507 2 года назад
Why do you not put unions on the PVB so that they can be taken off for the winter? What a waste of time and money to wrap insulation around the pipes. Also why not put a ball valve on the upleg pipe so you can shut it off at the backflow in case you have to replace it?
@bygonebob
@bygonebob Год назад
I agree with the unions. Exposed pipes (above ground) and capped off will break when the water inside freezes and expands, so it needs to be wrapped. In the video, it showed a shut-off valve was installed right after it teed off the main line in case you've missed it.
@Jungla694
@Jungla694 Год назад
Title of video is not accurate (incomplete).
@crocpa
@crocpa 4 года назад
Horrible music
@docness7
@docness7 2 года назад
You don’t know music.
Далее
How to install a new water main line and shut off valve
18:35
Sprinkler System Install - Overview
9:55
Просмотров 301 тыс.
skibidi toilet multiverse 042 Trailer
01:57
Просмотров 1,9 млн
This mother's baby is too unreliable.
00:13
Просмотров 7 млн
Install Irrigation Valves Locations
14:08
Просмотров 42 тыс.
How To Install The Most Advanced DIY Irrigation System
16:27
How to Clean Sewage with Gravity
11:51
Просмотров 1,6 млн
We Test 3 Ways To Set A Fence Post (1 Winner)
22:23
How to Install Freeze Proof Sprinkler Water Supply
8:09
Trenching, Pipes, & Sprinklers
9:07
Просмотров 702 тыс.