@strunkmp
@strunkmp 11 месяцев назад
The best explanation of measuring duct static pressure out there. And I have watched them all. Thanks
@abledistributors
@abledistributors 11 месяцев назад
Thank You ! please stay tuned, more fun videos like this coming, hope you check out some of our other videos, stay well.... Brian
@gabrielm9391
@gabrielm9391 16 дней назад
Man great video! It all became so clear to me after watching this. Thank you for such a great explanation and keeping it short and simple
@abledistributors
@abledistributors 15 дней назад
Thanks for checking out the video, I've got a million ideas for videos, just need more time, stay tuned more on their way ... Brian,
@davidjensen4654
@davidjensen4654 6 месяцев назад
Great explanation of static pressure and ductwork design. Very helpful for a GC superintendent. Thanks
@abledistributors
@abledistributors 6 месяцев назад
Thank You ! more to come, working on more videos this week.. Brian,
@StepehenA
@StepehenA 2 года назад
Nice job Brian. Good review of the basics. - American Weathermakers
@briandaleske9140
@briandaleske9140 2 года назад
thank you, more to come.
@Tito-hvac8
@Tito-hvac8 3 месяца назад
Great explanation!
@abledistributors
@abledistributors 3 месяца назад
Thank You, on my list is a few more duct work videos, please stay tuned, more videos soon. Brian..
@thomasjohnson3452
@thomasjohnson3452 9 дней назад
Before drilling holes into your furnace....see if you can unscrew the heat exchanger high limit switch for TESP probe access.
@abledistributors
@abledistributors Год назад
Part Two is up on our channel now.
@Gabriel-vz7ml
@Gabriel-vz7ml Год назад
Thank you.
@abledistributors
@abledistributors Год назад
I'm working today on some new videos, so keep checking in, more on tools and procedures .. thanks for checking out our videos !
@tech2tech672
@tech2tech672 Год назад
part two is up now
@tgriebe
@tgriebe 6 месяцев назад
Excellent
@abledistributors
@abledistributors 6 месяцев назад
Thank You, working on more videos, some diagnostic , some installation... stay tuned.
@jakebrown3769
@jakebrown3769 2 года назад
Great video
@briandaleske9140
@briandaleske9140 2 года назад
Thank you so much, we have a lot more videos coming soon, stay tuned.
@tech2tech672
@tech2tech672 Год назад
Part two is up now..
@abledistributors
@abledistributors Год назад
new video up now, duct sizing made simple, check it out..
@rtsolution11
@rtsolution11 11 месяцев назад
I am fighting my system currently which is what brought me here. I purchased a nice set of field piece wireless probes. I am upwards of .89 tesp with the majority in my return duct. .12 in my supply, .21 a coil, .10 filter, remainder is supply ductwork.
@chrisbouse4266
@chrisbouse4266 Год назад
Great video very knowledgeable
@abledistributors
@abledistributors Год назад
thank you, working on new videos, keep watch
@tech2tech672
@tech2tech672 Год назад
part two up now
@abledistributors
@abledistributors Год назад
new video up now, duct sizing made easy, check it out..
@coolramone
@coolramone Год назад
4 probes: A. Top of heat exchanger (box), B. Bottom of blower fan (box), C. Top of coil (box), D. Before Filter.
@peterrivas08
@peterrivas08 Год назад
Could it have also been a problem with supply blower? Weak motor or wrong blower speed?
@abledistributors
@abledistributors Год назад
actually if the blower wheel was dirty ( dirt packed in the blades ) the blower would move less air, and the static pressure would be lower, also if I had lowered the blower speed, it would have decreased the static pressure. static pressure builds when we try to move air through restricted duct work. in my experience most causes air a very dense filter media, not enough return duct or return openings, a dirty A-coil... those are what I usually find.
@chodkowski01
@chodkowski01 11 месяцев назад
Look at the filter the engineers design and test their air conditioners with. They use the very light blue filters. Using a filter with a high merv rating causes your fan to use more amperage, running hotter and cutting down its life expectancy and cutting down air flow.
@abledistributors
@abledistributors 11 месяцев назад
YES... I have a video on our channel all about filters, fiberglass to pleated and how they changed airflow. thanks for checking out our videos, Brian.
@rickgonzalez3662
@rickgonzalez3662 9 месяцев назад
So what is the alternative running a fiberglass 1 inch filter that doesn’t catch any particles they’re useless so you pick your poison and you use a pleated filter
@abledistributors
@abledistributors 9 месяцев назад
@@rickgonzalez3662 remember the filters were never intended to clean the air in your home, they were originally added to protect the equipment from getting blocked up, protect the blower wheel and the AC coil... there are options from Honeywell, Generalaire, and AprilAire , these are super wide filters, some as wide as 7", these would be a much better choice in my mind, of course these need to be professionally installed, but your correct, in the end, we all make a decision.
@rodlasher8478
@rodlasher8478 3 месяца назад
Is a good rule of thumb for static filter drop of .5 differential a good indicator to change your filter
@famousdude1239
@famousdude1239 10 месяцев назад
Doesn't a step bit let metal cuttings drop into the furnace and into the fan motor windings?
@willpartin622
@willpartin622 Год назад
Thank you for all your great vids. I was wondering if you can ever have too much return ducting. After watching your videos, I checked my external static and found 3.5 and 3.5 for a total of 7 in WC . Filter drop is .18 INWC ( 5 inch air bear) and a\c coil drop is .21INWC. ( 2.5 ton N coil.) The temp rise is 70 degrees in heat mode. Rheem says 40-70 rise is okay , so I'm at the high end of acceptable . Shooting for 55 degree rise. I'm thinking I might need more returns and supplies but don't want to over duct it. Any help or advice? Also, when is was installed they added one 10' and one 8 inch flexible return duct. this is a 70,000 BTU Rheem 95% that replaced a 115,000 Ruud 95% furnace. Thank you Reply
@abledistributors
@abledistributors Год назад
your temp rise is a bit high, your correct 55 or 60 would be much better. the N-coils do have more restriction. I don't think you need to worry about too much return, you might be able to get better performance by taking the Flex Duct returns and running them in hard pipe. I've never had a system be perfectly balanced like you have ( both the supply side and return side have same TSP.
@johnwhite2576
@johnwhite2576 13 дней назад
Isn’t it preferable to have more of your total external static on supply side for velocity and throw?
@JohnnyJr396
@JohnnyJr396 Год назад
Thanks for this. Is it true that TESP will get you in the ballpark for blower speed settings but you’ll need other tools to test capacity and actual cfm?
@abledistributors
@abledistributors Год назад
testing your total static will just let you know how well your duct work is performing, knowing this will give you an idea of where to start. actual CFM is a different measurement, I will be coming out with future videos on how to measure CFMs and simple temp rise blower adjustment. I did this video because as we get into more advance modulating equipment, like the Bosch IDS, airflow is very important, more videos coming soon.
@JohnnyJr396
@JohnnyJr396 Год назад
@@abledistributors Thanks! Is it safe to assume I can have the right CFMs and have too high TESP causing more work on the blower and noisy air from duct? So TESP is still a relevant test other than finding blower speed setting?
@nelsonflores67
@nelsonflores67 21 день назад
Great video, question how do you calculate, or where can i get the info when the sp is higher? How less of cfm and temp rise will get?
@abledistributors
@abledistributors 18 дней назад
most brands either in the set up instructions or even inside the blower door, there will be a chart showing you the blower speeds and how many CFMs will be at different static pressures, and some will include the temp rise at that speed and static. hope this helps, stay tuned, much more coming.... Brian
@tommeyers974
@tommeyers974 Год назад
Nice work on the video! I am confused by my bypass humidifier. Any thoughts? Thanks. Tom
@abledistributors
@abledistributors Год назад
just my thoughts on a bypass humidifier.... if your duct work is adequate ( you have plenty of supply and return ) you "should be fine" but if your home is like many, where they're just short on return, you'll end up bring much more air through that bypass than you would want. temp rise with the bypass damper open VS. closed may indicate how your system is working. I would check your static with bypass damper closed. I don't know if I helped or hurt with your question.
@tommeyers974
@tommeyers974 Год назад
TNX. My manometer and probes come tomorrow. I shall measure everything every which way. Then I'll know more.!!
@jaysims7983
@jaysims7983 Год назад
Thanks for a great video. Do you conduct the test in heat mode or just fan mode? Temperature will affect TESP. Correct?
@abledistributors
@abledistributors Год назад
typically I would have it on the highest speed, ( on heating speed I usually check temp rise )
@jaysims7983
@jaysims7983 Год назад
@@abledistributors Thanks for your response. However, I am still not 100% clear. Should I have the thermostat in heating mode or simply run the fan to test TESP?
@abledistributors
@abledistributors Год назад
@@jaysims7983 sorry, yes fan on would be great, make sure all the supply registers are open, clean filter, check if you have supply dampers in your supply ducts, make sure they are open, if you have a bypass style humidifier, make sure that damper is closed. last thing is to check return grills to make sure they are free from anything blocking them. so yes, thermostat to off ( no heat or AC ) fan mode to On.
@michaelfassino4314
@michaelfassino4314 7 месяцев назад
Help please. My static is hi and the issue is with return side. Can I add return air to the other side of the furnace to make a dramatic effect and get that static number down ? Thanks for helping !!! Mike
@abledistributors
@abledistributors 7 месяцев назад
yes you can always do dual sided return, on some larger furnaces it's recommended by the manufacturer , remember you would need to add another filter to that side, and always get return air from the living space and not from the mechanical room or unfinished basement. when I'm searching for the issue, I look at the entire return duct system, from the duct size to how many returns are taken off that duct, adding return is always a good thing, finding where in your home you can put that new return is often the problem, I would never just cut a hole in the duct work, pipe it someplace, even if it's in the floor. good luck, hope this helped a bit. Brian
@michaelfassino4314
@michaelfassino4314 7 месяцев назад
@@abledistributors thank you !! And yes I will have the other side adapting to a joist space and terminate to a floor grille with large openings and the filter for this will be at the furnace. One more Question if I may All my in the wall return grilles are up high on the 9’ wall Do you think that causes restriction too much compared to grilles close to the floor ? Mine are 6x14 with 1/3 fin spacing and there are 9 of them and I want 1000 cfm (2.5) ton ac and 92% 60k furnace
@michaelfassino4314
@michaelfassino4314 7 месяцев назад
A little more info if you would like. My one return drop is a 10x20 with 16x20 x1” filter which I’m switching to fiberglass but my return static is .4. On the supply side I have a “n” style coil and good size ducting and supplies for 2.5 ton
@pauln4dmeedwards775
@pauln4dmeedwards775 Месяц назад
WELL GET YA MATH RIGHT A IS -.22 + .39 = .17 NOT 61
@abledistributors
@abledistributors Месяц назад
when your calculating total static pressure, you add the two results, even if one is a negative number, because the amount of suction needed and the amount of built up pressure both equal the total static pressure, I'll re-watch this video to make sure I mentioned that. but thank you for checking out the video, stay tuned, much more to come.. enjoy your day, Brian.
@fernandorosillocorrales6331
@fernandorosillocorrales6331 12 дней назад
- just means suction, + just means supply. Just have to add both results.
@will-smith-nh
@will-smith-nh Год назад
Excellent
@abledistributors
@abledistributors Год назад
thanks for the comment and thanks for checking out our videos, work has been crazy, but more videos coming.
Далее
Tech Tips: Static Pressure Testing Part 2: Airflow
9:24
Static Pressure and Manometer Basics
32:33
Просмотров 166 тыс.
I Missed With The Bottle😂
00:12
Просмотров 2,5 млн
Air Duct Calculation explained
9:37
Просмотров 38 тыс.
Static Pressure Testing and Mapping Demonstration
11:05
Furnace air flow & BTU's using static pressure
16:09
Static, Velocity, and Total Pressure Explained
4:47
1" Pleated Filters:  The Silent Killer of HVAC Systems
10:58
Do Pumps Create Pressure or Flow?
10:38
Просмотров 1,4 млн
HVAC Static Pressure Testing
4:59
Просмотров 90 тыс.
I Missed With The Bottle😂
00:12
Просмотров 2,5 млн