Teco L510s VFD, remote mode, 2 wire control, 3 wire control and potentiometer set up. For manuals, parts and related videos, please see below.
Teco l510s manual: teco.com.sg/wp-...
Teco L510s Drive: www.ebay.co.uk...
Direct contact on Linked in: / ingus-sudints-1b2a2517a
Website: igselectronics...
eBay store: www.ebay.co.uk...
Teco L510s VFD, local control, commissioning, parameter set up, Factory reset: • Teco L510s VFD, local ...
Run a 3 phase motor on single phase power, basics: • Run a 3 phase motor on...
Single phase to 3 phase VFD drive home setup: • Single phase to 3 phas...
Single Phase / Tree Phase Inverter 3 Wire Control Station: igselectronics...
Single Phase / Tree Phase Inverter 2 Wire Control Station: igselectronics...
Multi frequency control Station: igselectronics...
MOP/Electronic Control Station: igselectronics...

Опубликовано:

 

24 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@burbman60
@burbman60 3 года назад
Great Video, thank you. I have put a 510 on my Milling machine 240 single phase to three phase for 2.2Kw motor. Working well. Adding a remote.
@IGSElectronics
@IGSElectronics 3 года назад
Thank you. Glad it helped you out.
@burbman60
@burbman60 2 года назад
purchased the control from you, looking forward to the safety it will offer.
@jgfpv3179
@jgfpv3179 Год назад
For the 3 wire control set up , what do I need to program into the L510 for 03-01 ( S2 ) and 03-02 (S3) ?? The rest of the video answered all my questions an was really apreaciated so thanks for posting !!
@paulieg9840
@paulieg9840 3 года назад
Hi, and thanks for the very helpful video. I am using the 3-wire control mode for remote on/off and forward/reverse, with an added Rapid Stop switch. The other functions work fine, but when I wired the Rapid Stop switch to S-4, as shown in your video, the motor would not stop when the switch was engaged. In the Group 3 parameters, my manual (Ver 01: 2015.08) specifies "Setting-S5" for Rapid Stop. So, when I wired the Rapid Stop switch to S-5 it worked perfectly. Maybe I have an older version of the L510, or maybe I missed something. Anyway, everything works great and I couldn't have done it without your help. Thanks.
@IGSElectronics
@IGSElectronics 3 года назад
Hi There. Its hard to tell were you went wrong, got to be something simple. Retrace your steps and as shown in video, it should work. Aging it would be hard to diagnose without seeing the setup.
@MrZX1206
@MrZX1206 2 года назад
Paulie G, I encountered the exact same problem. I have my wiring hooked up just like this video and my Rapid Stop decelerates slowly over a few seconds. I went in and turned -15 & -17 down to 0.5 and it didn’t change anything. I found your comment and moved my wire from S3 to S5, programmed the input and it works perfectly. Thank you so much for adding this. I’d resigned myself to having the E stop break the common wire which does cause the motor to stop, but when the E stop button is reset the motor immediately starts running again. Your S5 solution cured it. I don’t see in my manual where S5 is called out, but you found it. It looks like any of the inputs can trigger the E. S. but apparently that is wrong.
@MrZX1206
@MrZX1206 2 года назад
@@IGSElectronics I don’t think he did anything wrong. Mine works the same way.
@IGSElectronics
@IGSElectronics 2 года назад
@@MrZX1206 Good work.
@paulieg9840
@paulieg9840 2 года назад
@@MrZX1206 Hi, glad my experience was helpful. No idea why the setup in the video worked with S-4 (and it clearly does), but ours only worked with S-5. Nevertheless, this video was really helpful. I had purchased a remote control with on/off, forward/reverse and speed control, and I was scratching my head about how to wire it up and connect it to my VFD when I came across this video. My lathe has been running like it's supposed to for the last few months so I am happy.
@jerjesnova8560
@jerjesnova8560 2 года назад
Hello, your videos are very good, with them I was able to start up this equipment but, I still have one more question, I need to program the motors to turn on and off automatically. I know that the real time clock exists in some equipment, but I don't know if the DC1 have this option. Can you help me with this?
@michaelmaloney1027
@michaelmaloney1027 2 года назад
Thanks for a great video. I am building my own enclosure for all the controls and I wondered where you purchase your individual switches and potentiometers?? Thanks for your assistance Michael
@IGSElectronics
@IGSElectronics 2 года назад
Hi there. These are standard Schneider electric gear. Any industrial electronics parts seller should have them. I got mine from RS Components.
@michaelmaloney1027
@michaelmaloney1027 2 года назад
Thanks
@ScottKershawRX
@ScottKershawRX 2 года назад
Please excuse my very novice questions or point me to a more elementary resource. I have the L510 that I am planning to use in the USA as a 110v, 1-ph input and 220v, 3-ph, 1-hp output for a variable speed wood lathe. I want to have a E-stop button, a forward and reverse option and a potentiometer. Would you suggest the 2 or 3 wire setup? If so, I don’t grasp the wiring differences. Also what type of wire do you use to go from VFD to the remote console. Additionally, why are the switches on 24v (the “S” terminals) and the varying frequency potentiometer on 10v? I ask your gentleness as I am not electronics savvy. Thank you, Ingus!
@IGSElectronics
@IGSElectronics 2 года назад
Both options are good, with 3 wire you have standard start stop option that latches the input once the start is pushed and stopped by pushing stop, with 2 wire you have to use selector switches to keep inputs on. The wire from control station to the drive is multicore 12 core cable, 0.5mm size. The analog input standard is 0-10V or 4 to 20ma as standard, and all digital inputs are powered with 24v dc supply's. Hope that helps.
@Jesse-xj5rb
@Jesse-xj5rb 3 года назад
You didn't really cover the magnetic converter? could you clarify the wiring for that?
@IGSElectronics
@IGSElectronics 3 года назад
Hi Jesse, what do you mean by magnetic converter?
@amphibiousmarineinc
@amphibiousmarineinc Год назад
Where can I get a pendant like that is the USA? I can't find that Scheinder product.
@IGSElectronics
@IGSElectronics Год назад
Hi There. That product is built by me with Schneider components. I have discontinued building them as the parts were getting too expensive.
@steveeber2324
@steveeber2324 Год назад
I'd really like to use this information, but I can't understand a word. Between the lousy microphone and the accent, I just can't get anything out of it.
@DK-vx1zc
@DK-vx1zc Год назад
Turn on CC
Далее
Allen Bradley powerflex 4m parameter settings.
10:28
Просмотров 3,1 тыс.
#JasonStatham being iconic
00:38
Просмотров 405 тыс.
How to win a argument
9:28
Просмотров 472 тыс.
Parameter setting for D700 Mitsubishi inverter
2:20
Просмотров 17 тыс.
What Types of Motors Can Be Used with VFDs?
6:58
Просмотров 71 тыс.
How to wire up remote/external switches to a VFD
21:30
Просмотров 153 тыс.
Lathe VFD 5: How to Build an Electronics Enclosure
33:43
Lathe VFD 3:  How to Fix Noise Problems
21:35
Просмотров 172 тыс.
#JasonStatham being iconic
00:38
Просмотров 405 тыс.