Upgraded Fusebox Change the Game with New Three Phase Distribution Board Range
Fusebox changed the electrical market for consumer unit installation with their single phase boards. Now they're poised to do the same for commercial and industrial electricians with their Three Phase Distribution boards.
Will the new TPN dis-boards live up the high standard set by Fusebox, offering quality and availability at an affordable price point?
Joe Hammond takes a dive into some of the features and benefits of this new range of dashboards, including the absolutely game-changing door that will make electricians' lives easier.
🕐 TIME STAMPS 🕕
======================
00:00 A trip to the wholesalers
00:21 Fusebox changes the domestic installation market
00:50 Fusebox moves into the commercial and industrial market
01:07 Joe's first thoughts on the Fusebox Three Phase Disboard
01:23 What's inside the board? Three Phase SPD as standard
02:04 A key feature, no more wrestling doors into place
02:26 Lots of space for wiring in the distribution board
02:54 Joe's key feature, a tough board
03:15 How easy is the Fusebox DB to install?
04:00 Pan-end stops, an absolute game changer for electricians
04:31 Compatible 10kA and 6kA MCBs
04:47 Can the Fusebox TPN DB be used on domestic properties?
05:29 Futureproof your electrical installation using this great device
05:58 Stackable units, room for expansion
================================
📍SUBSCRIBE TO THE CHANNEL eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry.
hub.efixx.co.uk/youtube-subscr... ================================
📺 NEW TO THE EFIXX CHANNEL Watch our essential videos playlist hub.efixx.co.uk/essentials​
📺 CATCH UP ON THE LATEST VIDEOS
hub.efixx.co.uk/latest​
📺 ELECTRICIANS' TOOL REVIEW
hub.efixx.co.uk/tools​
================================
🔴 eFIXX LIVE Join us for our youtube livestream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter. NEXT STREAM HERE
👉hub.efixx.co.uk/next-live-stream​
Catch up on previous episodes
👉hub.efixx.co.uk/livestream​ ================================
🆕 FREE CPD Learn about new applications, regulations and best practice with our FREE CPD modules. - New modules released every month covering everything from surge protection to lighting hub.efixx.co.uk/CPD​
================================
📝 APPRENTICE HUB If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams. hub.efixx.co.uk/apprentice​ ================================
📩 eFIXX NEWSLETTER Sign up to find out about our live events, competitions and product giveaways.
www.efixx.co.uk/sign-up​ ================================
FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
🟠 INSTAGRAM hub.efixx.co.uk/Instagram​
🔵 LINKEDIN hub.efixx.co.uk/linkedin​
🟣 FACEBOOK hub.efixx.co.uk/facebook​
🟡TWITTER hub.efixx.co.uk/twitter​ ==================================
❌ This content on this channel is for electrical professionals.❌ ==================================
📹 Presented by
Joe Hammond - Renewable Technologies Editor
===================================
#fusebox #threephase #electricians

Наука

Опубликовано:

 

1 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 38   
@olly7673
@olly7673 6 месяцев назад
It's good that they have included spare screws but why they can't incorporate captive screws is beyond me. Bcause, we know that after commission those spare screws will be nowhere to be found in the future when needed
@timballam3675
@timballam3675 6 месяцев назад
If it had a glass door like the Hager I would have installed one in my home but I might get one for my office/workshop when I upgrade the supply to 3phase next summer 😁
@miller4eyes
@miller4eyes 6 месяцев назад
The Hagar 3 phase with the glass door shouldn't be installed in a house as they don't cover regs for non combustible materials. I rang Hagar yesterday about it yesterday. They do an A3 board with full metal door
@brianwood5220
@brianwood5220 6 месяцев назад
WOW Great stuff, this will make a lot of installers very happy. It's an excellent addition to their product line-up. Thanks for sharing, Joe.
@troyboy4345
@troyboy4345 6 месяцев назад
Loving your latest cookbook Tom, keep up the good work !
@davebuchan3136
@davebuchan3136 6 месяцев назад
Very impressed with these boards, installed one 2 weeks ago and for the money they are brilliant
@simonjones7785
@simonjones7785 6 месяцев назад
nice looking board love the finished edge to the cable opening
@edc1569
@edc1569 6 месяцев назад
3 phase, can buy you an extra percent in efficiency charging and EV or running a heat pump, but the problem is the solar inverters and battery systems cost more and often the domestic gear struggles with unbalanced phase use.
@mw0358mw
@mw0358mw 6 месяцев назад
Do they have Type1 spd as an option otherwise can't install on any installs with lighting protection.
@Mladjasmilic
@Mladjasmilic 6 месяцев назад
In Serbia, everything is 3 phase, but 16-25A limiter fuse. So, you have 17kW in theory, but it is go do take more then 11, as you have to have everything balanced.
@michaelraab5669
@michaelraab5669 6 месяцев назад
Are UK installs required to switch the neutral at the main CB? Why a 4-pole switch?
@IAmThe_RA
@IAmThe_RA 6 месяцев назад
Safe isolation procedure requires N and L conductors to be open. Double pole MCBs (breakers) are not used in the UK. 5:45 they are the main isolator switch and spd (orange).
@acespark1
@acespark1 6 месяцев назад
No 3 phase board can compete with the Schneider 3 phase board because it has the Merlin Gerin Isolated buss bar, safest on the market bar none and the new one has the neutral connection built in as well. Although you do have to use the knee chin and forehead method to fit the front cover then try not to lose the tiny screws for the cover or the even smaller screws that fix the neutral cover.
@arcadia1701e
@arcadia1701e 6 месяцев назад
Issue is the price.... Hundreds for an empty board. Then £100 per rcbo... That are Single pole..... It's a joke..
@kjgreen3
@kjgreen3 6 месяцев назад
@@arcadia1701e Buy cheap get cheap whether it's chint, mcg, BG, wylex and even Hager. The invictus board is crap and their 250amp mccb panel is even worse. With schneider gear it's expensive but you don't get flimsy poor build quality.
@mw0358mw
@mw0358mw 6 месяцев назад
It's always a race to the bottom for price so this stuff will be thrown in everywhere. We don't install anything other than schneider for the safety aspect with isolated BB.
@SME_Ste
@SME_Ste 6 месяцев назад
Every brand has its place. Shame the old Schneider hasn’t had an update to improve the front cover design thats from 1930😂
@ChooseLife.YourLife
@ChooseLife.YourLife 6 месяцев назад
Put top left screw in first and it will hold perfectly for you to put the rest of the screws in
@killuaHunter
@killuaHunter 6 месяцев назад
here in israel 3x25A phase been provided to homes 20 years ago
@arcadia1701e
@arcadia1701e 6 месяцев назад
Most UK homes dont have 3 phase, but usualy do have 100A single phase at 230v. A lot of new builds are being given 3x100A.
@MarcWilliams-nz4be
@MarcWilliams-nz4be 6 месяцев назад
Some nice features but I think a Schneider board is better
@Mark-xr4zt
@Mark-xr4zt 6 месяцев назад
I wish all manufacturers sold knockout-less CUs, they are never in the right place or the right size and so many boards end up getting butchered.
@tez9302
@tez9302 6 месяцев назад
Are the rcbos double pole ??
@arcadia1701e
@arcadia1701e 6 месяцев назад
The 6ka mini ones ones are.
@grantpatterson1441
@grantpatterson1441 6 месяцев назад
Don't like the fact a 4 way 3 phase dB has a way used up by the mcb for the spd. Hanger bolts on to the main sw.
@Rk-w03
@Rk-w03 6 месяцев назад
Fuse box😂😂😂 can u take em serious with that mascot w his thumbs up
@jameshansing5396
@jameshansing5396 6 месяцев назад
MK is is then? 🤢🤢🤢🤢
@triggsymalone9820
@triggsymalone9820 6 месяцев назад
It a chint board i fitted. 1 lastyear..made in china😊
@sunshine3187
@sunshine3187 6 месяцев назад
I bought a fusebox DB from the wholesalers and returned once i took it out of the box. It felt cheap and poorly built, i should have guessed really after all the social media bods were boosting it 😅
@arcadia1701e
@arcadia1701e 6 месяцев назад
Cheap and poorly built? Compared to what? I find them very sturdy, with lots of space and easy to lay out.
@sunshine3187
@sunshine3187 6 месяцев назад
@@arcadia1701e eaton and shnieder, but even hager.
@ChrisJames-cj8sw
@ChrisJames-cj8sw 6 месяцев назад
100% Eaton Schneider hager not so much there crap these days just feel they skimp more and more always loved Merlin during my apprenticeship we used them all the time now mem or Schneider is the go too on 3° although a scolmore click board is solid plus all the decent features of a well built board
@DJALPHADELTA
@DJALPHADELTA 6 месяцев назад
I'm sorry, I recently fitted a 3-phase board, not enough space allowed on top of bottom for a 32mm gland for SWA, trying to fit a P-Nut to the gland was an awful fit. The video feels very much sponsored, I liked the feel of the box fit and lid but top and bottom just awful.
@johnappleton6842
@johnappleton6842 6 месяцев назад
Lots of features copied from other manufacturers… who have invested in R&D and how can they call this a review… blatant advert or promotion so how can we take it seriously…
@Sparks1Plumbers0
@Sparks1Plumbers0 6 месяцев назад
M8. Totally agree... gone from being an informative channel to a blatant Home Shopping one 🙄. This weeks 'flavour of the day' will shortly be replaced by the next in pretty short order once the sponsorship deal has been agreed. Use to respect these guys in the early days but now with their new team members they've just become a bunch of salesmen trying to flog whatever cross's their path (& their palm with silver)! What next... prices, payment options and direct selling 🤔
@deang5622
@deang5622 6 месяцев назад
1. Features copied: If there has been a patent infringement or copyright infringement then it is down to the complainant to sue FuseBox. So perhaps there hasn't been any infringement. Many products use similar features - just look at how lever terminals are being used in more and more accessories, yet Wago has been using them for years. Do you think other manufacturers should not use this really neat feature? The answer is, it depends if there is any copyright protection on the design. So there is a complete legal framework in place to protect designs and if a manufacturer choses not to take advantage of it, or cannot take advantage because their design is not sufficiently unique, then that's tough. 2. Is this video a genuine review or an advert? That depends on whether eFix have been paid by FuseBox for performing the review, or benefitted in some way. And we don't know the answer to that. In my opinion, if they have been paid by FuseBox they should disclose it.
@efixx
@efixx 6 месяцев назад
Have you checked out all our completely free training packages we offer to electricians? Not a hint of sales in those: training.efixx.co.uk/#/home
@WindyJAMiller
@WindyJAMiller 6 месяцев назад
​@@efixxis this video aaid for advert?
Далее
The Jaw-Dropping Difference Between AC & DC Isolators!
5:39
ATEEZ(에이티즈) - 'WORK' Official MV
03:15
Просмотров 13 млн
Decrypt a Mifare Classic 1K
6:12
Просмотров 9 тыс.
Consumer Unit Explained - Fuse Board
8:04
Просмотров 163 тыс.
Rewire pt3
4:34
Просмотров 418
Power up all cell phones.
0:17
Просмотров 49 млн
Куда пропал 3D Touch? #apple #iphone
0:51
Просмотров 667 тыс.