THEY SAID THE AC IS NOT WORKING AGAIN 

HVACR VIDEOS
Подписаться 188 тыс.
Просмотров 68 тыс.
50% 1

Well they called me back out and said the AC was not working again.
HVACR VIDEOS MERCH WEBSITE - www.hvacrvideo...
Please consider supporting my channel by
Becoming a Patreon member - Patreon / hvacrvideos
Becoming a RU-vid channel member / @hvacrvideos
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideo...
HVAC OVERTIME CHANNEL LINK - / hvacovertime
Social Media
Facebook / hvacr-videos
Instagram / hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Опубликовано:

 

9 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 263   
@nolanferry691
@nolanferry691 Месяц назад
Bro is out here polishing every turd
@75sRax
@75sRax Месяц назад
realest comment out here
@gregmercil3968
@gregmercil3968 Месяц назад
The majority of our work consists of polishing turds. 🤣
@keith_5584
@keith_5584 Месяц назад
*being paid to polish every turd. Less of a hobby, and more like a commandment.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
​@@gregmercil3968exactly, lol
@Pyro4100
@Pyro4100 Месяц назад
@@nolanferry691 there are people out there that polish turds and actually sell them LOL
@grashoprsmith
@grashoprsmith Месяц назад
@09:25 "they're all rubbing out on each other...that's a mess"...😅😳
@jamesnorris1272
@jamesnorris1272 4 дня назад
Mister, you are one Hell of a troubleshooter and technician; I hope your customers realize this when you talk to them about repair vs replacement (even in CA). You are going to get another call on this same unit (I'm an old 'motor man' and, yes, change the blower motor if they'll let you and 'stiffen' the base if you can). Very nice work on repairing, rerouting & securing the control & power wiring (somebody else has been there before you). Ah, and SPARE 60Amp Fusetrons; Abondanza, Brother!
@YuShudNoe
@YuShudNoe Месяц назад
I saw the right fuse discolored right away and knew the disconnect wasn’t making good contact. I win ! Haha . Gotta love HVAC!
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Lol
@darthdzl
@darthdzl Месяц назад
You do realize that, as much as we don't want anything bad to happen, lots of people are subconsciously giddy at the prospect of the magic smoke escaping every time you say "1, 2, 3, please don't blow up". 😁 May that phrase never doom you. (knocks on wood)
@markbeiser
@markbeiser Месяц назад
I tried R-407C in a mineral oil system once about 5 years ago to see what would happen, with the full consent of the owner. It is still working great! Still the only one I'll do that with though.
@Sperkowitz
@Sperkowitz 6 часов назад
I love how you inspect as to why a fuse blew. Many just replace it. Sure something like a rolling blackout or brownout can cause a surge but if not known it's good to try to find out why. It's not always possible and the should call back if something happens again then you know for sure there's a deeper issue that wasn't found the first time.
@davidrogers8401
@davidrogers8401 Месяц назад
Nice to see how thorough you are. Way to go
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@jasonjohnsonHVAC
@jasonjohnsonHVAC Месяц назад
You can see the compressor on the left....the paint is gone on the head of the compressor....she's been cooking that oil a time or two. Looks like those junk accuators are getting slightly restricted. I agree this rtu should be put to bed....permanently
@LastSlovenian
@LastSlovenian Месяц назад
Probably both original ones were cooked and bad, one got replaced, the other soldiered on. One drier seems new one old, so it wasn't a full repair.
@dumptrks
@dumptrks Месяц назад
Damn @jasonjohnsonhvac your so harsh
@markbeiser
@markbeiser Месяц назад
It is the natural state of Carlyle scrolls!🤣
@throttlebottle5906
@throttlebottle5906 Месяц назад
I'd say the right one was replaced/failure/burnout. left likely original. possibly a brownout or phase loss/brownout, banged the fuse. even the wires were all rubbed out, none looked to have shorted. the overheated(blown) fuse could have been poor disconnect contact, either tension loss on the blade or the fuse holders. many had hardened spring steel clips that fail with rust, and age from thermal cycling, once tension is lost game over. that happens often on circuit breakers also, at the end which plugs onto the bus bar, when it breaks and loses tension it start overheating and cooks itself, usually wrecking the breaker case and the panel bus terminal. (aka new panel time)
@Thesecret101-te1lm
@Thesecret101-te1lm Месяц назад
Great video as always! It would cost like $1 to $2 for the manufacturer of the lockout boards to add LEDs that indicate incoming call, outgoing call and a lockout situation. Add $1 more and you could have two color LEDs that gradually switch color to indicate if a call came within the last few seconds, or a lockout happened within the last few second. Not sure if it would had helped in your particular case, I didn't get which order the lockouts and the economizer control thingie are hooked up, but still. P.S. an argument for repairing instead of replacing is that some parts are fairly new and those that have survived for 20 years are probably good enough to survive almost until eternity.
@_iLLuSiv3_
@_iLLuSiv3_ Месяц назад
It's like they get off making people guess!
@markbeiser
@markbeiser Месяц назад
From a manufacturing and assembly cost perspective, I think having an LED to the board, instead of the wire running out to the terminal block, could actually work out to be cheaper at scale...
@LandonShipp
@LandonShipp Месяц назад
You're really good. I am an 18 yr old who has been doing hvacr since his freshmen summer in hs. The cutouts made of the compressors say it all! I'm also trying to get my ham radio operator license. Thank you for sharing this and teaching me so much and being such a great inspiration. THANK YOU!
@raysolovic3629
@raysolovic3629 Месяц назад
Another thing to check is the motor pulley, especially for blown fuses and excess vibration. And yeah that compressor looks like its been overheated for a long time.
@kg4muc
@kg4muc Месяц назад
Thanks for sticking with doing it the right way!
@gdrriley420
@gdrriley420 Месяц назад
I saw that GE distribution panel and electrical space and I was reminded of work in all the wrong ways.
@richardbartlett6932
@richardbartlett6932 Месяц назад
There were times I really enjoyed this kind of mess and others where I thought "Why me?" Great work, you can only do so much but you did way far more than most.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@ThatTransistorGuy
@ThatTransistorGuy Месяц назад
My favorite parts of your videos are when you take apart the compressors! If you could make a playlist of all the videos where you take apart the compressors, that would be amazinggggggggg
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
I'll see what I can do about that when business slows down a bit
@ThatTransistorGuy
@ThatTransistorGuy Месяц назад
@HVACRVIDEOS thanks! I really like this channel! Keep up the amazing work. I learn from every video.
@joselanda8316
@joselanda8316 25 дней назад
Tech - "Sir im going to have to recommend that you replace the whole system" Customer - Why is that? Tech - "Its got gremlins"
@MrJANTJE123
@MrJANTJE123 Месяц назад
These are the video's i love, I love working on old shit fixing it and making the customer happy :)
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Me to, thanks for watching
@ErickHernandez93
@ErickHernandez93 Месяц назад
Possibly just a weak compressor chris, megometer would come in handy Also possible bad crankcase heater, those could also easily blow a fuse, seen it a happen before
@gringoloco543
@gringoloco543 Месяц назад
I actually did have one blow up in my face. I was replacing a Trane contactor with an aftermarket contactor with all the aux switches. I accidentally attached the 24v signal wire to a 480v terminal. The circuit board made a big bang 💥.... I'm new to this industry, BTW... and wondering if I'm cut out for it.
@Jason-wc3fh
@Jason-wc3fh 22 дня назад
Well you identified your problem with why it blew up in your face. Obviously 480v going into 24v is going to make the 24v side very unhappy. You said you're new, so mistakes are going to happen.
@terryh8421
@terryh8421 Месяц назад
I like the way you find weird problems as interesting!
@tirbomax
@tirbomax Месяц назад
always great content on your process to NOT screw the customers...very few true honest people these days!
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@ShukenFlash
@ShukenFlash Месяц назад
It could well have been a combination of all those things. None of them may have been enough to take it down on their own, but if a couple had it right on the edge already any little thing could have tipped it over. I agree, that thing has given them 20 years, it's time to retire and replace it. 20 years is a good run for an AC.
@stevenhorne5089
@stevenhorne5089 Месяц назад
I've never really been conscience of rub outs. But going forward, I always will. I want to go outside and check all the wires in my machine right now.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
May not be a bad idea
@CC-Rider
@CC-Rider Месяц назад
It's not just restaurants it's every places mechanical /electrical rooms. They can't stand the thought of all that space And not one phase monitor to be seen
@Thesecret101-te1lm
@Thesecret101-te1lm Месяц назад
The solution is to have the electrical panels in a place where it's impractical to store stuff, like say in a hallway. That might be against code though.
@CC-Rider
@CC-Rider Месяц назад
@@Thesecret101-te1lm it generally is. Locked restricted access to unauthorized personnel etc space
@jeffmelcher2908
@jeffmelcher2908 Месяц назад
@@CC-Rider I’m with you on the phase monitors missing. My Engineered Air unit has one and it did its job a week ago when we lost a leg during a storm.. Are they uncommon?
@orcus79orca5
@orcus79orca5 Месяц назад
@@jeffmelcher2908 they are, I look after 14 buildings and none have any phase monitoring that I know of, some newer buildings have surge protectors but no phase monitoring, unless there is a stand by generator.
@THEBRAINANAYTOR
@THEBRAINANAYTOR Месяц назад
I remodel Publix as an electrician, and I can confirm. THEY ALL put racks and bins infront of panels and storage in electrical room even though there’s a big sign that says “NO STORAGE PERMITTED”
@LastSlovenian
@LastSlovenian Месяц назад
Unit shorted out due to manufacturer saving cost on 10c zip tie. Whole vibration issue is pulley looking wobbly with uneven wear may have been put on bent or whole shaft is bent.
@thomasmann3560
@thomasmann3560 Месяц назад
I agree with the jade causing the problem. I see the relays on them doing stupid stuff all the time. I'm in AZ so we only bring in minimal fresh air, so bypassing failing jades is common for us
@markbeiser
@markbeiser Месяц назад
I've had to bypass 3 of them this year, hardly anyone wants to fix them. 2 of them never worked anyway, because they were side return units with the economizer installed for return through the curb, and I'm not even going to try to fight the battle of finding the bits and pieces needed to convert them that the installer trashed. I just wish people would leave the damn bypass plug with the unit when they install it!
@thomasmann3560
@thomasmann3560 Месяц назад
@@markbeiser crazy, yeah. I had 1 customer want their jade replaced. We had to get it special ordered thru siglers(carrier) and it took forever. It was so dumb.
@kens.3729
@kens.3729 Месяц назад
This Equipment looks Nothing Short of a Nightmare. Your Strong 💪 Efforts are Appreciated by your Customers and your Viewers. Thanks! 👍🙏
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@Spencer1609751
@Spencer1609751 Месяц назад
That Gap in the disconnect switch knife, Like throwing Hot Dog Down the Hallway!
@misterhat5823
@misterhat5823 Месяц назад
I've heard something similar about dropping a hot dog down a man hole...
@blackfirehd884
@blackfirehd884 Месяц назад
9:22 im sorry im too immature 😂
@joeydinner
@joeydinner Месяц назад
If your blue line voltage wire would have rubbed through with your low voltage, you would have seen an issue with your low voltage. More than likely would have lost a component on the low voltage because with that short, you’re sending 120v or high voltage to your low voltage circuit. Ask me how I know… Thanks for sharing your day to day service calls. I’ve learned a lot here.
@markbeiser
@markbeiser Месяц назад
Q: How many of the low voltage components would fail if that occurred. A: Yes! Most of us have had that particular brain shart. The rest are lying, or newbies that just have not gotten around to it.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks for watching
@robertarnold6672
@robertarnold6672 19 дней назад
That was a tough service call but I learned some really good pointers from this video, definitely things that will make me a far better technician than my coworkers, who do not watch this channel or invest in themselves by taking online classes or going to school. Only problem is that I get hit with all the more difficult calls but you can’t grow from only dealing with the easy stuff. Thanks again Chris for making these videos. My abilities & knowledge have greatly increased since Ive been a subscriber!
@rdalemd76
@rdalemd76 3 дня назад
Here in Maryland, It’s not unusual to see Restaurants Milking a RTU that is 35 to 40 years old. The Request will usually be they want the Unit repaired and how much. What usually forces their hand to replace the RTU is Water intrusion, Compressor failures coupled with known Refrigerant leaks. That seals the deal every time. Good Video.
@peterhodgkins6985
@peterhodgkins6985 Месяц назад
407C absolutely does NOT work well with mineral oil. Good call, Chris.
@PhantomDragonX
@PhantomDragonX 22 дня назад
Yea that's what MO89 is for. if you know it has og mineral oil, don't use a poe spec refrigerant
@davidhoward2282
@davidhoward2282 4 дня назад
407C + SuperChange. I used on a 2 ton rtu 6 years ago still working good.
@leroygreen1877
@leroygreen1877 Месяц назад
When I see those thermal fuses blow its normally resistance issue in the disconnect.
@MrJANTJE123
@MrJANTJE123 Месяц назад
Yea but the breaker tripping also sounds more like a random short. I wonder when he talked about the second time he went there for a blown fuse if the breaker was tripped again.
@russellhltn1396
@russellhltn1396 Месяц назад
@@MrJANTJE123 Maybe the breaker tripped due to single-phasing?
@leroygreen1877
@leroygreen1877 Месяц назад
@@MrJANTJE123 Thermal trips are a pain to diag.
@2packs4sure
@2packs4sure Месяц назад
It's these types of units and situations that made me walk away from commercial air conditioning about 10 years into my career back in 1997.. I was tired of working on garbage that was just one patch after the other on top of the other before I got there.. For the next 20 years it was 98% residential..
@Rico-oy3dc
@Rico-oy3dc Месяц назад
Must be lucky. In my area, all the residential are poor clients and patchwork. Commercial is gravy here in WV upper panhandle
@2packs4sure
@2packs4sure Месяц назад
@@Rico-oy3dc I had a good mix of 90% middle and upper middle class clients with a few shit show customers thrown in,, but very few..
@markbeiser
@markbeiser Месяц назад
It gets real "fun" when the property manager has a "maintenance" guy that takes care of most things, and only calls you after the guy has really mucked it up. VRF systems "maintained" by in house maintenance staff can be pretty extra spicy to deal with.
@2packs4sure
@2packs4sure Месяц назад
@@markbeiser I can only imagine.. lol I saw some incredible shit but 99% of it was analog old school equipment in my day so there were less unknowns and mysteries but still a rat's nest of incompetence to unravel on a smoking hot Houston roof... I DON'T miss it !!!
@raysolovic3629
@raysolovic3629 Месяц назад
I just seen where your blue wire shorted at. On your video at 24:54 look at the door.
@russellhltn1396
@russellhltn1396 Месяц назад
Sure looks like something happened!
@markbeiser
@markbeiser Месяц назад
Certainly looks like something ⚡, but looks too high on the panel, I think the cover over the controls section would be directly behind there.
@Android_Warrior
@Android_Warrior Месяц назад
Chris, leave California and come to Texas!!!!!!!!! 💪💪💪💪
@Android_Warrior
@Android_Warrior Месяц назад
And if you do I will work for you!!!. Just finished my HVAC School.
@paulravitsky2898
@paulravitsky2898 Месяц назад
Before I was retired I was on the safety committee and we inspected for 3' clearance around all electrical. Someone would have been written up for failing to keep the area clear. Heaven forbid someone needs to kill power quickly.
@ShukenFlash
@ShukenFlash Месяц назад
I suppose they could always Ship of Theseus it if replacing it is too much hassle. Just replace every component for new so it's still a "repair."
@trevorphillips7233
@trevorphillips7233 14 дней назад
Gas stations look like that too
@MarkCarpenterHVAC559
@MarkCarpenterHVAC559 6 дней назад
Got an evaporateor change out on one of these next week. Multiple techs have been in this unit over years. It was way over charged, no one seemed to diagnose the plugged accurator's. Low suction add gas. Customer doesn't want to pay for R22. Looking at R422b. If i remember correctly that's like a 10% loss in efficacy. You mentioned not using replacements on a fixed metering device. Compressor has been changed I'm going to dump the compressor it seems like there's too much oil in it. Dripps out of both ports.
@alantorrance6153
@alantorrance6153 Месяц назад
My background is not heat engineering (it is office work, and sundry vehicle repairs), but your programme is quite interesting. Thank you.
@HVACRVIDEOS
@HVACRVIDEOS 29 дней назад
Your welcome
@richardbrooks3569
@richardbrooks3569 27 дней назад
I'm always impressed with your troubleshooting skills.
@HVACRVIDEOS
@HVACRVIDEOS 22 дня назад
Thanks Bud
@Jason-wc3fh
@Jason-wc3fh 22 дня назад
There are several videos from other HVAC guys who show in detail how to they free up the accurators on these evaporator headers. I've done it myself with total success. The labor is still going to be high for the work involved, but it can be done without having to completely change out the evaporator. Some even have TXV's kits available and you can ditch the accurators alltogether.
@brianmcdermott2430
@brianmcdermott2430 Месяц назад
Great info. And troubleshooting. Thank you Chris.
@marcusmcduffie2106
@marcusmcduffie2106 Месяц назад
Hello sir a quick shout out to you for being detailed and straight forward with your process. Thanks to your videos and the BIG PICTURE mindset I installed my 1st belt driven commercial blower motor . Keep doing what you do sir your youtube brother/tradesman from ga appreciate you. God bless you see you on the next one. .
@ehsnils
@ehsnils Месяц назад
At 4:31 I see that the blown fuse is also discolored, which to me seems like it has been running hot for a long time and not just a quick overload. It could be the fuse itself that was the faulty item. That actually happens!
@DelticEngine
@DelticEngine Месяц назад
Interesting and informative video, Chris. That RTU looks like it's been patched up and modified numerous times making it a pain in the proverbial to determine if something is what it appears to be or the result of a 'creative repair' in the past. Regarding the low voltage side, why not get some 24V AC/DC LED indicator lamps and put clips or backprobes on them? Some of these indicator lamps are prewrired and need only suitable termination of the wires. Careful positioning in the circuit would show exactly what is happening and when as well as where any issues occurring. If a camera was set up you would then be able to easily prove what the problem is and what needs replacing to remedy the situation.
@pigalex
@pigalex Месяц назад
This. Cheap automotive/hobby lamps that are rated for 24v DC will also run on 24v AC. Could be a cheap tool to add to the arsenal!
@DelticEngine
@DelticEngine Месяц назад
@@pigalex A very simple and cheap diagnostic tool that doesn't need batteries. It would need to be LED and AC rated up to around maybe 30 volts to account for anomalies. The key objective is minimal loading on the test circuit while being a useful indicator.
@makinbac0n
@makinbac0n Месяц назад
Those disconnect switches are serviceable. Those knives just pull out and you can clean them.
@jrsmyth9761
@jrsmyth9761 Месяц назад
I think you may have said similar, but with Y1 & Y2 both on one terminal and not separate inputs to each CLO there was nothing to activate the CLO to lock out when no amperage was sensed on the CLO. (thinking as I am typing) Freeze alarm may have cleared with the door off by the time you got to the clear alarm section.
@fredlendzian7082
@fredlendzian7082 Месяц назад
you got me saying 123 please don't blow up I like it
@DamagedF0X
@DamagedF0X Месяц назад
I don't work on hvac, but some of the electrical lessons/examples help me in the electrical forklift world.
@karellfernandez73
@karellfernandez73 Месяц назад
When I think :" I'm learning". Then I watch this video and I know that I don't know what I know because I didn't know ttyty24V, +480 ; restrictions @ bad bearing +100, degres😂😂. Now seriously. Thank you for all your videos, as a new technician trying to have the opportunity to work in the field, I'm learning from every single one. Thank again.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
I'm glad these videos help in some small way
@caffeinatedinsanity2324
@caffeinatedinsanity2324 24 дня назад
Seeing the exposed copper on those dangling wires made my teeth grind.
@tundra1017
@tundra1017 13 дней назад
Probably would have shut that door before turning the power on 😅 especially thinking it might blow up
@mikefrom3089
@mikefrom3089 26 дней назад
First thing you said it short cycled the the compressor I knew it was an economizer. I bypassed one two days ago that was randomly cycling the compressor 2-10 times in a a mater of seconds. I had never seen that and the boards don’t lock out because it’s not a safety it’s the control that’s doing it
@colormaker5070
@colormaker5070 24 дня назад
i see you have one of my favorite Simpson multimeter in your office. This was my goto meter before we went digital.
@MelodyMan69
@MelodyMan69 Месяц назад
I would like to see some VRF/VRV AC System diagnostics.
@HVACRVIDEOS
@HVACRVIDEOS 29 дней назад
I'll see what I can do
@nightshadelenar
@nightshadelenar 29 дней назад
new viewer to the channel, however not the first time i've seen some ratty AC units (military legit has some of the more foul ones!) Older units like that one generally are a menace to keep running past 18-20 years due to parts and other things not being made anymore. Just be glad it isn't pouring water into the building! had a residential AC unit in a home i use to live in had it's coil drains fail, where something came loose and plugged up a pinhole drain. Flooded the entire lower level one week and the military housing people didn't want to fix it. Long story short, we got a new floor and a new unit with proper installers after some angry phone calls to managers of managers.
@HVACRVIDEOS
@HVACRVIDEOS 29 дней назад
That sounds horrendous
@krisrosvold5007
@krisrosvold5007 17 дней назад
Kapton Tape is really handy for insulating cable sets, especially in the carrier units. Any electrical supply should have it.
@helmsajr
@helmsajr Месяц назад
Great job Chris has always.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan Месяц назад
If the 2nd fuse to blow was the same one that blew before and was the disconnect knife that's making a poor connection, then the fuse likely blew because the bad knife connection is causing it to heat up and if it gets too hot, the fuse will blow thinking it's passing too much current... Fuses are micro-heaters at heart, the more current they pass, the hotter the fusable link inside them gets and when they get too hot (because they're passing too much current), they melt and a spring pulls the two halves apart breaking the circuit, too much heat in a nearby component (such as the knife blade half an inch above the fuse) will also cause the link to melt, blowing the fuse... When the fuse blew, cutting only 1 of the 3 Phases, it likely caused enough of an Imbalance in the Main Breaker to cause it to trip... In addition to that, I suspect you also have a failing (or outright failed) Jade Module and/or Compressor Lock-Out Board... That's my Theory, though I admit, 3-Phase Equipment, Breakers and Fuses are not my Specialty as an Electrician, my Training and Experience has always been in Residential Wiring...
@LordMondegrene
@LordMondegrene 7 дней назад
I don't understand a damn thing, but these are oddly fascinating... thanks. Subscribed.
@jamestoy426
@jamestoy426 Месяц назад
Worked for a home warranty customer was low on Freon we only use 407c I told the customer he said go ahead 2 weeks later he has a bad compressor I
@Harry1s
@Harry1s 13 дней назад
The blower wheel was very dirty.
@colinclingan8246
@colinclingan8246 Месяц назад
That unit is two years older than me😂. Good grief.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Lol
@ritchieortiz5610
@ritchieortiz5610 Месяц назад
I’ve had an issue with the same kind of unit it was a 2003 or 2004. They had the unit jumped out on running both stages. I ended up cycling the 2nd stage. It was just running for too much for too long. To the amperage would like slowly but surely. I’m here in the Coachella valley so you know the weather I deal with.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Yeah it’s hot out there I only have one customer out that way so I’m hardly ever there anymore
@elcrazy8017
@elcrazy8017 27 дней назад
That restaurant needs a PM contract on those units. They are not taken care of
@HVACRVIDEOS
@HVACRVIDEOS 22 дня назад
So very true
@crazyedo9979
@crazyedo9979 11 дней назад
An investigation with a thermal camera would be nice to see if there are any resistance related electrical problems.😁
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan Месяц назад
Thank you for going back to this Video Intro. Please don't use the music again, it was excessively loud and even more annoying than it was loud.
@Duracellmumus
@Duracellmumus 16 дней назад
Whend i faced so many trouble in unit like this case, i going to do some mechanical integrity checking. If its low the whole unit is going to down often, because the components has disturbed and no chance to do their jobs well and it always causes non-critical isues that way. But when these isues are comeing and going the components gets stressed by eachother and its going to fall most non predictable ways. This is can not be slow down effectivly without get an aceptable mechanical isolation inbetween the problem-sources, to get find them in the usual easy-to-understand work OR not work states. When is achived they going to act as an old component, and start to do their jobs realy well. In this case is lot of effort but take mutch less time compared to fight the seemly “not critical issues”.
@BeastCY2
@BeastCY2 Месяц назад
Very good Teacher. Dont know anything as Im from the IT field but after years of watching you im trying to follow and understand. Thanks for the great videos
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks for watching
@_iLLuSiv3_
@_iLLuSiv3_ Месяц назад
I needed some 409A, now I am converting seals and oil over instead... wow.
@sparkytech8787
@sparkytech8787 Месяц назад
the blue wire ruby duby looked clean thou
@gamingwithmr.fregles8802
@gamingwithmr.fregles8802 Месяц назад
2:39 anyone notice that chopped wire?
@ernestrollins383
@ernestrollins383 2 дня назад
10:00 I think something is bent causing excessive vibration and that is rubbing the wires
@andrewgilbreath1331
@andrewgilbreath1331 Месяц назад
Bro I don't like 407c personally for 22 replacement, I've had really good luck with 422b and MO99 both work with mineral oil, no oil change is much easier to deal with.
@kennethmoore117
@kennethmoore117 14 дней назад
Flex loom for the wire like vehicle
@mikemorassi210
@mikemorassi210 16 дней назад
Where would you find SEER ratings if you didn't know what the seer rating was?
@sphinxios
@sphinxios 11 дней назад
heat up the caps and se if those change value, on the bad ones values will change quite a bit
@ninnghhizziddha
@ninnghhizziddha Месяц назад
Love your videos Chris.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks bud
@bashaaksema94
@bashaaksema94 Месяц назад
I will never understand why they use blank wires in america. Here we would definitly use cables and also have to secure them way better.
@AllTheOne219
@AllTheOne219 Месяц назад
im early to the non member release
@Roctrin
@Roctrin Месяц назад
22:30 mechanical electrical joints like wire nuts arent designed for the kind of vibration seen here. Lots of poor design in wire routing and termination shown in this unit. Really cool stuff, thanks for your content.
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
I agree
@ptza_lord
@ptza_lord Месяц назад
someone said "STOP SELLING!!! YOU NEED TO COOK!!" to the compressor
@HVACMANE
@HVACMANE 8 дней назад
I would see what leg was powering the transformer.
@gregmercil3968
@gregmercil3968 Месяц назад
I had a similar issue today, blank Tstat caused by a tripped breaker. No popped fuses though. I went through the entire system and all I found were a couple of low voltage shorts via wire rub-outs; one was from the defrost termination switch and another was a pressure switch. Not sure how that caused the breaker to trip and not pop the fuse on the board, until I saw that the transformer was tapped wrong. Was tapped for 230 instead of 208. I corrected that issue too, then wondered if maybe that caused the contactor to chatter which could trip the breaker. But the contactor wasn’t burnt up or pitted. One of those weird things that kinda stumped me, but whatever the unit is working fine now. 😆
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
That is Interesting
@asmith1340
@asmith1340 Месяц назад
At the end looks like bare wire showing that someone tried to put tape over that was falling off.
@Pyro4100
@Pyro4100 Месяц назад
If the compressors are three-phase and one fuse blows they would start to single phase and at some point will trip the breaker because of the single phasing had the same issue with air compressors that are three-phase one fuse blows and then eventually it trips the breaker
@m9ovich785
@m9ovich785 24 дня назад
With all the vibration I would have taken a Screwdriver to all The JADE terminal blocks.
@markae0
@markae0 Месяц назад
Nine minute in if you can't wait. Great Video!!!!
@Nba19980
@Nba19980 23 дня назад
Great stuff
@funkydancer4300
@funkydancer4300 Месяц назад
Now, Who noticed the burn/rub-out mark on the panel? 24:55, any one? I may be incorrect but it sure looks like a burn mark.
@gabrielmendoza9165
@gabrielmendoza9165 17 дней назад
19:42 *Tstat gets power from terminal board
@LewisSmith-he6gu
@LewisSmith-he6gu Месяц назад
hello from Poole in Dorset
@lildrastly5512
@lildrastly5512 Месяц назад
Love the videos 👍
@HVACRVIDEOS
@HVACRVIDEOS Месяц назад
Thanks
@theradioweyr
@theradioweyr 24 дня назад
I don't understand the architecture of these commercial units but can we make the Copeland the front line hitter and make the Carlyle second string? LOL.
@sirraident
@sirraident Месяц назад
Quick question regarding oil's and what you stated at the end. Would M099 not be compatible with R22 regarding the oils? If not, then would it be a good idea to flush the lines or blow out the lines with nitrogen or just change the compressor? I just want to know what's best practice, thanks you. I have learned a lot from your channel and I greatly appreciate all that you do!
@HVACRVIDEOS
@HVACRVIDEOS 29 дней назад
Good question, I'm going to try and discuss this further on Monday nights live stream
@whoisderf
@whoisderf Месяц назад
1:22 and hit pause. Ladies and gentleman…..that panel highlights why impact drills are NOT for the average service tech….. Gotta love the entire roll of E-tape around the caps. Hacks.
@markbeiser
@markbeiser Месяц назад
My company has a tech that I don't think ever figured out that the trigger on his impact drill is variable... I've had equipment I worked on for 20 years without stripping a screw, he touches it once and half the screws are falling out on their own next time I'm there.🙄 I don't think I've ever used an impact for panel screws except when I don't have a charged battery for my regular driver.
@whoisderf
@whoisderf Месяц назад
@@markbeiser my favorite is when someone uses their rattle gun on the stainless Philips screws on Greenheck exhaust fans, instantly stripping them to nothing….so the next guy has to bring his Vise Grips and waste time fighting the screws. My rattle guns remain on the truck unless I’m breaking into a large centrifugal chiller. Outside of that, large boilers and Victaulic fittings are the only other times it comes out. On a small package unit, literally zero times in 26 years; completely unnecessary tool for the job at hand.
@thomasmann3560
@thomasmann3560 Месяц назад
After every storm I run around town fixing panels laying on the ground cause of stripped screws lol
Далее
THIS TRANE SPACESHIP JUST STOPPED WORKING
25:51
Просмотров 62 тыс.
AC Capacitor hacker strikes again
13:37
Просмотров 109 тыс.
Прохожу маску ЭМОЦИИ🙀 #юмор
00:59
5 Reasons Your Thermostat is BLANK!
6:03
Просмотров 140 тыс.
SOMEONE MESSED UP BIG TIME
28:20
Просмотров 106 тыс.
Personal "air conditioners" aren't what they seem
27:03
THEY SAID PLEASE HURRY THE AC'S ARE NOT WORKING
45:53
Просмотров 299 тыс.
Class - What Superheat Signifies
17:07
Просмотров 240 тыс.
MULTIPLEX SYSTEM IS COMPLETELY DOWN
28:21
Просмотров 63 тыс.
The ONE AC Upgrade Every Homeowner Needs to Consider!
18:32