Тёмный

This Could’ve Been BAD!! 

Quality HVACR
Подписаться 103 тыс.
Просмотров 17 тыс.
50% 1

- SUPPORT THE CHANNEL -
www.patreon.com/qualityhvacr?...
- Check out @TruTech Tools, LTD -
www.trutechtools.com (Use promo code “QUALITYHVAC” to save 8%)
- HVAC TACTICAL -
hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%)
- FOLLOW ME -
Instagram: @qualityhvacr
- BUSINESS INQUIRES -
qualityhvacrtn@gmail.com
- TOOLS I USE -
Solderweld Brazing Kit:
trutechtools.com/HVAC-15-All-...
Fieldpiece DR82 Leak Detector:
trutechtools.com/fieldpiece-d...
hilmor lineset cleaning kit:
trutechtools.com/hilmor-hlc00...
RLS Refrigerant Press Tool Kit:
www.trutechtools.com/klauke-1...
Veto Pro Pac MB5B Tool Bag:
trutechtools.com/veto-pro-pac...
Supco Jumper King:
trutechtools.com/supco-tfxjk-...
Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtools.com/JL3KH6?a...
Fieldpiece VP87 Vacuum Pump:
trutechtools.com/fieldpiece-v...
Fieldpiece MR45 Recovery Machine:
trutechtools.com/Fieldpiece-M...
Fieldpiece Hose Kit:
trutechtools.com/fieldpiece-h...
Fieldpiece SR47 Refrigerant Scale:
www.trutechtools.com/fieldpie...
Fieldpiece SC480 Meter: www.trutechtools.com/Fieldpie...
Fieldpiece SC680 Meter: www.trutechtools.com/Fieldpie...
Fieldpiece SM380V Digital Manifold: www.trutechtools.com/Fieldpie...
Supco Magnetic Umbrella: www.trutechtools.com/Supco-Ma...
Supco Coolpressor:
trutechtools.com/Supco-CoolPr...
Supco Jumper King:
trutechtools.com/supco-tfxjk-...
#qualityhvacr #hvac #refrigerant

Кино

Опубликовано:

 

10 апр 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 74   
@reflex4948
@reflex4948 3 месяца назад
I can’t wait to start my hvac career, I’m gonna graduate high school in a month and go to trade school
@malcolmwhite821
@malcolmwhite821 3 месяца назад
Depending on where you live. Trade school can cost some big bucks. Going through the Union here you do schooling at night for no cost and 5 years. Then you are a Journeyman. Something to consider.
@Jfriesheatingandcooling
@Jfriesheatingandcooling 3 месяца назад
In Michigan, all you need is 3 yrs experience to take the state test. 2 years with a degree.
@ronaldswindell1525
@ronaldswindell1525 3 месяца назад
Oh to be young and full of vinegar again
@braydendillenbeck1833
@braydendillenbeck1833 3 месяца назад
@@Jfriesheatingandcooling3 years to take your epa?
@Jfriesheatingandcooling
@Jfriesheatingandcooling 3 месяца назад
@@braydendillenbeck1833 epa can be taken whenever you feel you can pass it as long as your boss allows it. 3 years experience before you can take the state exam to hold a mechanical license.
@al6347
@al6347 2 месяца назад
De minimis I haven't heard that word in a very long time. You are absolutely right it would be De minimis to vent the recovery line from tank to the recovery machine. Good video.
@VictorSavelle
@VictorSavelle 2 месяца назад
Keep up the great work, man. I know how difficult and time consuming it is to set up cameras as you work, you have a good eye for scenes as well. Not even mentioning how valuable it is to see field experience on video like this. Big time kudos 👍👍👍
@UnbornHeart2020
@UnbornHeart2020 3 месяца назад
ok I admit it, Im addicted to your vids, line of work, I guess in order to get more content Ill just have to start working for you since I live in Lebanon lol
@OcRefrig
@OcRefrig 3 месяца назад
Good video ! That's Why u ALWAYS Hook up Your Guages to Both The High & Low side of a System During Recovery & Evacuation. Makes For Less Suprises , Faster Recoveries & Evacuations. 2 Hoses ARE faster than 1. 3 Hoses are Faster than 2. Hense Why in cars they use 2 Valves per cylinder. They found that 2 smaller Valves Can Flow MORE Than 1 Big valve. Basic Rule of thumb for Refrigeration system capacity is 2-3 lbs of Refrigerant / Ton. 20 ton system = 40-60 Lbs of Refrigerant. Use This as a Guide line to Figure out How many Refrigerant or Recovery Jugs You Need.
@zekenzy6486
@zekenzy6486 3 месяца назад
Great Video. Thank you for sharing
@hvacrnortheastern2110
@hvacrnortheastern2110 3 месяца назад
Great video late 90s l sprain my ankle by getting my foot caught between the cab and truck bumper while we change out the cap top l don’t work for the contractor due other matters Few years later same foot l fracture my foot l was going up a steel ladder l the third step l fell due to oil on rungs few weeks back they were changing compression on the racks .My wife when nuts due to we supposed to go on vacation on a cruise in about 6 months will l went no matter what it took.. Still to day l still sometimes getting out bed l have weak ankle feeling it been over 24 years.
@miniman9198
@miniman9198 3 месяца назад
I got a middle school I do work at that has this exact condensing unit for their auditorium 😂 soon as I saw it I was like "aye I bet that guy has a big tan K-style compressor in it"
@markprime1008
@markprime1008 2 месяца назад
I'm going to uei college for Hvac 10 month program I'm on my 7 almost done and close to graduation your videos will help me learn more thank you so much
@j.r.branch1681
@j.r.branch1681 3 месяца назад
Man I done that and tore the tendons in my ankle and my knee we had to have 3 surgeries and out of work for 2 years on worker comp so be careful it easy to get hurt by accident I’ve been a service tech for 25 years that’s the worst I’ve ever got hurt working on a unit
@richardgeiger1669
@richardgeiger1669 3 месяца назад
Great content. I have a question as to what is the leather case you have on your side of you hip? Please share
@thesilentonevictor
@thesilentonevictor 3 месяца назад
Good job Zack
@dansmith3256
@dansmith3256 3 месяца назад
Do you know where I can find the square to round 14 inch duct attachment for the Ameristar package unit?
@gregdemars2751
@gregdemars2751 3 месяца назад
Nice job 😊
@HvacGregG
@HvacGregG 3 месяца назад
Cool can’t wait to see that video
@luisamaro7397
@luisamaro7397 3 месяца назад
Here in phx I return my refrigerants to my scrap yard they buy r22 for $8 lbs and 410a at $1
@OcRefrig
@OcRefrig 3 месяца назад
are u saying like metal recycling ♻️ scrap yard ?
@ayoutubewatcher7009
@ayoutubewatcher7009 3 месяца назад
I bet you were thrilled to find the condenser on the ground
@07JR
@07JR 3 месяца назад
Good job bro
@topher8634
@topher8634 3 месяца назад
If you want a faster recovery, try the push-pull method. It's great as far as liquid recovery goes, but once it's gone you should switch to regular vapor recovery. As far as the pressure left in the hoses- does that machine have a purge feature? I use a Yellow Jacket machine and after I switch over to purge and let the machine turn off, there is a minuscule amount in the hoses.
@ayoutubewatcher7009
@ayoutubewatcher7009 3 месяца назад
I’ve pumped anywhere from 50-200 lbs of liquid refrigerant into a circuit with that machine, in a matter of 1-2 hours, as long as it’s throttled correctly.
@topher8634
@topher8634 3 месяца назад
@@ayoutubewatcher7009 with the yellow jacket or the fieldpiece? I've used the yellow jacket to recover and recharge the chillers where I work a few times. One holds 490# of R-134a the other 400# of R-22. I don't even throttle it, the machine belongs to the facility and I've been trying to kill it so I have a legitimate reason to submit a requisition for a new Fieldpiece, but it seems to eat any amount of liquid I feed it.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 месяца назад
Push pull works. I use it on larger systems. This is only 20 tons....so a conventional recovery isn't out of the question. I have those seedy wyes from appion and they do help. I use ¾" hoses that step down to ⅜" and ¼" I can get a lot of refrigerant really quick through them conventional or push/pull. We have brazed plate HXers for our subcooler. We recently recovered a York YK with 1500lbs and it took 1 hour for the liquid and the most of the rest of the day for vapor. Larger hoses are the key.
@hectorgarcia-zv1wi
@hectorgarcia-zv1wi 2 месяца назад
A few videos ago you were talking about different type of hvac skills like on call can u pls elaborate more about the difference between all and what they can consist of??
@marketmash6953
@marketmash6953 3 месяца назад
Would it make a difference to start on the liquid side, since you want to pull liquid anyways? Then open up the vapor side when liquid is low?
@mariacortes6797
@mariacortes6797 3 месяца назад
Buen trabajo amigo, Dios te bendiga.
@Learn_SKY
@Learn_SKY 3 месяца назад
Thank you for sharing the informative video! I have a question. May I know the information of the refrigerant recovery device you use? In the video, an alarm went off at the refrigerant recovery device. Does the refrigerant recovery device you use stop working while generating an alarm when the appropriate pressure is achieved in the refrigerant recovery container? I like your video very much. I am sure you will continue to share informative information in the future. I would like to express my gratitude to you in advance:D😊
@prowesstv
@prowesstv 3 месяца назад
What headset is that ? I can't stand the in ear buds. This, however, looks interesting enough to try.
@mauriciomendieta1889
@mauriciomendieta1889 Месяц назад
Are you going to release Part 2?
@arish00
@arish00 Месяц назад
Hey I'm curious about your work boots in this video, what brand are they and where did you purchase them? And what's your thoughts on them? I assume they are great for what you do out in the HVACR field.
@hvacguy11
@hvacguy11 3 месяца назад
Big money job nice!
@azizmahama5174
@azizmahama5174 3 месяца назад
I love your job Zack, let’s do some work 💯
@ryanmatthew275
@ryanmatthew275 3 месяца назад
What kind of boots you rockin? You like them? My timbs at starting to fall apart
@williamcahill617
@williamcahill617 3 месяца назад
You need to invest in a solenoid magnet donut for liguid line
@1116JOE
@1116JOE 3 месяца назад
You probably should put a lock on the inside disconnect to make sure no one turns it on by mistake
@1116JOE
@1116JOE 3 месяца назад
Never mind you text just popped up saying you did it.
@aarongray503
@aarongray503 3 месяца назад
What headset are you using?
@zahedaminullah6934
@zahedaminullah6934 3 месяца назад
Good work Zack, if you sprained your ankle, I would use a dolly to transport all the stuff honestly, not worth the body. Good lockout tag out, safety first.
@dailydose5847
@dailydose5847 3 месяца назад
Sir how I work with you as your assistant in Hvac field. Love from Qatar 🇶🇦
@daniloiraheta0529
@daniloiraheta0529 3 месяца назад
What the use life on those deier ..?
@jhatfield2755
@jhatfield2755 3 месяца назад
Y not just put a magnet on solenoid
@mikev.1034
@mikev.1034 3 месяца назад
👍👍
@twincam825
@twincam825 3 месяца назад
lock out.
@jfrancis98
@jfrancis98 3 месяца назад
Now put a lock and tag on that disconnect that you turned off. Please.
@findme5270
@findme5270 3 месяца назад
Would’ve just dumped 87 psi and not even messed with recovery
@JesseDoesHVAC
@JesseDoesHVAC 3 месяца назад
Do the right thing. Decant the refrigerant properly
@ValorHeart
@ValorHeart 3 месяца назад
Why is your shirt opened at the back?
@themrmoy40
@themrmoy40 3 месяца назад
air
@cameronblades2394
@cameronblades2394 3 месяца назад
Somebody link that Billy Madison clip about being dumber after this explanation. FFS
Далее
Я ПОКУПАЮ НОВУЮ ТАЧКУ - МЕЧТУ!
39:05
Horrible HVAC Design & How I FIXED it!!
21:10
Просмотров 37 тыс.
Traveled 7 HOURS for a Service Call...
13:41
Просмотров 13 тыс.
This Was a TERRIBLE Install….Until Now
16:29
Просмотров 32 тыс.
How Many Calls In ONE Day Is Too Much?? | HVAC Life
14:32
DON’T Assume Anything…HVAC Repairs
15:55
Просмотров 34 тыс.
Why Would They Do That?!?! HVAC Repairs…
20:13
Просмотров 51 тыс.
тгк: ПРОСТО МОСТАК
0:11
Просмотров 1,2 млн
Must watch new special comedy wait for end 😆🤣
0:49