The short video is some tips from paralleling inverters, it might seem obvious but I can assure you not everybody follows the simple tips

Опубликовано:

 

12 фев 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 17   
@Tranquilitarian
@Tranquilitarian 2 года назад
In the manual it says each inverter (in parallel) should have its own CB for grid and load ports respectively. However, Keith is saying in this video that two (or more) inverters should share one CB for load and one CB for grid. I’m I misunderstanding something?
@MrTrojantrdll
@MrTrojantrdll 2 года назад
Thanx for the information 👍 😀
@bestota
@bestota 2 года назад
How is the difference between single phase and 3 phase? In essence can I use a 3-phase inverter with my single phase meter (grid supply) for a hybrid solar solution? Does a larger inverter have more benefits than a parallel system? Any helpful information on going about this is welcome (counting the cost before embarking on hybrid solution).
@don-ashbybaloyi9436
@don-ashbybaloyi9436 Месяц назад
Good day. I recently bought a second hand RCT inverter (4000W 48V) and connected it. It has been working well, but it was a slave unit from wherever it was connected. How do i reset it to main unit? It started beeping showing a warning 'HS' on the screen and it does it now and then lately. Please help
@SolarIntegrations
@SolarIntegrations 9 месяцев назад
Hi Keith, two questions, Dd the inverters have to be balanced i.e. Do you have to have the same numbers of inverters on each phase or can you have 2 inverters on one phase and 1 inverter on each of the other phases? Also, do all the inverters have to be the same size i.e. 5,8 or 16kw or can you mix them at all?
@kevinpickett7249
@kevinpickett7249 8 месяцев назад
Question on a 3.6KW inverter G98 what circuit breaker do we fit as I thought it had to be 16Amp to comply but I see if we connect say water heater and a washing machine to the load size I see pass through current is 32amp 🤔 I assume that's via battery so it still can be a 16 amp as it cannot draw or send back more than 16 amps to grid?
@Maled1cted
@Maled1cted Год назад
Hello. As I understand inverter 1 should connect to l1, inverter 2 to l2, inverter 3 to l3. They all share one battery pack. Inverters should not use their own batteries in separate . What will happen if for some reason with power outage L1 will be disconnected, or L2 with L3? And what will happen when phase/phases will be connected back again to an underpowered inverter/inverters? What will happen if for some reason L1 will be swapped with L3, or L3 with L2 etc on the input of the inverters? I’am looking into building a setup when three inverters will be connected to three phase power network and my home equipment will be connected to one phase that will be shared between three inverters.
@gazzstewart
@gazzstewart Год назад
What appears to be a common problem is that input phase rotation is correct put it switches on output despite correct modbus and phase assignment settings. Helpdesk advice is to change settings on L2 and L3, making L2 in phase C out and L3 in, phase B out. Surely this is not the right way to go about things? The phase sequence should be maintained from input to output without the need to "fool" the inverters
@awesomedee5421
@awesomedee5421 Год назад
Why do the cables from the busbar to the inverter need to be the same lengths? Each leg is going to pull the amount of power based on what is being used so it should be the shortest. The statement "you are going to have problems" is very vague. Can you elaborate? I can agree that the battery to bus bar should be equal lengths, but assert that busbar to inverter should be shortest length.
@pieterkruger4134
@pieterkruger4134 Год назад
Paralleling 2 x 12kw Sunsynk with FreedomWon battery. I'm getting error F41 Parallel System Stop. I don't see it in the training manual. what is the problem here?
@theunssnyman6310
@theunssnyman6310 6 месяцев назад
Same issue on couple of sites....try an update on the firmaware
@alinscripcaru5167
@alinscripcaru5167 7 месяцев назад
hello, please help me with a Deye 12kw three-phase inverter where I have the error: f31 ac slave contactor fault, the inverter has been newly installed in on-grid mode for 5 days and I can't get rid of that error, I also asked for an upgrade of firmware but I didn't get a reply, I'm from Romania but it seems I can't find Deye support in my country
@makesolareasy
@makesolareasy 2 года назад
Hi, not related to your video. But I have a client that has a delay of about 10mins from real time to registering changes on the Solarman app. Where can we start looking for the problem?
@marcocabula7178
@marcocabula7178 2 года назад
There is normally about a 5 minute delay. Could be internet.
@cods41
@cods41 2 года назад
Can I have one hybrid system with 3 5kw hybrid inverters. But only two of them connected to the battery, and the third one acting as a solar inverter only? Will I still be able to limit my total export power across all 3 inverters?
@bassplaya69er
@bassplaya69er 11 месяцев назад
bus bar not buz bar
@jameshuynh5436
@jameshuynh5436 Год назад
Talk to much. No diagrams lay out
Далее
Sunsynk Magic Part 1
5:39
Просмотров 2,4 тыс.
Basic Sunsynk Training course 25 March 21
1:00:17
Просмотров 55 тыс.
Зачем он туда залез?
00:25
Просмотров 63 тыс.
Brief introduction to Battery systems
23:34
Просмотров 32 тыс.
Sunsynk Wiring multi inverters
9:59
Просмотров 18 тыс.
Paralleling Sunsynk, 50 kW inverter
6:35
Просмотров 26 тыс.
Sunsynk Training part 2 sec 2
17:55
Просмотров 15 тыс.
Deye Hybrid Inverter Max  16pcs in Parallel
5:23
Просмотров 6 тыс.
What can run on an inverter and for how long?
10:46
Просмотров 264 тыс.
Advice when installing a Sunsynk Hybrid Inverter
8:05
How to parallel single phase with SNA 5k
14:03
Просмотров 16 тыс.