TRANE RTAA WITH OIL SYSTEM FAULT/ AHU WITH SMOKE DETECTOR TRIPPING  

Jason Johnson
Подписаться 919
Просмотров 9 тыс.
50% 1

Sorry my flub. i called the oil cooler line the oil return.....can't be perfect all the time. 😆 🤣 😂

Опубликовано:

 

15 июн 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 44   
@EverythingHVACR
@EverythingHVACR Год назад
Nice job, Jason! Great content. Leave the Trade better than we found it 💪
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Yes sir.....you and Holden are the biggest reason i started to film calls. I have tons of respect for both yall
@fshn76
@fshn76 Год назад
When you ask the customer they say no we didn’t touch it. 😅😅😅 thanks for the video Jason.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
😁 lol
@Practicing_HVACR
@Practicing_HVACR Год назад
I was surprised to see someone working on heavy commercial equipment on RU-vid. The only person I knew about was Holden. Funny to see that he’s your supervisor. I’ll be following for some more good content.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Check out Everything HVACR as well....Steve is a smart guy, cool as hell and has great videos
@Stevehevessy
@Stevehevessy Год назад
Great video,looking forward To watching more
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Thank you
@TheChillerGuys
@TheChillerGuys 5 месяцев назад
good stuff man
@dfirth224
@dfirth224 Год назад
I've switched to Wago wire connectors. Much more reliable and can be visually inspected.
@teeba2001
@teeba2001 Год назад
Hello It’s my first time watching your video. Really what I liked is your advice to follow an expert to share the information and experience then you introduce the same information to others… I think this is the joyful part of technician carrier. Good luck
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
I appreciate your comment.
@wata_laf
@wata_laf Месяц назад
Great find man
@jasonjohnsonHVAC
@jasonjohnsonHVAC Месяц назад
@@wata_laf appreciate you
@knowledgeunderstanding4192
@knowledgeunderstanding4192 3 месяца назад
Love it! Continue on your journey
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 месяца назад
💯
@SoutheastHVAC
@SoutheastHVAC Год назад
Awesome video. I’m still getting the hang of working on these chillers
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Im right there with you. I have some experience.....but not enough to call myself a true chiller tech. I love learning, so its given me plenty to study
@petersmart1999
@petersmart1999 Год назад
Hello Jason,I remember a time that I was on a call in the middle of the night,for a CHANDLER/Kinda like a McQuay unit! Well they kept saying it was tripping on oil sentry,they reset it a bunch of times but no fix! Enter me at 2 AM,so I get there and first thing is an oil fault and it also lost a fan,so in changing the motor I needed to lean into the unit,so i got up on my stool and leaned on and got a huge suprise,the crankcase heater was laying in the bottom of the unit,burnt the shit out of my hand,needless to say it to me 3.5 hrs to do a 30 minute job! But hey no more oil faults! P.S I never told the idiot what was wrong,or that putting the heater back in the compressor was tenfold!thx for the great videos
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Lol....how are you my friend...hope all is well...thanks for sharing a war story
@petersmart1999
@petersmart1999 Год назад
@@jasonjohnsonHVAC I had a blister 3/8" wide the whole length of my hand! I waz so mad
@jeremydragon1077
@jeremydragon1077 Год назад
Worked on a RTAA today with the same oil fault. I work at APS Dallas. We could use a Holden up here! Thanks for the oil tips. I’m going to check the DP across the filter and oil level.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
One of our guys left here and went there. His name is Brady....he's a cool guy
@brianmcnabb3184
@brianmcnabb3184 11 месяцев назад
Bannockburn remember when that chiller was installed.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 9 месяцев назад
Yes sir
@TheGhettoLobster
@TheGhettoLobster Год назад
Didn't realize you work with Holden. Thats cool
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Yes sir. Its been awesome to learn from him and to have access when im stuck.
@manijani5539
@manijani5539 Год назад
Great info. Thanks
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Glad it was helpful!
@garypoplin4599
@garypoplin4599 Год назад
6:23 - The smoke detector was tripping out on your Marlboro (or is tha a Camel filter?)
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
😂😂😂😂
@dirkdigler9336
@dirkdigler9336 4 месяца назад
I believe oil system fault is thrown when oil temperature is 4* or more below condenser saturation temperature.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 4 месяца назад
You are correct, it also has to do it within a certain time frame
@Eighty8Fitter
@Eighty8Fitter 3 месяца назад
Floodback is 95% the issue with oil problems. Dont matter if it’s a recip or a rotary screw, floodback will wash the oil from the bearings and trip your oil fail or cause further issues with your system like you’re seeing now.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 месяца назад
Agree completely. Thanks for the comment
@kenfewell4200
@kenfewell4200 3 месяца назад
unit could use a good cleaning
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 месяца назад
Yep, she was a tad dirty
@mr.invisible3770
@mr.invisible3770 Месяц назад
Just fyi, there is no T in the word across
@Kevin-wj4ed
@Kevin-wj4ed Год назад
Time to replace unit.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Its planned to. I believe the only thing we are waiting on is for the new chiller to be built. Unfortunately, that's a long process and a long waiting list. I believe it's a 1 year wait time on new equipment like this to be ready for installation.
@Kevin-wj4ed
@Kevin-wj4ed Год назад
@@jasonjohnsonHVAC I work for school we ordered a new 70 ton chiller Dec 22 not getting it till Oct 23.
@petersmart1999
@petersmart1999 Год назад
What kind of Fire system is that
@jasonjohnsonHVAC
@jasonjohnsonHVAC Год назад
Not sure to be honest
@petersmart1999
@petersmart1999 Год назад
We been changing alot of them,the MXL Pyrotronics systems are obsolete,so whe cant get parts at all! Its kinda funny,they are 20 years old and obsolete,yet we have System 3's that are 40 years old and never been worked on!
Далее
Low Oil Troubleshoot RTAA Chiller
11:24
Просмотров 15 тыс.
Чёрная ДЫРА 🕳️ | WICSUR #shorts
00:49
Просмотров 836 тыс.
What I do for a living, building engineer!
25:16
Просмотров 6 тыс.
How Air and Water Cooled Chillers Work
13:14
Просмотров 85 тыс.
Trane AC 18 S.E.E.R. untouched for 20 years
17:52
Просмотров 367 тыс.
Trane RTAC Leak Repair + Oil Filter Part 1
19:57
Просмотров 12 тыс.
How a oil flooded rotary screw air compressor works
8:45
Let's Talk Oxy Acetylene
18:52
Просмотров 1,8 млн