Two button VINTAGE LIFT - the old motor room! 

mrmattandmrchay
Подписаться 46 тыс.
Просмотров 34 тыс.
50% 1

THE MRMATTANDMRCHAY CHANNEL, established 2009:
I'm passionate about uploading quality and interesting videos for YOU, my audience.
What is my channel about? "Old lift machinery made interesting", old air-raid sirens, prehistoric alarm equipment - things that "I" find fascinating and I hope you will to, as I always spend a lot of time editing my videos with animations, in sync with music and voice overs to make them this way.
My moto - "Quality NOT Quantity" - spending a month editing a video is not a rarity!
But without you, I'm nothing here. Thank you so much for watching.
Thanks to Mikie Furniss for setting this visit up.
Visit MIKIE'S RU-vid CHANNEL here:
/ @tiegtheimmortalelites...
See PART 1 of this VINTAGE LIFT here:
• VINTAGE LIFT with only...
SLIP RING MOTOR VIDEO:
• SLIP RING MOTOR - how ...
The LIFT SAFETY BRAKE VIDEO is here:
• The ELEVATOR SAFETY BR...
ELEVATOR BOB'S WEBSITE (vintage and new elevator photos from many contributors):
www.elevatorbobs-elevator-pics...
My 'ONLY THE BEST' playlist - hand picked by me and updated regularly:
• MY BEST VIDEOS (only t...
For information about LISTED BUILDINGS here:
en.wikipedia.org/wiki/Listed_...

Опубликовано:

 

17 фев 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 82   
@seanjuth
@seanjuth 4 года назад
It looks like the building actually caught on fire once. You can see the black marks on the walls of the outside of the machine room
@mrmattandmrchay
@mrmattandmrchay 4 года назад
As again, thanks for everyone who watched the video when it Premiered. Always great to chat to you, my viewers. Next video is tomorrow!
@sirenealertedu1ermercredid256
@sirenealertedu1ermercredid256 4 года назад
this Thursday there February 20 there is the siren test in castairs film the siren test the siren C horn CS8 CARNWATH ?
@mrmattandmrchay
@mrmattandmrchay 4 года назад
@@sirenealertedu1ermercredid256 I'm 400 miles away from there, so I won't be filming anything. I only go there when I'm away on business, which is once or twice per year.
@qeelevators2960
@qeelevators2960 4 года назад
You forgot to tell us that the time wasn’t right. Then I was late by 80 mins.
@tizutitandula5638
@tizutitandula5638 4 года назад
Hello, to everyone: keep out of lift machine rooms. Me, experienced person was already in over 30 lift machine rooms and Shafts, and again KEEP OUT. Just by doing something wrong you can die in a few seconds. Sorry for spamming, but my last words are KEEP OUT!!! Sorry for bad English.
@qeelevators2960
@qeelevators2960 4 года назад
Tizu und Titandula - I’ve been in almost 30 as well and I’m 10. I understand how dangerous the moving parts are and know not to get too close.
@davidk8893
@davidk8893 Год назад
It used to be common for the cells in batteries to be made of glass. In order to avoid breaking them, they were often housed in wooden boxes such as that one. The cells often resembled jars, which would explain the round outlines inside the box. On a similar note, the glass battery cells is also the origin of the myth that you shouldn't set car batteries on the ground. When batteries were made of wood and glass, setting them on damp concrete or dirt could cause the wooden case to swell, putting pressure on the glass cells and breaking them. It became standard practice to store the batteries on wooden shelves, or on top of a wood plank to isolate them from the concrete. Once batteries started being manufactured out of more modern materials the practice wasn't necessary anymore, but it is still a common misconception that you shouldn't set batteries straight on the ground.
@dykodesigns
@dykodesigns 4 года назад
Interresting motor room, that wooden box. Two wirings sticking out of it. One thing I noticed straight aways is the asbestos ceiling boards. Structurally the floor of the motor room is really old fashioned, the motor is directly supported by a few steel beams and the concrete is just infill, probably not reinforced because of the short span between the rusty beams.
@38911bytefree
@38911bytefree 4 года назад
AMAZING VID.through all this years controller probably needed to be upgraded because of lack of psarts or meet new regulations. But most of it is still the original, glad to hear it is listed.
@ebnicolaou
@ebnicolaou 4 года назад
38911bytefree this lift cant be modified according to regulations
@sp00kd37
@sp00kd37 4 года назад
Always nice seeing new videos by you, keep on putting out quality content
@mdebough
@mdebough 4 года назад
Great video :)
@misterwint
@misterwint 4 года назад
Great video. I guess if you're going to see a modernised lift control cabinet then it's good that the modern one is still a vintage.
@Goasler
@Goasler 4 года назад
3:36 min O.o OMG this nice old Machine. Thank you that you show us this things!
@mrmattandmrchay
@mrmattandmrchay 4 года назад
It's a real classic and glad we got to film it!
@ag6371
@ag6371 2 года назад
It's like 100+ years old
@glen7463
@glen7463 4 года назад
Great video
@sentry1234
@sentry1234 4 года назад
Epic vid
@djadventure
@djadventure Год назад
Nice asbestos on the ceiling. Good Video
@paulstubbs7678
@paulstubbs7678 Год назад
Nice old lift, that controller cabinet is so modern compared to the rest it's not funny. pity when the old controller was replaced, that they didn't just leave the old one there and add the new one. That wooden battery box probably contained No 6 cells - aka telephone batteries. Wooden box's were regarded as the best place for these (and lead acid cells) as they are not overly bothered by leaks & keep the cells at a relatively stable temperature. Placing cells on concrete etc was seen as bad as cold concrete mucked up the chemistry, best to have the whole cell at the same temp, hence wooden box, or at least a wooden shelf (old school thinking) No 6 cells have an incredibly long shelf life, especially in this use as they normally would do nothing, just waiting for someone to press the button, so if there was a maintenance schedule, entirely reliable. My main observation was the motor brake didn't seem to be operating, I was expecting loud clunks from it etc.
@oreoofficial97
@oreoofficial97 4 года назад
Y Got here at the right time
@salifrtsalifrt3817
@salifrtsalifrt3817 4 года назад
Seeing old stuff is just so emotional.......
@mrmattandmrchay
@mrmattandmrchay 4 года назад
haha, cool, you've found the right channel for nostalgic lifts! :)
@salifrtsalifrt3817
@salifrtsalifrt3817 4 года назад
@@mrmattandmrchay Yes, surely! the lifts or the schlinder (1990) some model actually is so memorable to me! wow
@Steve_Wardley_G6JEF
@Steve_Wardley_G6JEF Год назад
Great to watch, if only through clenched fingers. Thanks to my phobia of lifts, particularly old ones, there is no way I would have even stepped into an old lift like that. I can't be doing with seeing any of the shaft structure in old gated lifts. Irrational I know but there nevertheless.
@videomentaryproductionschannel
Those Battery's in that alarm backup, would have been probably Accumulators, glass jars full of acid with electrodes, They used the same thing on master clocks in hospitals, in early days, that's my bet, great video by the way, as always 😊
@electo99
@electo99 4 года назад
looks like a modern control panel nice elison over load and isolator on the wall the wooden box is for the alarm bell batteries normally flag cell batteries (we still have them at work) possibly had lead acid accumulators in it when new
@RediffusionMusic
@RediffusionMusic 4 года назад
Did think this one would be a bit early for a Trislot motor :)
@JRS-UK
@JRS-UK Год назад
I’m 2 years late to this, but an observation/guess I’ve made is it could be possible the upgraded cabinet is when the documents where put there, which would mean it was installed in 1977.
@keith800
@keith800 9 месяцев назад
Most interesting , but if it is a Hammond and Champness controller why is there a diagram from Shorts lifts ? ( part of Marryat and Scott at one time ), there would be a timer to allow you time to enter the lift car and select your floor without it being called away before you had a chance to pull the landing gate open.
@JFinnerud
@JFinnerud 4 года назад
So if i understand your diagram correctly, the resistor bank is a kind of ancient soft start so to speak ? Thanks for an awesome video!
@qeelevators2960
@qeelevators2960 4 года назад
Elevator bob needs a redesign for his website!
@Lift.Tracker
@Lift.Tracker 4 года назад
Great video! Enjoyed the premiere! :-)
@sentry1234
@sentry1234 4 года назад
Lift Tracker same here
@ag6371
@ag6371 2 года назад
Some even had cranks instead of deadman buttons
@speedgelbproductions5089
@speedgelbproductions5089 3 года назад
Feels like it's switching from star to delta too quickly (almost instantly). Issue with the configuration of one of the timers? Would be easier to level if the star-delta switchover period was longer :-)
@jarrodemery4631
@jarrodemery4631 11 месяцев назад
Appears to be an Otis (Waygood Otis) #1 machine. Probably had a 1SOB controller. Still a few around.
@b43xoit
@b43xoit 9 месяцев назад
Two-button, hyphenate.
@millsyinnz
@millsyinnz 4 года назад
This is why I prefer to take the stairs.
@hughsgarbagetrucks
@hughsgarbagetrucks 9 месяцев назад
9:19 I would of asked if I could have those contacters
@TheTheo58
@TheTheo58 4 года назад
So this type of motor slip ring used up and down contactors within in the controller cabin with the starting relays for each phase? Since this elevator is fully manually operated, up and hence the need for a phase reserving relay? I doubt a steel controller cabinet would have been installed way back in 1095.
@Lift.Tracker
@Lift.Tracker 4 года назад
TheTheo58 I agree! “1095” would probably be a bit early for a steel cabinet. LOL :-)
@ag6371
@ag6371 2 года назад
*1905
@brendakoldyk1647
@brendakoldyk1647 3 года назад
The bell box batteries were dry cell batteries rated at 1.5 volts.
@qeelevators2960
@qeelevators2960 4 года назад
You said at 8:00 PM so I am *VERY* late.
@smartz8334
@smartz8334 4 года назад
You know now if you think about it you can make a elevator with 5 things .a building with a elevator shaft .a Arduino .a good motor .and a small wooden (or metal) room .And some THICC ROPE
@fluffyshabba6423
@fluffyshabba6423 4 года назад
Why do I feel like I've seen this exact same lift before?
@oreoofficial97
@oreoofficial97 4 года назад
Hello
@fab555trainspottingandmore
@fab555trainspottingandmore 2 года назад
What happens if this Elevator breaks down?
@djadventure
@djadventure Год назад
Then it wont move
@tonybaines3332
@tonybaines3332 4 года назад
loads of lift companies have had it over the years, all added bits to it.
@tonybaines3332
@tonybaines3332 4 года назад
it also has the wiff of hammond and champness
@tonybaines3332
@tonybaines3332 4 года назад
that controller looks like a modified hydraulic controller. simples.
@tonybaines3332
@tonybaines3332 4 года назад
it is a h and c controller.
@tonybaines3332
@tonybaines3332 4 года назад
the button will have 2 sets of contacts on it, a copper strip and a spring thats all, 1 normally made and 1 normally closed, so you cant push both in at the same time, bakalite everywhere.
@tonybaines3332
@tonybaines3332 4 года назад
sorry 1 n/o and 1 n/c
@tonybaines3332
@tonybaines3332 4 года назад
a five way trailing cable with up dn common and 2 for the car gate switch. simples.
@mrjelelia1409
@mrjelelia1409 4 года назад
Yee
@justintrines4522
@justintrines4522 Год назад
Are they old 1905 elevators operational?
@djadventure
@djadventure Год назад
Nope it was shut of in 1989
@Brendan_Keyport-WA7BMK
@Brendan_Keyport-WA7BMK 4 года назад
What's the "yard" level?
@LBSiUK
@LBSiUK 4 года назад
I thought it had a timer relay so it would allow the lift to slow down a little bit before the brake slams on therefore preventing wear on the brakes.
@AS_Archives
@AS_Archives 4 года назад
I MISSED THE PREMIERE!:/
@qeelevators2960
@qeelevators2960 4 года назад
Sae
@syaz4380
@syaz4380 4 года назад
My country is filled with Schindler and Otis lifts. You can't find a new model like the 3300 or 5500. I found a 5500 at a shopping mall. Bruh also my country us filled with Schindler D-Series
@tonybaines3332
@tonybaines3332 4 года назад
the button is etchells condem and muir
@tonybaines3332
@tonybaines3332 4 года назад
Etchells, Congdon and Muir.......
@tonybaines3332
@tonybaines3332 4 года назад
ECM
@tonybaines3332
@tonybaines3332 4 года назад
www.gracesguide.co.uk/Etchells,_Congdon_and_Muir
@julienboller2165
@julienboller2165 4 года назад
this Thursday there February 20 there is the siren test in castairs film the siren test the siren C horn CS8 CARNWATH ?
@stephenhunter70
@stephenhunter70 3 года назад
Without batteries the emergency alarm call buttons would be useless. So how would anyone who was trapped in the lift get help.
@djadventure
@djadventure Год назад
Phone
@tonybaines3332
@tonybaines3332 4 года назад
the 2 other contactors are to protect the buffer resistors,
@tonybaines3332
@tonybaines3332 4 года назад
anti quick reverse.
@tonybaines3332
@tonybaines3332 4 года назад
the 2 timers underneath will be set to 3 seconds.
@mrmattandmrchay
@mrmattandmrchay 4 года назад
@@tonybaines3332 Always great to hear your comments Tony
@ag6371
@ag6371 2 года назад
Can't believe this is 100 years old
@skorpion8051
@skorpion8051 4 года назад
Great video
Далее
Yeni Özbək Mahnisi Yoxsa Vefali Reqsi? 😍
00:36
Просмотров 1,2 млн
Exploring an Otis door controller
21:21
Просмотров 80 тыс.
10 Second Kettle
5:04