Understand all about Oil Trap in HVAC Refrigerant Pipe 

HVAC-R -BE PROFESSIONAL
Подписаться 8 тыс.
Просмотров 57 тыс.
50% 1

Hi Friends! This video we going to understand all about Oil trap in HVAC refrigerant Pipe?
What is the Purpose of Oil Trap In refrigerant pipeline?
Why Oil Trap is Important in HVAC Refrigerant pipe?
How the Oil Trap Works?
How to size the Oil Trap?
Suction line oil traps.
Discharge line oil traps.

Опубликовано:

 

6 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 28   
@jamminwrenches860
@jamminwrenches860 3 года назад
I just did an electrical repair on a reach in cooler and there was one of these every 20 ft or so on the suction line. Now I understand why. Thank you for helping educate us.
@AhmedAhmed-lz1ke
@AhmedAhmed-lz1ke 2 месяца назад
Aoa.Very knowledgeable Explanation. Thanks
@JDT738126
@JDT738126 9 месяцев назад
Perfect video on oil traps!
@baskorobas7550
@baskorobas7550 2 года назад
Terimakasih.....ditunggu vidio yg lainnya
@noufalkilayil7713
@noufalkilayil7713 2 года назад
informative 👍
@EngineerTaj
@EngineerTaj 3 года назад
Nice 👍
@vnesmuonnam
@vnesmuonnam 2 месяца назад
Thank you
@iqbalfarook2866
@iqbalfarook2866 11 месяцев назад
My 1 ton bluestar split has issue like blower is not throwing complete air it stuck in some places. Air flow comes with whzzzz whzzzz sound. I can fell the chillness and cooling. But air out flow from blower stuck in one side. My Ac mechanic told the same u trap. Is the u trap recommended for my issue. I changed outdoor eveporator coil my blower fan is good no issues, I did full water service gas level is also good.
@unidyn2
@unidyn2 3 года назад
I'm going to install a 12k btu mini split outside compressor about 6' above the inside evaporator. The unit comes with 16' tubing - aluminum with copper ends, so I don't want to cut the tubing. I calculated I need about a 10' line. Some people coil the extra line behind the compressor. I was concerned about oil flow, but after watching your video it seems that the coiling would create an oil trap and be beneficial. Do I need to be concerned since the entire line is only 16' and is there a best practice to follow when mounting the compressor higher than the evaporator?
@namesj
@namesj 3 года назад
I always try to go back and forth behind the unit to hide extra piping (if I'm closer than 10 feet) most ductless have an oil return cycle. That should return any oil that is I the evaps. Having oil traps in a ductless should be avoided if possible. Makes for a quieter system. (Less chance of the swishing or gas noise some people hear for time to time)
@angelitoperalta2908
@angelitoperalta2908 2 года назад
Sir can you help me improve our system. We are now experience oil logged in evaporator. The compressor cannot collect it back to the crackcase.
@Z-Ack
@Z-Ack Год назад
Are there auto drainbacks like solenoid controlled with discharge? I know they make em for air compressors but those work with float valves..
@alfredovelez8395
@alfredovelez8395 9 месяцев назад
Typically a check valve on the discharge line of compressor prevents any refrigerant migration
@hg2.
@hg2. 2 года назад
Oy... nice effort, but this format needs work. It fails in it's primary objective, which is good communication.
@char.s1ksmashing444
@char.s1ksmashing444 Год назад
We dont use 45° fittings in refrigeration. Also inverted p traps are usually installed at top of riser.
@pacospete4299
@pacospete4299 4 месяца назад
so i'm seeing folks install these mini split systems ans coiling the access lines next to the outside unit .... is this a problem ?
@goru426
@goru426 Месяц назад
Not for R-410a systems. It was a problem with the older R22 refrigerants.
@adrianlieutier7159
@adrianlieutier7159 2 года назад
Wouldn’t installing an oil separator on the compressor stop all these issues?
@golddroger31
@golddroger31 2 года назад
Not if compressor is on the roof. You wouldnt be getting any oil if no trap, usually commercial applocation when compressor's on the roof
@adrianlieutier7159
@adrianlieutier7159 2 года назад
@@golddroger31 so your telling me if I install a compressor on the roof with an oil separator(which collects the oil from the discharge side of compressor then pumps back into compressor) I’d have no oil ?
@klidaras11
@klidaras11 2 года назад
@@adrianlieutier7159 Correct!, an oil seperator ''catches only'' about 90-95% of the oil so eventually the oil will go away, problem is how to take it back.
@atnstn
@atnstn 2 года назад
@@klidaras11 You are considering HVAC installation Scenario 1 - Condenser is ABOVE evaporator. However when Evaportor is Above the Condensing unit, is it obligatory in your opinion to have oil trap? Just as shown in: 04:01
@itsprimetime9865
@itsprimetime9865 Год назад
@@adrianlieutier7159 obviously these guys who are telling you this don't know what an oil seperator is an oil seperator is installed when you have a very very long pipe run either discharge or suction line the Oil seperator is used to pretty much prevent the oil Running away from the compressor and get stored in the seperator and pushed back in to the compressor
@jerrylockhart3069
@jerrylockhart3069 3 года назад
No comments and no views I guess nobody’s doing any traps
@tecniman356
@tecniman356 10 месяцев назад
I do traps, in building with 4 floor and up
@rcinfla9017
@rcinfla9017 11 месяцев назад
The wiggling hand is annoying and distracting.
Далее
Advanced Refrigeration - Oil Control Systems
15:18
Просмотров 40 тыс.
Макс Пэйн - ТРЕШ ОБЗОР на фильм
47:02
İranda azərbaycanlı prezident seçilib
00:32
Просмотров 153 тыс.
Refrigerant Lines 3D
7:54
Просмотров 13 тыс.
Accumulator Facts & Tips
24:44
Просмотров 119 тыс.
HVAC Installation: Brazing Refrigerant Lines
7:35
Просмотров 4,5 млн
Long Line Applications
1:07:15
Просмотров 43 тыс.
Макс Пэйн - ТРЕШ ОБЗОР на фильм
47:02