Upper class insulation resistance fault-finding 

David Savery Electrical Services
Подписаться 34 тыс.
Просмотров 21 тыс.
50% 1

It’s alright for you sat in your trampy little semi-detached because if you have wiring woes, simply slap up some new cable in oh-so attractive plastic trunking and you’re back in business. Not so here though, and it doesn’t help that the last guy made up his numbers...
Affiliate links:
If you want to be like Mr Humbug and have a shout out in a future video, you can buy me a beer or cigar here or with the SuperThanks button:
www.buymeacoff...
My ridiculous Amazon storefront:
www.amazon.co....
£50 off YourTradeBase:
go.yourtradeba...
Get £40 credit for switching to Zen Internet:
zen.mention-me...
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout!
krystal.uk/
Recycle your scrap cable at greencable.com - use referral code GREENCABLET1ZT when setting up an account and I'll get a tenner while you get a recycling bin delivered at no cost!
For more on my video content, refer to my OnlyFans page (not really an OnlyFans page):
dses.co.uk/ind... or at dses.tv

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 312   
@AndrewStrydomBRP
@AndrewStrydomBRP 7 месяцев назад
On the round pin stuff, arguably the fusing factor of 3036 rewireables is much worse than our modern 60898 MCBs, hence there is an additional derating factor (Cf) listed in 7671 and the OSG on Page 167 specially for just the 3036 rewireables (0.725 derating), so they're probably running under the designed in overhead of the BS546 accessories, but the 546 standard is yet to be updated with the reality that nobody is fitting rewirables anymore. Also, had you not made yourself a little plug yourself, you can pick yourself up a UK to India travel adaptor. India still uses our 5a 546 plug (from my understanding officially uprated to 6a), and then you can hook up a standard plug checker/MFT to them as desired.
@ef7480
@ef7480 7 месяцев назад
You mean the cooker radial based on the 'axiom' 32A must have a 6mm circuit?
@AndrewStrydomBRP
@AndrewStrydomBRP 7 месяцев назад
@@ef7480 With 3036 fuses, you must use a 6mm2 for a 32a load, but you can get away with 4mm2 on a 60898 as long as it's clipped direct. That would probably be the best real world example of the cables being oversized due to the protective device taking longer to trip.
@ef7480
@ef7480 7 месяцев назад
@@AndrewStrydomBRP- correct
@MS-Patriot2
@MS-Patriot2 7 месяцев назад
Dave, I’m loving the ‘I slept in a skip’ look. Exudes genius.
@dsesuk
@dsesuk 7 месяцев назад
Actually, it's a wheelie bin.
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
@@dsesuk That sounds comfortable (not) 🤣
@londontrada
@londontrada 7 месяцев назад
Found a house full of that green goo a while back it was dripping down the walls out if the switches and sockets; horrible stuff. Looked like Slimer from Ghostbusters had been round there. 👻👻👻👻👻👻
@KnugenMooMoo
@KnugenMooMoo 7 месяцев назад
Happy belated birthday big boy!!!!
@alvina69
@alvina69 7 месяцев назад
The amount of C2’s on that report, he obviously thought he would be quids in on the remedials.
@Nigel1969
@Nigel1969 7 месяцев назад
Liked this video although i know its gonna be a hassle to solve the problems, it does get the Poirot juices flowing though and keeps that diagnostic grey matter in top trim lol.I wonder if they would consider kinetic switches which would cut down a lot of ball ache on the lighting etc.... As always great video Dave and was nice to digest👍👍
@dsesuk
@dsesuk 7 месяцев назад
Kinetic is an option we have these days, thankfully, because we're not going to be able to do anything about some of the wiring on this site.
@jamiej779
@jamiej779 7 месяцев назад
As always your work and fault finding is amazing 🤠
@stephenwilliams6103
@stephenwilliams6103 7 месяцев назад
I've got to go & have a look at a job in Chelmsford. From what I've seen in photos from customer, VIR is in place atm, with 1980's storage heaters. Looks like it'll be a good little earner. 😁
@oninbridders
@oninbridders 7 месяцев назад
Happy 50th Year David 🎉
@doublebass5y
@doublebass5y 7 месяцев назад
jesus man i would have given up after the cut cpc,s. what ya gonna do now. Well ben you will have to watch the rest .
@glynnepritchard2526
@glynnepritchard2526 7 месяцев назад
You need to go for the Tunnocks
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
Caramel Log is the best
@mikethemask1525
@mikethemask1525 7 месяцев назад
Nothing wrong with having 2 phases in a switch as long as theres label inside the swtich and its on the paperwork and board
@dsesuk
@dsesuk 7 месяцев назад
True, but here there's no need.
@mikethemask1525
@mikethemask1525 7 месяцев назад
@@dsesuk yes I agree it's unnecessary here I knew you'd know i was just highlighting it for the young sparkies on here incase they come across it and have meltdown haha Great video though interesting aswell those sorts of properties are nightmare to work with as like you said you can't just chop into the wall or smash a few holes 🤯
@AndyK.1
@AndyK.1 7 месяцев назад
16:30 metal switch, no cpc, screwed tight back. Not a good combo
@dsesuk
@dsesuk 7 месяцев назад
Perhaps a case of the guy doing first-fix not being on speaking terms with the guy doing second-fix!
@acelectricalsecurity
@acelectricalsecurity 7 месяцев назад
It all depends what the individual requesting the work wants, do they want to know the true condition of the installation, or do they just want a piece of paper saying satisfactory at the cheapest price, and it's mostly the latter. Knowing, should the preverbial hit the fan they have a get out of jail card, because they used a registered company. But let's face it electricians are not the sharpest tools in the box when it comes to pricing jobs, they will happily spend thousands on test gear and tools, only to then do a drive by EICR for peanuts, thinking it's quick easy money, yet not realising the liability they are taking on by signing that document. Compare it to your average car mechanic, who may charge hundreds for diagnostic work, when hooking up their tester to your car, for less than an hour sometimes.
@haldo691
@haldo691 7 месяцев назад
Unable to find the circuit with the chandelier? More like im not touching that to test it
@dsesuk
@dsesuk 7 месяцев назад
I won't be taking it down either, but I can get EFLI readings from the metal switches and use a wander lead to get an R2 out of the chandelier without disassembly to at least make sure everything's earthed.
@g0fvt
@g0fvt 7 месяцев назад
Although I work in a slightly different field, the forged paperwork makes me rant too. Managers like the forgers, they are far more "productive" than engineers that are thorough and actually do the testing. I remember well a case where a specific piece of test equipment always time and date stamped the measurement data in American format, something a forging colleague overlooked when he edited an earlier document. Happy Birthday
@TheChipmunk2008
@TheChipmunk2008 7 месяцев назад
No issue whatsoever with the BS546 sockets being on a 6 breaker. 2 amp were allowed on 5A BS3036 for lighting
@JC-jv5xw
@JC-jv5xw 7 месяцев назад
Just looking at the pins of the 5A, they are about 3 times the size of the pins on the alleged 15A schuko sockets. I bet the 15A BS546 is good for at least 30A.
@Geeraffe
@Geeraffe 7 месяцев назад
Brilliant vintage Savery playing cluedo in the big house 👍
@darrenstrong5389
@darrenstrong5389 7 месяцев назад
As a older learner, your videos are factual with the right amount of profanity. Excellent work as always
@dsesuk
@dsesuk 7 месяцев назад
And a handsome front man too!
@sarahjrandomnumbers
@sarahjrandomnumbers 7 месяцев назад
It's the profanity that tells you you're dealing with someone who knows what they're doing. The ones stood in a well lit studio reading off an autocue, with perfect audio are the ones you have to be worried about.
@darrenstrong5389
@darrenstrong5389 7 месяцев назад
@@dsesuk that goes without saying! The Brad Pitt of the Electrical world! About the same age.
@generaldisarray
@generaldisarray 7 месяцев назад
56:07 couldn't agree more, if you're going to do a job do it right. I'm in the IT game and I've been in the same situation where someones asked me for a price for the job and they've complained that I'm too expensive. Then they've gone with the cheaper guy, and a few weeks or months, depending, I've got a sheepish call from them asking if I can come in and not only fix the original issue, but also clean up the mess the other guy made of x and/or y. Which of course is going to cost more than just getting me in to do the job in the first place. Sometimes customers are their own worst enemies. As the saying goes, buy cheap, buy twice.
@davidwatt865
@davidwatt865 7 месяцев назад
Happy birthday and how pleasing is it to find a fault on a gaff like that, I had one recently on a big 15th century farmhouse which had me chasing my arse until the clients said they’d had squirrels in a certain part of the house, so they agreed to me cutting an access hole in a false wall and right before me the god damn varmints had chewed through 2 cores of a 3core 2 way cable! Big smiley faces all around and home in time for tea and medals😀 Great content once again 👍
@s.kxx1956
@s.kxx1956 7 месяцев назад
Normally the green goo appears where heat is apparent such as a lamp holder where in the past it would have had 100W lamps or at dimmer switches. Normally just at those ends. If it’s throughout the whole run then it really needs replacing
@olly7673
@olly7673 7 месяцев назад
Good old Classic David Savery quality Fault Finding Mission Video, this is absolutely brilliant! It shows how rewarding it is to trace and resolve a fault. So the return path to the board via the metalwork of the bracket and light fitting was a bit scary, should anyone have touched it when on. Regarding your question of a 5A socket on a 6A breaker, having looked into it is my view is that it doesn't even need a mention as long as it is on a 6A breaker. Most of the sources I looked at were of the same opinion and let's face it, with modern LED lamps it isn't going to stress any equipment being used in the socket that is supposed to be used. i.e. lighting. You can't account for Darwin award candidates who put a 5A plug on their 3kw kettle. Even then the worst that can happen is that the breaker will hopefully trip before the cable goes on fire. I think your BS546 test adaptor is a brilliant bit of kit and still relevant, and something I will have a go at emulating. Have you spoken to Kewtech about it as is it right up their street, or TIS? A few months ago I had a newish property where the owner had floor lamps in every room via BS546 sockets, even the bathroom. As for the Chockbox being used possibly indicating an electrician didn't do the downlights...... erm... I've seen NICEIC Approved contractors on big sites having them in the toolbox and using them. It's all to do with profit as they cost buttons over doing it properly. And, as you say, why did they even bother when the JCC connector block does a better job. Those double insulated pieces of crap usually from Next, John Lewis or M&S I find are great candidates for the Quickwire "Switch and load" connectors. As for £700 for your 3 day EICR, I would say you're doing yourself short. The industry has been blighted by cheap EICRs that are definately not worth the paper they are written on and you highlight it well. Unlike my unwanted lengthy comments David your lengthy videos are very much welcome as I often point out but am backed up by your other roadie nerds. Have you decided if you are going to Ally Pally ELEX yet?
@dsesuk
@dsesuk 7 месяцев назад
Wotcha Olly. Linda and will be at Ally Pally both days all being well. Will you be there? As for those choc boxes on this site, I suspect they were installed on halogen downlights and someone later fitted the JCC's. Rather than re-terminating them, they cut off the two-core to the halogen driver and fitted them into the JCC connector. That's my take anyway. You still get BS546 sockets of course - I've even been asked to install them before, however you'd think the manufacturers would have rated the plug and socket for 6A these days instead of it still being 5A.
@olly7673
@olly7673 7 месяцев назад
@@dsesuk If I get the chance I will try and get there and buy you a pint (Linda can have a 0.0abv of course) I read the 5A sockets are still a thing in the likes of India ( Old Colonial days) and the BS546 standard for them over MCBs etc hasn't moved on and they are advertised there as 5A/6A nowadays.
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
@@dsesuk If you're not overloading them I don't see the problem. You're never going to be putting 5A through the average lighting circuit these days; perhaps when everyone had 100 or 150W incandescents everywhere, but not now. Look at radial power circuits; 20A breaker with 13A sockets, there's far more chance of overloading them with all the crud people plug in.
@walseee
@walseee 5 месяцев назад
I’m at 27:32 , the whole family are loving the video so far, even got grandma involved. I hope there are any unruly surprises. ❤
@TheGorillahands
@TheGorillahands 7 месяцев назад
This is the content i want to see, something you get your teeth into, alot better than seeing another fusebox looking beautiful inside, fantastic content Sir David
@Dog-whisperer7494
@Dog-whisperer7494 7 месяцев назад
Brilliant work David , some other electricians would have just bull shitted there way through that what looks like a lovely house. Someone before you clearly did just that. This is what separates you from the dick heads . Thank you for yet another fantastic video and happy belated birthday and wedding anniversary. You’re still ten years younger than me and I’ve been married thirty six years. 🍺🍺🍺🍺🍺👍
@dsesuk
@dsesuk 7 месяцев назад
Cheers Sean. If it helps, I may be ten years younger, but I feel ten years older.
@zombiefeelpain
@zombiefeelpain 7 месяцев назад
Always Kit Kat, I’m surprised how many of these grand design style houses have shoddy or half cocked wiring.
@ElliottVeares
@ElliottVeares 7 месяцев назад
Item #44, then why can you still buy switchless sockets?
@Ragnar8504
@Ragnar8504 7 месяцев назад
I was about to ask that - as far as I know there's no requirement for sockets to have switches anywhere in the regs, so how can that even be a code?
@ElliottVeares
@ElliottVeares 7 месяцев назад
Exactly@@Ragnar8504 As quoted from DSES website: "1. Unswitched sockets are no longer compliant with regulations and need to be replaced with switched versions. False. Plugs and sockets have to comply with British Standard 1363, however this standard allows for both switched and unswitched socket variants. Older installations often have non-switched sockets and they remain perfectly acceptable; such can still be purchased off-the-shelf today as shown below. So long as the socket remains compliant with BS1363, is not damaged, impaired or faulty in any way, has sound contacts and passes requisite testing, then there is no need to replace it with a new switched faceplate unless you, the client, specifically want the ability to be able to flick any connected equipment on or off via the socket front. That’s up to you though, there’s nothing in BS1363 (plugs & sockets) or BS7671 (IEE Wiring Regulations) stating that unswitched sockets, where encountered, are required to be replaced for switched variants. In some online discussions, the need for 'emergency switching' is tiresomely dragged out as the reason why a socket should have a switch, but basic isolators such as socket switches, light switches, cooker and shower switches (etc.) are not installed for the purpose of emergency switching, only for localised operation or isolation for maintenance purposes. It's important to recognise the difference between functional switching and emergency switching, the latter seldom spotted domestically and usually recognisable by being big, red and with something like STOP being stamped upon them! Indeed, under regulation 537.3.3, BS7671 requires emergency switches be accessible, coloured (preferably red), labelled with a contracting colour (preferably yellow) and capable of being locked off in the OFF position, none of which applies to a switched socket outlet hidden behind your sofa. Emergency switching is also required to isolate all 'live' conductors (line and neutral wiring), however many socket outlets switch single-pole and only isolate line. It's evident that socket switching is only for functional convenience then. If BS1363 and BS7671 (the wiring regulations) disallowed the use of non-switched sockets, they simply wouldn't be available for purchase on the high street as they so readily are."
@dsesuk
@dsesuk 7 месяцев назад
@@ElliottVeares Crikey, I forgot I wrote that - it was over ten years ago! I also just spotted a typo, that should of course say 'contrasting colour' - now corrected! But yeah, the more you go through this report, the more nonsense you find.
@markyd2633
@markyd2633 7 месяцев назад
Yep.....well done finding that fault a great vid as usual.....loving the hour long ones
@digitalradiohacker
@digitalradiohacker 7 месяцев назад
42:14 "Theres some bulging in the wall" Choc boxes. Fucking loads of choc boxes covered in green goo.
@Ben-gm9lo
@Ben-gm9lo 7 месяцев назад
Happy Belated Birthday young sir. Lovely to see a video of some professional sleuthing. it is work like that which separate a properly trained professional from us keen DIY hacks and, it would seem, some other 'properly trained professionals'. Really enjoyed the investigative process and your humour.
@russ1669
@russ1669 7 месяцев назад
I'm not surprised the tower was wobbly. Only 1 diagonal, and staggered wheel heights...
@sstorholm
@sstorholm 6 месяцев назад
I don't get the rating of those lighting plugs, by the looks alone it should be able to handle 10A with ease, and all euro plugs are unfused anyhow and the whole of Europe isn't on fire due to that either. I'd imagine the rating is from the time of old fuses, with a lot slower time factor.
@pronarekt-gaming3334
@pronarekt-gaming3334 6 месяцев назад
I always do circuit names only first to get around the easycert problem. Shouldn't have to do it mind you but better than the alternative.
@RichardArblaster
@RichardArblaster 7 месяцев назад
Happy Birthday David 🎉🎉🎉
@craigwilliams6734
@craigwilliams6734 7 месяцев назад
Are you missing Nigel, David? I think you might need a new side kick…?
@DT-uy1ex
@DT-uy1ex 7 месяцев назад
We followed a eicr the bloke put redundant cables need taking out of fuse board as they may scare someone this is at a decent size factory i informed manager the condition report wasn't worth a chew of baky to which he responds i know but they are cheap
@breakz187
@breakz187 7 месяцев назад
That light switch reminded me of this scene ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PNVEQgXsBgs.html
@digitraxuk
@digitraxuk 7 месяцев назад
Love the number at the bottom of your easycert cert 😂😂😂 Quite right poor software programmers.
@matthewdale956
@matthewdale956 7 месяцев назад
Another solution would of been to put a Hager afdd in, never would of tripped 👍🤝😉
@Woodkin007
@Woodkin007 7 месяцев назад
As a sole trader, i would run a mile from that property. Dont have a Robin to help me out or keep me sane.
@kiphakes
@kiphakes 7 месяцев назад
Really enjoyed this.. but - what's a 'strapper'? 🤔
@dsesuk
@dsesuk 7 месяцев назад
Ah. I perhaps should have explained. Strappers are the wires between light switches in a two or more way configuration. In this case, power goes into one switch, along one or the other strappers depending on which positions each switch is mechanically set in, then out the other switch to the light.
@kiphakes
@kiphakes 7 месяцев назад
@@dsesukAhah! I did wonder if that was the case! Just not heard that term before!
@mrhumbug5353
@mrhumbug5353 7 месяцев назад
Happy birthday. And coincidentally I also got married two days after my birthday. My wife had a cunning scheme that I would never forget our anniversary, but now that I'v had a few more birthdays I don't tend to pay much attention to their imminent arrival so I'm scrabbling around for an anniversary card and present on only two days notice.
@ceangasrevenge
@ceangasrevenge 4 месяца назад
Very Funny guy I would have a good time working with you !
@ltdeditions
@ltdeditions 7 месяцев назад
Fifty? How's that possible? I've always considered you to be some sort of master Yoda, whilst looking at myself as a young Luke Skywalker, but we're almost the same age! Anyhoo, great bit of fault finding. Always love following your thought process! Congrats to you and misses Savery!
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
I remember being 50... Come to think of it, I remember being 60 as well... 🥴
@alanpowell24
@alanpowell24 7 месяцев назад
This is soooooo interesting, and great to see videos by a professional that really seems to know what he is talking about. Occasional profanity makes it even more genuine……….
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
Only just started watching, but I think I'd run screaming from that job 😵‍💫🤣
@londontrada
@londontrada 7 месяцев назад
yea
@dsesuk
@dsesuk 7 месяцев назад
It's not so bad if you take the piecemeal approach and go around tackling issues one at a time.
@londontrada
@londontrada 7 месяцев назад
You edited this comment? You were asking if it was a 3 phase board?
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
@@londontrada Yeah, I realised it was obvious given the size of the property and when 400V got mentioned.
@FrontSideBus
@FrontSideBus 7 месяцев назад
I think you should give Linda Nige's old job lol. Where is she actually from? I can't really place the accent.
@dsesuk
@dsesuk 7 месяцев назад
You'll be seeing more of her. She's a Saffa originally.
@FrontSideBus
@FrontSideBus 7 месяцев назад
@@dsesuk Ah yes, of course!
@hardave17
@hardave17 7 месяцев назад
With Nigel fcked off it seems like your step count has dramatically increased Sir David!
@richardharris8777
@richardharris8777 7 месяцев назад
Good video Mr Savery. Totally agree with the metal " double insulated" crap out there. How! Why! Also worry about old 2 core 0 earth cable having no inherent cable protection but, isn't half the world, and I see Doncaster Cables are selling in the UK now, insulated, colour coded cpc earth in ordinary cable doing half the same job. No rat biting through that will necessarily expose the earth when biting through the live and neutral. Madness to reduce protection like this. Not sure why you hate choc box quite so much they have a place.
@richardharris8777
@richardharris8777 7 месяцев назад
Plus, what the hell is wrong with 5 amp lighting sockets other than the nomenclature. They are safe on 6 amp and make switched lighting circuits which are must safer than plugging in table lamps factory fitted with 13amp plugs and fuses.
@peterwhite51
@peterwhite51 7 месяцев назад
Happy Birthday, Can I ask for details of your Analogue test meter, I still use one, but it's seriously Knackered!
@dsesuk
@dsesuk 7 месяцев назад
The meter is a Hioki 3490 - a popular instrument down under although rarer on these shores. I bought mine from Farnell and, sadly, it was nicked with my toolbox last Friday. If one appears on the second hand market, it'll probably be the very instrument in this video. If you want to know more about it, there's a video in my back catalogue from summer 2022 when I first bought the thing.
@triplex9732
@triplex9732 2 месяца назад
Excellent work spunk garguler
@chrisfairbrother9197
@chrisfairbrother9197 7 месяцев назад
Excellent video David. You demonstrated a very logical approach to the fault. I expect most home owners would not appreciate how many hours you spent on solving one circuit problem, and you are only 50! ( you must have had a hard life😊) Many happy returns 🎂
@dsesuk
@dsesuk 7 месяцев назад
Tracing faults like this is what ages me terribly.
@walseee
@walseee 5 месяцев назад
This is recorded like found footage
@davidpatterson1574
@davidpatterson1574 7 месяцев назад
Excellent fault finding video David- Nuff said
@superiorbeing95
@superiorbeing95 7 месяцев назад
Just a non-electrician having a brain fart, but with LED lighting now becoming the norm, it seems to me that delivering mains voltage at every lighting point and at every switch is an unnecessary old world way of doing things and especially in these circumstances there are easier ways of providing switched lighting.
@dsesuk
@dsesuk 7 месяцев назад
These days we could do with a 12 or 24V DC distribution around the average abode to cut down on all the mains adaptors and products with step-down transformers.
@alhamilton7261
@alhamilton7261 3 дня назад
err 250v not 500v ....
@AAW-Electrics
@AAW-Electrics 7 месяцев назад
24:24 - I see you're a fellow Huel drinker 🙂
@sdgelectronics
@sdgelectronics 7 месяцев назад
My house is full of Astro lights 🤣They make some really nice looking fixtures. Fitting them takes 2x longer though.
@dsesuk
@dsesuk 7 месяцев назад
That's the trouble though Steve, they look great, but they're a ballache to install properly!
@almerdiahmed3160
@almerdiahmed3160 7 месяцев назад
That was great job thanks 🎉🎉🎉🎉🎉🎉🎉🎉🎉🎉.
@andrewcadby
@andrewcadby 7 месяцев назад
11:05 I wouldn't code it. There is no sane way that the socket could be subjected to more than 5A passing through it. Note that, for example, pendant sets have 0.75mm2 flex, rated at 6A, yet are perfectly fine on up to a 16A circuit.
@dsesuk
@dsesuk 7 месяцев назад
Good point.
@JK50with10
@JK50with10 7 месяцев назад
I'm surprised that the screw through the cable didn't show up as a resistive fault.
@dsesuk
@dsesuk 7 месяцев назад
In both my Hioki 3490 and Nuisance Glowing LED Lights videos I used an apparatus to demonstrate how a screw could penetrate a cable where there was no resistive fault, yet it showed up on IR. If there's still a tiny insulation gap between the screw and the copper, be that an air gap or a sliver of PVC, then the continuity tester won't have enough EMF to get past the resistance, however the higher potential of the IR test will break down that insulation and allow current to cross it.
@heffo1992
@heffo1992 7 месяцев назад
Why would you bother with that easy cert? It looks like a bad version of excel
@dsesuk
@dsesuk 7 месяцев назад
For the most part it works, and it's cheap after year one. It just has some stupid flaws.
@bsesin
@bsesin 7 месяцев назад
happy birthday / anniversary old chap...
@dlh190
@dlh190 7 месяцев назад
That cheerful look on your face when you found that lighting circuit fault was the highlight of the video. 👍
@dsesuk
@dsesuk 7 месяцев назад
I thought I'd never get to the bottom of that sucker!
@geoffhubbert6916
@geoffhubbert6916 7 месяцев назад
Just checked Easycert on the work tablet. If you leave the IR values blank in “ Setup Circuits” it doesn’t autofill with >200 on the certificate. This is on the Android version so windows may be different?
@dsesuk
@dsesuk 7 месяцев назад
Sadly, the Windoze version doesn't play ball. I would like to play with the android one. I had been wondering about a touchscreen Chromebook to get the best of both worlds (touchscreen and keyboard) for field entry.
@TestGearJunkie.
@TestGearJunkie. 7 месяцев назад
@@dsesuk When is somebody going to produce a Linux version of all these things..? Not everybody wants to use Micro$$oft Windoze. And anything with "Chrome" in the name is spyware par excellence, steer well clear..!
@markpunt9638
@markpunt9638 7 месяцев назад
Happy birthday - happy anniversary.I hate ladders but I feel quite safe on people’s sturdy platforms.
@dsesuk
@dsesuk 7 месяцев назад
It's funny with platforms, I always go jelly-legged but it's not because of me being up there, I'm always worried I'm going to drop a tool, tester or the client's light fitting!
@ratsalive
@ratsalive 5 месяцев назад
Happy belated 🎉
@hackwoodelectrical
@hackwoodelectrical 7 месяцев назад
Had a job to replace some RCBOs in a similar style of property. Absolutely massive, lots of outbuildings, renovated in the 80’s at a guess… Noticed there was green goo so made the homeowner aware Suggested an EICR Explained the issues of the goo Heard nothing back.
@WimTon
@WimTon 7 месяцев назад
I am watching these electricians' videos to see the British electricity traditions (I am from the continent). I am surprised that half of the videos show professional electricians repairing the work of other professional electricians. Is there no quality control and audit process?
@dsesuk
@dsesuk 7 месяцев назад
It's the wild west out here because there's no registration system, so anyone can claim to be an electrician and perform electrical work. There are professional bodies one can register with such as NICEIC, Select and NAPIT among others, but even then there are a lot of shoddy operators and an overall lack of oversight.
@petermichaelgreen
@petermichaelgreen 7 месяцев назад
Prior to 2005 electrical work in England and Wales was almost completely unregulated. In 2005 some electrical work was made "notifiable" under the building regulations, requiring it to either be notified to building control (which is an expensive PITA), or to be performed by an electrical contractor registered with a self-certification scheme. In reality most electricians are a member of one of those schemes, but the schemes seem to do a piss-poor job of keeping them members honest and diligent. Still it's probably an improvement over the pre-2005 situation. In 2013 the list of work requiring notification in England (but not Wales) was reduced considerablly, I don't think this made a huge amount of practical difference though. Scotland has their own rules, but I don't keep track of the details. IIRC electrial work in Northern Ireland is still unregulated.
@gavowassy7655
@gavowassy7655 7 месяцев назад
Oh the anxiety!
@Sunsetseven
@Sunsetseven 7 месяцев назад
That's a great Video, showing perfectly how a proper pro fixes what is actually quite a complex fault given the size of the property and number of ways. Good work 10/10 and a DSE merit award ;-)
@datsunruss
@datsunruss 7 месяцев назад
Yep, he couldn't be arsed to find the fault so made up a load of humbug. Good job young Dave getting to the route. Great watch that video. 400v at the switch!!!! HOLEY MOLEY.
@alunroberts1439
@alunroberts1439 7 месяцев назад
What is the G Shock you have on ???
@dsesuk
@dsesuk 7 месяцев назад
It's the GW-7900B, radio controlled & solar powered.
@dazzafat
@dazzafat 7 месяцев назад
Happy 50th dave
@dsesuk
@dsesuk 7 месяцев назад
I still have the mind of a teenage schoolboy and the body of a 60 year old.
@RichardArblaster
@RichardArblaster 7 месяцев назад
Unable to Find = Can't be arsed to Find 😆😆😆
@dsesuk
@dsesuk 7 месяцев назад
It's a complicated and sprawling site to familiarise yourself with Dickie, but yes, tracking down what a lighting circuit is doing isn't too troublesome. Simply turn on all the lights, then see what goes out when the breaker is flipped!
@markrainford1219
@markrainford1219 7 месяцев назад
= customer unwilling to pay more.
@RichardArblaster
@RichardArblaster 7 месяцев назад
6:02 Mini Roll 😎
@dsesuk
@dsesuk 7 месяцев назад
So wrong.
@clivequinn8978
@clivequinn8978 7 месяцев назад
Great fault finding.
@anthonybragg
@anthonybragg 7 месяцев назад
The socket spur off a spur was changed in 1981 from 14th to 15th. Regarding the 6A protective device and the 5A outlet, the same with the 5A terminal blocks. Are you ever going to get 6A flowing through or out of a 5A socket? Anyway, nice fault finding Dave they don't teach that at college.
@mikel8478
@mikel8478 6 месяцев назад
14.31 'This must be the I don't want to talk to you chair' 😂 fucking gold!
@timhoward7037
@timhoward7037 7 месяцев назад
18 minutes in, I'm starting to think a Quinetic lighting rewire is the only remotely viable answer, but only 16mm boxes so the big ugly switches... I'll be intrigued to see how this one unfolds. Everything you look at adds a new problem!
@steveaspey8790
@steveaspey8790 7 месяцев назад
Another brilliant episode, thank you. I wonder why Wago don't make those new push fit through connectors round? Would make a neater heat shrink joint for sure, just a thought.
@muttlymoo
@muttlymoo 7 месяцев назад
See your point about assessories rated below the rating of the protective device regarding the 5amp lighting sockets.. But realistically it never going to be overloaded with one table lamp plugged in.. No code from me
@AdamWatson001
@AdamWatson001 7 месяцев назад
4:51 - Hey! That's my house you're talking about! My misses chose it because it is only a 5 min walk from the school... Although, it is a sh1t street to walk on lol.
@stuartthespark
@stuartthespark 6 месяцев назад
Happy birthday Dave.
@dsesuk
@dsesuk 6 месяцев назад
Thanks Stu!
@titerado
@titerado 7 месяцев назад
Enjoyed that thoroughly, cheers Dave - love a well documented sleuthing including the history, repair and challenges. Would love to know your full shitlist and what they do wrong on a video some day.
@tebscat
@tebscat 7 месяцев назад
I was 'lost' in a place very similar to that for several years, until the retirement and change of estates manager. Then it was change of electrician, plumber, gardeners, roofer as the new broom swept clean. Yep, big old places like that keep a lot of people busy... About 3 years in I discovered a new-to-me DB tucked away in an eaves space. The wiring in a lot of these places is definitely a case of all fur-coat but no knickers. Not many owners want the upheaval of six months to a year of rewiring and making good, even when they can afford it. And even when they are abroad for the half the year anway...
@rogerbean393
@rogerbean393 7 месяцев назад
Pure genius, good find. Man of many skills and wonderful profanity throughout!
@carlrobson5745
@carlrobson5745 7 месяцев назад
I to am part of the wedding birthday club got married the day before my birthday. That looks a lovely abode be a shame to start chasing walls out rewire you say that’s going to cost a fortune even if they agreed to one.
@EXFElectrician
@EXFElectrician 7 месяцев назад
Yet another great video. Show how some cocks out there say that everything ok on the certificate and in reality completely different. That’s why I want low myself to a price war or rush on an inspection
@Stop..carry-on
@Stop..carry-on 7 месяцев назад
Re the slight Damage to the wall - a timber patress behind the fitting would cap off the damage. It could be finished to the colour of the paneling below.
@Sparkyjedi
@Sparkyjedi 7 месяцев назад
You are class mate, I love how you tell it how it is 👍 proper sparkys plain English, none of this beating around the bush and kissing sponsors arses 😀 , nice to see a proper spark doing ins res readings
@leeroberts1192
@leeroberts1192 7 месяцев назад
Got to about 20 mins through the video so far. I'm not a spark but I get the feeling that this place could probably do with either a partial or full rewire.
@LoftechUK
@LoftechUK 7 месяцев назад
That’s some fucking good fault finding. You do love Hagar
@matthewdale956
@matthewdale956 7 месяцев назад
Fair play for finding that ir low reading ,not sure I would of had the patience.enjoyable watch as usual
@shaunhyatt8150
@shaunhyatt8150 6 месяцев назад
Excellent video David and it’s deserves a cigar for you finds! 😊
@joshuaprest1590
@joshuaprest1590 7 месяцев назад
Watching this at one in the morning in bed with our lass got a funny look when you looked in the booze cupboard like 😂
@supersparks9466
@supersparks9466 7 месяцев назад
Rather you than me mr savo, nightmare going in after some muppets eicr.
@frubert123
@frubert123 7 месяцев назад
"I'm at the grand staircase". Strong "Jet Set Willy" flashback there. Excellent analysis as always.
@ooslum
@ooslum 7 месяцев назад
Guessing as the decor has had little updating, nothing else has. That pissed off, I want to go and rewire a garage look is familiar.
Далее
Новый вид животных Supertype
00:59
Просмотров 210 тыс.
ОБЗОР НА ШТАНЫ от БЕЗДNA
00:59
Просмотров 276 тыс.
Watermelon magic box! #shorts by Leisi Crazy
00:20
Просмотров 22 млн
The trip trap that trips up testers
28:09
Просмотров 30 тыс.
Much ado about neutral trippery
46:59
Просмотров 31 тыс.
The Impossible Angry Karen
2:04:57
Просмотров 126 тыс.
Client says I'm too pricey...
16:46
Просмотров 63 тыс.
Should Have Quoted Double Than I Did
22:02
Просмотров 20 тыс.
Supplementary Protective Bonding and Touch Voltage
22:23
Getting the right sports hall light
1:04:49
Просмотров 13 тыс.
Amazon Sells Fake Electrical Fuses
31:04
Просмотров 327 тыс.